Personal Flotation Collar (PFC-1)

Similar documents
ALPS Flotation Collar. User s Manual

LPU- 40 Flotation Collar

CBP LPU- 40 Flotation Collar User s Manual

SURVIVOR SERIES AIRCREW FLOTATION VEST PACKING INSTRUCTIONS

DO NOT REMOVE PRIOR TO SALE MD1250

Tactical Flotation Support System (TFSS) User s Manual

CREWFIT 165 SPORT. self care and maintenance manual

Owner s Manual. MD3196 and MD3091 Compact Tactical Life Preservers. *Shown with the MA3090 Chest Belt/Crotch Strap Assembly

ANNUAL SELF INSPECTION AND SERVICE INSTRUCTIONS

MD1250 TACTICAL INFLATABLE SIDE POUCH LP

Service Manual. Mullion Hi-Rise 275N SOLAS dot twin chamber lifejacket with Hammar hydrostatic mechanism.

SMA1060 INSTRUCTIONS FOR SELF INSPECTION SMA1061 MANUAL INFLATION SMA1062 AUTO INFLATION

inflatables pfd s ANNUAL SELF INSPECTION AND SERVICE INSTRUCTIONS

SMA1500 Instructions for Self Inspection SMA MANUAL INFLATION SMA AUTO INFLATION

Owner s Manual RESCUE STICK TM MRD100 THROWABLE EMERGENCY RESCUE INFLATABLE

Rapid Survival System

Hammar LifeJacket Inflator

INFLATABLE PFD S INSTRUCTIONS FOR ANNUAL SERVICE AND SELF INSPECTION

INSTRUCTION MANUAL. Featuring - Quick Burst Zipper Survival Operations Specialist SOLAS (74/96) Approved Lifejacket

NATIONAL (NATO) STOCK NUMBER: NSN

THIS CARD IS MAINTAINED TO PROVIDE PROCEDURAL TEXT ONLY AND IS NOT REPORTED TO ACMS

The Service label can be found

ANNUAL SELF INSPECTION / SERVICING INSTRUCTION SHEET

INFLATABLE PFDs. MD2010 Manual Inflation Model. MD2012 Manual with Automatic Backup Inflation Model

Installation, Operation and Maintenance Manual for Back Pressure Regulator

OWNERS MANUAL FOR MODEL TD2401 Inflatable Throwable Device (Type IV PFD).

DO NOT REMOVE PRIOR TO SALE! OWNER S MANUAL for Model No. 1212

IMMERSION SUIT MAINTENANCE GUIDE IMMERSION SUIT MAINTENANCE GUIDE 1409 SERIES. SCMG003A Maintenance Guide - Immersion Suits USA ENGLISH.

Owner's Manual SMA2000 Series

Pressure Dump Valve Service Kit for Series 2300 Units

Pressure Dump Valve Service Kit for Series 3000 Units

Combination Breathing Apparatus

Owner s Manual. MD3085 Inflatable PFD Manual Inflation Model Recreational: USCG Approved Type III Uninspected Commercial Vessels: USCG Approved Type V

FOR MODEL NUMBERS MD2981 (MANUAL) / MD2983 (AUTO) OWNER'S MANUAL DLX 38 INFLATABLE PFD

SMA2100 Series CONSTANT WEAR LIFE PRESERVER VEST (CWLP) SMA2160 OWNERS MANUAL

Maintenance and Repair. AirHawk II Air Mask. Second Stage Regulator. Order No.: /02 Prnt. Spec (I) MSAsafety.

SMA1060 OWNERS MANUAL

WE SAVE LIVES FOR A LIVING

Inflatable PFD Owner s Manual

ExtendAire TM II. Intermediate Pressure Accessory Kit USER INSTRUCTIONS

MUELLER. A Wall Type. Indicator Post. Reliable Connections. General Information 2. Technical Data/ Dimensions 3. Installation 4-5.

Product Information News

INFLATABLE PFD s THE SEQUEL Stu Soffer, N-MS

SPUD OWNER S MANUAL ALWAYS WEAR A COAST GUARD APPROVED FLOTATION DEVICE WHEN OPERATING THE SPUD KAYAK.

600 / 600FC OWNER'S MANUAL


MD2014 INFLATABLE PFD Manual Inflation Model USCG APPROVALS: RECREATIONAL: TYPE III UNINSPECTED COMMERCIAL VESSELS: TYPE V

TABLE OF CONTENTS. Hello! Happy Paddling, SAFETY WARNING WHAT S INCLUDED IN YOUR BOX GENERAL USE INFORMATION INFLATION INSTRUCTIONS FIN INSTALLATION

MAINTENANCE PROCEDURE FOR X 650

Owner s Manual. MD Inflatable Vest with LIFT TM Hydrostatic Inflation Model - Manual with Automatic Backup

3/8" Dr. Air Butterfly Impact Wrench

LTS BCD USER GUIDE. Hollis (2014) Doc r01 (8/29/14)

MUELLER. Mega-Lite Drilling Machine. Reliable Connections. table of contents PAGE. Equipment 2. Operating Instructions 3-4. Parts Information 5

FIRST TEAM SPORTS, INC Storm Portable Series Assembly Instructions

Paintball Marker. User s Manual. 530 South Springbrook Road Newberg, OR 97132

MMR Air Mask With. with Quick-Connect Hose

AUXILIARY ACR PLB Monthly Inspection and Test For use by Auxiliary members issued ACR PLBs within District Eleven North Revised Jan 2016

AirForce Owner s Manual MD3031 Manual with Automatic Backup Inflation Model

MD5183 ELITE INFLATABLE PFD

500SE SECOND STAGE SERVICE PROCEDURE

Falcon 3 145, 170, 195 and Tandem Owner / Service Manual

COMPACT TRIPLE WALL OUTLET STATION MODEL INSTALLATION AND OPERATING INSTRUCTIONS

MUELLER A A Non-Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

Pay special attention to information provided in warnings, cautions and notes that are accompanied by one of these symbols:

SOTR Special Operations Tactical Respirator

Personal Flotation Devices (PFDs) Lifejackets & Buoyancy Aids - The Facts

Inflatable Personal Flotation Device (PFD)

SAILTEC, INC CONGER COURT, OSHKOSH, WI USA

Butler Tactical Parachute Systems, LLC

Inflatable Personal Flotation Device (PFD) OWNER S MANUAL

Inflatable Stand-Up Paddle Boards SUPS OWNER S MANUAL

Booster Pump PB4-60 Replacement Kits

MUELLER. A A Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

isup MANUAL THANK YOU FOR PURCHASING A KAHUNA isup, WE HOPE YOU HAVE MANY YEARS OF PADDLING ENJOYMENT.

Hydraulic Punch Drivers

COMFORT MAXTM BELT PACK

DO NOT REMOVE PRIOR TO SALE! Model Nos or 6340 OWNER S MANUAL HIGH WEARABILITY TYPE V USER ASSISTED INFLATABLE BELT PERSONAL FLOTATION DEVICE

Assembly Instructions. for. Puffin Saranac. ScanSport, Inc. P.O. Box 700 (234 May Street) Enfield, New Hampshire Phone: (603)

Hydraulic Piston Accumulators

C - SERIES. Height Adjustable Portable Goal Supports. Installation & Owner s Instructions C1000 C2000. Made in the USA

Inflatable Dock Slide Owner s Manual

Sea Rebel Kayak Owner s Manual

3M Liqui-Cel EXF-10x28 Series Membrane Contactor

Pontoon Slide Owner s Manual

User Guide. Tripod. flowtech 75 / 100 Tripod. Part No. S S

Wilo Triple Duty Valve / Triple Service Valve Installation and operating instructions

Inflatable Stretcher. Product Manual

Instruction Manual. PE-25/32/37 Tapping Machines. POLYTAPP Valves

VERTICAL SURFBOARD CARRIER READ ME! IMPORTANT WARNING!

Installation, Operation & Maintenance Manual for Flo-Max Coupler Bracket Model FM150

30T A/Manual Hydraulic Shop Press

MyControl Bathing System Signature Series

Installation Instructions

INSTRUCTION MANUAL. January 23, 2003, Revision 0

DO NOT REMOVE PRIOR TO SALE! OWNER S MANUAL for Model 33M42-V17

Preparation and Installation of the Sanitary BDI-FLX Sensor and Connection to the BDI-FLX Interface Cable

Service and Repair Manual

Model 7989T Steel Pipe Squeezer Sch. 40 & Sch. 80. Operations Manual

KTM OM-2 SPLIT BODY FLOATING BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

Inflatable Stand Up Paddle Board Manual

Transcription:

(A Member of the Protective Engineering Concepts, Inc. Group) The Leaders in Tactical Flotation October 2015 Personal Flotation Collar (PFC-1) PECI Flotation LLC 817 Virginia Beach Blvd. Suite 101 Virginia Beach, VA 23451 www.tacfloat.com Phone: 757-303-7735 FAX: 757-490-1044

Table of Contents Section Page Change Record 3 1. Introduction 4 2. Features 5 3. Visual Inspection 6 4. Maintenance 6 5. Storage 6 6. Annual/Water Use Inspection 7 7. Functional Inspection 8 8. Preparation/Packing 9 9. Service Life 18 Appendix A. PFC-1 Flotation Collar Nomenclature 19 Appendix B. PFC-1 Flotation Bladder Nomenclature 20 Appendix C. PFC-1 Parts List 21 Appendix D. Manual Inflator Drawing 22 Appendix E. Bobbin Information 23 Appendix F. Auto-Inflator Tech Data Sheet 24 Appendix G. Auto-Inflator Drawing 25 Appendix H. Auto-Inflator Rearm Instructions 26 Appendix I. Inflator Assembly Instructions 27 This document is considered Company Confidential and shall only be used for the purpose for which it was supplied. It shall not be reproduced without the express written permission of PECI Flotation, L.L.C. All rights are reserved by PECI Flotation, L.L.C. PECI Flotation LLC Page 2

The following symbols are used throughout this manual: WARNINGS indicate a procedure or situation that may result in serious injury or death if instructions are not followed correctly. CAUTIONS indicate any situation or technique that will result in potential damage to the product, or render the product unsafe if instructions are not followed correctly. NOTES are used to emphasize important points, tips, and reminders. Change Record Change No. Date Title or Description Made By 001 27 Oct 2015 New photo front page, change date TP 002 27 Oct 2015 Add CO2 picture. Page 10 TP 003 27 Oct 2015 Add light instructions. Page 11 TP 004 27 Oct 2015 Add light packing. Page 12 TP 005 27 Oct 2015 New photo. Page 20 TP PECI Flotation LLC Page 3

1. Introduction NOTE: Orientation references the wearer s right and left The procedures outlined within this manual are to be performed only by personnel who have received Factory Authorized training through a PECI Service & Repair Seminar. If you do not completely understand all of the procedures outlined in this manual, contact PECI to speak directly with a Technical Advisor before proceeding any further. The PFC-1 Flotation Collar is a flotation device designed to support personal stranded in water. The collar is attached to the user s carrier. It provides a minimum of 60 pounds of flotation buoyancy and is designed to keep the user s head above the water for an extended period of time. The PFC-1 is packed in a low profile casing made of fire resistant materials that are designed to open when the dual-chambered bladder inflates. A single-pull beaded handle is located on each side, when manually pulled, activates a 55-gram CO2 gas cartridge for inflation. The left side is equipped with an auto-inflate device which will activate within five (5) seconds when submerged in water (salt of fresh). There is also a manual handle for the left side which should be used as the primary means of inflating the collar. The right side has a manual inflator which should be used as a back up in the event the left side auto inflator or handle does not work. Two oral inflation tubes allow the user to manually increase, decrease, or maintain the air pressure in the bladder chambers. These oral tubes have a 2.5 PSI relief valve which will relieve any pressure greater than 2.5 PSI. This could happen if the right handle is pulled and the left side is manually actuated also or inflates with the autoinflation device. NOTE: The capacity of the CO2 cartridges is 55 grams with a minimum weight of 233.8 grams. WARNING THE LEFT SIDE IS EQUIPPED WITH AN AUTO-INFLATION DEVICE, THEREFORE THE LEFT ACTIVATION HANDLE SHOULD BE USED AS THE PRIMARY ACTIVATION HANDLE. PULLING BOTH HANDLES OR RIGHT HANDLE FIRST MAY CAUSE A FAILURE IN ONE OR BOTH BLADDERS BY ADDING TOO MUCH CO2. PECI Flotation LLC Page 4

Your PFC-1 Flotation Collar is an important piece of survival equipment. Proper care and maintenance will ensure your vest will accomplish the level of safety performance it is designed for. It is important that you become familiar with these instructions to safely use this flotation collar. Since the PFC-1 is equipped with an auto-inflator on the left side, the left activation handle should be used as the primary means of inflating the collar. The recommended service life is seven (7) years from date of manufacture. After five (5) years of use (placed in service) PECI recommends replacement of the device. WARNING KEEP YOUR FLOTATION COLLAR IN USABLE CONDITION. IMPROPER WEAR MAY RESULT IN DAMAGE TO THE COLLAR. DO NOT WEAR ANY GARMENT OR PIECE OF EQUIPMENT OVER THE COLLAR. IMPROPER USE OR NEGLIGENT CARE OF THIS EQUIPMENT CAN CAUSE SERIOUS INJURY OR DEATH. 2. Features 1. Minimum Buoyancy: 60 lbs. buoyancy 2. Inflation a. Left side equipped with an activation handle and auto-inflator b. Right side equipped activation handle and manual inflator 3. Oral Inflation: Left and right oral inflation tubes with 2.5 psi relief valves 4. CO2 Cylinders: Left and right CO2 gas cylinders 5. Corrosion Resistance: All parts shall be corrosion resistant in fresh and salt water 6. Rot Resistance: All fabric, webbing, and binding shall be rot resistant 7. Fire Resistant Casing 8. Maximum Weight per Unit: 3.4 lbs. (1.54 kg) 9. Zipper Closure System PECI Flotation LLC Page 5

3. Visual Inspection It is the responsibility of the person using the PFC-1 to perform the visual inspection. Perform a visual inspection prior to each use and at intervals not to exceed 30 days. If damage is found during an inspection, the flotation assembly must be grounded until repaired. 3.1 Inspect the outside of the case for: Cuts, tears, and abrasion damage Open seams and loose or broken stitching Contamination damage 3.2 Ensure that each beaded inflation handle is attached with three (3) snaps fastened. 3.3 Ensure that the entire length of the slide fastener is closed and there are no missing teeth. CAUTION DO NOT OPEN THE FLOTATION COLLAR SLIDE FASTENER FOR ROUTINE INSPECTION 3.4 Squeeze the lobes approximately half way up to ensure CO2 bottles are present. 3.5 Ensure the collar is properly attached to the carrier. WARNING 4. Maintenance Maintenance of the PFC-1 consists of cleaning, service, and minor repair. The person s responsibility for maintenance is limited to inspecting the outside components of the device. If the device needs to be cleaned, only mild soap and water should be used. The device should then be hung to dry in a warm, dry place out of direct sunlight. 5. Storage TWO 55 GRAM, 1/2 THREAD CO2 BOTTLES, MUST BE PRESENT AND PROPERLY ATTACHED TO THE INFLATOR. IMPROPER CO2 BOTTLE OR ABSENCE OF CO2 CYLINDER CAN CAUSE SERIOUS INJURY OR DEATH. Store your PFC-1 on a shelf away from direct sunlight in a dry, well ventilated place. Do not store your device near sources of heat such as a radiator, or in a warm, humid environment where mold or mildew can contaminate the device. CAUTION STORAGE AND CARE OF PFC-1 IS EXTREMELY IMPORTANT PECI Flotation LLC Page 6

6. Annual/Water Use Inspection An annual inspection should be performed annually or when exposed to water to ensure the PFC-1 will perform when needed. It is the responsibility of qualified personnel to perform and log this inspection. The inspection can also be performed at the manufacturer. If damage is found during an inspection, the device must be grounded until repaired. Repairs are limited to replacement of snaps and inflator replacement. All other repairs must be completed at the manufacturer. A functional test should be performed every third year. If a functional test is required, skip to section 7. NOTE: If PFC-1 has been submerged in water, the unit must be thoroughly cleaned and rinsed with fresh water. Hang the unit in a warm dry place out of direct sunlight. 6.1 Remove the flotation collar assembly from the vest and harness. 6.2 Lay the flotation collar flat on the table with the underside down. Spread the outer case open and completely lay out the bladder. 6.3 Preform leak test by connecting a single source of pressurized air to one bladder chamber and the bladder shall be inflated to 2.0 +/- 0.1 PSI using the oral inflation tube. 6.4 After a minimum of one (1) hour, check pressure. Should not loose more than.4 PSI. CAUTION IF PRESSURE DROPS MORE THAN.4 PSI, COMPLETELY SUBMERGE THE FLOTATION COL- LAR IN WATER TO DETERMINE WHERE LEAKAGE IS OCCURRING. IF LEAKAGE OCCURS AROUND INFLATOR, REPLACE INFLATOR GASKETS AND PERFORM LEAK TEST AGAIN. IF NO DETERMINATION CAN BE MADE OR BLADDER IS LEAKING, RETURN TO MANUFAC- TURER FOR REPAIR. 6.5 Remove trapped air by unlocking oral tube valve and depressing them. A small electric vacuum pump used with the bladder evacuation hose adapter may be used to aid in removal of the trapped air. NOTE: It is important that all the trapped air be removed to aid in the repack of the bladder assembly and to provide for a compact and low profile collar. 6.6 Lock the oral inflation tube in the closed and locked position. 6.7 Repeat steps 6.3 to 6.6 for the other side of bladder. PECI Flotation LLC Page 7

6.8 Visually inspect the case front and back, inflatable bladder, handle, attachment straps, snaps and components of the flotation collar. 6.9 Remove CO2 cylinders and weigh. If functional is performed, discard and replace. 6.10 Proceed to section 8 for packing 7. Functional Inspection A functional inspection should be performed every third year to ensure the flotation collar will perform when needed. It is the responsibility of the ALSE shop to perform and log this inspection. The inspection can also be performed at the manufacturer. If damage is found during an inspection, the vest must be grounded until repaired. Repairs are limited to replacement of snaps and inflator replacement, All other repairs must be completed at the manufacture. Functional inspection is as follows: 7.1 A functional can be performed with an individual wearing the vest with PFC-1 attached or on a table. 7.2 Pull either handle of the PFC-1 away from the bladder to inflate the flotation collar. NOTE: The PFC-1 should inflate fully within 10 seconds. 7.3 Adjust pressure to 2.0 +/- 0.1 PSI. Perform leakage test. Bladder should not loose more than.4 PSI in one (1) hour. CAUTION IF PRESSURE DROPS MORE THAN.4 PSI, COMPLETELY SUBMERGE THE FLO- TATION COLLAR IN WATER TO DETERMINE WHERE LEAKAGE IS OCCURRING. IF LEAKAGE OCCURS AROUND INFLATOR, REPLACE INFLATOR GASKETS AND PERFORM LEAK TEST AGAIN. IF NO DETERMINATION CAN BE MADE OR BLAD- DER IS LEAKING, RETURN TO MANUFACTURER FOR REPAIR. 7.4 Remove the flotation collar from the vest if applicable. 7.5 Remove trapped air by unlocking oral tube valve and depressing them. A small electric vacuum pump used with the bladder evacuation hose adapter may be used to aid in removal of the trapped air. 7.6 Proceed to section 8 for packing PECI Flotation LLC Page 8

8. PFC-1 Repack Instructions 8.1 Preparation Repack the PFC-1 on a large flat surface big enough to accommodate the bladders when they are spread flat with no air in them. NOTE: Orientation references the wearer s right and left The required equipment/tools are: Replacement CO2 cylinders, 55 gram, 1/2 thread (if needed) Auto-Inflator Green safety clip 1 each (if needed) Manual Inflator Green safety clip 1 each (if needed) Four (4) clamps with soft rubber or plastic inserts to hold the bladder while packing. 8.1.1 Deflate the bladder by unlocking both oral tube valves. Depress the valves to release the pressure. While keeping the valves pressed in, gently compress the bladder with your hands and arms. This will force the air through the oral tubes. 8.1.2 Remove the flotation collar assembly from the vest and harness. 8.1.3 Lay the flotation collar flat on the table with the underside down. Ensure that the closing zipper is fully disengaged. Spread the case open and completely lay out the bladder. 8.1.4 Remove CO 2 cylinders. Discard spent or punctured CO 2 cylinders. 8.1.5 Visually inspect the case, inflatable bladder, and components of the flotation collar. Replace damaged bladder and/or components as necessary. 8.1.6 Place the actuator levers in the up-and-armed position. Install a green safety clip on both of the actuators. 8.1.6 Installing green safety clips PECI Flotation LLC Page 9

8.1.7 Install two new CO 2 cylinders (55 gram, Min Weight 233.8 grams). Hand tighten the cylinders (avoid over tightening). 8.1.7 Install CO2 8.1.8 Close protective covers over CO2 and snap. Both sides. 8.1.8 Close CO2 cover 8.1.9 Lock the oral inflation tubes in the closed and locked position. 8.1.9 Lock oral tubes PECI Flotation LLC Page 10

8.1.10 Install light on velcro patch on bladder lobe. 8.1.10.1 Measure down the container from inside the yoke 3 inches (7.62 cm). Mark container. Put another mark 2 inches (5.08 cm) and mark again. 8.1.10.2 Measure down the light wire (from the light) 14 inches. (35.56 cm). 8.1.10.3 Tack the wire to the container seam with two (2) turns 5 or 6 cord waxed or equivalent. Tie off with surgeons knot followed by a square knot. NOTE: Wire should move freely within tacking. NOTE: Test light as per manufacturers instructions CAUTION DO NOT PIERCE WIRE WITH NEEDLE 8.1.11 Set light to manual or auto as per SOP s 8.1.10 Attach light CAUTION SETTING LIGHT TO MANUAL WILL DISABLE THE AUTO FUNCTION 8.1.12 Position the ends of the release handles in pockets and close snaps. Both sides 8.1.12 Attach handles 8.1.13 Ensure MOLLE strap routes from bladder through slot in bottom of case. Both sides 8.1.13 MOLLE strap routing PECI Flotation LLC Page 11

8.2 Folding the Bladder 8.2.1 Lay the bladder out flat on the table. Position the actuators and the oral tubes facing up. 8.2.1 Lay out bladder NOTE: Small plastic spring clamps will aid in maintaining the folds as you work on different areas of the bladder. 8.2.2 Ensure both activation lanyards are free and route from inflator through grommets. Fold Fastex buckles back on the bladder. 8.2.2 Free and clear and fold fastex WARNING ENSURE ACTIVATION LANYARDS GO DIRECTLY TO THE HANDLES AND NOT WRAPPED AROUND THE CO2 CYLINDER, INFLATOR OR FASTEX BUCKLE PECI Flotation LLC Page 12

8.2.3 Fold over the left lobe of the inflatable bladder towards the center of the assembly along a vertical line extending the length of the bladder, then fold back forming a S fold. 8.2.4 Continue to fold the remainder of the left lobe onto itself in accordion fashion. When completed, there will be a total of two (2) S type folds that are 3 inches (7.62 cm) wide as measured along the left extension. Clamp the folds to hold them in place. 8.2.5 Repeat steps for right side. NOTE: The Fastex buckles should be positioned under the first fold NOTE: Ensure both activation lanyards are free and route from inflator to grommets NOTE: Light wire should run length of case free and clear PECI Flotation LLC Page 13

8.2.6 Install the slide fastener on the left-inner zipper cord 8.2.6 Start zipper 8.2.7 Perform a 3 inch (7.62 cm) fold under so bottom edge of bladder is flush with casing. 8.2.7 Bottom fold 8.2.8 Continue to tuck the bladder, remove lower left clamp and close the case with the zipper just past the break-away portion. 8.2.8 Start left side PECI Flotation LLC Page 14

8.2.9 Fold velcro flap over break-away portion of the zipper and mate Velcro 8.2.9 Break-away flap 8.2.10 Continue to tuck the bladder, remove upper left clamp and close the case with the zipper to the corner as shown. 8.2.10 Zip left side 8.2.11 Fold the top of the bladder next. From the top of the right extension, fold the bladder over and along a 45 angle from the horizontal. 8.2.12 Repeat the previous step for the opposite side (top left lobe) PECI Flotation LLC Page 15

8.2.13 Fold the top of the bladder under and along a horizontal line approximately 3 from the top of the neckline. 8.2.14 Continue to tuck the bladder, remove upper left clamp and close the case with the zipper to the other corner as shown. 8.2.15 Close the right side, tucking in the bladder, remove the upper right clamp, past the right breakaway portion. 8.2.15 Close right side 8.2.16 Fold Velcro flap over break-away portion of the zipper and mate Velcro 8.2.16 Break-away flap PECI Flotation LLC Page 16

8.2.17 Remove lower right clamp and zip to corner. 8.2.17 Remove clamp 8.2.18 Perform fold (like opposite side) so bladder fits into case and finish zipping. 8.2.18 Finish zipping 8.2.19 Snap zipper to casing in bottom right corner. 8.2.19 Zipper snap PECI Flotation LLC Page 17

8.2.20 Tuck zipper portion into container on right lower corner. 8.2.20 Zipper tuck 9. Service Life The recommended service life is seven (7) years from date of manufacture. After five (5) years of use (placed in service) PECI recommends replacement of the device. PECI Flotation LLC Page 18

Appendix A. PFC-1 Collar Nomenclature FRONT Zipper break-away Zipper Break-away Manual Activation Handle Auto-Inflate Activation Handle Zipper closure snap Upper MOLLE Attachment Zipper tucked into container Upper MOLLE Attachment BACK ID Window MOLLE Strap (Extends from bottom of collar) MOLLE Strap (Extends from bottom of collar) PECI Flotation LLC Page 19

Appendix B. PFC-1 Bladder Nomenclature RIGHT SIDE LEFT SIDE Reflective Tape Reflective Tape Right Lobe Left Lobe Light Mouth Piece Knurled Nut Mouth Piece Knurled Nut Oral Inflation Tube Arm Strap 55g CO2 Oral Inflation Tube Arm Strap 55g CO2 Manual Inflator Auto-Inflator Activation Lanyard Reflective Tape Reflective Tape Activation Lanyard PECI Flotation LLC Page 20

Appendix C. PFC-1 Parts List Reflective Tape Item PFC- 1 Parts List Part Number PECIF- RRT2 CO2 Cartridge, 55 Gram, 1/2" Thread (1 ea) Manual Inflator Top Gasket Bottom Gasket Inflator Gasket (1/2" ) Green Safety Clip Shredder Valve Cap Nut Auto- Inflator Auto Bobbin (1 ea) Auto Green Indicator Clip Auto Manifold O- Ring Auto Manual Cap Schrader Valve Cap Nut PECIF- CO2-55 PECIF- BLA- 005 PECIF- BLA- 006 PECIF- 13227 PECIF- 8452AMA PECIF- BLA- 007 PECIF- BLA- 003 PECIF- 707100B PECIF- V707100-1 PECIF- V90113 PECIF- BLA- 040 PECIF- BLA- 007 PECIF- BLA- 003 PECI Flotation LLC Page 21

Appendix D. Manual Inflator Drawing DRAWING NO. REV MANIFOLD GASKET, NEOPR.80 DURO BODY - W/RED PAT PRINT 30% GLASS FILLED POLY- ESTER E C840AMUX Customer Drawing SPRING, ST'L STEEL MANIFOLD PIERCE PIN, ST'L STEEL O-RING, BUNA-N DURO 70 B REV D E GROOVE PIN, ST'L STEEL Revision History DESCRIPTION (ECO) DATE APPROVED ADD QTY 2 FOR TOP GASKET ECN 4069 MOVE HOTSTAMP LOCATION AS NOTED ECN 5114 6/11/09 2/16/12 INSTALL GROOVE PIN FROM THIS SIDE ONLY L.F. L.F. HOT STAMP (SEE NOTE 2) MMDDYY MANIFOLD PIERCING LEVER, ST'L STEEL 1.25 3.2cm B 1.75 4.4cm 0.64 1.6cm SECTION B-B NOTES: (2X) TOP GASKET BOTTOM GASKET 1. SUFFIX "X" INDICATES THREAD: NO SUFFIX - 3/8" TH'D 2. MM MONTH DD DAY YY YEAR L - 1/2' TH'D 3. TOP & BOTTOM GASKETS PACKED SEPARATELY. 4. CRITICAL DIMENSIONS ARE CIRCLED AND SUBJECT TO INSPECTION. 5. DIMENSIONS IN PARENTHESES ARE FOR REFERENCE ONLY. 6. ALL DIMENSIONS ARE IN INCHES WITH THE NOMINAL DIMENSION IN METRIC BELOW. MOLDED PARTS: GATES, PARTING LINES, AND FLASH PER QUALITY CRITERIA PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF HALKEY-ROBERTS CORPORATION ST. PETERSBURG, FL. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF HALKEY-ROBERTS CORPORATION IS PROHIBITED. DRAWN BY APPROVED BY MATERIAL FINISH DIMENSIONS ARE IN INCHES TOLERANCES: ANGULAR: <MOD-PM> 1<MOD-DEG> TWO PLACE DECIMAL <MOD-PM>.01 THREE PLACE DECIMAL <MOD-PM>.005 DATE L.F. 01-15-97 DATE J.W. - 01-15-97 UNLESS OTHERWISE SPECIFIED: THIRD ANGLE PROJECTION TITLE Halkey-Roberts INFLATOR, UL RECOGNIZED SIZE DRAWING NO. REV A ( WITHOUT LANYARD & TAB ) C840AMUX E SCALE SHEET DO NOT SCALE DRAWING 1:1 1 OF 1 PECI Flotation LLC Page 22

Appendix E. Bobbin Information HALKEY ROBERTS Cat. No.: V80040 R V80040 Super Bobbin Instructions for Use V80040 Super Bobbin for Manufacturers and Service Stations! Cautions: - Carefully follow the directions below to maintain the bobbin integrity. - Intended for use in Halkey-Roberts Corp. products only. Safely Handling: 1. The white pill material is a pharmaceutical grade Microcrystalline Cellulose, typically used as the filler in medicine tablets, ill. 1. The pill formulation is considered proprietary. 2. The MSDS for the yellow bobbin is provided under separate cover. Operation: 1. The V80040 Bobbin Assembly is designed to disintegrate when exposed to water. This allows the firing mechanism to puncture the CO2 cylinder and fill the inflatable chamber. 2. To insure consistent service from your manual/automatic inflator the bobbin should be changed at regular Halkey-Roberts recommended intervals or replace bobbin more frequently in extreme conditions, i.e. high temperature and high humidity. 3. Install V80040 Bobbin Assembly with the white pill facing the cap of the inflator, ill 1. The Bobbin Assembly will slide in easily if installed correctly. 4. Shelf life plus service life not to exceed six (6) years from Date Code, ill 2. Replace (Discard) bobbin within a maximum of six (6) years from Date Code. Shelf life: 1. See tables below, use Date Code printed on side, ill. 2. 2. Bobbin must be stored in a cool dry environment. ( 65 ºF to 85 ºF, 19 ºC to 29 ºC; Maximum 60 %RH) 3. Service life begins when bobbin is removed from a cool dry environment or when bobbin is installed in an inflator, which ever comes first. Recreational use: Shelf Life (years) Service Life (years) V86000 Pro -1F Inflator three (3) three (3) V85000 Mark IV three (3) three (3) V90000 Alpha Inflator three (3) three (3) Commercial use: Shelf Life (years) Service Life (years) V86000 Pro -1F Inflator four (4) two (2) V85000 Mark IV five (5) one (1) V90000 Alpha Inflator five (5) one (1) illustration 1 illustration 2 White Pill Yellow Bobbin US Patent 7,572,161 and Foreign Patents Pending or Issued. HALKEY ROBERTS, HR, Pro -1F and Alpha Inflator are registered trademarks of the Halkey-Roberts Corporation. Made in the USA JUN30 09 HR Date Code Month Day Year Halkey-Roberts 2700 Halkey-Roberts Pl. N. St. Petersburg, FL 33716 USA 727.471.4200 www.halkeyroberts.com sales@halkeyroberts.com IFU-V80040-B Rev. A PECI Flotation LLC Page 23

Appendix F. Auto-Inflator Technical Data Sheet ALPHA SERIES INFLATOR ALPHA SERIES INFLATOR GENERAL CHARACTERISTICS Designed for use on life vests where automatic (immersion) back up is desirable Easy and inexpensive to rearm requires only a CO 2 cylinder and a bobbin Improved splash resistance Improved humidity resistance Unit body design for increased strength Left or right side mounting Uses the super bobbin Manifold O-rings assembled on unit Higher flow over previous model for quicker vest inflation Exceeds all UL, CEN, and ISO standards UL recognized as a USCG Code 6 device Meets UL 1191 1F humidity standard highest in the industry PERFORMANCE CHARACTERISTICS Operating temperatures: 0ºC. 70ºC Corrosion resistance (720 hours of salt spray) UV protection 300 hours of accelerated weathering Tested for 100 inflations V90000 ALPHA INFLATOR QUALITY CRITERIA 100% inspected for leak and functionality ISO 9001-2000 ALPHA SERVICE PART NUMBERS V90113 Manifold O-Ring (2) V87403L ½" Threaded Gasket V90124 Indicator Clip V80040 Bobbin MATERIALS Glass reinforced nylons All metal components stainless steel for the marine environment PACKAGING AND SHIPPING Minimum shipping one box 100 units per box Box size 12" x 10" x 8" Weight 16 pounds PECI Flotation LLC Page 24

Appendix G. Auto-Inflator Drawing DRAWING NO. REV CV90000XN135 B Customer Drawing INFLATOR BODY MANIFOLD O-RING REV Revision History DESCRIPTION (ECO) DATE APPROVED A NEW DRAWING ECN 3989 5/12/09 A.K. B UPDATE NOTES, ADD CORD LENGTH & DIM'S ECN 4189 9/29/09 AK 1.50 3.8 cm 1/2" THD GASKET 3/8" THD GASKET CAP ASSY. PIERCE PIN SPRING PIERCE PIN ASSY. IMPACT SHAFT ASSY. SECTION A-A COILED SPRING PIN FRENCH LEVER/LANYARD 13.5 0.25 34.3 cm V90124 INDICATOR CLIP SEE NOTE (1) TOOLING: PART NO. IFU: ----- ---- IFU -V80040B NOTES: V90000LABS1F SEE NOTE (1) V90000LABS2 SEE NOTE (1) 1. INDICATOR CLIP AND LABELS PACKED SEPERATELY. 2. FIRST SUFFIX "X" INDICATES THREAD TYPE: NONE - 1/2" S - 3/8" 3. CRITICAL DIMENSIONS ARE CIRCLED AND SUBJECT TO INSPECTION. 4. DIMENSIONS IN PARENTHESES ARE FOR REFERENCE ONLY. 5. ALL DIMENSIONS ARE IN INCHES WITH THE NOMINAL DIMENSION IN METRIC BELOW. MOLDED PARTS: GATES, PARTING LINES, AND FLASH PER QUALITY CRITERIA PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF HALKEY-ROBERTS CORPORATION ST. PETERSBURG, FL. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF HALKEY-ROBERTS CORPORATION IS PROHIBITED. DRAWN BY APPROVED BY MATERIAL FINISH DATE DMC 5/12/09 DATE A.K UNLESS OTHERWISE SPECIFIED: THIRD ANGLE PROJECTION DIMENSIONS ARE IN INCHES TOLERANCES: ANGULAR: 1 TWO PLACE DECIMAL.01 THREE PLACE DECIMAL.005 TITLE Halkey-Roberts ALPHA INFLATOR SIZE DRAWING NO. REV A CV90000XN135 B SCALE SHEET 1:1 DO NOT SCALE DRAWING 1 OF 1 PECI Flotation LLC Page 25

Appendix H. Auto-Inflator Rearm Instructions DISASSEMBLY (see figure) Step 1: Unpack or open the life vest so that the manual / automatic inflator is visible. ALPHA V90000 INFLATOR SERVICE INSTRUCTIONS clockwise Step 2: Remove gas CO 2 cylinder by firmly rotating cylinder counterclockwise. Discard cylinder. Step 3: Remove clear cap by turning counterclockwise. Step 4: Remove bobbin from cap or housing unit. Discard bobbin (yellow). Check the housing to be sure it is clear and dry. CO2 cylinder Step 2 Step 8 Note: The bobbin (yellow) body may remain in the housing or in the cap assembly when you remove the cap. The bobbin body must be removed prior to assembly. REARMING Note: Rearming must follow the sequence below. Step 5: Check the date on the bobbin in the rearm kit. The date should not be over four (4) years from today s date. Step 6: IMPORTANT! Bobbin (yellow) must be installed into the HOUSING (**see figure), white side down facing away from the inflator towards the cap (clear), aligning the slots on the bobbin with the ridges inside the threaded housing. The bobbin will slide in easily if installed correctly. Step 7: Install cap by screwing clockwise until it meets the housing shoulder. Note: No gap. Step 8: Install cylinder by rotating clockwise into inflator until cylinder is secured firmly in inflator. Step 9: Place indicator clip over red lever by aligning the arms on the clip with the slots in the inflator. Push firmly in the middle of the clip to snap in place. Step 10: Check to be sure service indicator is green and green indicator clip is firmly attached. **HOUSING Step 6 Bobbin (yellow) Step 5 Step 6 Red lever Step 9 Cap (clear) Step 3 Step 7 Step 10 Service Indicator Step 10 If red, stop and service unit. Indicator clip Step 9 If green and clip is present, unit is operable. HRC Rev D 11-2006 PECI Flotation LLC Page 26

Appendix I. Inflator Assembly Instructions HALKEY ROBERTS GROOVE R 830011001 Brass Manifold Instructions for Use 830011001 Brass Manifold for Manufacturers and Service Stations Cat. No.: 830011001, 830010101, 830013001, 830014001, 830AOE, 830AOEU, 833AOI, 8491AM, 8492AM, 830AOISC, 831AOISCLN Cautions: - To prevent valve damage, Follow proper torque settings. - Carefully follow the directions below to maintain the valve integrity. Installation 840 Inflator (ill. 1): 1. Install valve core (P/N 832AO) in manifold and torque to 1.5-2 in-lb., with a calibrated torque wrench. 2. Install bottom gasket (P/N 8492AM) on manifold until it is retained in groove. * Note always use new gaskets when installing inflator. 3. Install 840 inflator on manifold, aligning flats. 4. Install top gasket (P/N 8491AM) on manifold. 5. Screw cap on manifold. 6. Retain ( secure ) inflator and torque Cap to 24-30 in-lb., with a calibrated torque wrench. Installation Alpha Inflator (ill. 2): 1. Install valve core (P/N 832AO) in manifold and torque to 1.5-2 in-lb., with a calibrated torque wrench. 2. Check inflator to make sure o-rings are installed on both sides. 3. Install Alpha Inflator on manifold, aligning flats. 4. Screw cap on manifold. 5. Retain ( Secure ) Inflator and torque cap to 24-30 in-lb. with a calibrated torque wrench. illustration 1 illustration 2 CAP TOP GASKET VALVE CORE 840 INFLATOR BOTTOM GASKET MANIFOLD O-RING 2 SIDES CAP VALVE CORE ALPHA INFLATOR MANIFOLD Made in the USA 2011 HALKEY-ROBERTS Halkey-Roberts 2700 Halkey-Roberts Pl. N. St. Petersburg, FL 33716 USA 727.471.4200 www.halkeyroberts.com sales@halkeyroberts.com IFU-830011001 Rev. E PECI Flotation LLC Page 27