Performance Literature for 60DJ, 80DJ & 150DJ Gas Pressure Regulators ¼, ⅜ and ½ Sizes. Catalogue

Similar documents
Performance Literature for J78. Gas Pressure Regulators ½, ¾ and 1 Sizes. Catalogue

Performance Literature for J48. Gas Pressure Regulators 2½ 6 Sizes. Catalogue

J48 Gas Pressure Regulator. Technical Bulletin

Gas Pressure Regulator HON 270 MK2

Model 1800 PFM Series Regulator. Technical Bulletin

Safety Cut-Off Valve HON 305

Gas Filters DN15 DN300. elektrogas.com EE151 06/13

Gas Pressure Regulator HON 280H - 309

Type R622 Pressure Reducing Regulator

HUPF Series DESCRIPTION APPLICATION INSTRUCTION SHEET GAS PRESSURE REGULATOR WITH INCORPORATED FILTER EN1C-0003NL05 R1205.

RR 16 Commercial & Industrial Regulator

RR 16 Commercial & Industrial Regulator

SR100 Series Service Regulators. Technical Bulletin

Aperval Pressure Regulators

Precision and Instrument Regulators 1/4" port size

Pressure ranges and accuracy classes for outlet pressure and safety devices

Gas Appliance Pressure Regulators with integrated gas filter. FRI/6 Series

MODEL 273PL GAS PRESSURE REGULATOR

Norval Pressure Regulators

Fuel Filters DN15 DN25. elektrogas.com DE

S300 Series. Valve Link. Features. Fisher Controls

Gas Appliance Pressure Regulators with integrated gas filter. FRI/6 Series

T208VR Series Tank Blanketing Vacuum Regulator

1800CPB2 Pilot-Loaded Service Regulators

Gas Pressure Regulator HON 502

MODEL 274 GAS PRESSURE REGULATOR

Line Pressure Regulator. Class I or Class II. FRS 7../6 Series

Noth American 7347 High Pressure Gas Regulators

Line Pressure Regulators Class I or Class II. FRS 7../6 Series

Safety Shut-off Valve SSV

Pilot HON 625. Entwurf. Product information. serving the gas industry worldwide

ALE-32. Miniature General Purpose Regulators R07, R46 (non-repairable) Air line equipment. Technical data

Standard & Braided Gas Hoses, Safety Options & Regulators

Dival 600. Pressure Regulators

Ratio Regulator Zero Governor. FRG/6 Series

1800C and 1800C-HC Service Regulators

Safety shut-off valve S 50. Product information

Cash Valve TYPE G-4 PILOT OPERATED PRESSURE REDUCING REGULATOR FOR STEAM, AIR AND GASES. ISSUED - MARCH 2001 CAVMC-0512-US-0208 ISO 9001 Certified

Series 100 Slam Shut Valve. Technical Bulletin

1800CPB2 Service Regulators Maximum Inlet Pressure 125 PSIG

OPERATING INSTRUCTIONS

Gas Pressure Regulator Series 277 Hi-Flo

Gas Pressure Regulator R 51

PRO-50 Instrument Supply Regulator

RB 4700 Commercial & Industrial Regulator

Gas Filters DN15 DN300. delta-elektrogas.com EE151 03/17

CL31 Series Commercial Regulator. Advanced Metering and Regulation Technology at Work.

1800CPB2 Service Regulators

Gas Pressure Regulator HON 300

EXCELON QUIKCLAMP SYSTEM Pressure relief valves V72G, V74G - G1/4... G 3/4

Pilot HON 630a, HON 640

MULTIFUNCTIONAL CONTROL FOR GAS BURNING APPLIANCE

MODEL 240 GAS PRESSURE REGULATOR

Issue 1. Air Valves OUR GENIUS IS FITTINGS.

Type 299 Pressure Reducing Regulators


Gas Appliance Pressure Regulators and. Line Pressure Regulator. FRS 7../6 Series FRS 5... Series

QUICK CONNECT FOR 2.0, 4.0 & 5.0 GASES

ASX 176 Axial Pressure regulator

Cash Valve. Type G-4. Pilot Operated Pressure Reducing Regulator for Steam, Air and Gases. Flow Control

1800C and 1800C-HC Series Service Regulators

GAS PRESSURE REGULATORS AP

Pressure Reducing Valves Pressure Reducing with. Broady Flow Control. D Series Range. Pressure Reducing Valves. Broady Flow Control

Slam Shut Valves SCN

C 10 Pressure Reducing Valve

CLASS TLP Pressure Reducing Valve

1200 Series Pressure Regulators

About. providing superior performance and reliability. Bromic regulators are AGA or UL144 approved.

Gas Pressure Regulator HON 505

B34 Series Regulator Commercial and Industrial Regulator

Pressure regulators. Introduction. TR Head. 3 ways body Dival

A rising main is a system of pipe work and valves that enables water to be delivered for fire fighting purposes to all floors in buildings over 18

RESIDENTIAL REGULATORS

ALE-40. R06 Miniature Brass Body Regulator. Water and Compressed Air Service 1/8" and 1/4" PTF Port Sizes. Air line equipment.

Product Data Screwed Valves

Dual Modular Safety Shutoff Valves DMV-D 525/11 DMV-DLE 525/11

Safety shut-off valve Control Control Lock-up Over pressure set point Under pressure set point pressure range accuracy class

RTG 25. Introduction

High Performance BSP Dial Up Pattern Pressure Reducing Valve

Dual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure. DMV-D/624L Series DMV-DLE/624L Series

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

Safety shut-off valve S 100. Product information

IX1 Spirax-Monnier International Compressed Air Filter Installation and Maintenance Instructions

Regulator from 1800 B series

Directional Control Valves Series VA13 and VA15 3- and 5-port valves, G1/8

SCA Series Inverted Bucket Steam Traps

Model 1800 PFM Series Regulator For Constant Outlet Pressure Precise Fixed Factor Measurement From 0.5 to 30 PSIG

Pressure Regulators. Aperflux 101

PRESSURE REDUCING VALVE RP45 (EN)

Pressure Reducing Valves Pressure Reducing with. Broady Flow Control. C Series Range. Pressure Reducing Valves. Broady Flow Control

Series MX pressure regulators 3/

1301 Series High-Pressure Regulators

Dual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure. DMV-D/624L Series DMV-DLE/624L Series

Safety Relief Valve HON 832

Precision pressure regulators LRP/LRPS

Solenoid valves VZWF, force pilot operated

1200B2 Series Service Regulators. Instruction Manual

Gas Pressure Regulator HON 200

Safety Shutoff Valves MVD/6 Series MVDLE/6 Series

Dual Modular Safety Shutoff Valves with Two-stage operation. DMV-ZRD/602 Series DMV-ZRDLE/602 Series

Transcription:

Catalogue and Performance Literature for 60DJ, 80DJ & 150DJ Gas Pressure Regulators ¼, ⅜ and ½ Sizes Catalogue General Information Regulating Capacity Flow Capacity Figures Full Open Capacity Flow Capacity Figures Performance Graph Full Open Capacity CSAPP01F DSAPP01D DSAPP02C GAPP01A June 2005

¼ - ½ Suitable for inlet pressures up to 100mbar (40 wg). The Elster Jeavons APPLIANCE Regulators are compact and economical. They are suitable for a wide range of domestic appliance and pilot pressure control applications. They are available in a number of sizes up to ½". APPLICATION This range of regulators is suitable for domestic appliance and pilot applications with inlet pressures up to 100mbar (40"wg). They comply with the Essential Requirements of the European Gas Appliance Directive (90/396/EEC). All units are designed for natural, liquified petroleum and manufactured gases and can be installed in vertical or horizontal pipelines. PRESSURE Maximum Inlet Pressure: 100mbar (40"wg). Maximum Outlet Pressure: Please refer to spring table. CONTROL The outlet pressure can be easily and accurately adjusted by turning the spring adjustment unit located under the top cap. On the 60DJ and 80DJ the cover and top cap are drilled so that a sealing wire can be easily fitted if required. SIZES 60DJ - 1/4" 80DJ - 3/8" 150DJ - 1/2" TEMPERATURE These appliance regulators are suitable for operation in a wide range of temperatures from -20 C to +70 C. CONNECTIONS As standard the 150DJ is supplied with a tapered screwed thread. The 60DJ and 80DJ are supplied with a parallel screwed thread, both threads are to BS21 (ISO 7). Other threads may be available upon request. DATASHEET CSAPP01 ISSUE F SEPTEMBER 2000

A Square C B D DIMENSIONS & WEIGHTS UNIT A B C D Weight 60DJ 51 53 12 64 110g 80DJ 51 53 13 64 115g 150DJ 65 61 15 88 180g MATERIAL SPECIFICATION A summary of the material specification for the regulator is given for reference. All material has been selected to provide maximum durability and reliability of operation. Components Body, cover and top cap. Valve assembly & spring holder Diaphragm Springs Aluminium Alloy Acetal Resin Nitrile Synthetic Rubber Specification Carbon steel, zinc plated & passivated, or phosphor bronze QUALITY Elster Jeavons is committed to a programme of continuous quality enhancement. All equipment designed and manufactured by Elster Jeavons benefits from the company s quality assurance standards which are approved to BS EN ISO9001:1994. Elster Jeavons has a programme of continuous product development and improvement and in consequence the information in this leaflet may be subject to change or modification without notice. PERFORMANCE Detailed performance data is provided on separate technical datasheets. SPRINGS mbar wg 60DJ / 80DJ 150DJ 5 17.5 2 7 J6002D-026 J150D-024 12-25 5-10 J150D-027 DATASHEET CSAPP01 ISSUE F SEPTEMBER 2000 ELSTER JEAVONS Ltd. Tel: +44 (0)121 557 3911 Lower Church Lane, Tipton Fax: +44 (0)121 520 9556 West Midlands DY4 7PH England Email: info@jeavonsltd.co.uk

REGULATING CAPACITIES All capacities in SCMH 0.64 s.g. 60DJ REGULATOR: SIZE ¼ Pin mbar OUTLET PRESSURE SETTING (mbar) / DROOP (%) Setting Flow Rate: 0.6 SCMH 5 10 15 10% 20% 10% 20% 10% 20% 7 0.90 1.15 - - - - 12 0.98 1.26 1.09 1.58 - - 15 1.01 1.34 1.26 1.89 - - 20 1.04 1.41 1.40 2.11 1.43 2.31 25 1.08 1.44 1.44 2.15 1.54 2.49 35 1.10 1.49 1.51 2.38 2.08 3.14 53 1.14 1.56 1.56 2.40 2.10 3.19 70 1.16 1.61 1.64 2.68 2.14 3.26 80DJ REGULATOR: SIZE ⅜ Pin mbar OUTLET PRESSURE SETTING (mbar) / DROOP (%) Setting Flow Rate: 1.1 SCMH 10 17.5 10% 20% 10% 20% 12 1.62 1.91 - - 15 1.65 1.97 - - 20 1.64 2.01 1.91 2.59 25 1.66 2.05 2.11 2.80 35 1.70 2.15 2.19 2.94 53 1.84 2.20 2.18 3.00 70 1.84 2.20 2.20 3.02 150DJ REGULATOR: SIZE ½ Pin mbar OUTLET PRESSURE SETTING (mbar) / DROOP (%) Setting Flow Rate: 1.25 SCMH 5 10 15 17.5 20 10% 20% 10% 20% 10% 20% 10% 20% 10% 20% 7 1.9 2.5 - - - - - - - - 12 2.1 3.0 2.6 3.9 - - - - - - 15 2.2 3.0 2.9 4.4 - - - - - - 20 2.4 3.3 3.0 4.5 3.4 5.2 2.8 4.4 - - 25 2.4 3.4 3.3 5.1 3.6 6.0 3.1 5.0 3.4 5.1 35 2.5 3.4 3.5 5.5 3.7 6.4 3.7 6.0 3.7 6.4 53 2.3 3.4 3.5 5.6 3.9 6.7 4.1 6.2 3.9 6.8 70 2.1 3.5 3.7 5.6 4.2 7.2 4.4 7.0 4.0 7.1 DATASHEET DSAPP01 ISSUE D JULY 2004

The tests on the previous page are performed with the regulator set at a constant inlet pressure, a predetermined flow rate and the required outlet pressure. The flow rate is then increased whilst keeping the inlet pressure constant. The capacities are recorded when the outlet pressure has fallen by 10% and 20% from the set point. The capacities are for natural gas (0.64 SG). For other gases multiply the capacity by: 0.64 4 gas sg GAS SG Air 1.00 Towns Gas 0.50 Propane 1.53 Propane / Air 1.20 DATASHEET DSAPP01 ISSUE D JULY 2004 ELSTER JEAVONS Ltd. Tel: +44 (0)121 557 3911 Lower Church Lane, Tipton Fax: +44 (0)121 520 9556 West Midlands DY4 7PH England Email: info@jeavonsltd.co.uk

FULL OPEN CAPACITY All capacities in SCMH 0.64 sg 60D, 80D, 150D FLOW RATE VERSUS PRESSURE DROP For the data below the regulator was physically held open. With the outlet pressure at atmospheric the listed full open capacities were set through and the pressure drop recorded. PRESSURE DROP (mbar) Size FLOWRATE (SCMH) ¼ 60DJ ⅜ 80DJ ½ 150DJ K Factor 0.021 0.023 0.057 1 1.1 0.9 0.1 2 4.3 3.7 0.6 3 9.7 8.4 1.3 5 26.7 23.1 3.7 7 51.7 44.7 7.3 10 - - 14.8 15 - - 33.0 20 - - 58.0 PRESSURE DROP VERSUS FLOW RATE For the data below the regulator was physically held open. With the outlet pressure at atmospheric the listed pressure drops were set through and the full open capacities recorded. CAPACITY (SCMH) Size PRESSURE DROP (mbar) ¼ 60DJ ⅜ 80DJ ½ 150DJ K Factor 0.021 0.023 0.057 1.0 1.0 1.0 2.6 3.0 1.7 1.8 4.5 5.0 2.2 2.3 5.8 10.0 3.0 3.3 8.2 15.0 3.7 4.0 10.1 20.0 4.3 4.7 11.6 30.0 5.3 5.7 14.3 40.0 6.1 6.6 16.5 60.0 7.6 8.1 20.3 DATASHEET DSAPP02 ISSUE C AUGUST 1997

The capacities on the previous page are for natural gas (0.64 SG). For other gases multiply the capacity by: 0.64 4 gas sg GAS SG Air 1.00 Towns Gas 0.50 Propane 1.53 Propane / Air 1.20 If the tables on the previous page do not provide sufficient information a formula is provided to calculate the fully open capacity for all sizes of regulator at any pressure drop. It is not possible to provide formula for calculating the regulating capacity as this data relates to a dynamic condition which can only be provided by actual test. Regulating capacity tables are available on another data sheet. The full open formula is: Q = K (Pi 2 - Po 2 ) Where: Q = Flow rate corrected to standard pressure and temperature conditions (SCMH). Pi = Inlet Pressure (mbar absolute units) Po = Outlet Pressure (mbar absolute units) K = Flow constant for each size of regulator (see table). PRESSURE DROP The natural loss of pressure from the inlet to the outlet of a regulator due to friction in the full open condition. PRESSURE DIFFERENTIAL The difference between the working inlet pressure to a regulator and the working outlet pressure from a regulator. DATASHEET DSAPP02 ISSUE C AUGUST 1997 ELSTER JEAVONS Ltd. Tel: +44 (0)121 557 3911 Lower Church Lane, Tipton Fax: +44 (0)121 520 9556 West Midlands DY4 7PH England Email: info@jeavonsltd.co.uk

100 60DJ, 80DJ & 150DJ Appliance Regulators Full Open Capacity Pressure Drop (mbar) 10 1.0 60DJ 0.1 80DJ 150DJ 0.01 0.1 1.0 10 100 Flow Rate (SCMH 0.64 sg) DATASHEET GAPP01 ISSUE A AUGUST 1997