MP15 Jockey Pump Controller

Similar documents
DPC-30 DPC-100. Reference Manual

Race Screen: Figure 2: Race Screen. Figure 3: Race Screen with Top Bulb Lock

PROPORTIONING VALVE. Model 150 INSTRUCTION MANUAL. March 2017 IMS Company Stafford Road

BUBBLER CONTROL SYSTEM

AFDXXX(X)AC Series Operators Manual Please read this manual thoroughly before attempting to operate your water maker.

Touch Screen Guide. OG-1500 and OG Part # T011

ACV-10 Automatic Control Valve

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

Copyright 2004 by the Thomas G. Faria Corporation, Uncasville CT No part of this publication may by reproduced in any form, in an electronic

RAM 4021 Operation Manual

RAM 4021-DPX Operation Manual

Quickstart Installation Checklist (Please refer to operation manual for complete installation instructions)

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

BUBBLER CONTROL SYSTEM

FireHawk M7 Interface Module Software Instructions OPERATION AND INSTRUCTIONS

ELIMINATOR INSTRUCTIONS Table of Contents

GV Standard X-Vent. Setup, Commissioning & Installation Guide

FAULT CODE TROUBLESHOOTING INDEX

WELCOME TO THE REVOLUTION

LENNOX SLP98UHV DIAGNOSTIC CODES

A TECHNICAL REFERENCE

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

Portable Gas Monitor GX User Maintenance Manual (H4-0050)

ECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION

UBEC 1AT. AUTO TANK Fill System Installation, Operation, & Setup Instructions

ECL Comfort 110, application 131 (valid as of software version 2.00)

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

SPECIFICATIONS ATTENTION

! Warning, refer to accompanying documents.

AHE58/59 AC Servo System

Declining Weight Blending System Quick Start Manual E Main St Marshall, IL Phone: Fax: Website:

NGP-250/500 Nitrogen Generator Quick Start Guide

Operating Instructions Part No

BRILLIANT WONDERS LED BUBBLERS INSTALLATION INSTRUCTIONS & PRODUCT MANUAL CMP SERIES

Model 130M Pneumatic Controller

D10S/D20S Wall/Post Mount Inflator Quick Start Manual

Temperature Controller CC24-7 ULTRA USER S MANUAL Legion Dr. Mason, MI USA October 2010 Ph. (517) Fax (517)

Operating instructions Electrical switching facility pco

September 10, 2014 Revision 2. Puncher Unit-BE1/BF1/BG1/BH1 Service Manual

Roller AC Servo System

Operating Instructions

BRILLIANT WONDERS LED BUBBLERS INSTALLATION INSTRUCTIONS CMP SERIES. Brilliant Wonders LED BUBBLERS

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

Inspection Recommendations

CONSOLE-320 ENGLISH. 230A: CONSOLE-320 with cable data output Item 230B: CONSOLE-320 with cable + wireless radio data output

TANK MANAGER FOR TWO TANKS OPERATING MANUAL. 10/31/11 C-More T6C L color touch panel

CCT-7320/ROC-2313 Reverse Osmosis Controller

Automatic Valve Proving Control

OC Panel High Limit Aquastat Kit, Manual Reset p/n

RAM Operation Manual

Smart JVA Module WARNING. For use with AquaLink RS systems with rev R firmware or newer.

SG33KTL-M Quick Installation Guide. 1 Unpacking and Inspection

SG36KTL-M Quick Installation Guide. 1 Unpacking and Inspection

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

PERFORM Operating Document

Pneumatic high-pressure controller Model CPC7000

Using the UltraRAE. Firmware 2.35

ELIMINATOR COMPETITION DRAG RACE Program Manual Firm Ver 4.11

6800 Maintenance Instruction System Flush Procedure

HyperSecureLink V6.0x User Guide

Norrsken Family Booklet

Reverse Osmosis System Installation Guide and Operation Manual.

WATER CONTROL SYSTEM QUICK START

PTG100 Precision Test Gauge

Viva TPS. TS11/15 Total Stations Check and Adjust Procedure. October Summary

User s Guide Temperature Sensor Converter TSC-599

Pneumatic high-pressure controller Model CPC7000

JOLLY2. Installation user s manual. 6 different operating modes selectable. version 3.3. DATA TO BE FILLED OUT BY THE INSTALLER (Page 1)

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

In Vivo Scientific, LLC INSTRUCTION MANUAL

OPERATING INSTRUCTIONS FOR

A4s Operation Manual

HPICAL Operation & Data Logging Procedures. Click spacebar to advance through slides 1

New product release. Universal Rebreather Monitor (URBM) Three cell / Independent backup

Sweeper Dual Control. Automatic Sweeper Switching System SW SERIES SWEEPERS SW-4815 SW-4820 SW-4825 MAGUIRE PRODUCTS INC.

OPERATION MANUAL BFX-2

New AQF Filter Polymer Filtration System

Instructions for Use

Installation Instructions

Misaligned Folds Paper Feed Problems Double Feeds Won t Feed FLYER Won t Run iii

A4 Operation Manual. Fig.1-1 Controller Socket Diagram

BGA244 Binary Gas Analyzer

WSN: XXXXXX 101 ROME COURT FORT COLLINS, CO, PHONE #: (970) FAX #: (970) TO-Clean Manual

MONSOON 6V Pump Control System

OFI MODEL 20 CONSTANT SPEED BLENDER INSTRUCTIONAL MANUAL

USER MANUAL. JET TST and JET TST S.

AUTOMATIC TIRE INFLATOR # MW-60, MW-60-4WAY & MW-64HP

Municipal Boost w/pre-treatment Monitoring System K-A-MCB-PRE

Approach. S3 Owner s Manual. May _0B Printed in Taiwan

Installation and operating manual. Pneumatic control station LK product no: PCS 1-10

Control units. Installation and operating instructions Series: DP-Control

Differential pressure switch / Lube oil protection control MP 54 and MP 55

PERFORM Operating Document

Stand-Alone Bubble Detection System

LED CONVERSION BOARD - YAKUZA SERIES EGO/GEO

444C DUAL PERFORMANCE VALUE PACK

Aquavar SOLO 2 Frequently Asked Questions

HEAT-TIMER CORP. 20 NEW DUTCH LANE FAIRFIELD, NEW JERSEY TEL. (973) FAX (973) INSTALLATION & OPERATION MANUAL TABLE OF CONTENTS

Theatre Control Panel. Instructions for Use. January 2017 ASF-29 (1)

System 6 Water Polo. For the System 6 Sports Timer Software User Guide. F872 Rev

Transcription:

Setup and Operating Instructions MP15 Jockey Pump Controller This manual provides general information, installation, operation, maintenance, and system setup information for Metron Model MP15 Jockey Pump Controllers. Section Page Introduction 2 Installation 3 Operation of the Controller 5 Operator Interface Device (OID) Use and Navigation 7 System Set Point Definitions 12 Test Procedure 14 Alarm and Event Log Messages 15 Disposal 16 Replacement Parts & Technical Support 17

2 MP15 Jockey Pump Controller Introduction Metron MP15 Jockey Pump Controllers are microprocessor based controllers intended for use with the main fire pump system. The jockey pump's purpose is to help maintain normal water pressure and prevent unnecessary cycling of the main fire pump(s). Approvals Metron MP15 controllers are listed by Underwriter's Laboratories, Inc., in accordance with UL508A, Standard for Industrial Controls; and CSA, Standard for Industrial Control Equipment (cul). NOTICE Read these instructions thoroughly before installing and operating the controller. If there are still questions, contact your Metron factory representative for assistance.

MP15 Jockey Pump Controller 3 Installation The controller has been assembled and wired at the factory with the highest workmanship standards. All wiring and functions have been thoroughly tested to ensure correct operation when properly installed. Receiving, Handling, and Storage 1. Immediately upon receipt, carefully unpack and inspect the controller for damage that may have occurred in shipment. If damage or rough handling is evident, file a damage claim with the transportation carrier immediately. 2. If the controller must be stored, cover it and then place it in a clean, dry location. Avoid unheated locations, where condensation can result in damage to the insulation or corrosion of metal parts. Precautions CAUTION To avoid risk of SERIOUS INJURY or DEATH, and to avoid damage to the controller, READ THIS SECTION CAREFULLY. If questions or concerns still exist, contact the Metron factory for further clarification. If work must be carried out on the motor or controller, ensure the controller is ISOLATED AND LOCKED OFF from the AC mains supply before work commences. Lockout/Tag out procedures should be followed in accordance with OSHA standard and any local standards that may apply. During installation and maintenance, to prevent automatic starting of the motor ensure the controller HOA Switch is in the Off position. To avoid risk of serious electric shock, never energize the controller with the access door open unless absolutely necessary. If the access door to the interior of the panel has to be opened when the panel is energized, take caution that high voltage is present. Installation Instructions Mounting The controller should be mounted using appropriate fixing methods:

4 MP15 Jockey Pump Controller A. If the controller is mounted directly to the pump skid, anti-vibration mounts should be used. B. If the controller is mounted to a wall, it should use the four (4) external mounting holes of the controller cabinet. Suitable fixings to the wall should be used taking into consideration the weight of the controller. It is recommended that the controller be mounted at least 12 inches (300mm) above floor level. Electrical Connections DANGER SHOCK HAZARD Electric shock may result in SERIOUS INJURY OR DEATH. Electrical connections should be made by a qualified electrical engineer only. Refer to Field Connection drawing supplied with the controller. The installer is responsible for ensuring no metallic foreign objects (such as drilling chips, etc.) fall inside the controller onto the electrical circuit. Failure to observe this could result in damage to the controller and will void the controller warranty. The cabinet should be properly grounded per the requirements of NFPA 70. NOTE: It is highly recommended, although not essential, that the following recommendations are considered: o All signal wiring should be separated from power feeds and supplies. Where the two must be in close proximity, it is advisable that they are located at right angles to each other. o Signal wiring will be less prone to disturbances if contained within grounded conductive conduit or trunking. Avoid passing signal cables in close proximity of known interference sources, or high power electrical equipment where possible. o Refer to the Field Connection diagram for wiring sizes.

MP15 Jockey Pump Controller 5 Operation of the Controller General Information The primary function of a Jockey Pump Controller is to maintain normal system pressure which may fluctuate slightly due to small leaks in the system. The use of this small pump will eliminate frequent starting of the main pump. The Jockey Pump Controller automatically starts the Jockey Pump Motor when the system pressure drops below a user configured level. Operator Interface Device (OID) OFF HOA Selector HAND AUTO 1 2 3 Disconnect Switch Drawing not to scale Figure 1: Typical front view of MP15

6 MP15 Jockey Pump Controller Functions Disconnect switch - Controls jockey pump main power. Can be padlocked in the "OFF" position. Operator Interface Device (OID) Provides visual indication of system pressure, alarms, events, and system messages. Hand-Off-Auto (HOA) Selector switch. o Hand - Manually starts the jockey pump. o Off - Manually stops the jockey pump. o Auto - Jockey pump starts and stops automatically. USB port for recording alarm and event data log records to a USB memory stick. Sequence of Operation The explanation of the Sequence of Operation will start with the assumption that the controller has been properly installed, all external connections have been made, and the Motor Starter Protector is closed. Manual Operation To manually start the jockey pump motor, turn the HOA Selector to the Hand position. This will cause the Motor Contactor contact to close, thus starting the motor. To manually stop the motor, turn the HOA Selector to the Off position, thus causing the Motor Contactor contact to open. Automatic Operation For automatic operation of the jockey pump motor, turn the HOA Selector to the Auto position. When the system pressure drops below the user configured Start Pressure, the Motor Contactor contact will close, thus starting the motor. The controller will automatically open the Motor Contactor contact once the system pressure rises to or above the user configured Stop Pressure, and the Minimum Run Timer is either disabled or expired.

MP15 Jockey Pump Controller 7 Operator Interface Device (OID) Use and Navigation The Operator Interface Device (OID) provides visual indication of the alarms, status of system parameters, and an interface for adjusting set points to configure the MP15. Power Available LED Pump Running LED Enter Button 1 2 3 Down Button Up Button Drawing not to scale Using the OID Controls There are three types of windows displayed on screen: Figure 2: Operator Interface Device (OID) Informational, such as the home window. Menus, which navigate to a sub-list of windows. They are denoted onscreen with an arrow to the right of the text. Set Points, which display the set point name and its current value. Use the E N T E R, U P, and D O W N buttons to navigate through onscreen menus, change set points, and view system information. To Go to the next window Go to the previous window Choose a menu item Go back to the previous menu Do this Press the D O W N button. Press the U P button. Press the E N T E R button. Press the U P and D O W N buttons simultaneously.

8 MP15 Jockey Pump Controller To Edit a set point value Cancel editing a set point value Return to the Home window Do this Press the E N T E R button. Use the U P and D O W N buttons to change the value for the current step. Press the E N T E R button to confirm the current step. Press the U P and D O W N buttons simultaneously. Press and hold the U P and D O W N buttons simultaneously for two seconds. Home Window The Home window is the default window displayed onscreen. It provides information about current system pressure, HOA switch position, and status of the pump. If there is no user activity on the OID after five minutes, the onscreen window will automatically return to the Home window. Alarms and Events When there are active alarms or events, the Home window will page through information about the pump, alarms, and events at three second intervals. To manually page to the next alarm or event: Press and release the E N T E R key. To freeze the current page: Press and hold the E N T E R key. Release the E N T E R key to unfreeze. Lamp Test A lamp test will toggle the Power Available and Pump Running LEDs on and off. To perform a lamp test, from the Home window: Press and hold the U P and D O W N buttons simultaneously. Release the U P and D O W N buttons to end the test.

User Log In MP15 Jockey Pump Controller 9 Navigating and viewing set point configurations is allowed at all times; however, changing any set point configuration requires the user password. The user password is shown below. This password is also on a label affixed to the cabinet door on the inside. When prompted for the user password, enter the following button sequence: E N T E R UP D O W N D O W N D O W N (1) (2) (3) (3) (3) Logging Out If there is no user activity on the OID after five minutes, the login state is automatically logged out. To manually log out: From the Home window, choose Log Out. Note: The Log Out menu item will not be displayed if the current user login status is not logged in. Configuring System Set Points WARNING To configure the system set points, place the HOA Selector in the Off position. WARNING Adjustments should be performed by qualified personnel only. Configuring a set point value consists of one or more steps, depending on the set point. Use the U P and D O W N buttons to change the value of the current step. Press the E N T E R button to confirm the value of the current step. Once the last step has been complete, the set point value will be saved. For example, the Start Pressure set point has three steps. The first step adjusts the hundredths column, the second step adjusts the tenths column, and the third step adjusts the ones column.

10 MP15 Jockey Pump Controller Another example, the Pressure Unit set point has one step. Use the U P and D O W N button to choose either PSI or BAR. Press the E N T E R button to confirm the step and save the value. Quick Start The quick start feature is used to sequentially configure the primary system set points without having the navigate through the onscreen menu. The following set points are configured: Pressure Unit, Start Pressure, Stop Pressure, Start Delay, and Min Run Time. To perform a quick start: 1. From the home window, choose Quick Start. 2. Configure each set point one at a time: a. Use the UP and D O W N buttons to change the value of the current step. b. Use the E N T E R button to confirm with current step. 3. When the current set point configuration is complete, the next set point will be displayed until all Quick Start set points are configured. Calibrate Pressure Sensor To calibrate the pressure sensor: 1. From the home window, choose Tech Screen Calibrate Pressure Sensor. 2. Follow the onscreen instructions, which are: a. Confirm that you want to begin the calibration process. Press the E N T E R button to continue. b. Lower system pressure to zero and then press the E N T E R button. c. Raise system pressure to the desired nominal system pressure. Press the E N T E R button. d. Use the U P and D O W N buttons to set the value of the expected pressure sensor reading. Press the E N T E R button. e. Calibration is complete.

Set Point Navigation Tree MP15 Jockey Pump Controller 11 Home Window Quick Start System Set Points Start Pressure User Preferences Language Stop Pressure Tech Screen Calibrate Pressure Sensor Pressure Unit Start Delay USB Memory Stick Screen Brightness Min Run Time About Window Short Cycle Time Short Cycle Reoccurrence

12 MP15 Jockey Pump Controller System Set Point Definitions Set Point Start Pressure Stop Pressure Start Delay Minimum Run Time Short Cycle Time Short Cycle Reoccurrence Definition If the system pressure is at or below this setting, and the HOA switch is in the Auto position, then the controller will start the pump. Range: 0 600 PSI 0 41.3 BAR When a low system pressure start occurs, the start condition will stay active until the system pressure rises to the stop pressure. Range: 1 600 PSI 0.1 41.3 BAR This time setting delays the automatic start of the pump when a low system pressure condition occurs. Range: 0 999 Seconds The minimum time that the pump must run before an automatic stop. Range: 0 999 Seconds Activates an alarm if an automatic start occurs within the configured time span since the last automatic stop. This setting is used to determine if the Start Pressure and Stop Pressure set points need adjustments. Set to zero seconds to disable. Range: 0 999 Seconds The number of consecutive short cycles that must occur before the short cycle alarm is activated. When the short cycle time span elapses, this counter is reset. This setting is used to prevent nuisance alarms.

MP15 Jockey Pump Controller 13 Set Point Language Pressure Unit Screen Brightness Calibrate Pressure Sensor Definition Selects the onscreen language. Selects the system pressure unit: PSI or BAR. Adjusts the brightness of the screen backlight. Adjusts the pressure sensor reading.

14 MP15 Jockey Pump Controller Test Procedures Before beginning each test, verify system pressure is above the Start Pressure setting. Turn the HOA switch to the Off position to clear all alarms. Manual Start 1. Turn the HOA switch to the Hand position. 2. The pump should start immediately and the Pump Running LED should turn on. 3. Turn the HOA switch to the Off position. 4. The pump should stop immediately and the Pump Running LED should turn off. Automatic Pressure Start 1. Turn the HOA switch to the Auto position. 2. Lower the system pressure below the configured Start Pressure. 3. The automatic start process will begin. Once the pump begins running, it will continue to run until: a. The HOA switch is set to the Off position, or b. The system pressure rises above the configured Stop Pressure and the Minimum Run Timer expires.

MP15 Jockey Pump Controller 15 Alarm and Event Log Messages The following lists all the possible messages that can be recorded within the data log. Message Pump Running Pump Stopped Pressure Sensor Fault HOA Switch Fault Short Cycle Alarm Off Mode Auto Mode Hand Mode Description The pump has started running manual or automatic. The pump has stopped running manual or automatic. A pressure sensor fault alarm has occurred. An HOA Switch fault alarm has occurred. A short cycle alarm has occurred. The HOA switch has been placed in the Off position. The HOA switch has been placed in the Auto position. The HOA switch has been placed in the Hand position.

16 MP15 Jockey Pump Controller Disposal Metron Eledyne is a member of a compliance scheme under the Waste Electrical and Electronic Equipment regulations which is applicable in all EC countries. At the end of the service life of the equipment the company offers to collect and dispose of this equipment in accordance with regulations in force under the Registration Number WEE/CF0105WV. (Equipment must be suitably packed for collection by courier if outside the UK). Contact: Tel: +44 (0) 1476 516120 Fax: +44 (0) 1476 516121

MP-15 Jockey Pump Controller 17 Replacement Parts For replacement parts, contact your local Metron sales office or the Metron factory at: United States Telephone: +1 (336) 434-2800 FAX: +1 (336) 434-2809 Email: salesmail@metroninc.com Europe Telephone: +44 (0) 1476 516130 Email: jmcivor@metroninc.com Technical Support United States Europe For 24-hour technical support: Telephone: +1 (336) 434-2800 ext. 183 Email: fpctechsupport@metroninc.com Service & Commissioning Telephone: +44 (0) 1476 516129 Email: wrichardson@metroninc.com Emergency Contact: Telephone: +44 (0) 7730 050100 www.metroninc.com www.metroneledyne.co.uk Hubbell Industrial Controls, Inc. Metron Fire Pump Controls Division 4301 Cheyenne Drive, Archdale NC 27263 USA, Tel: (336) 434-2800, Fax: (336) 434-2803 Metron Eledyne a Division of Hubbell Ltd. 18 Autumn Park, Dysart Rd, Grantham Lincolnshire, NG31 7DD, United Kingdom Tel: +44 (0) 1476 516120, Fax: +44 (0) 1476 516121 Printed in USA.