Oilfield Safety OSHA s Stats

Similar documents
Selection, use, care and maintenance it s the law?????

SAFETY POLICY AND PROCEDURE MANUAL All Euramax Subsidiaries. Number K-3.0 Welding Safety Procedures

This is (Enter Company Name Here) Arc Flash Prevention policy. (Enter Name Here) will be responsible for overall direction of the Safety Program.

OKLAHOMA CITY COMMUNITY COLLEGE PERSONAL PROTECTIVE EQUIPMENT PROGRAM. Environmental Health and Safety

Selection, Care and Use of Chemical Protective Clothing. Jason Cole Director of R&D Kappler, Inc.

Flammable Environments Guideline

Leader s Guide ERI Safety Videos

DuPont Arc Guide An Integrated Methodology to Mitigating Electric Arc Hazards

the annulus between the second casing string and the surface casing [must be] open to the atmosphere in the manner described in subsection (2).

Turnout gear is comprised of boots, coat, pants, suspenders, hood, gloves, helmet, and SCBA Facepiece.

product use, care, & inspection Document Released: January, 10, 2012 Approved By: Bryce Merrick

Electrical Safety Program

Electrical Hazard Assessments: OSHA & The NFPA 70E?

PART 4: IMPLEMENTATION & OP

Respiratory Protection Self-Inspection Checklist

Electrical Safety For Managers Updated For E. ElectricalTrainingPro.com

U.S. CONCRETE, INC. SAFETY POLICY and PROCEDURE MANUAL

Definitions found in several locations:

HEAT EXCHANGE AND TRANSFER, INC. 500 Superior Street Carnegie, PA (412) Fax: (412)

Electrical Safety Program

Personal Protective Equipment 29 CFR 1926

OFFICE OF STATE HUMAN RESOURCES

KMU SUBSTATION WORKSHOP

ASSOCIATED DOCUMENTS:

Health Flammability 4 Reactivity 0 PRODUCT NAME MAGIC COMPLETE COUNTERTOP AEROSOL MANUFACTURER'S NAME

Personal Protective Equipment Program

Leader s Guide ERI Safety Videos

Health, Safety, Security and Environment

Respiratory Protection Self Inspection Checklist

=========================================================================== Section 1 PRODUCT AND COMPANY IDENTIFICATION

Respiratory Protection

Newport News Shipbuilding Contractor Environmental, Health and Safety Resource Manual Sewage

ARC:Gear from Unipart Rail

Why do I need to do an Arc-Flash Analysis?

RESPIRATORS & FIT TESTING

ARC:Gear from Unipart Rail

Cal/OSHA T8 CCR 1536 Cal/OSHA T8 CCR 4799 Cal/OSHA T8 CCR 4845 Cal/OSHA T8 CCR 4848

Energy Control Procedures Lockout/Tagout 29 CFR

LION ERS Glove System

USEPA WORKER PROTECTION STANDARD REVISIONS. Department of Pesticide Regulation 2016

Controlling Benzene Exposure

5.0 INSPECTING, FILLING AND LABELING SMALL CYLINDERS

Safety Data Sheet. Section I Product Identification. Section II Hazard Identification

Safety Data Sheet. Section I Product Identification. Section II Hazard Identification

HAZARDOUS WASTE OPERATIONS AND EMERGENCY RESPONSE PLAN Kenyon College

Welding & Cutting Written Program

Progressive Safety Services LLC - All Rights Reserved

MATERIAL SAFETY DATA SHEET

Issue Date 11/21/13 Revision Date 01/04/18 Benzene

This written Compressed Gas Plan is kept at the corporate office and in the written Safety & Health Program.

CITY AND COUNTY OF DENVER CR&CF RISK UNIT Compressed Gas Safety Standard

A. Evaluation of the written program

SPECIALIZED ONLINE TRAINING COURSE LIST

1 Attorney-Client Privileged Communication 1

Health Flammability 2 Reactivity 0 PRODUCT NAME FORMBY S* Build-Up Remover

Process Name Compressed Gas Cylinders Program

Management Plan for Electrical Safety ISD #535

2017 NWHA TECHNICAL SEMINAR. Arc Flash Hazard Awareness MIKE BRENDLE LLC

Hot Work Program. University of Wisconsin-Platteville Reviewed 4/2016

Preview to the 2018 NFPA 70E, the Standard for Electrical Safety in the Workplace

Piped Air SCBA Refilling System Standard

GAF Material Safety Data Sheet MSDS # 2054 MSDS Date: July 2012

Compressed Gas Cylinders - Guideline

General Inspection Guidance for Waste Management Units Requiring Air Emission Controls Under RCRA Air Standard Subpart CC

Midwest Consortium 8HR Modular Exam Inspect/Don/Doff

PERSONAL PROTECTIVE EQUIPMENT

What Every Town Manager Needs to Know About Workplace Safety

Emerging Issues in the Oil and Gas Industry

Laboratory Ventilation. Environmental, Health, and Safety

2012 NFPA 70E: Electrical Safety In The Workplace

Oil & Gas Hazard Alerts: Past, Present and Future. J.D. Danni Safety and Occupational Health Specialist (Oil & Gas) OSHA - Region VIII

Material Safety Data Sheet

SAFETY DATA SHEET FOR FALK GMAX 6000

Effective Date: 24-April-2017 Version: 6 Page: 1 of 8 TITLE: SAF-370, PERSONAL PROTECTIVE EQUIPMENT GUIDELINES. Table of Contents

BASF Flash Fire FRC Assessment Tool

Public Comment No. 176-NFPA [ Global Input ] Statement of Problem and Substantiation for Public Comment. Submitter Information Verification

Arc Flash. Safety 21

Standards of Practice Personal Protective Equipment

Safety Data Sheet in accordance with Regulation (EU) No. 453/2010 and OSHA 29 CFR HCS

Material Safety Data Sheet PAGE NO 01 OF 05. Manufacturers/Distributors Name/Address Emergency/Info Phone No. TREM Card Ref. No.

Safety Data Sheet in accordance with Regulation (EU) No. 453/2010

Northern Kentucky University Issue Date: 11/02/2018 Revised Date: Title: PERSONAL PROTECTIVE EQUIPMENT PROCEDURE OBJECTIVE AND PURPOSE

=========================================================================== Section 1 PRODUCT AND COMPANY IDENTIFICATION

MATERIAL SAFETY DATA SHEET PE Page 1 of 5 Issued 05/10

Confined Space. Program Responsibilities

=========================================================================== Section 1 PRODUCT AND COMPANY IDENTIFICATION

In addition to the responsibility for managing the elements of the respiratory protection program, he/she will be responsible for:

Arc Flash 101. presented by Arc Flash Blaster LLC

Process Safety Management Of Highly Hazardous Chemicals OSHA 29 CFR

Tool Box Talk. Confined Space Entry New Construction Standard (2015)

SAFETY DATA SHEET Rain-X Multi-Surface Water Sealer. 1. Product and Company Identification

STAINLESS STEEL WATER-BASED (16 OZ) #S3331

PENNSYLVANIA DEPARTMENT OF ENVIRONMENTAL PROTECTION

SAFETY DATA SHEET MILES KOOL SOL SS A. Section 1 Identification. Section 2 - Hazards Identification. 1.1 Product Identifiers:

Safety Data Sheet in accordance with Regulation (EU) No. 453/2010

Personal Protective Equipment. Individual Unit Function: Safety Procedure No.: SOP-0147 Page: 1 of 9

Section 37 Brieser Construction SH&E Manual

HAZARD COMMUNICATION Plan Globally Harmonized System

MATERIAL SAFETY DATA SHEET

MSC Guidelines for Independent Fuel Tanks

Transcription:

LTE s Response

Oilfield Safety OSHA s Stats Fatality Rate is 5 times the national average Between 1997 and 2003 16% of the fatalities occurring in the oilfield were related to fire and explosion (OSHA)

OSHA s Response Enforcement Policy for Flame-Resistant Clothing in Oil and Gas Drilling, Well Servicing and Production-Related Operations Issued March 19, 2010 by Richard Fairfax, Director of Enforcement Programs Intended to clarify OSHA s policy for citing the general industry standard for personal protective equipment (29 CFR 1910.132(a)) for failure to provide and use FRC

Hazard Assessment Basic requirement of conducting a Job Hazard Analysis (JHA) followed by a Personal Protective Equipment Assessment (PPEA) to determine the potential need for protective equipment against flash fire hazards under 29 CFR 1910.132(a).

OSHA s Unique Position OSHA concluded that engineering and administrative controls serve to reduce, but not eliminate flash fire hazards. OSHA concluded that employers are required to provide and ensure the proper use of FRC in specific situations.

Drilling Operations Prior to and during drilling in active hydrocarbon zones. In areas where kicks can be expected. Until above situations are controlled by the cementing of casing.

Well Servicing Operations During any open hole operations. Fracturing or perforating a well. Flow testing, blowing down or venting a well. Any operation where the wellhead or wellbore is under pressure.

Production Related Operations Maintenance of production equipment. Equipment start-up. Line breaking or valve changes. Tank gauging. Hydrocarbon and produced water transfer operations. Hot work operations.

OSHA Citations 1910.132 (b) maintenance of PPE Will not cite for dirty FRC unless no plan for replacement Will not cite for lack of certification of maintenance (Cal OSHA will) (c) proper design/selection (label) (d) no hazard assessment * (e) defective & damaged PPE

FRC Selection per NFPA 2113 3 sec. DuPont manikin burn test (ASTM F1930 or F1506) with < 50% body burn or spaced thermal protective rating (TTP) > 25.3 J/cm 2 (6.0 cal/cm 2 ) and contact TTP > 12.6 J/cm 2 (3.0 cal/cm 2 ). Cover upper and lower body and flammable under layers. Avoid meltable closure systems. Offer minimal interference with the work, but not tight-fitting. Minimize non-flame resistant heraldry on exterior (logos, name tags, artwork, etc.)

FRC Use per NFPA 2113 FRC as outermost garment. Collars closed. Sleeves and cuffs down and secured. FRC or non-melting undergarments next to skin. Employee instruction. Other PPE as determined by JHA.

FRC Care Cleaning per NFPA 2113 FRC shall be cleaned according to manufacturer s recommendations. Dry-cleaned by a nonchemical means. Washed using warm water and non-astringent liquid soap. Dried using low heat only. Washed or dry-cleaned at least once prior to initial use. Washed or dry-cleaned with such frequency so as to prevent build-up of contaminants that reduce flame resistance.

FRC Care Storage per NFPA 2113 Stored per manufacturer s recommendations. Not stored in sunlight. Cleaned and dried before storage. Stored in well ventilated area and not with personal items.

FRC Care Maintenance per NFPA 2113 Employees shall inspect FRC after each cleaning and any instances of potential damage. FRC shall only be repaired per manufacturer s recommendations; otherwise FRC shall be replaced if not passing inspection.

LTE POLICY When a potential for a flash fire to occur at a worksite exists, it may be necessary to protect employees by using flameresistant clothing (FRC) to be in compliance with OSHA general industry standard for personal protective equipment (PPE), 29 CFR 1910.132(a).

LTE POLICY It is understood that the use of FRC is not a substitute for engineering and/or administrative methods aimed at reducing exposure potential for people working in potential flash fire areas. A complete health and safety risk assessment should be completed per the requirements outlined in LTE s HASP (Section 100-22) in order to determine what appropriate measures must be taken. It is also understood that the use of FRC may be dictated by client policy and procedures even though it is LTE s belief that a flash fire potential does not exist.

FRC Selection TRIGGER CONDITIONS YES NO FRC NO FRC

FRC Selection Trigger Conditions Intrusive activities drilling, fracing, flow testing, work-over, open pipe or equipment Open Energized Electrical Environmental Sampling Free product or sheen on groundwater VOC reading > 1,000 ppm LEL reading > 10% Methane > 2 mg/l Client Requirements

LTE SOLUTION Arvada Aramark 40 coveralls always available $1.40/pair/week ($56.00/week) 5% laundry charge/week ($2.80/week) Outlying offices Purchase 2 pair per employee Launder at approved cleaner or personally

FRC INSPECTION CHECKLIST Does FRC have any tears, rips or holes? Does FRC exhibit areas more than 2 inches in diameter of permanent staining? Are FRC fasteners missing, bent, broken or non-functional? If the answer to any of the above is yes, FRC must be repaired or replaced before any further use.

Jeffrey M. Citrone Director Health & Safety Compliance, CIH, CSP, REA, PG jcitrone@ltenv.com 720-384-6040