Model DE-1, VDE-1 and DE-2 Air Release Heads

Similar documents
NC MAGNETIC FLOAT SWITCHES FOR LIQUIDS

Meter, PD Series, E3 S6, S7 All Parts List

Meter, PD Series H8-S1, S3, S5, S6, & S7 Parts List

Meter, PD Series, E3 A1, S1 and E4 S1 Prior to 2005 Parts List

Meter, PD Series, E3 S1 and E4 S to Present Parts List

Meter, PD Model T-11 and T-11NF Parts List

Liquid Level Controllers

RCD - Ultra-Rugged Differential Pressure Flowmeter

NC MAGNETIC FLOAT SWITCHES FOR LIQUIDS

BERMAD Waterworks. Level Control Valve with Altitude Pilot. 700 Series. Model X. Features and Benefits. Major Additional Features

Air Eliminators and Combination Air Eliminators Strainers

Smith Meter PD Meter Meter, PD Series, F4 S6, S7. Parts List Bulletin PO01012 Issue/Rev 0.0 (7/13)

PILOT OPERATED RELIEF VALVE SAFETY PRODUCTS THAT PROTECT EQUIPMENT, LIVES & THE ENVIRONMENT

SINGLE VALVE WITH LOW-FLOW BYPASS

WATER MADE EASY MARINE ENERGY MUNICIPAL INDUSTRIAL

61 Series Pilots for Pilot-Operated Pressure Reducing Regulators

Displacer Type Level Controller CT Series Flex Tube

Installation Operation Maintenance

MLS Series Liquid Level Switches. Installation and Operations Manual Section 15

Series 4 Cv= Air-Pilot operated valves. 3-way/2-position, 5-way/2-position, 5-way/3-position

Dual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure. DMV-D/624L Series DMV-DLE/624L Series

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified

G96 Series BASOTROL Dual Operator Valve

shutoff valves 900 Series psig Manual Shutoff Valves

HORIZONTAL BLADDER TANK

Model PRS-07i. Stainless Steel Low Pressure, In-Line Pressure Regulator (Reducing Valve)

VAREC 180 SERIES PRESSURE REGULATORS

VERTICAL BLADDER TANK

1/2 to 2-1/2 NPT; 0 to 230 PSI Advantages / Benefits

Type 310A-32A Pressure Reducing Regulator and Type 310A-32A-32A Working Monitor Regulator

Instruction Manual Pressure Relief Valve and Rupture Disc Chlorine or Sulfur Dioxide, Series 869

Dual Modular Safety Shutoff Valves with Proof of Closure. DMV-D/622 Series DMV-DLE/622 Series

Flow Measurement Equipment Armored Purge Meters

Dual Modular Safety Shutoff Valves. DMV-D/602 Series DMV-DLE/602 Series

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

Level transmitter LT 100

Dual Modular Safety Shutoff Valves. DMV-D/11 Series DMV-DLE/11 Series

Dual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure. DMV-D/624L Series DMV-DLE/624L Series

Avenger Model 33M Installation & Operation Instructions

Dual Modular Safety Shutoff Valves. DMV-D/602 Series DMV-DLE/602 Series

DANFLO Control Valves 400 Series Model 20

Torque Tube TB300 Digital Transmitters

PILOT OPERATED PRESSURE VACUUM RELIEF VALVE MODEL 1660

Design Features. General Description

Dual Modular Safety Shutoff Valves DMV-D 525/11 DMV-DLE 525/11

Type 4660 High-Low Pressure Pilot

Autocalibration Systems For In Situ Oxygen Analyzers

CASH VALVE TYPE KP BACK PRESSURE VALVES

Valve Proving System VDK 200 A S02

Valve Proving System VDK 200 A S06*

For Multi-Parameter Meters see mvx

Dual Modular Safety Shutoff Valves with Proof of Closure and NEMA Type 4x Enclosure DMV-D 704/624 DMV-D 704/634 DMV-DLE 704/624 DMV-DLE 704/634

KDV HIGH ACCURACY GLASS TUBE ROTAMETER

Modulating Valves for Atmospheric, Infrared, and Direct Fired Burners

Dual Modular Safety Shutoff Valves DMV-D 525/11 DMV-DLE 525/11

ASX 176 Axial Pressure regulator

Types ACE95 and ACE95Sr Tank Blanketing Valves

Liquid level instruments BM 24 /BM 51

Dual Modular Safety shutoff Valves with Proof of Closure and NEMA Type 4x Enclosure DMV-D 704/624 DMV-D 704/634 DMV-DLE 704/624 DMV-DLE 704/634

The "BETA AIR RELAY"

Type ACE95jr Tank Blanketing Valve

QBS Electronic Pressure Regulator

ROYTRONIC EXCEL TM Series AD Electronic Metering Pumps

A050-1/2 INCH AIR OPERATED double DIAPHRAGM PUMP

Form No. P Meter, PD Series H8-S3 Flat Plate Cover Parts List

Liquid level switch BM 34

Miniature flowmeters DK 46, DKR 46 DK 47, DK 48, DK 800

The Shand & Jurs Model Vapor Guard Tank Blanketing Valve

Dual Modular Safety Shutoff Valves with NEMA 4x Enclosure DMV-D 704/604 DMV-DLE 704/604

GFM. Typical Aluminum GFM Mass Flow Meter NIST MASS FLOW METERS. Principles of Operation. Design Features

Dean Pump Self-Priming Chemical Process Pumps

MOUNTING SURFACE MOUNTING POSITION MAXIUMUM OPERATING PRESSURE FLUID OPERATING VISCOSITY FLUID CLEANLINESS HYSTERESIS REPEATABILITY THRESHOLD VOLTAGE

VA40 - VA45 Technical Datasheet

Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators

Ball Float Steam Trap UNA 45 MAX, UNA 46 MAX, UNA 46A MAX PN 40/Class 300 DN 40, 50, 65

SM Models Manual Control

Dual Modular Safety Shutoff Valve with NEMA 4x Enclosure. DMV-D/604L Series DMV-DLE/604L Series

Product Overview A DIVISION OF MARSH BELLOFRAM

Gas Pressure Switch for DMV safety shutoff valves

PVK OPEN LOOP PUMPS. Bulletin E

Fisher 4660 High-Low Pressure Pilot

Pressure and/or Temperature Pilot Operated Steam Regulators Series 2000

BULLETIN FOR ACCURATE INDICATION AND CONTROL OF GAS AND LIQUID FLOW IN LOW RANGES.

Model 1800 PFM Series Regulator. Technical Bulletin

Porter Lab & Analytical Products

CVI Valve Line. Exceeds the industry s highest standards for reliability and performance

Measurement of Low GAS & Liquid Flows

T 2523 EN Type 2406 Excess Pressure Valve Self-operated Pressure Regulators ANSI version

GM Series Dual-Block Multi-Function Gas Control Valves

MANUAL. Additive Injector AccuPlus. Installation / Operation Manual. MN05002E Issue/Rev. 0.2 (9/17)

GP1 & GP2. Electropneumatic Regulators FOR PRESSURE CONTROL TO 1,000 PSI

SV - Safety Shutoff Valve with Proof of Closure 1/2" NPT - 2" NPT. SV/614 Series SV-DLE/614 Series

Dual Modular Safety Shutoff Valves with Two-stage operation. DMV-ZRD/602 Series DMV-ZRDLE/602 Series

PRESSURE REGULATOR PRESSURE REDUCING. APPLICATION: Regulation of inlet pressure to gas compressors. Control of supply or distribution system pressure

Types ACE95 and ACE95Sr Tank Blanketing Valves

FIK In-Tank Filters FIK. Max Flow: 170 gpm (643 lpm) Working Pressures to: Rated Static Burst to: Flow Range to:

Self-operated Pressure Regulators Type 2405 Pressure Reducing Valve

SPECIFICATIONS ATTENTION

VG Series VGG and VGD Gas Valves for use with SKP Electro-hydraulic Actuators

Transcription:

SPECIFICATIONS Model DE-1, VDE-1 and DE-2 Air Release Heads Bulletin SS03030 Issue/Rev. 0.7 (8/17) Smith Meter Air Eliminator The Smith Meter Model DE Air Release Heads are dual-electric float switch devices for installation on air eliminator vessels. The dual floats provide a unique and efficient method of air elimination from liquids, as is essential for accurate metering. Air is gathered in the vessel until the lower float switch is actuated. This causes the air vent solenoid valve to open and signals the block valve downstream of the meter to close. The flow is blocked until sufficient air is eliminated from the vessel to actuate the upper float by liquid. This causes the air vent solenoid valve to close and signals the block valve to open, resuming flow. The DE Head is intended to be used in metering systems where bulk air is particularly troublesome (e.g., unloading off tank trucks and barges, or stripping tanks). Features Efficient Air Elimination Performs under a wide range of operating conditions. Versatile Can be used up through 12" systems on most new and existing air eliminator vessels. Hazardous Areas Suitable for use in NEC Class I, Group D, Division 1. Optional Downstream Venting Eliminates need for a spit can and hazardous or undesirable vapors from escaping into the atmosphere. Principles of Operation The Smith Meter Model DE Air Release Head senses the presence of air in the air eliminator or deaerator vessel by means of two float-actuated reed switches. These floats are located at different levels on a stem which protrudes into the vessel. As air accumulates in the vessel, the lower float switch is tripped. This opens the air vent solenoid valve and signals the block valve downstream of the meter to close, thus preventing air from entering the meter. The block valve remains closed until the accumulated air in the vessel has been vented sufficiently to actuate the upper float switch. This closes the air vent solenoid valve and signals the block valve to open so flow can continue. The air venting line may be plumbed back into the flow line to eliminate the need for a spit can. A sight glass is incorporated in this line to assure that the product is not bypassing the meter. Since power must be present at the reed switches in the float stem within the vessel, damage to the stem could cause a short circuit. Danger of an explosion is eliminated by the use of safety barriers, which limit the current below the level where incendiary sparking can occur. Applications Most metering systems, where air elimination is needed, are potential applications for Smith Meter Model DE Air Release Heads. Versions are available for most petroleum, many

petrochemical, chemical and industrial liquid applications. The basic Model DE Air Release Heads can be applied to vessels or systems up to 12". The DE Head is installed in the downstream position on multiple head vessels (8" - 12"). Blind covers are used where additional air release heads were previously installed. A Model DE Air Release Head can be used to replace most existing mechanical air release heads. The standard unit will directly replace Model RB, DB, UB, and B style Air Release Heads on existing air eliminator (or deaerator) vessels. The basic Model DE-1 Head is used for most clean, low viscosity applications. It will interface with a variety of electrically-controlled shut-off valves, including the Model 200-30A Block Valve (Fig. 1). Watts High Capacity DE Head/Block Valve AC DC AC DC DE-1/200-30A DE-2/202 Weight DE-1: 21 lb. (9.5 kg.) VDE-1: 52 lb. (23.6 kg.) DE-2: 24 lb. (10.8 kg.) Air Vent Rate 450 40.0 29.7 40.0 35.3 36.7 26.4 31.2 26.5 The DE-1 is supplied complete with factory-mounted, dual float switch stem, normally-closed solenoid, junction box with relay, current limiting barriers, sight glass, check valve and ball valve. The Model DE-2 is typically used on high viscosity or crude oil applications. It includes a second, independent (parallel), normally-open solenoid controlled air vent line, which closes a direct-acting valve such as a Model 202 Bare Valve (Fig. 2). In addition to the dual float switch stem, the DE-2 is supplied with a normally-closed two-way solenoid and a normallyopen three-way solenoid, junction box, relay, current limiting barriers, sight glass, check valve, ball valves, and valve opening speed orifice. Vent Rate Ft 3 /Min. (scfm) 400 350 300 250 200 150 100 50 VDE-1 High Capacity Specifications 0 0 20 40 60 80 100 120 140 Pressure Differential Across Vent Line (psig) Viscosity DE-1: Up to 45 mpa s 1 (200 SSU) VDE-1: Up to 45 mpa s (200 SSU) DE-2: 45 mpa s through 400 Pa s (200 through 2,000 SSU) 40 Note: DE-2 applied over 45 mpa s to use bare 202 valve only Power Requirements Voltage: : 110 V/50 Hz 120 V/60 Hz. Optional: 220 V/50 Hz 240 V/60 Hz. 12 VDC ±10% 24 VDC ±10% For other voltages, consult factory. Vent Rate Actual Ft 3 /Min. (scfm) 35 30 25 20 15 10 VDE-1 High Capacity 5 0 0 20 40 60 80 100 120 140 Pressure Differential Across Vent Line (psig) 1 1,000 mpa s = 1,000 cp = 1 Pa s. 2 Bulletin SS03030 Issue/Rev. 0.7 (8/17)

Materials of Construction (Wetted Parts) Model Type Float Assembly Mounting Plate DE-1 Tubing and Fittings / Pilot Valves Buna/S.S. Carbon Steel Carbon Steel/Viton Solenoid Valves 9 300/400 S.S./ Viton Sight Glass Bronze Optional 316 S.S. 316 S.S. 300 S.S./PTFE 8 9 300 S.S. VDE-1 316 S.S. Carbon Steel Carbon Steel/Viton DE-2 316 S.S. Carbon Steel Carbon Steel/Viton 300/400 S.S./ Viton 300/400 S.S./ Viton Stainless Steel Bronze Optional 316 S.S. 300 S.S./PTFE 8 9 300 S.S. Modeling Horizontal Tank Modeling Example: DE-1 CF 1 1 HC Type DE-1 Single Solenoid Configuration DE-2 Dual Solenoid Configuration Special Blank HC High Capacity 6 ET Ethanol Service 7 Mounting Plate/Material Used with Model AR Tank or Other: CF Smith Meter/ RB Bolt Circle/ Carbon Steel S Smith Meter/ RB Bolt Circle/Stainless Steel AC 3" Class 150 ASME Flange/Carbon Steel 3 AS 3" Class 150 ASME Flange/316 Stainless Steel 3, 4 Voltage 1 120V/60Hz 2 240V/60Hz 3 12 VDC 5 4 24 VDC 5 5 110V/50Hz 6 220V/50Hz Float Assembly Working Pressure/Density 1, 2 Used with Model AR Tank or Other: 1 Buna Float/316 Stainless Steel Stem 300 psig (2,068 kpa)/0.45 Min. Sp. Gr. 2 316 Stainless Steel Float and Stem, on DE-2 100 psig (689 kpa)/0.70 Min. Sp. Gr. 3 High Pressure 316 Stainless Steel Float and Stem 750 psig (5,171 kpa)/0.75 Min. Sp. Gr. Ordering Information Operating Conditions For Field Installation Liquid Name and sp. gr., Maximum Viscosity, Temperature Range (Min./ Max.), Maximum Operating Pressure Specify tank model and size. Vertical Tank Modeling Example: VDE-1 CC 1 1 Type VDE-1 Single Solenoid Configuration Note: VDE-1 suitable for Ethanol Service standard with HC - High Capacity vent. Mounting Plate/Material CC 6" Class 150 ASME Flange/Carbon Steel Float Assembly Working Pressure/Density 1, 2 1 Spring Assisted PTFE 8 Float/316 Stainless Steel Stem 1,000 psig (6,894 kpa)/0.45 Min. Sp. Gr. 2 316 Stainless Steel Float and Stem 300 psig (2,068 kpa)/0.40 Min. Sp. Gr. Voltage 1 120V/60Hz and 110V/50Hz 2 240V/60Hz and 220V/50Hz 3 12 VDC 5 4 24 VDC 5 1 Maximum working pressures are for temperatures of -20 F to 100 F (-28 C to 38 C). Consult factory for other temperatures. 2 Reduce to 100 psig (690 kpa) on DC circuits because of solenoids. High working pressure requires high pressure solenoids. 3. For non-smith Meter vessels with ASME connection for air release head. 4 Includes 316 S.S. tubing, fitting, pilots, and sight glass. 5 Max. 100 psig (689 kpa). 6 High capacity not available with VAR. 7 No sight glass. 8 Polytetrafluoroethylene (PTFE). 9 Consult factory for alternate materials. Bulletin SS03030 Issue/Rev. 0.7 (8/17) 3

See Wiring Diagram in MN03022 (Installation/Operation). Figure 1 Smith Meter Model DE-1 and VDE-1 with 200-30A Block Valve in open flowing position and no air sensed in the tank. See Wiring Diagram in MN03022 (Installation/Operation). Figure 2 Smith Meter Model DE-2 with 202 Bare Valve in open flowing position and no air sensed in the tank. 4 Bulletin SS03030 Issue/Rev. 0.7 (8/17)

Dimensions Inches (Millimeters) Note: Dimensions Inches to the nearest tenth (millimeters to the nearest whole mm), each independently dimensioned from respective engineering drawings. DE-1 DE-2 Conduit Connection 1/2-14 NPT 7.8" (197) 12.1" (307) 7.5" (191) Customer to Connect (Vent) 3/8-18 NPT Customer to Connect Port #1 to Cover of Shutoff Valve 0.1" (27) NPT 8.9" (226) 11.0" (279) 2.4" (61) Mtg. Plate 6.4" (162) Dia. 8 Mtg. Holes 0.6" (14) Dia. on a 5.4" (138) Dia. B.C. Bulletin SS03030 Issue/Rev. 0.7 (8/17) 5

Dimensions Inches (Millimeters) Note: Dimensions Inches to the nearest tenth (millimeters to the nearest whole mm), each independently dimensioned from respective engineering drawings. VDE-1 Revisions included in SS03030 Issue/Rev. 0.7 (8/17): Total revision. The specifications contained herein are subject to change without notice and any user of said specifications should verify from the manufacturer that the specifications are currently in effect. Otherwise, the manufacturer assumes no responsibility for the use of specifications which may have been changed and are no longer in effect. Contact information is subject to change. For the most current contact information, visit our website at TechnipFMC.com and click on the Contact Us link. TechnipFMC.com FMCTechnologies.com/MeasurementSolutions TechnipFMC 2017 SS03030 Issue/Rev. 0.7 (8/17) TechnipFMC FMC Technologies Measurement Solutions, Inc. 500 North Sam Houston Parkway West, Suite 100 Houston, Texas 77067 USA P:+1 281.260.2190 USA Operation 1602 Wagner Avenue Erie, Pennsylvania 16510 USA P:+1 814.898.5000 Germany Operation Smith Meter GmbH Regentstrasse 1 25474 Ellerbek, Germany P:+49 4101.304.0