Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Type Type Differential Pressure Regulators (opening)

Similar documents
Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

Mounting and Operating Instructions EB 3009 EN. Self-operated Regulators. Type RS Check Valve (backflow protection)

Mounting and Operating Instructions EB 3017 EN. Self-operated Regulators

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

Mounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator

Mounting and Operating Instructions EB EN. Self-operated Pressure Regulators. Type 2335 Excess Pressure Valve with pilot valve

Mounting and Operating Instructions EB 2172 EN. Series 43 Temperature Regulators. Type 43-5 and Type Type Type 43-6

Mounting and Operating Instructions EB 2555 EN. Self-operated Pressure Regulators. Pressure Reducing Valves Type 50 ES Type 50 EM.

Mounting and operating instructions EB 2530 EN. Self-operated Pressure Regulator. Pressure Reducing Valve Type M 44-2

Series 42 Self-operated Regulators Differential Pressure Regulators with Type 2424/Type 2428 Actuator (closing) Type Type 42-28

Pressure Reducing Valve for Steam Type 2333 A

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity

Series 44 Self-operated Pressure Regulators. Type 44-0 B Pressure Reducing Valve. ANSI version

Type 3709 Pneumatic Lock-up Valve. Translation of original instructions. Mounting and Operating Instructions EB 8391 EN

EB EN. Type 44-0 B Steam Pressure Reducing Valve Type 44-1 B Pressure Reducing Valve. Translation of original instructions

Series 44 Self-operated Pressure Regulators. Type 44-1 B Pressure Reducing Valve. Type 44-6 B Excess Pressure Valve. ANSI version

Self-operated Pressure Regulators Type Universal Pressure Reducing Valve

Self-operated Pressure Regulators for special applications

Self-operated Regulators Accessories Differential Pressure and Flow Regulators

Self-operated Pressure Regulators Type 2405 Pressure Reducing Valve

Self-operated Pressure Regulators Type 2405 Pressure Reducing Valve

Mounting and Operating Instructions EB 8546 EN. Type 4708 Supply Pressure Regulators. Translation of original instructions. Type Type

T 2523 EN Type 2406 Excess Pressure Valve Self-operated Pressure Regulators ANSI version

Mounting and Operating Instructions EB 8546 EN. Supply Pressure Regulator Type Fig. 1 Supply pressure regulators

Type Pressure Regulator. for increased air capacity. Fig. 1: Type Pressure Regulator. Mounting and Operating Instructions EB EN

Series 44 Self-operated Pressure Regulators. Type 44-1 B Pressure Reducing Valve. Type 44-6 B Excess Pressure Valve

Declaration of Conformity as per Directive 97/23/EC

Type 4708 Supply Pressure Regulator

Bermad Pressure Reducing. Model: 42T

Declaration of Conformity as per Directive 97/23/EC

Model: 720-UL INSTALLATION OPERATION MAINTENANCE. Bermad Pressure Reducing Valve IOM. Model: FP -720-UL Sizes: 2"-12" BERMAD. Application Engineering

Pressure relief valve

Declaration of Conformity as per Directive 97/23/EC and Manufacturer s Declaration as per Directive 98/37/EC

Declaration of Conformity as per Directive 97/23/EC

Pneumatic proportional controller Types M Types FM Function tested for use of the float in Ex-zone 0

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

Installation & Operation Manual Proven Quality since 1892

Pressure relief valve

Pressure relief valve DHV 712 DN 65-80: 0,5-10 bar, DN : 0,3-4 bar, DN 100: 0,5-6 bar

KBV21i and KBV40i Key Operated Boiler Blowdown Valves Installation and Maintenance Instructions

AVP-F. p setting range (bar) Code No. 003H6200

SRV66 Sanitary Pressure Reducing Valve

Model GP PRESSURE REDUCING VALVE Installation & Operation Manual

3-PIECE BALL VALVE, 3600 PSI/ PN 248, WITH ISO DIRECT MOUNTING PAD 306M SERIES/ PED Category II

Pneumatic switch module 3/2-way valve (On/Off) Types P Types FP Function tested for use of the float in Ex-zone 0

Type 4708 Supply Pressure Regulator

Steam Trap BK BK 212-ASME. Original Installation Instructions English

Differential pressure and flow controller (PN 16) AVPQ - return mounting, adjustable setting

Type 4708 Supply Pressure Regulator

HM and HM34 Inverted Bucket Steam Traps Installation and Maintenance Instructions

Spilt body Flange ball valve. TC-205MFF-PN1640 User Manual English Version. Document No: TC-205MFF-PN1640.Ur-manual. Date: 2007/04/2617. Version: 1.

THE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv)

Pressure Reducing Valve DMV 750 set range: bar

VALFONTA INSTRUCTIONS: OPERATION AND INSTALLATION PRESSURE REDUCING VALVE MODEL PRV44

KBV21i and KBV40i Air Actuated Boiler Blowdown Valves

Spiratec ST14, ST16 and ST17 Sensor Chambers and sensors

Differential pressure controller (PN 25) AVP - return and flow mounting, adjustable setting

Mounting and Operating Instructions EB 9520 EN. Differential Pressure and Flow Meter Media 05

Steam trap BK 37 BK 28 BK 29 BK 37 ASME BK 28 ASME BK 29 ASME

Pressure Relief Valve DHV 718

Manual Actuated Boiler Blowdown Valves

Model: 43T. Bermad Pressure Relief Valve

Reduce pressure zone device suitable for high and medium hazard rated applications BSP screwed connections

Installation, Operating and Maintenance Instructions. V914 Cast Iron Flanged Swing Check Valve V914

Ball Float Steam Trap UNA 43 PN 16/CL 125/JIS 10K UNA 46 PN 40/CL 150/CL 300/JIS 10K/JIS 20K DN 80, 100, 150, 3", 4", 6"

MSC-P and MSC-N Manifolds for Steam Distribution and Condensate Collection

VALFONTA INSTRUCTIONS: OPERATION AND INSTALLATION PRESSURE REDUCING VALVE MODEL M2

Telefon (+45) Telefax (+45)

KTM OM-2 SPLIT BODY FLOATING BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

Mounting and Operating Instructions EB 9519 EN. Differential Pressure and Flow Meter Media 5. Zero adjuster

TA10A and TA10P Steam Tracing Temperature Control Valves Installation and Maintenance Instructions

T R A N S L A T I O N Declaration of Conformity as per Directive 2014/68/EU

Steam Trap BK 15 (DN40, DN 50) Original Installation Instructions English

Pressure relief valve DHV 716 set range: 0,5-10,0 bar

Installation, Operating and Maintenance Manual Overflow Regulator Type 94/ 94 E

Ball Float Steam Trap UNA 45 MAX, UNA 46 MAX, UNA 46A MAX PN 40/Class 300 DN 40, 50, 65

CA10S, CA14 and CA14S Air and Gas Traps

Technical Data Sheet T 2025

APCO ARV CLEAN WATER AIR RELEASE VALVES. Model 50A

VALVCHEQ BACKFLOW PREVENTERS FIGURE RP03

Mounting and Operating Instructions EB 9520 EN. Differential Pressure and Flow Meter Media 05

RHPS Series RD(H)F40 User Manual. Read the complete manual before installing and using the regulator.

1. Preface Important Safety Notes Brief Product Information Product Working Principle Installation Guidelines...

Installation Troubleshooting Maintenance Instructions Installation / Start-up

TP1 and TP2 Temporary Cone Shaped Strainers

Reduce pressure zone device suitable for high and medium hazard rated applications Flanged end connections

FTGS14 Ball Float Steam Trap DN15 (½") to DN25 (1")

SCA Series Inverted Bucket Steam Traps

Installation, Operation and Maintenance Manual for Back Pressure Regulator

BCV31 DN20 - Blowdown Control Valve

Pressure reducing valves Index

Flowmeter. Original operating manual DFM

I T T Pressure Reducing Valve WARNING INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

Instruction Manual Contact Pressure Vacuum Gauge

OPERATING INSTRUCTIONS

VGG... VGF... VGH... Gas Valves. Building Technologies HVAC Products VGG... VGF... VGH...

Installation Operation Maintenance. Bermad Level Control Valve with Modulating Horizontal Float Pilot valve One Way Flow IOM.

Engineering Data Sheet

VALVCHEQ BACKFLOW PREVENTERS FIGURE RP03

Application Notes for Valve Sizing Sizing valves for steam service with the aid of sizing charts

Transcription:

Self-operated Pressure Regulators Type 42-20 Type 42-25 Differential Pressure Regulators (opening) Translation of original instructions Type 42-20 Differential Pressure Regulator Type 42-25 Differential Pressure Regulator Mounting and Operating Instructions EB 3007 EN Edition June 2016

Note on these mounting and operating instructions These mounting and operating instructions assist you in mounting and operating the device safely. The instructions are binding for handling SAMSON devices. ÎÎ For the safe and proper use of these instructions, read them carefully and keep them for later reference. ÎÎ If you have any questions about these instructions, contact SAMSON s After-sales Service Department (aftersalesservice@samson.de). The mounting and operating instructions for the devices are included in the scope of delivery. The latest documentation is available on our website (www.samson.de) > Product documentation. You can enter the document number or type number in the [Find:] field to look for a document. WARNING! Damage to health relating to REACH Regulation. If a SAMSON device contains a substance which is listed as being a substance of very high concern on the candidate list of the REACH Regulation, this circumstance is indicated on the SAMSON delivery note. Information on safe use of the part affected, see u http://www.samson.de/reach-en.html Definition of signal words DANGER! Hazardous situations which, if not avoided, will result in death or serious injury WARNING! Hazardous situations which, if not avoided, could result in death or serious injury NOTICE Property damage message or malfunction Note: Additional information Tip: Recommended action 2 EB 3007 EN

Contents 1 General safety instructions...4 2 Process medium and scope of application...5 3 Transportation and storage...5 4 Design and principle of operation...5 5 Installation...8 5.1 Mounting position...8 5.2 Strainer (filter)...9 5.3 Shut-off valve...9 5.4 Pressure gauge...9 5.5 Control line, compensation chamber and needle valve...9 6 Operation...12 6.1 Start-up...12 6.2 Adjusting the set point...12 6.3 Decommissioning...12 7 Maintenance and troubleshooting...12 7.1 Replacing the operating diaphragm...14 8 After-sales service...15 9 Nameplate...16 10 Appendix...17 10.1 Technical data...17 11 Dimensions...18 EB 3007 EN 3

General safety instructions 1 General safety instructions All safety instructions and warnings given in these mounting and operating instructions, particularly those concerning installation, start-up, and maintenance, must be strictly observed. The device must be mounted, started up, or serviced by fully trained and qualified personnel only; the accepted industry codes and practices are to be observed. Make sure employees or third persons are not exposed to any danger. According to these mounting and operating instructions, trained personnel refers to individuals who are able to judge the work they are assigned to and recognize possible dangers due to their specialized training, their knowledge and experience as well as their knowledge of the applicable standards. The devices comply with the requirements of the European Pressure Equipment Directive 97/23/EC. The declaration of conformity issued for a regulator bearing the CE marking includes information on the applied conformity assessment procedure. This declaration of conformity can be provided on request. To ensure appropriate use, only use the device in applications where the operating pressure and temperatures do not exceed the specifications used for sizing the device at the ordering stage. The manufacturer does not assume any responsibility for damage caused by external forces or any other external factors. Any hazards that could be caused in the regulator by the process medium, operating pressure or by moving parts are to be prevented by taking appropriate precautions. Proper transport, storage, installation, operation, and maintenance are assumed. Note: Non-electric valve versions whose bodies are not lined with an insulating material coating do not have their own potential ignition source according to the risk assessment stipulated in EN 13463-1: 2009, section 5.2, even in the rare incident of an operating fault. Therefore, such valve versions do not fall within the scope of Directive 2014/34/EU. For connection to the equipotential bonding system, observe the requirements specified in section 6.4 of EN 60079-14: 2011 (VDE 0165 Part 1). 4 EB 3007 EN

Process medium and scope of application 2 Process medium and scope of application Differential pressure regulators for extended heating systems and industrial applications. Differential pressure set points Δp from 0.05 to 10 bar Valves DN 15 to 250 Nominal pressure PN 16 to 40 Suitable for liquids and vapors from 5 to 350 C as well as for air and non-flammable gases up to 80 C. The valve opens when the differential pressure rises. 3 Transportation and storage The device must be carefully handled, transported, and stored. Protect the regulator against adverse influences, such as dirt, moisture, or temperature outside the ambient temperature range. Do not remove the protective caps from the valve ports until immediately before installing the valve into the pipeline. When regulators are too heavy to be lifted by hand, fasten the lifting equipment to a suitable place on the valve body. WARNING! Do not attach lifting slings or supports to mounting parts, such as control line etc. The valve can fall or mounting parts may be damaged. Securely fasten slings or rigging equipment to the valve body and secure against slipping. 4 Design and principle of operation See Fig. 1 on page 7. The differential pressure regulators are designed to maintain a constant pressure difference between the upstream pressure line (+) and the downstream pressure line ( ) to an adjustable set point (Type 42-25) or a fixed set point (Type 42-20). The regulators basically consist of the valve with seat (2) and plug (3) and an opening actuator (Type 2425/2420) with an operating diaphragm (13). Valve and actuator are delivered separately and must be assembled on site using a coupling nut (11, width across flats 41, max. tightening torque 120 Nm). EB 3007 EN 5

Design and principle of operation The medium flows through the valve between the plug (3) and the seat (2) in the direction indicated by the arrow. The position of the valve plug determines the differential pressure prevailing across the plant. The Type 2422 Valve is balanced. The forces acting on the valve plug created by the upstream and downstream pressures are balanced by a balancing bellows (5) or balancing diaphragm 1) (5.1). The principle of operation of the regulator balanced by a bellows or diaphragm only differs concerning the pressure balancing. Valves balanced by a diaphragm have a balancing diaphragm (5.1) instead of the balancing bellows (5). The downstream pressure p 2 acts on the bottom of the diaphragm and the upstream pressure p 1 on the top of the diaphragm. As a result, the forces created by the upstream and downstream pressures acting on the plug are balanced out. The differential pressure across the plant is transmitted over the upstream pressure line with the pressure p 1 (+) and the downstream pressure line with the pressure p 2 ( ) to the operating diaphragm (13) where it is converted into a positioning force. This force moves the plug according to the force of the set point springs (16). The set point springs are mounted inside the actuator for a fixed set point (Type 42-20). These springs can be adjusted externally for an adjustable set point (Type 42-25). 1 Valve body 2 Seat 3 Plug 4 Plug stem 5 Balancing bellows 5.1 Balancing diaphragm (DN 65 to 250) 11 Coupling nut 12 Diaphragm stem 13 Operating diaphragm 14 Diaphragm housing 15 Nuts and bolts 16 Set point springs 17 Set point adjuster (nut) 18 Nut 18.1 Clamping nut 19 Diaphragm plate 20 Control line with pressure tapping at the valve 21 Needle valve 1) Type 2422 Valve, balanced by a diaphragm, DN 65 to 250 only Regulator configurations Regulator = Valve + Actuator Type 42-20 Type 2422 balanced Type 2420 fixed set point Type 42-25 Type 2422 balanced Type 2425 adjustable set point 6 EB 3007 EN

Design and principle of operation Type 42-25 Type 2422 Valve, balanced by a diaphragm (DN 65 to 250) 1 P 1 P 2 2 3 4 Type 2422 Valve, balanced by a bellows (DN 15 to 250) P 1 P 2 1 2 3 20 21 19 18.1 18 + _ 5.1 11 12 13 15 14 16 20 21 20 21 19 18.1 18 + _ 4 8 5 20 11 12 13 21 15 14 16 Type 2425 Actuator Type 2425 Actuator Type 2422 Valve, balanced by a diaphragm (DN 65 to 100) + 17 Type 42-20 Type 2420 Actuator Type 2422 Valve, balanced by a bellows (DN 15 to 100) 17 _ 13 16 p 1 Upstream pressure (+) p 2 Downstream pressure ( ) Fig. 1: Functional diagrams of Type 42-25 and Type 42-20 EB 3007 EN 7

Installation 5 Installation The Type 42-20 and Type 42-25 Regulators are designed for installation in the bypass or short circuit of the plant. ÎÎ Choose a place of installation that allows you to freely access the regulator even after the entire plant has been completed. ÎÎ Install a strainer (e.g. SAMSON Type 2 N) upstream of the regulator (see section 5.2). ÎÎ Flush the pipeline thoroughly before installing the regulator to ensure that any sealing parts, weld spatter and other impurities carried along by the process medium do not impair the proper functioning of the valve, above all the tight shutoff. ÎÎ The direction of flow must match the direction indicated by the arrow on the body. NOTICE Incorrectly installed regulator The pressure regulator can be damaged. Make sure the regulator is installed free of stress. Do not attach supports (if required) directly to the valve or actuator. Attach the supports near to the connecting flanges. Observe permissible mounting position. 5.1 Mounting position See Fig. 1 on page 7. See Fig. 2 for permissible mounting positions. Standard mounting position Install valve without actuator in a horizontal pipeline with the connection for the actuator facing downward. Make sure the medium flows through the valve in the direction indicated by the arrow. Balanced by a bellows or diaphragm Standard mounting position All versions Balanced by a bellows Above 80 C Steam applications Balanced by a diaphragm All versions up to max. 80 C Balanced by a bellows All versions DN 15 to 80 plus up to max. 80 C Balanced by a bellows Versions with fixed plug guide Fig. 2: Permissible mounting positions Connect the actuator to the valve bottom section using the coupling nut (11, width across flats 41, max. tightening torque 120 Nm). NOTICE The connection between the plug stem (4) and diaphragm stem (12) is force locking. Do not remove the screw plug. 8 EB 3007 EN

Installation (not between the tapping point and the valve). Plug stem DN 125 to 250 only Valve bottom section Screw SW plug 13 Do not remove! Control line connection Fig. 3: Valve bottom section with plug stem 5.2 Strainer (filter) Install the strainer upstream of the regulator. The direction of flow must correspond to the arrow on the body. The filter element must be installed to hang downwards or sideways for applications with steam. Remember to leave enough space to remove the filter element. Needle valve Compensation chamber 5.3 Shut-off valve Install a hand-operated shut-off valve both upstream of the strainer and at the outlet of the return flow pipe (see Fig. 7). This allows the plant to be shut down for cleaning and maintenance, and when the plant is not used for longer periods of time. 5.4 Pressure gauge Install a pressure gauge both upstream and downstream of the regulator to monitor the pressures prevailing in the plant. Install the pressure gauge on the downstream side behind the downstream pressure tapping point Fig. 4: Regulator for medium temperatures above 150 C or for steam up to 220 C 5.5 Control line, compensation chamber and needle valve Control line A control line preferably as an 8 x 1 mm stainless steel pipe must be provided at the site of installation. Connect the control lines on the valve body to the threaded boreholes (up to DN 100: G ¼; DN 125 and larger: G 3 / 8) in the inlet and outlet. The free inlet and outlet lengths at the valve must be at least three times the nominal size (DN). EB 3007 EN 9

Installation Install any instruments that can cause turbulence in the flow sufficiently far away from the pressure tapping points. (min. three times the nominal size (DN), see Fig. 6). When the control lines are connected to the main pipe, keep the minimum distance of five times the nominal size (DN). Connect control lines at the side of the main pipe. Do not change the pipe diameter of the main pipeline so that it is off center. Control line kit A control line kit for tapping pressure directly at the valve body is available as an accessories part from SAMSON (u T 3095). These control line kits for tapping pressure directly at the valve body already take into account the flow conditions. As a result, no special attention has to be paid to the flow conditions on connecting the regulators. Compensation chamber A compensation chamber is required for liquids above 150 C as well as for steam (valve balanced by a bellows). The mounting position of the compensation chamber is indicated by an adhesive label on the chamber itself as well as by an arrow and the word "top" stamped on the top of the chamber. This mounting position must be adhered to; otherwise the safe functioning of the pressure reducing valve cannot be guaranteed. Note: Only a valve balanced by a bellows can be used for steam control applications. Correct! Connection at the side optimal Incorrect! Connection at the top incorrect position Incorrect! Connection at the bottom incorrect position Fig. 5: Control line connection DN min. 3 x DN (+) min. 3 x DN ( ) Fig. 6: Regulator installation Distances 10 EB 3007 EN

Installation Needle valve If the regulator tends to hunt, we recommend installing a SAMSON screw joint with restriction (needle valve) at the control line connection of the actuator. Note: Needle valves, condensation chambers, excess pressure relief equipment and compression-type screw fittings can be supplied as required. These accessories are listed in u T 3095. Centrifugal pump 1 1 5 3 5 2 1 2 5 3 5 + + 7 p 2 p 1 7 6 Installation in the bypass of a centrifugal pump 7 6 p 1 p 2 1 1 Shut-off valve 2 Strainer 3 Differential pressure regulator 5 Pressure gauge 6 Needle valve (optional) 7 Compensation chamber A compensation chamber is required for liquids above 150 C or for steam. Installation in the short-circuit pipe of a house substation p 1 p 2 Upstream pressure Downstream pressure 7 Fig. 7: Typical installations EB 3007 EN 11

Operation 6 Operation See Fig. 1 on page 7. 6.1 Start-up ÎÎ First start up the regulator after mounting all parts. ÎÎ Make sure the control lines are open and correctly connected. ÎÎ If needle valves are installed in the control lines, open them before start-up. Fill condensation chambers with the process medium before start-up. ÎÎ Open the shut-off valves slowly preferably starting from the downstream side. NOTICE Impermissible excessive pressure. The diaphragm actuator can be damaged. The pressure at the actuator must also not exceed the nominal pressure by 1.5 times on testing the pressure of the plant when the regulator is already installed. The control lines must both transmit the test pressure to the actuator at the same time to ensure that the actuator diaphragm is not damaged. Rinsing the plant After filling the plant, first completely open the consumer and rinse out the pipeline at full flow rate for several minutes. Adjust the differential pressure set point only roughly at first. Check the installed strainer (e.g. by measuring the pressure drop). Clean the strainer, if necessary. 6.2 Adjusting the set point Type 42-25 Adjust the required set point by tensioning the set point springs at the nut (17). If small differential pressure set points are to be adjusted, we recommend using a differential pressure gauge instead of the two pressure gauges to monitor the pressure. Turn the nut (17) clockwise ( ) to increase the pressure set point and counterclockwise ( ) to reduce the pressure set point. Type 42-20 Set point fixed to Δp = 0.2, 0.3, 0.4 or 0.5 bar. 6.3 Decommissioning Preferably close first the shut-off valve on the upstream side of the valve and then on the downstream side of the valve. 7 Maintenance and troubleshooting The regulators do not require any maintenance. Nevertheless, they are subject to natural wear, particularly at the seat, plug, and operating diaphragm. Depending on the operating conditions, check the regulator at regular intervals to avoid possible malfunctions. Details on faults and how to remedy them can be found in Table 1: ÎÎ We recommend removing the valve from the pipeline. 12 EB 3007 EN

Maintenance and troubleshooting WARNING! Excessive pressure may cause parts to move. Before performing any work on the regulator, depressurize the relevant plant section and, depending on the process medium, drain it as well. Shut off or disconnect the control lines. High temperatures When used at high temperatures, allow the plant section to cool down to ambient temperature. Residual medium As valves are not free of cavities, remember that residual process medium might still be contained in the valve. Table 1: Troubleshooting Malfunction Possible reasons Recommended action Differential pressure exceeds the adjusted set point Insufficient upstream pressure pulses on the actuator diaphragm Leak between seat and plug due to wear Strainer blocked Defective operating diaphragm Valve or K VS coefficient too small for control task Clean the control line, needle valve, and screw joint with restriction. Disassemble the regulator and replace damaged parts. Clean strainer. Replace the operating diaphragm (see section 7.1). Check valve sizing. Select valve with larger K VS coefficient, if necessary. Differential pressure drops below the adjusted set point Control loop hunts. Jerky control response Valve or K VS coefficient too large for control task Control line downstream of valve blocked. Leak between seat and plug due to wear Valve or K VS coefficient too large for control task No damping of the pulses as the restriction in the screw fitting of the actuator is too large or is missing. Increased friction, e.g. due to foreign particles between seat and plug. Check valve sizing. Select valve with smaller K VS coefficient, if necessary. Clean the control line, needle valve, and screw joint with restriction. Disassemble the regulator and replace damaged parts. Check valve sizing. Select valve with smaller K VS coefficient, if necessary. Install suitable needle valve in the control line at the actuator. Close this needle valve until the control loop becomes stable. Do not close the needle valve completely! Remove valve from the pipeline and clean parts. If faults cannot be remedied following the recommended action in the table, contact SAMSON (see section 8). EB 3007 EN 13

Operation 7.1 Replacing the operating diaphragm See Fig. 1 on page 7. If just the operating diaphragm is defective, it can be replaced without having to remove the valve from the pipeline. Drain the relevant section of the pipeline. Unscrew the control lines and separate the actuator from the valve. Type 42-20 WARNING! The set point springs may be loaded. Before opening the diaphragm actuator, first unscrew the short bolts and then the long bolts in an even pattern. 1. Undo the bolts (15) at the actuator. 2. Remove the bottom diaphragm case together with the spring assembly. Pull the top part of the diaphragm case off the diaphragm stem (12). 3. Unscrew the nut (18) while holding the bottom diaphragm stem or opposite nut stationary using a suitable tool. 4. Lift off diaphragm plate (19) and pull out diaphragm. 5. Insert a new diaphragm. 6. Proceed in the reverse order to continue assembly of the regulator. Tightening torques (see Table 2). For start-up, proceed as described in section 6. Type 42-25 1. Unscrew the nut (17) and remove the entire spring assembly. 2. Remove bolts (15) and pull both diaphragm cases from the diaphragm stem. 3. Place the diaphragm stem together with nut (18) into a vise and unscrew the nut (18.1) together with the top part of the diaphragm stem. 4. Lift off the diaphragm plate (19) and pull out the diaphragm. 5. Insert a new diaphragm. 6. To reassemble, proceed in reverse order. Tightening torques (see Table 2). For start-up, proceed as described in section 6.1. Table 2: Tightening torques for assembly Actuator 40/ 80 cm² 160/ 320 cm² 640 cm² PN 40/ 160 cm² Item 15 20 Nm 25 Nm 25 Nm 40 Nm Item 18 40 Nm 14 EB 3007 EN

After-sales service 8 After-sales service Contact SAMSON's After-sales Service department for support concerning servicing or repair work or when malfunctions or defects arise. E-mail You can reach the After-sales Service Department at aftersalesservice@samson. Addresses of SAMSON AG and its subsidiaries The addresses of SAMSON AG, its subsidiaries, representatives, and service facilities worldwide can be found on the SAMSON website (u www.samson.de) in all SAMSON product catalogs or on the back of these Mounting and Operating Instructions. To assist diagnosis and in case of an unclear mounting situation, specify the following details (so far as possible). See section 9: Type and nominal size of the valve Model number with index Upstream and downstream pressure Temperature and process medium Min. and max. flow rate Is a strainer installed? Installation drawing showing the exact location of the regulator and all the additionally installed components (shut-off valves, pressure gauge, etc.) EB 3007 EN 15

Nameplate 9 Nameplate Nameplates are attached to the valve and the actuator. Valve nameplate DIN version SAMSON SAMSON 2 ANSI version 2 psi N p bar DN 8 PN 3 3 p 1 No bar T 9 10 11 1 C Kvs Made in Germany 12 No Size psi T F Cv Cl Made in Germany 8 9 10 11 12 4 4 5 5 DIN version 1 Valve type 2 Model number 3 Configuration ID 4 Order number or date 5 K VS coefficient 8 Nominal size 9 Nominal pressure 10 Perm. differential pressure 11 Perm. temperature 12 Body material ANSI version 5 Valve size 8 Perm. differential pressure 9 Perm. temperature ( F) 10 Body material 11 C V coefficient (K VS x 1.17) 12 ANSI Class (pressure rating) Actuator nameplate 1 Model number 5 SAMSON DIN ANSI Type No PN psi Size pmax bar DN 6 7 8 1 2 9 psi bar 3 sq.in cm psi bar A 2 10 4 2002 0062 Made in Germany 11 12 2 Model number index 3 Order number or date 4 Effective area 5 Labeling according to DIN 6 Labeling according to ANSI 7 Max. perm. pressure 8 Nominal pressure 9 Differential pressure 10 Set point range 11 Diaphragm material 12 Year Fig. 8: Nameplates 16 EB 3007 EN

Appendix 10 Appendix 10.1 Technical data Type 42-25 42-20 Valve size DN 15 to 250 DN 15 to 100 Nominal pressure PN 16, 25 or 40 Max. permissible temperature Set point ranges in bar Valve See pressure-temperature diagram in u T 3000 With compensation chamber: steam and liquids up to 350 C Actuator 1) Without compensation chamber: liquids up to 150 C Air and gases up to 80 C 0.05 to 0.25 0.1 to 0.6 0.2 to 1 0.5 to 1.5 1 to 2.5 2 to 5 4.5 to 10 0.2 0.3 0.4 or 0.5 Actuator area A 80 cm² 160 cm² 320 cm² 640 cm² 160 cm² 320 cm² Max. perm. operating pressure for actuator with two diaphragms Leakage class according to IEC 60534 4 1) Higher temperatures on request 40 bar 40 bar 25 bar 25 bar 0.05 % of K VS coefficient Terms for control valve sizing according to IEC 60534, Parts 2-1 and 2-2: F L = 0.95, X T = 0.75 See section 1 for the assignment of actuator and valve. EB 3007 EN 17

Dimensions 11 Dimensions Valve balanced by a bellows Type 42-25 Type 42-20 Balanced by a bellows L H2 L H2 H1 H1 H H ØD Type 42-20 ØD Type 42-25 Fig. 9: Dimension drawing of Type 2422 Valve balanced by a bellows Type 42-25 with actuator with two diaphragms (special version) 55 Add approx. 55 mm to the overall height H. Fig. 10: Dimension drawing of actuator with two diaphragms 18 EB 3007 EN

Dimensions Table 3: Dimensions mm and weights Type 42-20 and Type 42-25 Balanced by a bellows Nominal size DN 15 20 25 32 40 50 65 80 100 125 150 200 250 Length L 130 150 160 180 200 230 290 310 350 400 480 600 730 Height H1 225 300 355 460 590 730 Height Other materials 55 72 100 120 145 175 235 260 H2 Forged steel 53 70 92 98 Type 42-20 Differential Pressure Regulator Set point Height H 390 465 520 0.2 0.3 ØD = 225 mm, ØD = 285 mm, 0.4 or Actuator A = 160 cm² 3) A = 320 cm² 0.5 bar Weight 1) in kg 11.5 12 13 19.5 20 22.5 38 43 57 Type 42-25 Differential Pressure Regulator Set point range 0.05 to 0.25 bar Set point range 0.1 to 0.6 bar Set point range 0.2 to 1 bar Set point range 0.5 to 1.5 bar Set point range 1 to 2.5 bar Set point range 2 to 5 bar Set point range 4.5 to 10 bar Height H 625 700 755 990 1120 1260 Actuator ØD = 285 mm, A = 320 cm² 2) ØD = 285 mm, A = 640 cm² ØD = 390 mm, A = 640 cm² Weight 1) in kg 21 21.5 22.5 29 29.5 32 46 51 65 135 185 425 485 Height H 625 700 755 990 1120 1260 Actuator ØD = 225 mm, A = 160 cm² 3) ØD = 285 mm, A = 320 cm² 2) ØD = 390 mm, A = 640 cm² Weight 1) in kg 16 16.5 17.5 24 24.5 27 46 51 65 135 185 425 485 Height H 635 700 755 990 1120 1260 Actuator ØD = 225 mm, A = 160 cm² 3) ØD = 390 mm, A = 640 cm² Weight 1) in kg 16 16.5 17.5 24 24.5 27 42 47 61 135 185 425 485 Height H 625 700 755 940 1070 1210 Actuator ØD = 225 mm, A = 160 cm² 3) ØD = 285 mm A = 320 cm² Weight 1) in kg 16 16.5 17.5 24 24.5 27 42 47 61 125 175 415 475 Height H 625 700 755 940 1070 1210 Actuator ØD = 225 mm, A = 160 cm² Weight 1) in kg 16 16.5 17.5 24 24.5 27 42 47 61 125 175 415 475 Height H 605 680 735 940 1070 1210 ØD = 225 mm, Actuator ØD = 170 mm, A = 80 cm² A = 160 cm² Weight 1) in kg 16 16.5 17.5 24 24.5 27 42 47 61 102 170 410 470 Height H 685 760 815 Actuator ØD = 170 mm, A = 80 cm² On request Weight 1) in kg 16 16.5 17.5 24 24.5 27 42 47 61 1) The weight applies to the version made of EN-GJL-250/PN 16. Add +10 % for all other materials. 2) Optionally with actuator A = 640 cm² 3) Optionally with actuator A = 320 cm² EB 3007 EN 19

Dimensions Dimensions Valve balanced by a diaphragm Type 42-20/42-25 balanced by a diaphragm H2 H1 H L Type 42-25 with two diaphragms: Add approx. 55 mm to the total height H. Table 4: Dimensions in mm and weights Type 42-20 and Type 42-25 Balanced by a diaphragm Valve size DN 65 DN 80 DN 100 DN 125 DN 150 DN 200 DN 250 Length L 290 310 350 400 480 600 730 Height H1 1) 355 375 Height H2 98 118 145 175 260 Height H 575 595 720 745 960 Weight for PN 16 2) Type 42-25, approx. kg 42 47 55 75 95 250 1) For Type 42-20 2) Valve in PN 25/PN 40: +10 % Fig. 11: Dimension drawing of Type 2422 Valve balanced by a diaphragm 20 EB 3007 EN

Dimensions Note: Conversion from chromate coating to iridescent passivation We at SAMSON are converting the surface treatment of passivated steel parts in our production. As a result, you may receive a device assembled from parts that have been subjected to different surface treatment methods. This means that the surfaces of some parts show different reflections. Parts can have an iridescent yellow or silver color. This has no effect on corrosion protection. For further information go to u www.samson.de/chrome-en.html EB 3007 EN 21

SAMSON AG MESS- UND REGELTECHNIK Weismüllerstraße 3 60314 Frankfurt am Main, Germany Phone: +49 69 4009-0 Fax: +49 69 4009-1507 samson@samson.de www.samson.de EB 3007 EN 2016-06-23 English