Introduction. Medley TM Medication Safety System. Alaris Medical Systems

Similar documents
Alaris Pump module FAQs

RUN POWER HOLD POWER RUN HOLD

Contents. 6. Infusion Mode...10

MedSystemIII. Multi-Channel Infusion Pump with Advanced Dose Rate Calculation DIRECTIONS FOR USE

Troubleshooting Guide Aquarius

AQUADEX FLEXFLOW SYSTEM QUICK REFERENCE GUIDE

Quiz for Module 2: Aquarius Training (Rev. 1) Lesson 1: Introduction to Aquarius

Contacts. Quick Start Guide

Compatible Baxter IV Sets

Nimbus II PainPRO Ambulatory Infusion Pump

Liberty PDx Cycler Handi-Guide

Endo-Flush Order # ZUTR30004 OPERATION MANUAL. Zutron Medical, LLC W 98 th St #40-27 Lenexa, KS Phone Fax

MANITOBA RENAL PROGRAM

Volumat Agilia _Volumat_Presentation_customer.ppt

Alaris CC Syringe Pump

AQUARIUS Continuous Renal Replacement Therapy Competency

Module 2: Aquarius Training

Peristaltic Infusion Pump AP 31P OPERATOR S MANUAL

Nimbus II PainPRO Ambulatory Infusion Pump

Alfred ECMO Circuit Priming and Storage Guide

Liberty Handi-Guide A Patient s Reference to the Most Commonly Asked Questions About the Liberty Cycler

Patients Guide for Self Administering Intravenous Antibiotics General points

CADD-Micro. Model 5900 Operator s Manual. Note: Colors are Black and Cyan (as second color) Deltec. Ambulatory Infusion Pump

Indications for Use: Caution: Note:

Blood Pressure Monitoring: Arterial Line

MJB4 Mask Aligner Operating Procedure. Effective Date: 07/12/2012 Author(s): Jiong Hua Phone:

TANK MANAGER FOR TWO TANKS OPERATING MANUAL. 10/31/11 C-More T6C L color touch panel

Liberty Cycler Handi-Guide

AQUARIUS Continuous Renal Replacement Therapy with Regional Citrate Anticoagulation (RCA) Competency

patient education program 4156 South 52 nd Street, Omaha, NE ChildrensOmaha.org/HomeHealthcare

CircuFlow Quick Setup Guide

SomnoSuite FAQ. Setup. Calibration 4. What are the calibration requirements for the SomnoSuite? Settings

Liberty Handi-Guide. A Patient s Reference to the Most Commonly Asked Questions About the Liberty Cycler

Clinician Guide. Baxter Elastomeric Devices. Promoting patient-centric care

Syringe, Distribution Valve and Infusion Pump Removal/Replacement ATTENTION SYRINGE REPLACEMENT

Handi-Guide A Patient s Reference to the Most Commonly Asked Questions About the Liberty Select Cycler

Infusion. 1 evercare inline

Making Life Easier Easypump II

NEXUS TKO. Specialty Neonatal/Pediatric. Safety Infusion Sets. Blood Reflux Protection 24/7! Anti-Reflux Technology Provides

Alaris GH Guardrails Syringe Pump

Crono PAR. Ambulatory infusion pump NEW MODEL USER GUIDE

CONTENTS DESCRIPTION INTENDED USE. WARNINGS & NOTES. PRECAUTIONS. INSTALLATION & SET-UP (Including battery charging & powering up)

IVIG Educational Presentation

Alaris Syringe Pump (with Plus Software) MK3

The safe use of infusion devices

Digital Display large color coded LED display is easy to read precise measuring shows actual cuff pressure

Using the Akta Prime plus October 22, 2012

C O L O G Y. New. g u O N. l o t a C a. The high security connection

Negative Pressure Wound Therapy

Port - Body in a Box User s Manual

A few seconds after turning on, the screen changes to Set Up Screen Before adjusting the pressure, calibrate the O 2 sensors

3 Way Taps. Year Group: BVSc4 + Document number: CSL_A11

INFUSION SYSTEM (110V) (220V) USER S MANUAL

Instructions for Assembly, Installation, and Operation of the Gas Addition Kit Accessory with the CEM Discover Systems

New. The high security connection

Napa Technology Trouble Shooting. For Premier & Premier PLUS Models

Alaris GP Volumetric Pump. Directions For Use en

Skills & Scenarios 81

Skills & Scenarios 81

HAEMOFILTRATION GUIDELINES

BODYGUARD 2CH TWIN CHANNEL INFUSION PUMP

Tourniquet Systems Pressure Infusion

User Manual Article number: I

TECHNICAL BULLETIN. TriControls. Control Materials for Liquid QC and Calibration Verification

CRONO S-PID 30 Ambulatory infusion pump

Directions for Use Alaris SE Pump Models 7130/7131 and 7230/7231

Instructions for Use

HEALTH SERVICES CODE A.6 CATEGORY: RN - SNP

Multi Channel Solutions

5000TOC Sensor Standard Operating Procedure for TOC Calibration Conductivity Calibration Temperature Calibration Flow Rate Calibration

TJF-Q180V Cleaning and Disinfection Checklist

Lab 4: Transpiration

DIAGNOSTIC CARDIOLOGY

6800 Maintenance Instruction System Flush Procedure

TJF-Q180V Cleaning and Disinfection Checklist

The next generation of Blood and Fluid Warming

istart Owner s Manual

Inside Front cover This page will remain blank.

MoveRoll Conveyor Operating and Maintenance Manual

Peripheral Venous Catheter Placement Simulator

Ambulatory infusion pump USER GUIDE

CDS-2000 CO 2 Sensor Verification, Calibration, and Troubleshooting Bulletin

leaders in enteral delivery

Heart/Lung Perfusion Packs INSTRUCTIONS FOR USE

WATER CONTROL SYSTEM QUICK START

Blue River Technologies Port-A-Poly Mixer w/2.5 GPH LMI Pump And Secondary Water Dilution Line INSTALLATION AND OPERATION

Standard. Abdominal Aortic Aneurysm (AAA) Repair Trainer. Part No: 60610

User Manual for use with the

UsER manual for Watersens ph -REDOX

Vapor Pressure of Liquids

FRDS GEN II SIMULATOR WORKBOOK

Read this first. Zetasizer nano series Self installation and Quick start guide MRK825-02

Fingertip Pulse Oximeter

Bunnell LifePulse HFV Quick Reference Guide # Bunnell Incorporated

OPERATOR S GUIDE 237,0$ 37. Volumetric Infusion Pump. Introduction. Table of contents

6900 Maintenance Instruction System Flush

Abdominal Aortic Aneurysm (AAA) Repair Trainer User Guide

MyoSure Setup Simplified

HEALTHCARE CPR Metrix

Standard Operating Manual

Transcription:

Medley TM Medication Safety System Alaris Medical Systems Introduction The ALARIS Medley Medication Safety System is designed to help you provide the best possible patient care, by avoiding potential adverse drug events associated with IV administration at the point of care. This in turn helps you avoid the potential cost of harm, both in human and financial terms. The Medley Medication Safety System accomplishes this by integrating the infusion, patient monitoring, and clinical best practices at your facility. 1

System Components SpO2 module is not currently being used. Programming Module Pump Module System On Button 2

Priming Close roller clamp Fill the drip chamber to 2/3 full To prime tubing and clear air from SmartSite Needle-Free valve y-sites, slowly open the roller clamp Adult Patients: Invert and tap SmartSite Needle-Free Valve(s) while priming Pediatric/NICU Patients: Once set is primed, attach a sterile luer lock syringe and aspirate air through the SmartSite Needle-Free Valve(s) into the syringe Close the slide clamp and roller clamp Obtain pump from instructor to practice the following tasks Nice 3

Attaching Pump Module Press blue release button on pump module, tip at 45 angle Reattach the pump module, start at a 45 angle Maximum of 4 pump modules Administration Set Priming & Loading Loading administration set 1. Position upper fitment into fitment recess 2. Insert Flo-Stop fitment into recess below mechanism, arrows point into Medley Pump Module 3. Using fingertip, firmly push tubing toward back of Air-in- Line Detector 4

Misloads Illustrations of Misloaded Sets Note: Misloads can lead to rate inaccuracy. System Start-up Press SYSTEM ON NEW PATIENT? Yes clears previous patient data Select YES Next Screen displays previous profile e.g. Critical Care? YES confirms same profile Select NO to preview available profiles Select your patient s profile on the LEFT of the screen Press Confirm PROFILE: A name assigned to a patient care area or patient type. Profiles for WBH Royal Oak: CRITICAL CARE MEDICAL SURGICAL OBSTETRICS ONCOLOGY PEDS A (0-2kg) PEDS B (2.1-15kg) PEDS C (>15kg) TRAINING 5

Programming a Basic Infusion Press CHANNEL SELECT A Select BASIC INFUSION Press RATE, program 10mL/h Press VTBI (volume to be infused), program 100mL Press START Lighthouse is GREEN to show infusion running Press PAUSE on pump module lighthouse is now YELLOW Press RESTART Lighthouse is RED when infusion is disrupted 6

Changing Basic Infusion Rate Press CHANNEL SELECT A Press RATE, program 20 ml/h Press START Note: It is not necessary to pause infusion to change rate Infusion Complete - KVO This is a SIMULATION Press Channel Select A Press Rate, program 50 ml/h Press VTBI, decrease VTBI to 0.1 ml by entering.1 Press Start Note: KVO alert Infusion Complete KVO, Red and Green indicators illuminate lighthouse which indicates that the KVO Rate is infusing. 7

Infusion Complete KVO continued To return to primary infusion rate: Press Channel Select on Channel A Press VTBI, press Restore, note VTBI = 0.1 ml Change VTBI to 100 ml Press Start Channel Labels To program a Channel Label Press Channel Select A Press Options Select Channel Labels Select Maintenance IV Fluid Press Start To clear a Channel Label Press Channel Select A Press Options Select Channel Labels Select Clear Label Press Start 8

Secondary Infusion Press Channel Select A Press Secondary Press Basic Sec Press Rate, program 200 ml/h Press VTBI, program 0.3 ml (to simulate nearing end of secondary infusion) Press Start Remember to lower primary bag and unclamp secondary Note: Plastic hanger that comes with secondary line should be extended the full length when lowering primary bag to ensure full infusion is given. When secondary is complete, the infusion will automatically return to Primary Rate. Policy Guardrail infusion: Used for the administration of most continuous medication infusions and some IVPB medications. If a medication is included in the Guardrails library, the pump must be programmed as a Guardrail infusion. Medications have minimum and maximum dosage limits. If the dose is programmed above/below these limits an alert will appear. 9

Guardrails Drug Library Med/Surg Mandatory use Refer to Policy #465 IV Therapy Electronic Infusion Device Press Channel Select B Press Options Press the Guardrails Drugs Select Dopamine 400mg\250 ml Enter 95kg for patient weight Press Next Program VTBI as 250ml Program Dose as 5 mcg/kg/min Press Start Note: If entering Rate, the dose will automatically be calculated. If entering Dose, the Rate will be automatically calculated. Troubleshooting Air-in-Line lighthouse is RED Message scrolls in channel message display Assess the amount of air in the line by pressing Restart Air passes the eye and resets the eye to detect more air If amount of air is clinically significant, remove air from the line If no air is seen: Ensure the air sensor is clean and free from debris Ensure the set is properly seated in the Air-in-Line detector 10

Troubleshooting continued Occluded Patient Side Lighthouse is RED Partial Occlusion Patient Side or Occluded - Patient Side scrolls in channel message display Clear occulsion on patient side of the infusion below the affected Pump Module and press Restart Flo-stop Open/Close Door Lighthouse is RED Flow stop is in the open position (free-flow position) with the door open Close roller clamp on the set or close the door then press Restart to resume the infusion Volume Infused Press Volume Infused Press Clear All Press Main Screen Note: May clear each channel individually by pressing soft key corresponding to applicable channel 11

Audio Adjust Press Audio Adjust Adjust audio using Softer or Louder (1 through 5) Press Main Screen Display Contrast Press Options Press Display Contrast Adjust contrast using Lighter or Darker Press Main Screen 12

Tamper Resist Panel Lock Prevents unwanted changes by unauthorized persons To lock panel Press and hold Tamper Resist Switch on back (3 seconds) Note: Main screen confirms Panel Locked when key is pressed To unlock panel Tamper Resist Switch Press and hold Tamper Resist Switch (3 seconds) Note: Main screen confirms Panel Unlocked and an advisory tone will confirm tamper Resistant is off Powering Off Individual Channel Off Go to individual pump module Press Channel Off for 1.5 sec (until beep is heard) and release Note: If this is the only pump module in use, this action will Power Off the entire system Multiple Channels - System Off Press Options Press Power Down All Channels Power Down All Channels? Select No 13

Congratulations You have completed Medley Medication Safety System Module Please return the pump to your instructor If you have any questions, please contact the Clinical Nurse Specialist (CNS) on your unit 14