Portable Appliance Testing (PAT) Standard Higher risk environments or activities

Similar documents
Portable Appliance Testing

Policies, Procedures, Guidelines and Protocols

The definition of a competent person given in the Electricity at Work Regulations 1989 (EWR) is as follows:

Electrical Safety (Portable Electric Equipment) Policy

Electrical Equipment Protocol

QPEO2/037N Credit Value: 15 QCF Level: 2 GLH: 68 Maintaining electrical equipment/systems

Code of Practice for the Inspection and Testing of Portable Electrical Equipment (PAT)

SUP 15 Health & Safety Management Pressure Systems. Unified procedures for use within NHS Scotland

Health and Safety Guidance

Health and Safety Policy

Health and Safety Inspection Procedure

PAT Testing Procedures WYMONDHAM RUGBY FOOTBALL CLUB. Wymondham RFC PAT Testing Procedure Version 1 Revision 3 Wednesday, 27 July 2016 Page 1

Electrical Machines & Drives Group Safety Policy 2018/2019

Edinburgh Napier University

Unless this copy has been taken directly from the Trust intranet site (Pandora) there is no assurance that this is the most up to date version

Low Voltage Electricity System Safety Rules & Associated Safety Guidance

Management Plan for Confined Spaces

Isolation Standard - Tags

Contractor Control Procedures. Contractor Control Procedures. Working Together. November Borders College 24/11/2014.

The Yorkshire Waterways Museum, Dutch River Side, Goole, POND AND NATURE TRAIL RISK ASSESSMENT SHE/RA/00

Maintaining electrical equipment/systems

Pressure Systems Safety Regulation

Gas Safety Code of Practice

Reviewed: DD Month Management of Closed Radioactive Sources

MAKING ELECTRICAL A GUIDE ON HOW TO INSPECT AND TEST PORTABLE APPLIANCES SAFELY AND EFFECTIVELY

Electrical, electronic and control engineering at the operational level

ESTATES OFFICE OPERATIONS WORKS INSTRUCTIONS WI 6. Fume Cupboards, Ventilated Cabinets, Local Exhaust Ventilation

Loughborough University (incl. London Campus) Health and Safety Policy. Policy for the Electricity at Work Policy and Code of Practice

The University of Georgia Automated External Defibrillator (AED) Program Guidelines

Health & Safety: Electrical safety

Hazardous Waste Training Plan. Supersedes: 02/15/16 (Rev.02) Preparer: Owner: Approver: EHS Team Member EHS Team Member EHS Manager

Minimum standard of competence for electro-technical officers (STCW Reg III/6) Electrical, electronic and control engineering at the operational level

MEDICAL GAS CYLINDERS AND MEDICAL PIPELINE SYSTEMS (MGPS) POLICY

THE INSPECTION OF PORTABLE ELECTRICAL EQUIPMENT

LEGIONELLA POLICY & MANAGEMENT PLAN UNIVERSITY OF ESSEX HUMAN RESOURCES / ESTATE MANAGEMENT SERVICE

General Isolation Procedures

Confined Spaces. This procedure applies to all workers of the Diocese of Maitland Newcastle (DoMN).

IMMANUEL CHURCH, CHICHESTER HEALTH AND SAFETY POLICY

SOP. Working in Confined Spaces

Lifting Equipment Procedure. Committees / Group Date Consultation: Health and Safety Sub Committee Nov 2016

BODY OF KNOWLEDGE API TES TANK ENTRY SUPERVISOR

SEMEEE3-34 Carrying out functional tests on electrical equipment

In-Service Inspection and Testing of Electrical Equipment Certificate

3. PURPOSE: To establish the minimum safety content of swimming pool Operations Manuals.

RISK ASSESSMENT A UNIVERSITY GUIDE TO PRACTICAL RISK ASSESSMENT UNDER THE MANAGEMENT OF HEALTH AND SAFETY AT WORK REGULATIONS 1992

Guidance on Enclosed Space Entry and Rescue

Geotechnics, Face and Stockpile Operations

SEMEM3-73 Maintaining medical gas pipeline systems and equipment

Hampstead Hill School Health and Safety Policy: Confined Spaces

BODY OF KNOWLEDGE TANK ENTRY SUPERVISOR CERTIFICATION PROGRAM Revision 2, October 2013

SOAS LONE WORKING GUIDANCE

HSE guidelines. SMay 2015 ELECTRICAL SAFETY HSE LIFE THE NATIONAL OIL&GAS INDUSTRY STANDARD FOR PROFESSIONALS

SUBJECT: LIFTING OPERATIONS AND LIFTING EQUIPMENT (LOLER)

(2) but does not include a shaft, trench or tunnel that is a mine or is part of the workings of a mine.

The invisible killer - electrical safety in the food and drink industry

SEMEMI SQA Unit Code H2AP 04 Carrying out fault location on electrical equipment and circuits

Lifting Operations and Lifting Equipment Regulations (LOLER) Policy. Version No. 2. Review: May 2019

Kettleshulme Parish Council Risk Assessment 2015 Kettleshulme Memorial Hall

Control of Allergies to Laboratory Animals

Name Phone Logo

Appendix A: Induction check list

Accreditation for In-Service Inspection of Pressure Systems/Equipment

Edinburgh Napier University Safe Working Procedure Gas Safety, Gas Systems and Equipment

SOP - LIFT RESCUE PROCEDURES

List all key terms and acronyms used in the procedure, and their definitions.

Gas Network Craftsperson

Instructions for Completing the UW-Madison Laboratory Chemical Hygiene Plan Template

APPROVED CODE OF PRACTICE FOR THE SAFE CONDUCT OF TRACK AND FIELD TRAINING

Working Alone Guidelines

PROCEDURES FOR STANDBY

Fire Safety Hot Work Permit Policy/ Procedures

Safety Services Guidance. Guidance on: The Provision and Use of Work Equipment Regulations 1998 (PUWER)

Tradinco Academy Courses Program

GSA POLICY ON LOCAL EXHAUST AND OTHER VENTILATION (FUME CUPBOARDS)

CODE OF PRACTICE 42 IMPLEMENTATION OF EIGA CARBON DIOXIDE STANDARDS REVISION 2: 2018

OPERATING AND MAINTENANCE MANUAL GOLD LINE EXTRACTION CLEANERS M14-M26

VENUE RISK ASSESSMENT CHECKLIST

Health & Safety Policy

Accreditation for In-Service Inspection of Transportable Pressure Receptacles (TPRs)

Instructions for the Use of the Excel Spreadsheet. There are Three tabs at the bottom of this worksheet. Instructions tab is the one you are reading

General maintenance engineering applications

Facilities and Estates. Natural Gas: Standard Operating Procedure. Document Control Summary. Contents

Work Equipment: LOCAL EXHAUST VENTILATION

Installing, Repairing or Modifying Construction Resources by Heating, Welding, Brazing, Soldering and Thermal Cutting in the Workplace L/505/0144

HEALTH AND SAFETY RISK ASSESSMENT POLICY Harmer Street Gravesend Kent DA12 2AX

Health & Safety Policy & Plan. Rightway Roofing.

PLANT HAZARD REPORT. Plant Description: Element Aspect Plant Hazards and Controls Advice. Circular Saw

Hazard Management Making your workplace safer

EXHIBITION Guide. Roles and Responsibilities OS11. A handbook for exhibitors and contractors

Lone and Hazardous Working Policy June 2010

A best practice guide produced in collaboration between

General maintenance engineering applications

Construction & Building Industry Safety Guideline. Electrical Isolations

SAFETY AND HEALTH STANDARD CONFINED SPACE ENTRY REQUIREMENTS Effective Date: 06/10/10 Standard: 16.2 Document Number: KUCSH0038 Rev: 07

Gas Tester Competent Person Course Outline

Explosion Protection Technology Pty Ltd

Proficiency Module Syllabus. P601 - Thorough Examination and Testing of Local Exhaust Ventilation Systems

ELECTRICAL (COMPREHENSIVE) SAFETY PROGRAM REGULATORY STANDARD: OSHA - 29 CFR CFR , ,

GUIDANCE NOTES ON LOLER REGULATIONS FOR RIVERIA MK1.MK2 & MK3 AND BELLAVITA BATH LIFT. Lifting Operations and Lifting Equipment Regulations 1998

How to plan an event. Step 1: First things first. Step 2: How to make it all happen?

Transcription:

Portable Appliance Testing (PAT) Standard Higher risk environments or activities This section of the PAT Standard provides information in addition to that given in low risk environments and so should be read in conjunction with this and also PAT Explained. Local rules requiring a higher standard of electrical safety Local rules may be in place for some higher risk environments such as Biological Sciences or Computer Science and Electronic Engineering, Information Systems Services computer workshops or higher risk activities such as laboratory work, use of electrical equipment in building or production workshops, work with patients or professional catering wet rooms and kitchens. Higher risk environments or activities are those where the risk of injury from electricity or fire is strongly linked to where and how it will be used, such as: where electrical equipment, including extension leads, are moved often and more likely to become damaged; in wet surroundings unsuitable equipment can easily become live and can make its surroundings live; outdoors equipment may become wet and be at greater risk of damage; in cramped spaces where it could be difficult to avoid a shock if an electrical fault developed; in a potentially flammable or explosive atmosphere where electricity could be the source of ignition. Higher risk environments will require a higher standard of safety precautions against contact with live parts, faults which could cause fire, or electricity as a possible source of ignition. The department or area s risk assessment should detail the electrical risks specific to that area and/or activity and the associated control measures. The Head of Department / Section / Business Unit, Departmental Health and Safety Officer or person responsible for the area should be able to advise what is required, or see Points of Contact Electrical Safety. Does brand new electrical equipment require PAT? Local rules may be in place which require either a formal visual inspection or combined PAT to be carried out before electrical equipment is connected to the mains supply for the first time. Check with the person responsible for arranging PAT in your area. How often should PAT be carried out? Catering and hospitality The Health and Safety Executive have specific guidance on maintenance priorities, including PAT, in catering establishments. See www.hse.gov.uk/pubns/cais12.htm. PAT: Higher risk environments or activities Issue 2: June 2013 Page 1 of 6

Theatres and entertainment venues Theatres and entertainment venues, have their own industry guidance on electrical safety and PAT, available from the Association of British Theatre Technicians (http://www.abtt.org.uk/resource/codes-forms-and-updates) and Health and Safety Executive (www.hse.gov.uk/pubns/indg247.pdf). This guidance should be referred to if you are responsible for a theatre or entertainment venue in order to determine the frequency of PAT and records to be kept. In addition the Health and Safety Executive also publish Electrical Safety at places of entertainment (www.hse.gov.uk/pubns/gs50.pdf). Other common types of equipment in higher risk environments University guidance is summarised in the tables below. See the Glossary of Terms for an explanation of Class I and Class II electrical equipment. The person responsible for a particular area or electrical equipment may wish to carry out PAT more often, however the frequencies indicated below should be the minimum. See Points of Contact Electrical Safety should further clarification be needed. HIGHER RISK ENVIRONMENTS WHERE DIFFERENT FREQUENCIES OF PAT MAY BE REQUIRED Type of PAT and guide frequency Area / Work Environment Examples Simple Visual Check 1 Formal Visual Inspection Computer laboratories Yes Combined PAT (te: may be required earlier in some circumstances. See PAT explained ) Information Systems Services Audio Visual Media Services Laboratory Workshop, eg EMS workshops E15 workshops Estate Management Section (Building Services) School of Health and Human Sciences Rarely moved network equipment (eg mains extension cables) in service risers, plant rooms, ducts Teaching rooms Lecture rooms Any audio visual equipment which is hired, leased or loaned Laboratory testing, analysis, research equipment Any equipment issued to students Portable drill Soldering iron Portable pump Mains operated saw Mains operated sander Vacuum cleaners Medical apparatus used for patient care / monitoring, or for analysis or research Yes Yes 5 years or with scheduled maintenance before use before use 6 monthly Refer to the relevant Hospital Technical Memorandum 1 When installed, moved or may be included as part of an annual health and safety inspection PAT: Higher risk environments or activities Issue 2: June 2013 Page 2 of 6

HIGHER RISK ENVIRONMENTS WHERE DIFFERENT FREQUENCIES OF PAT MAY BE REQUIRED Area / Work Environment Accommodation residences Wivenhoe House Hotel Catering outlets Examples University owned equipment used by students or residents, eg iron, kettle Free standing fridges / freezers in student residences Cleaning equipment: Scrubbers Vacuum cleaners Any equipment issued to residences or students, eg heaters Hotel bedrooms Communal areas Teaching rooms Function rooms Commercial catering equipment Any equipment issued for a function Commercial catering equipment Simple Visual Check 2 by University staff Type of PAT and guide frequency Formal Combined PAT Visual (te: may be required earlier Inspection in some circumstances. See PAT explained ) 6 months before letting Yes See Equipment Type 6 months 6 months Who carries out PAT? Those responsible for higher risk environments or activities may choose to appoint University staff to undertake PAT duties for formal visual inspection and/or combined PAT, known as PAT testers. This may offer the advantage of being able to carry out PAT whenever it is required, such as when electrical equipment is used in a work area for the first time, and may be more cost effective in some areas. Examples include: Department of Biological Sciences Department of Computer Science and Electronic Engineering Information System Services East 15 Students Union Depending on the nature of the task and level of risk, a risk assessment and safe system of work or local rules may need to be in place. 2 When installed, moved or may be included as part of an annual health and safety inspection PAT: Higher risk environments or activities Issue 2: June 2013 Page 3 of 6

Minimum requirements for training and experience of PAT testers Industry qualifications for in-service inspection and testing of electrical equipment, alone, do not necessarily demonstrate competency. PAT testers must have sufficient experience and technical knowledge to carry out a formal visual inspection and/or combined PAT without putting themselves or others at risk. The IET Code of Practice for In-service Inspection and Testing of Electrical Equipment (Fourth Edition) advises the following: Training Training should cover the different types of equipment to determine test procedures and frequency of inspection testing, familiarity with test instruments including their limitations and restrictions, the PAT tester s responsibility for sign off of PAT, basic electrical and electronic principles (such as how single phase electricity works and the hazards), how electrical / mechanical / thermal damage can occur, safe isolation procedures and safe systems of work. Examples might include the Level 3 Certificate for the Inspection and Testing of Electrical Equipment (City & Guilds, reference 2377-12), or the Association of British Theatre Technicians CPD course on PAT (part of the Silver Award on Electrical Safety), or an equivalent alternative qualification. Experience The PAT tester should have sufficient experience and technical knowledge to perform the inspection and testing without putting the PAT tester or others at risk. This includes an adequate understanding of the equipment to be worked on and practical experience of that system, the hazards and precautions to be taken and whether it is safe to continue. Newly qualified PAT testers will require adequate supervision by a competent person whilst this experience is gained. City and Guilds offer a Level 3 Certificate of Management of Electrical Equipment Maintenance for supervisors of multiple PAT testers. Persons who repair faulty electrical equipment Any person repairing faulty equipment should be able to safely and effectively repair the faulty item of equipment without putting themselves or others at risk. Suitable training and experience will be needed. Training records for PAT testers must be held by the person responsible for the PAT tester/s in their area. Records, including certificates, could be requested for the purposes of inspection, audit, annual health and safety inspection or as part of an investigation and so should be readily available if requested. Minimum requirements for PAT testers to be authorised to carry out PAT The Head of Department / Section / Business Unit is responsible for authorising those individuals who they deem competent to carry out formal visual inspections and/or combined PAT. The names and contact details for authorised PAT testers should be available locally and included in the Health and Safety Management Statement or similar document. The Head of Department / Section / Business Unit must also notify the Deputy Director of Estate Management (Maintenance) of those personnel, who will keep a central record of authorised PAT testers. Periodical reviews of authorised PAT testers may be carried out. PAT: Higher risk environments or activities Issue 2: June 2013 Page 4 of 6

How should PAT be arranged? The task of noting the next due date for respective levels of PAT may be delegated to the Departmental Health and Safety Officer (DHSO), similar appointed person or the authorised PAT tester for your area. They will then advise appropriate arrangements for PAT, whether through the Estate Management Section Helpdesk (Colchester campus), the facilities management provider (Southend and Loughton campuses), or the authorised PAT tester for your area. See Points of Contact Electrical Safety for email addresses and telephone numbers or your DHSO. Is there a standard portable appliance testing device to be used?. The specification and features of portable appliance testing devices varies. The choice of which tester is appropriate will depend on how the electrical equipment is used and the depth of information needed. The Institution of Engineering and Technology recommend that, in low risk environments, a properly trained competent member of staff can perform these tests using a suitable off the shelf PAT tester on equipment that is disconnected from the electrical supply. In higher risk areas a more highly trained specialist may be needed to disconnect the equipment from the electrical supply, perform complex tests and to interpret the results. 3 Such devices may need calibration and maintenance. Any person using a testing device must be competent in the use of that device and the interpretation of any test results. Should records of completed PAT be kept by PAT testers? Yes. Records of maintenance, including PAT results, should be kept for at least three years after the date when portable equipment is removed from the area or responsibly disposed of. PAT testers may wish to record a summary of the outcomes of formal visual inspections and/or combined PAT on the templates provided. These are available in Word and Excel formats and can be customised to suit users needs. See The Institution of Engineering Technology s Code of Practice for In-service Testing and Inspection of Electrical Equipment for guidance and templates to record detailed inspection and/or test results. Some test equipment offers the facility to download summary and detailed test results directly into a report. Will there be a charge for PAT? University owned electrical equipment of a specialist nature If a department, section or business unit has specialised equipment specific to that area s activities which requires testing by the Estate Management Section, this will be chargeable. A quotation can be obtained by sending an email to the Estate Management Section Helpdesk (see Points of Contact Electrical Safety). However, such areas may have their own authorised PAT testers and so costs can be managed internally. 3 The Institution of Engineering and Technology, Portable Appliance Testing, Health & Safety Briefing. 34c (May 2012) PAT: Higher risk environments or activities Issue 2: June 2013 Page 5 of 6

University of Essex Campus Services / Wivenhoe House Hotel / Student Union A charge will be made by the Estate Management Section for all levels of PAT required by these Business Units, or by the facilities management provider for the Student Union in Southend or Loughton. PAT: Higher risk environments or activities Issue 2: June 2013 Page 6 of 6