Reliability and Validity of the Shaw Gait Assessment Tool for Temporospatial Gait Assessment in People With Hemiparesis

Similar documents
MEASUREMENTS OF TEMPORAL and spatial gait parameters

Walking speemtmmkubjects and amputees: aspects of validity of gait analysis

Gait Analyser. Description of Walking Performance

BIODEX. New Jersey clinic enhances patient rehab using music-assisted gait training CASESTUDY. Body In Balance Physical Therapy and Fitness Center

Factors of Influence on the Walking Ability of Children with Spastic Cerebral Palsy

RUNNING. Normal Running 10/10/2016. Reliability and Concurrent Validity of a 2D Observational Gait Analysis Tool

Measurement of Step Widths and Step Lengths: A Comparison of Measurements Made Directly From a Grid With Those Made From ;video Recording

Ambulatory monitoring of gait quality with wearable inertial sensors

G-EOL. Discover the simplicity of gait therapy intended for daily use

Test-Retest Reliability of the StepWatch Activity Monitor Outputs in Individuals

Gait temporospatial parameters: assessment tools for postsurgical. types of lumbar disc herniation

To find out effectiveness of backward walking training in improving dynamic balance and gait in stroke patients

JEPonline Journal of Exercise Physiologyonline

Smita Rao PT PhD. Judith F. Baumhauer MD Josh Tome MS Deborah A. Nawoczenski PT PhD

Salisbury District Hospital

CHAPTER 3. Hemiplegic gait after stroke: Is measurement of maximum speed required? Boudewijn Kollen, Gert Kwakkel and Eline Lindeman

The Promise of Achieving Higher Standards in Children s Health. The Gait and Motion Analysis Laboratory Referral Guide

GAIT MEASUREMENTS AND MOTOR RECOVERY AFTER STROKE. Plamen S. Mateev, Ina M. Tarkka, Ekaterina B. Titianova

IMPORTANT: All features subject to change without notice.

Comparison of Reliability of Isometric Leg Muscle Strength Measurements Made Using a Hand-Held Dynamometer with and without a Restraining Belt

Analysis of Gait Characteristics Changes in Normal Walking and Fast Walking Of the Elderly People

There have been many studies on gait analysis. Gait analysis can be divided into the following three. Original Article

Analysis of Variance. Copyright 2014 Pearson Education, Inc.

The Impact of Walker Style on Gait Characteristics in Non-assistive Device Dependent older Adults

Using Hexoskin Wearable Technology to Obtain Body Metrics During Trail Hiking

or

Flip-flop footwear with a moulded foot-bed for the treatment of foot pain: a randomised controlled trial

THE INFLUENCE OF SLOW RECOVERY INSOLE ON PLANTAR PRESSURE AND CONTACT AREA DURING WALKING

Ultrasonic motion analysis system - measurement of temporal and spatial gait parameters Huitema, RB; Hof, At L.; Postema, K

Quantitative assessment of circumduction, hip hiking, and forefoot contact gait using Lissajous figures

Corrected FIM effectiveness as an index independent of FIM score on admission

G- EOSYSTEM training more, more effectively. visit rehatechnology.com

EFFECT OF SHOE RAISE ALONG WITH MOTOR RELEARNING PROGRAMME (MRP) ON AMBULATION IN CHRONIC STROKE

An investigation of kinematic and kinetic variables for the description of prosthetic gait using the ENOCH system

Expanding the Scoring System for the Dynamic Gait Index. Anne Shumway-Cook, Catherine S. Taylor, Patricia Noritake Matsuda, Michael T.

Self-fulfilling prophecy? Current affairs. Reality check 11/29/2011

Gait Analysis An Introduction Michael W Whittle

Plastic Ankle-Foot Orthosis

TIMING AND COORDINATION OF GAIT: IMPACT OF AGING, GAIT SPEED AND RHYTHMIC AUDITORY CUEING. Maha M. Almarwani

Analysis of Foot Pressure Variation with Change in Stride Length

Examination and Treatment of Postural and Locomotor Control

Spinal Cord Injury (SCI) and Gait Training

The Optimal Downhill Slope for Acute Overspeed Running

WHAT CAN WE LEARN FROM COMPETITION ANALYSIS AT THE 1999 PAN PACIFIC SWIMMING CHAMPIONSHIPS?

Analysis of the Interrelationship Among Traffic Flow Conditions, Driving Behavior, and Degree of Driver s Satisfaction on Rural Motorways

The Singapore Copyright Act applies to the use of this document.

Relationship between Ground Reaction Force and Stability Level of the Lower Extremity in Runners Background: Objective: Design and Setting:

The effect of deliberate practice on the technique of national calibre swimmers

INTERACTION OF STEP LENGTH AND STEP RATE DURING SPRINT RUNNING

Academic Grant CPR process monitors provided by Zoll. conflict of interest to declare

The overarching aim of the work presented in this thesis was to assess and

Insurance. The practical application. of credibility models in the rating of Health

Normative data of postural sway by using sway meter among young healthy adults

DEVELOPMENT AND VALIDATION OF A GAIT CLASSIFICATION SYSTEM FOR OLDER ADULTS BY MOVEMENT CONTROL AND BIOMECHANICAL FACTORS. Wen-Ni Wennie Huang

KINEMATIC QUANTIFICATION OF GAIT SYMMETRY BASED ON BILATERAL CYCLOGRAMS

POWER Quantifying Correction Curve Uncertainty Through Empirical Methods

Knee Kinematic Improvement after Total Knee Replacement Using a Simplified Quantitative Gait Analysis Method

NEUROLOGICAL INSIGHTS FOR TEACHING GOLF TO TODAY S FITNESS CHALLENGED

Spasticity in gait. Wessex ACPIN Spasticity Presentation Alison Clarke

Gait & Posture 31 (2010) Contents lists available at ScienceDirect. Gait & Posture. journal homepage:

Original Research. Validity of Different Activity Monitors to Count Steps in an Inpatient Rehabilitation Setting

Introduction -

or

Gait Analysis at Your Fingertips:

HHS Public Access Author manuscript Int J Cardiol. Author manuscript; available in PMC 2016 April 15.

MEMORANDUM. Investigation of Variability of Bourdon Gauge Sets in the Chemical Engineering Transport Laboratory

Mobility Lab provides sensitive, valid and reliable outcome measures.

The Effect of a Seven Week Exercise Program on Golf Swing Performance and Musculoskeletal Screening Scores

Inter and intra-limb processes of gait control.

Denise L Seman City of Youngstown

Can listening to an out of step beat help walking after stroke?

The Impact of TennCare: A Survey of Recipients 2009

Can Asymmetric Running Patterns Be Predicted By Assessment of Asymmetric Standing Posture? A Case Study in Elite College Runners

Center of Mass Acceleration as a Surrogate for Force Production After Spinal Cord Injury Effects of Inclined Treadmill Walking

Analyses of the Scoring of Writing Essays For the Pennsylvania System of Student Assessment

PURPOSE. METHODS Design

Balance Item Score (0-4)

RELATIONSHIP OF SELECTED KINEMATIC VARIABLES WITH THE PERFORMANCE OF DOUBLE HANDEDBACKHAND IN TENNIS. Rajesh Kumar, M.P.Ed,

ABSTRACT AUTHOR. Kinematic Analysis of the Women's 400m Hurdles. by Kenny Guex. he women's 400m hurdles is a relatively

CHAPTER III METHODOLOGY. 1. To analyze the gait pattern in post stroke hemiparetic patients

SIMULTANEOUS RECORDINGS OF VELOCITY AND VIDEO DURING SWIMMING

Influence of speed on gait parameters and on symmetry in transtibial

Improving walking assessment in subjects with an incomplete spinal cord injury: responsiveness

NIH Public Access Author Manuscript Gait Posture. Author manuscript; available in PMC 2009 May 1.

Effects of Real-time Auditory Stimulation Feedback on Balance and Gait after Stroke: a Randomized Controlled Trial

Clinical Study Synopsis

Key words: biomechanics, injury, technique, measurement, strength, evaluation

Chayanin Angthong, MD, PhD Foot & Ankle Surgery Department of Orthopaedics, Faculty of Medicine Thammasat University, Pathum Thani, Thailand

The Influence of Load Carrying Modes on Gait variables of Healthy Indian Women

Development of Gait at Slow, Free, and Fast Speeds in 3- and 5-Year-Old Children

The three steps for biomechanical assessment are the following: > Periodically verify the results and the efficacy of treatment

Product Recognition Program

Risk Factors Involved in Cheerleading Injuries

GAIT DEFICIENCIES IN INDIVIDUALS WITH DOWN SYNDROME: A MOTOR CONTROL PERSPECTIVE WITH IMPLICATIONS FOR PEDAGOGICAL INTERVENTION

Available online at ScienceDirect. Procedia Engineering 112 (2015 )

3.1.3 Weight. Frequency. Weight is obtained at the baseline examination and annually. Equipment

Statistical Analysis of PGA Tour Skill Rankings USGA Research and Test Center June 1, 2007

A Cost Effective and Efficient Way to Assess Trail Conditions: A New Sampling Approach

Clinical view on ambulation in patients with Spinal Cord Injury

Changes in speed and efficiency in the front crawl swimming technique at 100m track

Transcription:

1060 ORIGINAL ARTICLE Reliability and Validity of the Shaw Gait Assessment Tool for Temporospatial Gait Assessment in People With Hemiparesis Sheila Reid, MS, Jean M. Held, EdD, Suzanne Lawrence, BS ABSTRACT. Reid S, Held JM, Lawrence S. Reliability and validity of the Shaw gait assessment tool for temporospatial gait assessment in people with hemiparesis. Arch Phys Med Rehabil 2011;92:1060-5. Objective: To assess the intra-/interrater reliability and the validity of the free web-based Shaw Gait Assessment Tool (with visual and numerical output) for assessing speed, cadence, step length, and limb advance time in people with hemiplegic gait. Design: Intra-/interrater reliability and concurrent validity with 2 raters using the Shaw Gait Assessment Tool and 1 rater using a multimemory stopwatch. Setting: Busy outpatient rehabilitation gym at a tertiary care medical center. Participants: Convenience sample of adults with hemiplegic gait after cerebrovascular accident or traumatic brain injury. Interventions: Not applicable. Main Outcome Measures: Intraclass correlation coefficients (ICCs) and Pearson product-moment correlation coefficients. Results: ICCs for intrarater reliability ranged from 0.94 (95% CI, 0.88 0.97) to 0.98 (95% CI, 0.96 0.99), (P.001), and for interrater reliability from 0.95 (95% CI, 0.88 0.98) to 0.99 (95% CI, 0.99 0.99), (P.001). The Shaw Gait Assessment Tool correlated with the stopwatch for all measured gait parameters with Pearson productmoment correlation coefficients (range, r 0.95 to r 0.99, P.001). Conclusions: The Shaw Gait Assessment Tool is a free, easy-to-use tool that gives reliable and valid results for 4 temporospatial parameters of hemiplegic gait. Key Words: Adult; Gait; Hemiplegia; Rehabilitation; Reproducibility of results. 2011 by the American Congress of Rehabilitation Medicine GAIT IMPAIRMENTS AND deviations resulting from brain injury are common and often lead to disability. 1-3 The ability to walk has been rated as one of the most important goals of rehabilitation by patients with stroke. 4 Gait assessment From Rehabilitation Therapies, Fletcher Allen Health Care (Reid, Lawrence); and the Department of Rehabilitation and Movement Science (Emerita), University of Vermont (Held), Burlington, VT. Presented to the American Physical Therapy Association, June 10 13, 2009, Baltimore, MD. No commercial party having a direct financial interest in the results of the research supporting this article has or will confer a benefit on the authors or on any organization with which the authors are associated. Reprints will not be available from the author. Correspondence to Sheila Reid, MS, Rehabilitation Therapies, C/O Ste 102, Room 111, Medical Office Building, 792 College Pkwy, Colchester, VT 05446, e-mail: Sheila.reid@vtmednet.org. Reprints are not available from the author. 0003-9993/11/9207-00989$36.00/0 doi:10.1016/j.apmr.2011.02.014 and treatment are integral components of the rehabilitation process from both the clinicians and patients viewpoints. PTs are well trained to evaluate and treat gait deficits; however, they need reliable, valid, and efficient methods of measuring gait. Gait has been examined in numerous ways. On one end of the spectrum, there is the very basic observational gait analysis, 5 which is probably the most commonly used clinical tool, simply because there is no equipment required. On the other end of the spectrum, there are motion and gait analysis laboratories, which can include video monitoring, electromyogram, and ground reaction force assessments. 5 Observational gait analysis does not give quantifiable temporospatial information, and with the exception of push-off, has been shown to be only moderately reliable. 6,7 Motion analysis laboratories provide detailed information on many aspects of gait, but they tend to be located in university settings or specialized research hospitals and are therefore not available to most clinicians. Over the years, a variety of tools have been developed for clinical use. The stopwatch is an affordable tool for measuring gait speed and, if the stopwatch has multimemory capability, cadence, average stride length. 8 For any temporospatial aspect other than speed, post hoc calculations are required, which are time consuming, not feasible in most busy clinical environments, and do not provide immediate visual feedback for the patient. Researchers have used video cameras with a grid, 9,10 in conjunction with a personal computer, 11 or ink footprints and a stopwatch 12,13 to record gait and measure various temporospatial parameters. These systems, although affordable, also require time-consuming post hoc analysis. Tools like the Stride Analyzer or the GAITRite System remain too costly for many clinics or hospitals. Based on a recent survey, 1826 physiotherapists in the United Kingdom indicated that management of abnormal gait constituted a major aspect of physiotherapy practice, yet there was no systematic use of standardized tools. 14 Over 50% of the therapists in the survey had not received formal training in gait assessment. Of the therapists who responded, the 5 most frequently stated features of an ideal gait assessment tool were that it be: (1) easy to use, (2) quick to use, (3) reliable, (4) clear and easy to understand, and (5) valid. Operationally, the tool is easy to use and quickly translated. It takes 10 to 20 minutes to administer the assessment and obtain results. 14 To meet the need, a PT clinician developed the Shaw Gait Assessment Tool a in 2001. It is a free, web-based temporospatial gait assessment tool, which is accessible by anyone with Internet access, and includes simple to follow directions and a tutorial for new users. Users can choose either English or metric measurements and can also specify the length of the testing walk. The data are immediately available in a graphical ICC PT List of Abbreviations intraclass correlation coefficient physical therapist

TEMPORAL GAIT ASSESSMENT IN HEMIPLEGIA, Reid 1061 Fig 1. Sample printout from the Shaw Gait Assessment Tool. The dark section represents the patient s performance as compared to the paler age and sex-based norms. format for the clinician to review with the patient and are norm referenced for speed, cadence, and step length (fig 1). To our knowledge, no other freely available gait assessment tool gives such information instantaneously. This tool has been tested on a healthy adult population and found to have acceptable reliability and validity for the temporospatial measures of speed, cadence, step length, and limb advance time (an indirect measure of symmetry). 15 The tool has not been tested on people with gait impairments. The purposes of this study were to assess the intra- and interrater reliability and the concurrent validity of the Shaw Gait Assessment Tool for speed, cadence, step length, and right/left limb advance time in people with hemiplegic gait. Because this was a clinical setting, we wanted to use commonly accepted clinical measures, and the multimemory stopwatch offered us the ability to test for concurrent validity. Based on the work of Youdas et al, 8 the stopwatch is reliable and valid for speed, cadence, step length, and limb advance time in people with impairments, while Handa et al 16 have found the stopwatch to be reliable and valid for these measures in a healthy population. Our hypotheses were that the Shaw Gait Assessment Tool would demonstrate good inter- and intrarater reliability and good concurrent validity with the stopwatch in people with hemiparesis. METHODS Participants Participants were recruited from the inpatient and outpatient populations of our rehabilitation center. Inclusion criteria were as follows: men or women aged 18 years or older, acute or chronic hemiparesis acquired in adulthood, stable medical condition, FIM score of 4 or higher, and the ability to walk 6m for 5 times without becoming distracted to the point of stopping their forward progress. Participants needed to understand the information in the informed consent and Health Insurance Portability and Accountability Act forms and to be able to follow study instructions. People were excluded if they had a medical condition that might limit their participation in the study, for example, recent total joint replacement or unstable cardiac condition. To evaluate reliability, we determined that we would need 26 subjects using the ICC 2,1 analysis of variance, a large effect size (F 0.40), power equal to 80%, and alpha equal to 0.05. 17 To evaluate concurrent validity, for a correlation of r equal to 0.9 (or r 2 0.8) with 95% power for significance, we needed 8 subjects. For an r equals 0.95 (r 2 0.9), we needed 9 subjects. 18 The study was approved by the Committee on Human Research at the University of Vermont. Rater Training The 2 raters using the Shaw Gait Assessment Tool and laptops took the short online tutorial. With healthy adults as subjects, the 3 raters then met for several practice sessions and resolved any questions or differences in execution, much as any PTs using a new tool might do. Testing Protocol Testing took place in a busy outpatient gym during normal treatment hours, but did not interfere with participants ongoing therapy. Black electrical tape was used to mark off a 10-m walkway. Measurements were taken for a 6-m distance, with 2m before and after the start/finish lines to allow participants to start and stop the walk with a gradual increase/decrease in speed. (fig 2). One practice walk was followed by 2 test walks at a comfortable pace (separated by 2min). After a 15-minute rest, 2 more test walks were performed separated by a 2 minute rest, for a total of 4 test walks. Four walks were chosen to provide more data for reliability testing, while still remaining within 1 test session and causing less inconvenience to the subjects. Participants wore a gait belt for safety and an aide provided guarding from the nonhemiplegic side. Because guarding by the aide could have obstructed a good view of foot contact, each walk was in the same direction with the aide on the side of the participant farthest from the testers. (People were wheeled back to the original start line to minimize fatigue.) We anticipated that people might lose their balance during the walk. Loss of balance was defined as a disruption of the person s specific gait pattern, staggering, or need for assistance to continue with the walk. If loss of balance occurred, data from that walk were not saved. Based on the therapists clinical judgment and the willingness of the participant, 1 replacement walk could be performed as long as there was at least a 2-minute rest after the previous walk. If a replacement walk was not possible, only data from the walks without loss of balance were used for analysis. Infrequently, a therapist realized that she had missed counting a step or had pressed the right (or left) arrow key twice consecutively. If this happened during testing in a clinical situation, the test would be repeated, so we felt that therapist fault was another valid reason for asking the participant to perform an additional walk. Because only 1 additional walk was permitted, if a therapist made an error during more than 1 test walk, only data from the remaining therapists were used in analysis for that test walk. Of the 312 test walks (26 participants 4 test walks 3 testers), we lacked data for 13 test walks. Data were collected by 2 therapists using the Shaw Gait Assessment Tool on laptop computers and by 1 therapist hold-

1062 TEMPORAL GAIT ASSESSMENT IN HEMIPLEGIA, Reid 6 m walkway 2 m ramp up/down Laptop 1 Laptop 2 2 m ramp up/down Stopwatch Fig 2. Schematic representation of the position of the walkway and the 3 testers. Please note, the walkway was simply a series of tape marks on the gym floor. ing a multimemory stopwatch. The 2 Shaw Gait Assessment Tool testers sat approximately 1.8m (6ft) apart on each side of the midpoint of the 6-m walkway. The person using the multimemory stopwatch stood between and slightly behind the Shaw Gait Assessment Tool testers (see fig 2). As study participants crossed the start line, testers using the laptops pressed the right arrow key if the right foot crossed first and the left arrow key if the left foot crossed first. Testers continued to hit right and left arrow keys coinciding with right and left foot strikes thus counting the number of steps the subject took to cover the 6m. When subjects crossed the finish line, the testers hit the s (for stop) key. Based on the step count (c), the distance covered (d), and the time elapsed (t), the program then calculated the speed, cadence, step length, and limb advance time. The computer performed calculations for each walking trial: (1) gait speed: S d/t, (2) cadence or step frequency: C c/t, (3) average step length: L d/c, and (4) limb advance time average: T b [t/c] both, T l [t/c] left,t r [t/c] right. Because gait can be asymmetric even in people without pathology, but definitely in people with hemiplegic gait, the Shaw Gait Assessment Tool derives a measure of symmetry based on the limb advance time (a term seldom used by clinicians). Any systematic variability in the time interval separating 1 footfall from the next is quantified by averaging these intervals for all right and left steps to yield the right (and left) limb advance time in seconds. The person holding the stopwatch used the lap/split feature of the stopwatch to record consecutive footfalls. If a participant crossed the start line with his/her left foot first, the stopwatch tester bent her left elbow to 90 forming an L (for left). She kept her arm down by her side if the right foot crossed the start line first. During the breaks between test walks, the stopwatch tester wrote down all the stopwatch data using the recall button, and indicated whether the test began with the right or left foot. Later that day, the stopwatch tester manually entered the data (elapsed time for each step and whether test started with right or left foot) into a program that replicated the Shaw Gait Assessment Tool calculations. The program (provided by the Shaw Gait Assessment Tool developer) was used to derive step length, cadence, speed, and limb advance time. Data Analysis All analyses were conducted using SPSS 15.0 for Windows b An alpha level of 0.05 was set as acceptable. ICCs with 95% confidence intervals were calculated to evaluate intra- and interrater reliability for all variables: speed, cadence, step length, limb advance time left, and limb advance time right. Intrarater reliability for each of the 3 raters (laptop 1, laptop 2, and stopwatch) was determined using a 2-way mixed model and absolute agreement type. Interrater reliability (laptop 1, laptop 2) was determined using a 2-way random effects model and absolute agreement type. Absolute agreement was chosen because it measures whether raters assign the same absolute score. An ICC greater than 0.9 was set as acceptable. The Pearson product-moment correlation coefficient was used to determine the concurrent validity of the Shaw Gait Assessment Tool compared to the multimemory stopwatch for gait speed, cadence, step length, limb advance time left, and limb advance time right. Separate correlation coefficients were obtained by comparing each laptop s data with the stopwatch result. RESULTS Sixteen men and 10 women participated in the study. Their ages ranged from 19 to 85 years (mean SD, 58 19y). Length of time since onset of brain injury ranged from 0.5 to 66 months (mean SD, 11.7 16.96mo). Fifteen people had right-sided hemiplegia, while 11 had left-sided involvement. Sixteen participants used some type of lower-extremity bracing, while 10 did not; 19 people used a cane, 2 used a rolling walker, and 5 used no assistive device. Table 1 presents the means, SDs, and coefficients of variation for the gait parameters of speed, time, average step length, and cadence for all 3 raters. Table 2 shows the ICCs for intrarater reliability for both laptops and the stopwatch for all gait parameters. The intrarater reliability for both methods was excellent for all gait parameters measured, with the ICCs (model 2) for the laptops ranging from 0.94 to 0.98, and for the stopwatch ranging from 0.96 to 0.98 (all P.001). Table 3 shows the range of ICCs for interrater reliability for all trials and parameters for the laptop users. ICCs (model 2) ranged from 0.95 to 0.99 (P.001), demonstrating excellent interrater reliability. Pearson product-moment correlations for each laptop with the stopwatch are shown in table 4 for all gait parameters. All correlations were 0.95 or higher, with P.001, demonstrating that the Shaw Gait Assessment Tool is valid compared to the multimemory stopwatch

TEMPORAL GAIT ASSESSMENT IN HEMIPLEGIA, Reid 1063 Table 1: Means SD and Coefficients of Variation for Both Laptops and the Stopwatch Raters for Time, Speed, Cadence, and Average Step Length Raters Time (s) Speed (m/s) Step Length (cm) Cadence (steps/min) Laptop 1 (n 97) Mean SD 10.36 4.66 1.19 0.46 46.80 12.21 83.97 20.52 CV (%) 44.98 38.63 26.09 24.44 Laptop 2 (n 99) Mean SD 10.40 4.72 1.18 0.47 46.63 12.60 84.28 20.69 CV (%) 45.38 39.64 27.02 24.56 Stopwatch (n 100) Mean SD 10.16 4.58 1.20 0.46 47.45 11.85 84.71 19.86 CV (%) 45.08 38.11 24.97 23.44 Abbreviation: CV, coefficient of variation. DISCUSSION In evaluating reliability and validity of the Shaw Gait Assessment Tool, we wanted to ensure that whatever results we obtained would represent its use in a typical clinical setting. To that end, the study was carried out in a busy outpatient rehabilitation gym with many distractions (for both participants and raters), and not in a quiet gait lab or testing room. The greater than 0.94 ICCs for all variables demonstrate excellent intraand interrater reliability in a real-life setting. As stated earlier, we deliberately used the ICC because it assesses not only correlation, but agreement and generalizability as well. 17 Strengthening the generalizability of the Shaw Gait Assessment Tool is the fact that the 2 Shaw Gait Assessment Tool raters trained themselves using the online tutorial, as any new user would need to do. New users of this tool will not have access to the developer, so it is encouraging to know that with the online tutorial and a few practice sessions, raters can expect excellent inter- and intrarater reliability. Also adding to the generalizability of the study was the heterogeneity of our study population. Length of time since onset of hemiplegia ranged from 0.5 to 66 months; the ages Table 2: Intrarater Reliability (ICC model 2) for Laptop 1, Laptop 2, and the Stopwatch Gait Parameters ICC (95% confidence interval) F (df) Speed Laptop 1 0.98 (0.96 0.99)* 185.6 (20,60) Laptop 2 0.98 (0.96 0.99)* 200.7 (21,63) Stopwatch 0.98 (0.96 0.99)* 182.3 (22,66) Cadence Laptop 1 0.98 (0.96 0.99)* 170.7 (20,60) Laptop 2 0.98 (0.96 0.99)* 166.1 (21,63) Stopwatch 0.97 (0.99 0.99)* 134.7 (22,66) Step length Laptop 1 0.96 (0.93 0.98)* 121.4 (20,60) Laptop 2 0.96 (0.93 0.98)* 111.8 (21,63) Stopwatch 0.96 (0.93 0.98)* 97.2 (22,66) Limb advance time left Laptop 1 0.98 (0.96 0.99)* 173.3 (20,60) Laptop 2 0.98 (0.96 0.99)* 178.7 (21,63) Stopwatch 0.97 (0.94 0.99)* 127.4 (22,66) Limb advance time right Laptop 1 0.94 (0.88 0.97)* 60.2 (20,60) Laptop 2 0.95 (0.91 0.98)* 80.1 (21,63) Stopwatch 0.96 (0.93 0.98)* 82.3 (22,66) *P.001. spanned from 18 to 85 years; gait speeds were as slow as.42m/s and as fast as 2.8m/s, while average step length varied from 17.14cm to 66.67cm. Table 1 summarizes the temporospatial data for speed, time, average step length, and cadence for all 3 raters. Based on the small sample size, it would not be prudent to use these data to calculate a minimal detectable change, however. The data in table 1 are provided so that clinicians can compare their patients to our study population. Limb advance time is not included in the table because the Shaw Gait Assessment Tool does not differentiate involved from noninvolved side, only right from left. Because there were 16 people with right-sided hemiplegia and 11 with left-sided hemiplegia, longer-limb advance times would be expected on different sides. These aggregate data therefore essentially negate the measure of asymmetry compared to looking at 1 person s results. Table 3: Interrater Reliability (ICC model 2) comparing Laptop 1 With Laptop 2 Gait Parameters ICC (95% confidence interval) F (df) Speed Trial 1 0.99 (0.98 0.99)* 258.597 (23,23) Trial 2 0.99 (0.99 0.99)* 925.069 (23,23) Trial 3 0.99 (0.99 0.99)* 478.413 (21,21) Trial 4 0.99 (0.98 0.99)* 176.159 (24,24) Cadence Trial 1 0.99 (0.98 0.99)* 222.635 (23,23) Trial 2 0.99 (0.99 0.99)* 337.459 (23,23) Trial 3 0.99 (0.98 0.99)* 342.113 (21,21) Trial 4 0.99 (0.99 0.99)* 297.408 (24,24) Step length Trial 1 0.99 (0.99 0.99)* 375.568 (23,23) Trial 2 0.99 (0.98 0.99)* 185.242 (23,23) Trial 3 0.99 (0.97 0.99)* 143.673 (21,21) Trial 4 0.99 (0.97 0.99)* 148.525 (24,24) Limb advance time left Trial 1 0.99 (0.98 0.99)* 231.600 (23,23) Trial 2 0.97 (0.93 0.99)* 69.086 (23,23) Trial 3 0.96 (0.90 0.98)* 43.611 (21,21) Trial 4 0.98 (0.96 0.99)* 118.103 (24,24) Limb advance time right Trial 1 0.98 (0.95 0.99)* 93.713 (23,23) Trial 2 0.98 (0.95 0.99)* 85.607 (23,23) Trial 3 0.95 (0.88 0.98)* 36.599 (21,21) Trial 4 0.97 (0.94 0.99)* 67.388 (24,24) *P.001

1064 TEMPORAL GAIT ASSESSMENT IN HEMIPLEGIA, Reid It may be helpful to elaborate on the parameter step length. As explained in the Methods section, average step length is calculated by dividing the distance covered (walkway length) by the step count. Because a subject s first or last footfall may be very close or up to a step length away from the start or finish line, the actual distance covered may not be identical to the length of the walkway. The Shaw Gait Assessment Tool uses the walkway length for the average step length calculation; therefore, one might question the validity of the Shaw Gait Assessment Tool calculated step length. The Elite motion analysis system uses an actual distance traveled to calculate step length. In the study with healthy adults where the Shaw Gait Assessment Tool was compared to the Elite, Pearson product-moment correlations ranged from 0.87 to 0.92. 15 The issue of distance of the initial/last footfalls from the start/finish lines is the same whether a person is a healthy adult or has hemiparetic gait. Despite the potential differences when using actual distance walked versus walkway length, Shaw Gait Assessment Tool average step length calculations appear to be valid. 15 The Shaw Gait Assessment Tool does not have the ability to perform separate averages for right and left, so it calculates an overall step length average. If a person s gait is very asymmetric, this average step length may not be very informative when viewed in isolation. Considering the right- and left-limb advance times will give a clinician an idea of the symmetry or asymmetry of the gait pattern. The goal would be to have right- and left-limb advance times be as close to one another as possible. However, we would not want patients to improve their symmetry at the expense of their step length. Two-step lengths equal 1 stride; therefore, noting improvements in symmetry of limb advance time without a decrease in step/stride length may help clinicians chart patients progress. It could be argued that having the laptop and stopwatch users stationed fairly close to one another may have resulted in inadequate blinding. The laptops users were seated about 1.8m (6ft) apart, with the stopwatch user slightly behind, but in between them. As mentioned above, the testing took place in a busy, noisy outpatient rehabilitation gym. Occasionally, people would inadvertently walk across the walkway during testing. Testers had to remain very focused on the actual walk, while attempting to ignore the distractions. The testers needed to look straight ahead to be able to observe the subjects walk and could not have seen other testers keystrokes. In addition, both the arrow keys and the stopwatch buttons produced some level of noise when pressed, so in effect, 3 people s keystrokes would have needed to synchronize to skew the results possible, but we feel unlikely. We chose the stopwatch as our measure of concurrent validity because it is so widely used in clinical practice due to its availability and affordability. Pearson product-moment correlations greater than 0.95 for all variables reveal a strong correlation between the stopwatch and the Shaw Gait Assessment Tool, leading to the conclusion that the Shaw Gait Assessment Tool has strong concurrent validity with the stopwatch. The Shaw Gait Assessment Tool has also proven reliable and valid with healthy adults when using the Elite motion analysis system as the criterion standard. 15 One might question the necessity of using the Shaw Gait Assessment Tool when a stopwatch is so readily available and inexpensive. As stated previously, speed, cadence, and step length each require a posttest calculation. Limb advance time would require a much more time consuming calculation. None of the results calculated with the stopwatch Table 4: Validity (Pearson product-moment correlations) Between Laptop 1 and the Stopwatch and Between Laptop 2 and the Stopwatch Raters Speed Cadence Step Length Limb Advance Time (left) Limb Advance Time (right) Laptop 1:stopwatch 0.99* 0.99* 0.99* 0.97* 0.95* Laptop 2:stopwatch 0.99* 0.99* 0.98* 0.98* 0.95* *P.001. would be available for visual reinforcement and many people respond well to visual learning and information. Computers are becoming an integral part of many clinics and hospital rehabilitation facilities, which are also offering Wi-Fi Internet access for patients and guests; this is certainly the case in the United States. In fact, many facilities have already switched to an electronic medical record, with additional facilities changing over almost daily, with ready access to computers for clinical staff, and Wi-Fi availability ensuring easy access to the Internet. After completing a test, users have the option of copying the numerical (not graphic) results into an electronic health record or printing the test results, an option which will preserve the graphs, so there should be no issues of patient confidentiality. Assessment of gait speed has become more prevalent and important over the past few years. Gait speed is a powerful indicator of function and prognosis after stroke. It can be stratified into clinically meaningful functional ambulation classes and is a strong measure of physical decline. 19 An improvement in gait speed that puts a person in a higher class of ambulation (eg, household vs community) results in better function and quality of life. 19 The Shaw Gait Assessment Tool provides more data than just speed; however, and information such as step length, cadence, and left-right symmetry (as measured by right- and left-limb advance times) can be used to aid in the choice of an ankle foot orthosis, with some devices producing greater improvements than others. 20 Study Limitations We did not happen to enroll anyone with foot drag into our study. Because the Shaw Gait Assessment Tool calculations are based on foot contact, this tool would not be useful in people with foot drag and is a limitation of the tool. CONCLUSIONS The results of this study provide evidence to support strong inter- and intrarater reliability and concurrent validity of the Shaw Gait Assessment Tool in people with hemiplegic gait. Clinicians can now have access to a tool that is efficient, affordable, and easy to use, and which will give them information other than gait speed in a timely manner. Future research with this tool could include populations such as people with amputation, people with other neurologic diagnoses, or people after orthopedic surgery. Acknowledgements: We would like to thank Tony Shaw, PT, for developing the Shaw Gait Assessment Tool and continuing to improve it based on clinical needs; Karen Stoneman, PTA, for participating in data collection as one of the raters; and Alan Howard, MS, for ongoing statistical help. Support in the form of time for working on the project and data collection was provided by Rehabilitation Therapies at Fletcher Allen Health Care.

TEMPORAL GAIT ASSESSMENT IN HEMIPLEGIA, Reid 1065 References 1. Hillier SL, Sharpe MH, Metzer J. Outcomes 5 years posttraumatic brain injury with further reference to neurophysical impairment and disability. Brain Inj 1997;11:661-75. 2. Ochi F, Esquenazi A, Hirai B, Talaty M. Temporal-spatial feature of gait after traumatic brain injury. J Head Trauma Rehabil 1999; 14:105-15. 3. Bohannon RW, Horton MG, Wikholm JB. Importance of four variables of walking of patients with stroke. Int J Rehabil Res 1991;14:246-50. 4. Mumma CM. Perceived losses following stroke. Rehabil Nurs 1986;11:19-24. 5. Whittle MW. Methods of gait analysis. In Whittle MW. Gait analysis: an introduction. 4th ed. Burlington: Butterworth Heinemann; 2007. p 15597. 6. Krebs DE, Edelstein JE, Fishman S. Reliability of observational kinematic gait analysis. Phys Ther 1985;65:1027-33. 7. McGinley JL, Goldie PA, Greenwood KM, Olney SJ. Accuracy and reliability of observational gait analysis data: judgments of push-off in gait after stroke. Phys Ther 2003;83:146-60. 8. Youdas JW, Atwood AL, Harris-Love MO, Stiller TL, Egan KS, Therneau TM. Measurements of temporal aspects of gait obtained with a multimemory stopwatch in persons with gait impairments. J Orthop Sports Phys Ther 2000;30:279-86. 9. Wall JC, Devlin J, Khirchof R, Lackey B. Measurement of step widths and step lengths: a comparison of measurements made directly from a grid with those from a video recording. J Orthop Sports Phys Ther 2000;30:410-7. 10. Wall JC, Crosbie J. Temporal gait analysis using slow motion video and a personal computer. Physiotherapy 1997;83:109-15. 11. Gaudet G, Goodman R, Landry M, Russell G, Wall JC. Measurement of step length and step width: a comparison of videotape and direct measurements. Physiother Can 1990;42:12-5. 12. Holden MK, Gill KM, Magliozzi MR, Nathan J, Piehl-Baker L. Clinical gait assessment in the neurologically impaired. Reliability and meaningfulness. Phys Ther 1984:64:35-40. 13. Riley M, Goodman M, Fritz VU. An objective measure of gait using ink footprints. South African Journal of Physical Therapy 1999;55:8-11. 14. Toro B, Nester CJ, Farren PC. The status of gait assessment among physiotherapists in the United Kingdom. Arch Phys Med Rehabil 2003;84:1878-84. 15. Reid S, Shaw A, Haugh LD. Validity and reliability of an internetbased temporal gait assessment tool with healthy adults: a pilot study. Arch Phys Med Rehabil 2005;86:1014-8. 16. Handa T, Sahara R, Yoshikazi K, et al. Examination of reliability and validity of walking speed, cadence, stride length comparison with stopwatch and three-dimension motion analyzer. J Phys Ther Sci 2007;19:213-22. 17. Portney LG, Watkins MP. Foundations of clinical research. Applications to practice. 3rd ed. Upper Saddle River: Pearson Prentice Hall; 2009. 18. QueryAdvisor. Available at: http://www.statsol.ie/nquery/ nquery.htm. Accessed June 22, 2005. 19. Schmidt A, Duncan PW, Studenski S, et al. Improvements in speed-based gait classifications are meaningful. Stroke 2007;38: 2096-100. 20. Gök H, Küçükdeveci A, Altinkaynak H, Yavuzer G, Ergin S. Effects of ankle-foot orthoses on hemiparetic gait. Clin Rehabil 2003;17:137-9. Suppliers a. Free web tool. Available from: http://www.theralink.com/apps/sga/. b. SPSS Corp, 233 S Wacker Dr, 11th Fl, Chicago, IL 60606.