Liquid Level Controllers

Similar documents
SERIES 30. Spring Operated Tank Blanketing Valve PROTECTOSEAL.

SINGLE VALVE WITH LOW-FLOW BYPASS

A050-1/2 INCH AIR OPERATED double DIAPHRAGM PUMP

The Shand & Jurs Model Vapor Guard Tank Blanketing Valve

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified

shutoff valves 900 Series psig Manual Shutoff Valves

WaterSource Heat Pump Hose Kit Performance Specification-Summary

Low-pressure diaphragm pumps for product feeding Feeding

Brooks Flow Controllers for Gas and Liquid Service Model FC 8744, Series FC 8800 and FC 8900

Air Operated Hydraulic Pumping Systems to 50,000 psi

Model DE-1, VDE-1 and DE-2 Air Release Heads

1200 Series Pressure Regulators

Pressure and/or Temperature Pilot Operated Steam Regulators Series 2000

Variable Area Flow Meters

Air Eliminators and Combination Air Eliminators Strainers

SERIES 10. Pilot Operated Tank Blanketing Valve, 2" PROTECTOSEAL.

CFC2. Float Control For Closed Tanks MODEL. Specifications. Dimensions (In Inches) Reservoir Connection 1" NPT (Typ. Both Ends 2 Places)

IP2, IP2A and IP2D. Spirax-Monnier International Compressed Air Filter/ Regulators

670 Series Panel-Mounted Loading Regulators

KEYSTONE. A C E C O E n v i r o n m e n t a l C o m p a n y. Bulletin 10-B

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.

94270 Vapor Guard Tank Blanketing Valve Vapor Guard Tank Blanketing Valve What is Tank Blanketing? Features How does it work?

Air Amplifiers & SYSTEMS

EOM PX1500. Engineering Operation & Maintenance. Advanced Series Metal Pump. WIL E-10 Replaces WIL E-09

CVI Valve Line. Exceeds the industry s highest standards for reliability and performance

Type 4708 Supply Pressure Regulator

FILTER BYPASS CONTROL

hydro-pac, inc. Low-Pressure Gas Compressors 1500 to 6000 PSI

FIK In-Tank Filters FIK. Max Flow: 170 gpm (643 lpm) Working Pressures to: Rated Static Burst to: Flow Range to:

4194 Series Differential Pressure Indicating Controllers

PumpAgents.com - Click here for Pricing/Ordering Nominal psi (bar) Cut-In Cut-Out

Model 4000 Pressure Controller

Varea-Meter Flowmeters. For Metering and Controlling Flows of Process Fluids

829S1 Series Flexflo Pilot

DataSheet. Series AA Electronic Metering Pumps. Configuration Data. Dimensions. Specifications. Model AA HI. ISO 9001 Certified

Type 4708 Supply Pressure Regulator

BERMAD Waterworks. Level Control Valve with Altitude Pilot. 700 Series. Model X. Features and Benefits. Major Additional Features

VAREC 180 SERIES PRESSURE REGULATORS

Standard Operating and Maintenance Instructions for Pumping System Model PS-90

SULLAIR SX Filtration Series ,000 scfm

FAST & FLEXIBLE EXPERTISE 100% ORDER FULFILLMENT LOW COST PROVIDER

CASH VALVE TYPE KP BACK PRESSURE VALVES

Fisher 4194 Differential Pressure Indicating Controllers

IP2M, IP2AM and IP2DM Monnier International Compressed Air Filter/ Regulators

BACK PRESSURE / SUSTAINING

AIR DRIVEN. Gas Boosters & SYSTEMS. Accepting VISA, MasterCard and American Express

1 8 A N D 2 8 S E R I E S

BACK PRESSURE / SUSTAINING

BUBBLER CONTROL SYSTEM

SPECIFICATIONS. Approximate Weight: 10 oz. Surface Finish: Ra micro inch or less MATERIALS OF CONSTRUCTION

P3000 Series. Pneumatic Deadweight Testers Model P3000. Technical Data. Features

P400/PX400. Advanced Series METAL Pumps. Advance your process. Engineering Operation & Maintenance WIL E-12 REPLACES WIL E-11

Gas Boosters & Systems

RCD - Ultra-Rugged Differential Pressure Flowmeter

ROYTRONIC EXCEL TM Series AD Electronic Metering Pumps

P400/PX400. Advanced Series METAL Pumps. Advance your process. Engineering Operation & Maintenance WIL E-07 REPLACES WIL E-06

BULLETIN FOR ACCURATE INDICATION AND CONTROL OF GAS AND LIQUID FLOW IN LOW RANGES.

Cash Valve TYPE G-4 PILOT OPERATED PRESSURE REDUCING REGULATOR FOR STEAM, AIR AND GASES. ISSUED - MARCH 2001 CAVMC-0512-US-0208 ISO 9001 Certified

INDUSTRIAL EXCESS ESS FLOW VALVES

Model 10. Low-Medium Pressure Reducing Regulator

Series 2G Diaphragm Actuators

TECHNICAL DATA. Page 1 of 12

GH & GHL Series Gas-Over-Oil Valve Actuators

Type Pressure Regulator. for increased air capacity. Fig. 1: Type Pressure Regulator. Mounting and Operating Instructions EB EN

Avenger Model 33M Installation & Operation Instructions

Related Products: Auto Drain Valve. Model/Specifications. Model

VACUUM REGULATORS CONTENTS

SG3 Series Regulators - Pressure Reducing

NC MAGNETIC FLOAT SWITCHES FOR LIQUIDS

TECHNICAL DATA. Pressure Regulation 531a. April 24, 2009

V248 Series 3-Way Pressure-Actuated. Water-Regulating Valves for High-Pressure

Product Overview A DIVISION OF MARSH BELLOFRAM

Choosing the right miniature instrument and control valve is a snap

Pilot valves for pilot operated servo valves

OPERATION MANUAL. ALUMINUM Models 316 S.S. Models AIR-OPERATED DOUBLE DIAPHRAGM PUMPS

Air Preparation. Regulators, Pressure Regulators, Lubricators and Accessories. Keeping the World Flowing

DTG - LCD Digital Temperature Gauge USER MANUAL

BUBBLER CONTROL SYSTEM

B84G - Excelon Plus Modular System General purpose filter/regulator

lternative odels 3.87 (98) anual Drain 2.67 (68) 3.72 (94) utomatic Drain 2.13 (54) 1.12 (28) P1H, PTH Filter/Regulator-Lubricator Combination Units 0

P800/PX800. Advanced Series METAL Pumps. Advance your process. Engineering Operation & Maintenance WIL E-12 REPLACES WIL E-11

FloWash. Industrial Filter Cart

Water Solenoids Safety Valves Air. Meters. Butterfly Ball Gate Globe Strainers Pressure Gauges Thermometers

Cash Valve. Type G-4. Pilot Operated Pressure Reducing Regulator for Steam, Air and Gases. Flow Control

TECHNICAL ACCESSORIES

Model Series 62 Constant Differential Relay

COMPRESSED AIR DISTRIBUTION SYSTEMS

61 Series Pilots for Pilot-Operated Pressure Reducing Regulators

Electropneumatic Transducer (I/P) Installation, Operation and

Pneumatic Hand Pumps with no Gauge Connection (scissor handle) AP0V (300 psi / 20 bar)

P3000 Series. Pneumatic Deadweight Testers Model P3000. Technical Data. Features

V43 Pressure Actuated Water Regulating Valve

Flow Measurement Equipment Armored Purge Meters

Fisher 4194H Differential Pressure Indicating Controllers

Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators

TECHNICAL DATA CAUTION

ROUGHNECK II Pumpless Drain

TECHNICAL DATA. Q = C v P S

Becker Precision Equipment

MODEL MN-PWV PRESSURIZED WATER VESSEL ASSEMBLY OPERATING MANUAL

Transcription:

Liquid Level Controllers ALL PUMPS LLC-2Y For both pump up and down control. Variable On/Off set points. NDP-15/20/25/32, DP-10/15 & *NDP-40/50/80 LLC-1 Pump up and down versions available. 6 to 12 differential On/Off. *In conjunction with power valve. DP-10/15, NDP-40/50/80 & SolidPRO LLC-1010 Pump down only. 6 differential On/Off set points. NDP-5/15 & DP-10 LLC-3 For both pump up and down control. Variable On/Off set points. NDP-20/25/32 LLC-4 Utilized unit. Pump down only. 6 differential On/Off (similar to LLC-1) Note: Due to Yamada s continued commitment to product improvement, specifications may change without notice.

LLC-2Y The Yamada LLC-2Y Liquid Level Controller is a totally pneumatic system designed to automatically start and stop Yamada Air-Operated Double Diaphragm when the liquid level within a tank, sump, etc. reaches predetermined levels. An extremely versatile controller, the LLC-2Y can be used in both single and dual pump applications with any size or model Yamada Pump. Used in a single pump configuration, it automatically controls either the filling or emptying of a tank or other vessel. When connecting to two separate pumps, it will control both the filling and emptying of the tank. This dual pump capability is particularly useful for waste water storage, contaminated water clean-up and other applications where liquids are regularly transferred into and out of a single vessel. Key Advantages Totally Pneumatic Operation: Compressed air to operate the pump is all that is required. Broad Control Capabilities: The LLC-2Y can be utilized with any Yamada Pump to control and maintain a liquid level anywhere from a few inches to dozens of feet within a tank, sump, etc. Wide Range of Applications: Connected to a single pump, it is ideal for either filling or emptying a tank or vessel. Connected to two pumps, it can be used to control both the filling and emptying. Specifications Operating style Setting Operating pressure range Pilot pressure Ambient and fluid temperature Lubrication Impact/Vibration resistance Dimensions Air operated style /NO (Changeable) 20-130 PSI Same as operating pressure Max 50 C Not required 150/50 m/s2 8.5 L x 7.0 W x 4.5 D Two 1/4 nylon tubes, cut to length High / Low Dip Tubes (20 supplied *) Air Supply Connections 3/8 Design Case Weather proof enclosure Weight 4 lbs. *Additional tubing available

LLC-2Y Principles of Operation The LLC-2Y consists of a sophisticated air logic control valve housed in an impact resistant weather proof fiberglass reinforced plastic enclosure. As the liquid level within the tank rises or falls, the subtle changes in pressure are transmitted through high and low level dip tubes to the air logic control valve. When the liquid level reaches a predetermined level (tubing is cut in the field to the preferred HIGH and LOW level points), the power valve supplying air pressure to the pump is turned ON or OFF as required. The LLC-2Y can be utilized to control and maintain liquid levels in virtually any un-pressurized vessel. Its liquid level control span ranges from a few inches to dozens of feet. For added convenience, it may be mounted up to 20 feet away from the pump.* * NOTE: The greater the distance from the liquid, the longer the reaction time for the pump to activate. Power Valve VGA342-04NA The VGA342-04NA Power valve is used in conjunction with the LLC-2Y. This 3-way air actuated solenoid valve enables the pump to receive an increased volume of air to drive the pump towards it s desired capacity. Signal from LLC-2y to VGA342 power valve Liquid Level Single Pump Configuration Dual Pump Configuration Emptying Filling Below both high and low dip tubes Pump Off Pump On Filling pump on. Emptying pump off Below high dip tube, above low dip tube Pump Off Pump On Filling pump on. Emptying pump on. Above both high and low dip tubes Pump On Pump Off Filling pump off. Emptying pump on. Below high dip tube, above low dip tube Pump On Pump Off Filling pump off. Emptying pump on. Installation: 1. Air supply IN (both LLC-2Y & power valve) 2. Control air supply OUT (to power valve) 3. Air supply from power valve to pump 4. High level sensor tube* 5. Low level sensor tube* * NOTE: Mount sensor tubing a minimum of 2-3 below the pre-determined level.

LLC-1 and LLC-1010 Yamada Liquid Level Controllers, LLC-1 and LLC-1010, are designed for controlling the liquid level in fluid reservoirs 12 inches or deeper. The reliable controllers can be utilized for either filling or emptying operations and are available for all models of Yamada. These liquid level controllers are pneumatically operated (no electricity required). Operation: LLC-1 Remote Mount Normally Closed The LLC-1 and LLC-1010 consist of a sensing tube (installed in the fluid) and valve head which is connected to the compressed air supply line in series with the pump. As the liquid rises in the sensing tube, air pressure within the tube increases. This increase in pressure is transmitted to a diaphragm (non-wetted) in the valve head (via a nylon tube for remote mount), activating an air pilot valve which OPENS or CLOSES the main valve, turning the air supply to the pump ON or OFF. A Normally Closed (air line closed) configuration would typically be used for an emptying application, such as a sump. A Normally Open (air line open) configuration would be used for a filling application, such as maintaining a tank level. Benefits: LLC-1010 Remote Mount Normally Closed LLC-1 Remote Mount Normally Open 9 Totally Pneumatic Operation: Compressed air to operate the pump is all that is required. On/Off reliability Energy efficient: Pneumatic operation Versatile: Good for emptying sumps or filling tanks Close differential at 5-6 Wide differential at 10-12 Floatless

LLC-1 and LLC-1010 Specifications: Model Filtered compressed air at 40 to 105 PSI, Temperature Range 35 to 180ºF, and Buna N diaphragm standard (nonwetted). PTFE is also available, consult Yamada. LLC-1SWD LLC-1: LLC-1NOCD Valve size: 1/4 NPT Maximum Flow: 35 SCFM Tubing: 25 feet of 1/4 Nylon Tubing (remote mount) LLC-1WD LLC-1CD LLC-1SCD Valve size: 1/2 NPT Maximum Flow: 195 SCFM Tubing: 25 feet of 3/8 Nylon Tubing (remote mount) Bracket included LLC-1 Remote Mount Valve Configuration Differential Dip Tube NDP-5/10/25 32/40/50/80 & DP-10/15 Wide (10-12 ) Wide (10-12 ) Stainless Close (5-6 ) Close (5-6 ) Stainless NO Close (5-6 ) NO Close (5-6 ) Stainless Steel Remote Steel Remote Stainless Series (1/4 to 3 ) LLC-1SN0CD LLC-1010 LLC-1010P LLC-1010R LLC-1010: For Pump Models LLC-1010RP LLC-1010RSS DP and NDP-40/50/80 Series (1-1/2 to 3 ) = Normally Closed NO = Normally Open P = Polypropylene R = Remote SS = Stainless Steel WD = Wide Differential CD = Closed Differential LLC-1010 Remote Mount LLC-1010 Direct Mount

LLC-3 Sump Pump This traditional float type system is designed for a 5 gallon pail or sump of equal depth. The pump is controlled by an internal float which actuates an air valve. As the liquid level in the sump rises, the pump automatically starts and operates until the liquid level drops below a predetermined level. The LLC-3 includes a DP-10BAN (3/8 ), Aluminum pump with Buna N diaphragms, complete float assembly (actuator and float ball with stem), filter-regulator gauge assembly, and suction pipe. All components are mounted on a 5 gallon pail cover. The system operates on air supply pressures from 20 to 100 PSI and can execute up to 6 GPM. The LLC-3 is perfect as a drain run-off relay-pumping station. Also available with the NDP-5 (1/4 ) and NDP-15 (1/2 ) series pumps. 12-1/4 DIA ALUMINUM LID 4-1/2 DIA SS FLOAT BALL

LLC-4 Floatless Sump Pump The LLC-4 is perfect for lowering into a tank or pit to pump out the last bit of liquid that the centrifugal pump could not remove. This air-powered sump pump is ideal for shallow sump applications. Its crisp on/off liquid level control works automatically, keeping liquid levels within the sump between 5 and 7 inches from the sump floor at all times. The LLC-4 consists of a Yamada NDP-20BPH (3/4 ) polypropylene pump with Hytrel diaphragms, level control, inlet strainer, manual bypass valve, compressed air ball valve, and filter regulator gauge assembly. It executes up to 28 GPM and is capable of 200 feet head with 90 PSIG. The system will operate on air supply pressures between 20 and 100 PSI and will fit in sumps as small as 14-15 inches. Available with any NDP-20/25/32 (3/4, 1 & 1-1/2 ) series pump. Consult Yamada for pricing.

Liquid Level Controllers Yamada is a registered trademark of Yamada America, Inc. Hytrel is a registered trademark of E.I. du Pont de Nemours and Company. The Proof s in the Pump is a registered trademark of Yamada America, Inc. Due to Yamada's continued commitment to product improvement, specifications may change without notice. Label: