Low Pressure Valve. Model Overview. Typical applications. Key features and benefits.

Similar documents
Pressure Sensing Valve - Model 4023

1805 Series Relief Valves

DEWATERING PUMP SOLUTIONS. Pneumatic pumps

Choosing the right miniature instrument and control valve is a snap

Installation, Operation and Maintenance Manual for Back Pressure Regulator

64 Series Pressure Reducing Regulators

SAFETY LOCKOUT VALVES

Series 1, 3 and 4 Cv = /8" and 1/4" Ported Manually Operated Valves. 3-way/2-position, 5-way/2-position, 5-way/3position

1805 Series Relief Valves

61 Series Pilots for Pilot-Operated Pressure Reducing Regulators

Type R622 Pressure Reducing Regulator

T208VR Series Tank Blanketing Vacuum Regulator

Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators

Precision and Instrument Regulators 1/4" port size

Types ACE95 and ACE95Sr Tank Blanketing Valves

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012

Type ACE95jr Tank Blanketing Valve

Types ACE95 and ACE95Sr Tank Blanketing Valves

Types ACE95 and ACE95Sr Tank Blanketing Valves

DANFLO Control Valves 400 Series Model 20

INSTRUCTION MANUAL. CVS P37 LP Gas Reducing Regulator

Proportional Pressure-Relief Cartridge Valve, Size 2...4

3 & 4-Way Mixing & Diverting Valves

1301 Series High-Pressure Regulators

TECHNICAL DATA. Q= Cv S

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

SPECIFICATIONS. Approximate Weight: 10 oz. Surface Finish: Ra micro inch or less MATERIALS OF CONSTRUCTION

1305 Series Pressure Reducing Regulators

TECHNICAL DATA CAUTION

WHEATLEY Series 822/820 Swing Check Valve

Rate of Flow Valve Series 120

Type FEQ Slam-Shut Valve

FILTER BYPASS CONTROL

TECHNICAL DATA. Q = C v P S

Type EZH Relief or Backpressure Regulator

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

Inverse Prop. Pressure-Relief Cart., Size 2 4

Type 1190 Low-Pressure Gas Blanketing Regulator

Type 310A-32A Pressure Reducing Regulator and Type 310A-32A-32A Working Monitor Regulator

JR Series. Gas Pressure Reducing Valves. a division of Jordan Valve GAS PRESSURE REDUCING VALVES

OPERATION MANUAL. ALUMINUM Models 316 S.S. Models AIR-OPERATED DOUBLE DIAPHRAGM PUMPS

Gas / Liquid sampling tool High pressure, manually operated. Version 2.2

PRESSURE COMPENSATORS TECNORD

Anti-flood device Model B-1

1/2 to 2-1/2 NPT; 0 to 230 PSI Advantages / Benefits

Mark 958 Series Sanitary Gas Back Pressure Regulators

Engineered Valves Group. Revision 2. FABRI-VALVE High Performance Knife Gate Valve.

Type EZL Pressure Reducing Regulator for Low Differential Pressure Applications

RB Series Regulating System

CP200 Series Commercial / Industrial Pressure- Loaded Pressure Reducing Regulator

Type CT88 Backpressure Regulator

Prop. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08

TECHNICAL DATA ANTI-FLOOD DEVICE MODEL B-1 1. DESCRIPTION

Relief Valves. Relief Valves. International, Inc. Company ACIRCOR. RS Differential NB 9.5mm. RVA In-line Differential NB 6 to 19mm

Series 4 Cv= Air-Pilot operated valves. 3-way/2-position, 5-way/2-position, 5-way/3-position

R133 HELYON. Brass high pressure regulator, suitable for compressed air, gas and liquid

HIGH-PRESSURE RELIEF VALVES

Instruction Manual Updated 7/26/2011 Ver. 2.2

DAV Series. DAV-MH Air Release & Vacuum Break Valves

Combination Air Valve Model

Proportional Pressure-Relief Cartridge Valve, Size 2...4

PARTS, SERVICE & REPAIR BULLETIN

Inverse Proportional Pressure-Relief Cart., Size 2 4

CSA Sample Draw Aspirator Adapter Operator s Manual

Types 627W and 627WH Direct-Operated Pressure Reducing Liquid Regulators

3-Way Pressure-Reducing Cartridge, Size 2 4

VAREC 180 SERIES PRESSURE REGULATORS

Mark 958 Series (3/4" - 1") Sanitary Gas Back Pressure Regulators

Flow Sensors & Hydrometers Specification Sheet

RELIEF VALVES. V Series. Process Management TM. Type V/20-2. Type V/50. Type V/60

Combination Air Valve

1200B2 Series Service Regulators. Instruction Manual

Type 92S Pilot-Operated Steam Regulator

2.0 INSTALLATION & SERVICE

Inverse Proportional Pressure-Relief Cartridge, Size 10

JR Series. Gas Pressure Reducing Valve GAS PRESSURE REDUCING VALVE

TONS! powerteam.com HEAVY LIFT CYLINDERS

630 Series Regulators and Relief Valves

DPC-30 DPC-100. Reference Manual

SIX R (P ) AND SEVEN R (P ) POSITION CYLINDERS Service Information

Standard Specifications

Y692VB Series Vacuum Breaker

V248 Series 3-Way Pressure-Actuated. Water-Regulating Valves for High-Pressure

Model Series 62 Constant Differential Relay

lternative odels 3.87 (98) anual Drain 2.67 (68) 3.72 (94) utomatic Drain 2.13 (54) 1.12 (28) P1H, PTH Filter/Regulator-Lubricator Combination Units 0

Double Pilot Operated Cartridge Check Valve, Size 8

North American Pressure Switches

Blanketing Valve ZM-R. low pressure reducing valve

Bermad Pressure Reducing. Model: 42T

Inverse Proportional Pressure-Relief Cart., Size 2 4

BACK PRESSURE / SUSTAINING

GM-7000 Series CE Approved Gas Control Valve

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified

BACK PRESSURE / SUSTAINING

North American 7339 High Pressure Gas Regulators

ALE-32. Miniature General Purpose Regulators R07, R46 (non-repairable) Air line equipment. Technical data

Liquid and gas sample tool

C645A-E Pressure Switches

Transcription:

Low Pressure Valve Model 4047 Overview AMOT Model 4047 is used as a 2-way or 3-way high capacity, low pressure valve for settings from 0.007 bar (0.1) psi falling to 0.77 bar (11.2 psi) rising over several ranges. Applications include sensing low pressure low pressure gas, water, fuel, oil, or for liquid level sensing and control. By piping to the vacuum port, the valve can be used to sense vacuum pressure from 0.007 bar (0.1) psi falling. The 4047 can detect overload on gas engines by sensing the vacuum pressure in the intake manifold. Typical applications Sense low pressure or vacuum of water, air, natural gas, oil and more Detection of overload on gas engines Sensing of vacuum intake air manifold Key features and benefits 3-way valve has balanced force design Pressure can be applied at any port Buna N (Nitrile) tadpole seals are easily replaced Bubble-tight seals with center dead spot (no port overlap) Gulfproof finish standard www.amot.com

Operation 2-WAY Valve to open on rising pressure Port 1 must be plugged. Rising pressure will open Port 2 to Port 3 above the trip point. Valve to open on falling pressure Port 3 must be plugged. Falling pressure will open Port 2 to Port 1 below the set trip point. 3-WAY Valve operation for 3-way action is identical with that for 2-way except that there will be no plugged ports. On valves set to trip on rising pressure, Port 1 will open to Port 2 until just below the trip point. Port 3 will open to Port 2 at the trip point. On falling pressure, Port 3 will close first. Then Port 1 will open to Port 2. AMOT Model 4047 has a dead spot in the exact center position, which prevents the overlapping of Ports 1 and 3. Because of this, Ports 1 and 3 will not open and close simultaneously at the trip point. Specification Valve body and diaphragm housing Valve spool Standard seals and diaphragm Gulfproofed (anodized) aluminum Glass reinforced Ryton Buna N (Nitrile) Maximum operating pressures at Ports 1, 2 and 3 8.6 bar (125 psi) Maximum continuous control pressure at diaphragm 1.4 bar (20 psi) Proof pressure - diaphragm 2.1 bar (30 psi) Maximum Temperature 66 C (150 F) Valve free flow area (9/32 diameter port) Kv = 1.0 Cv = 1.2 Net weight 2.3 kg (5 lbs) page 2

Dimensions Dimensions inches (mm) How to order Use the tables below to select the unique specification of your 4047 Low Pressure Valve: Example: 4047B A B C D - EE A Pressure Range C Reset Type 1 Tripping Pressure Range in bar (psi) Rising 0.028-0.09 (0.4-1.3) Falling 0.0069-0.069 (0.1-1.0) Reset Differential 0.014-0.021 (0.2-0.3) 0 Automatic Reset 1 Manual Reset (falling pressure) 2 Manual Reset (rising pressure) 2 3 0.055-0.48 (0.8-7.0) 0.17-0.77 (2.5-11.2) 0.028-0.43 (0.4-6.2) 0.14-0.69 (2.0-10.0) 0.028-0.055 (0.4-0.8) 0.034-0.083 (0.5-1.2) D A B Seal Material Buna N (Nitrile) Viton B Thread and Finish 2 NPT Thread, Gulfproof (Anodized) Finish EE AA Special Requirements Standard Special requirements made to order. Contact Factory for order code. page 3

Maintenance Properly applied and installed, Model 4047 requires minimal maintenance. Unless leakage or other problems are noticed sooner, an inspection of the units at yearly intervals is adequate to detect and make provision for normal wear and preventative maintenance. It is recommended that the valve be checked monthly if possible for proper functioning by simulating an unsafe condition. Service kits STAMP "P" STAMP "V" 8 10 15 2 3 1 31 29 21 Service Kit No. 9169X001 - Buna N Ref Qty Description 8 1 O-ring 10 1 Diaphragm 12 2 Seal 15 1 O-ring 21 1 O-ring 31 4 Seal ring Service Kit No. 9169X002 - Viton Ref Qty Description 8 1 O-ring 10 1 Diaphragm 12 2 Seal 15 1 O-ring 21 1 O-ring 31 4 Seal ring page 4

Americas AMOT USA 8824 Fallbrook Dr Houston TX 77064 USA Tel: +1 (281) 940 1800 Fax +1 (713) 559 9419 Email sales@amotusa.com Europe, Middle East, Africa AMOT Western Way Bury St Edmunds Suffolk, IP33 3SZ England Tel +44 (0) 1284 762222 Fax +44 (0) 1284 760256 Email info@amot.com Asia Pacific AMOT Shanghai Rm 4102-4104 United Plaza 1468 Nanjing Road West Shanghai 200040 China Tel +86 (0) 21 6279 7700 Fax +86 (0) 21 5237 8560 Email shanghai@amot.com AMOT Controls GmbH Rondenbarg 25 22525 Hamburg Germany Tel +49 (0) 40 8537 1298 Fax +49 (0) 40 8537 1331 Email germany@amot.com AMOT Singapore 10 Eunos Road 8 #12-06 Singapore Post Centre Singapore 408600 Tel +65 6408 6265 Fax +65 6293 3307 Email singapore@amot.com www.amot.com