CompacSas BA. Comfort and design for high-security access

Similar documents
The CompacSas BAH airlock is the ideal solution for transforming an existing door into an airlock

The elegant solution for enhanced security. Manual Attack Resistance. Ballistic Resistance. Recyclable product. Eco-design. exit

UniSas BA. Physical single-person detection. Models: UniSas BA9, UniSas BA12. Energy savings. Eco-design. Recyclable product. Manual Attack Resistance

SECURITY AIRLOCK SOLUTIONS

EasySas. The most advanced airlock electronics on the market. Recyclable product. Eco-design. Energy savings

BUBBLER CONTROL SYSTEM

BUBBLER CONTROL SYSTEM

10.2. Basketball Single Post System

Order No Projection Backboard

INDUSTRIAL HOSE REEL suitable also for out-door workplaces. Made in Italy

JOLLY2. Installation user s manual. 6 different operating modes selectable. version 3.3. DATA TO BE FILLED OUT BY THE INSTALLER (Page 1)

Insulated Door Components. Tension Spring System. High performance hardware door system for residential applications

10.2. Basketball Single Post System

K13.12 FACE FIXED PANIC EXIT DEVICE K13 DOORS

INSTRUCTION MANUAL Pressure Relief Device LPT

CR Series. Special doors for clean room application

Fire- & smoke- tight sliding door FST High quality for demanding architecture

ARCA cabinet NEW. High performance polycarbonate cabinet. Protection in demanding environments

GV Standard X-Vent. Setup, Commissioning & Installation Guide

MEGAS 2.0. Gas analysis with direct C-Level Calculation and Bus-Connection. Data sheet

Gas Cylinder Cabinets

home mobility design comfort HOME SOLUTIONS

Pneumatic Target Transfer System Model PT01

TB 42. Low maintenance effort saves on time and costs. High variability for vehicle types, construction and expan- sion options

The Univentor 1250 Anaesthesia Unit

Pneumatic high-pressure controller Model CPC7000

3M InCa Individual Cross-Connection Cabinets

ELEGANT AND SECURE MODERN BICYCLE PARKING SYSTEMS

Instruction Manual BA90 Precision Barometer

enclosures to ATEX and enclosures for special custom design (EEx p and NEMA cabinets)

LK-SX VOC. Application. Security Advice Caution. Notes on Disposal. Combined sensor mixed gas. Data sheet

Manifolds & pressure reducing sets

Pneumatic high-pressure controller Model CPC7000

DIRECTIONS FOR USE / ASSEMBLING

TECHNICAL DESCRIPTION

New AQF Filter Polymer Filtration System

LK-SX CO 2 +VOC. Application. Security Advice Caution. Notes on Disposal

COMPANY PROFILE. Sales to 90 countries worldwide

BFT Bollards. A complete range of bollards

High-speed pressure sensor Model CPT6140

DIRECTIONS FOR USE / ASSEMBLING

enclosures to ATEX and enclosures for special custom design (EEx p and NEMA cabinets)

Plasma. Argon Production Helium Liquefaction Truck Loading Pure Gas Bottling

MEDIANA HEARTON AED A15. Mediana Automated External Defibrillator A15

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE

MONOPLACE HYPERBARIC CHAMBER FOR DIVERS TRANSPORT MODEL OXICAB MO-BZ-TR TECHNICAL OFFER

EX-RECESSED CEILING LIGHT FITTINGS

FLOW CONDITIONER «EMIS-VEKTA 1200» EMIS-VEKTA 1200.UM.PS v User manual Passport. «EMIS», CJSC Russia, Chelyabinsk

Operating Instructions Part No

Data Distribution Cabinets. Exclusive CD edition March 2006

Panther 5 Acute Care Ventilator

Drying ovens FD series Drying ovens with forced convection Leistungsmerkmale/Ausstattung:

Data Sheet VELUX INTEGRA Roller Blind

CONSOLE-320 ENGLISH. 230A: CONSOLE-320 with cable data output Item 230B: CONSOLE-320 with cable + wireless radio data output

CNG FILLING STATIONS

ski racks DESCRIPTION ADULT SKI RACK DIMENSIONS

Trim and Stabilisation systems NEXT GENERATION IN BOAT CONTROL.

WELCOME TO THE REVOLUTION

Versatile, user friendly all glass sliding revolving door w26-c Maintenance Instructions and Directions for Use

Adjustable swirl diffuser ODZA TECHNICAL DATA

CFSW. Hinges with built-in safety multiple switch

Operation manual Level sensor DC-LS-50 Operation Manual Level Sensor DC-LS-50

OEM Manual MODEL 2305 ECONOMICAL DIGITAL SINGLE CYLINDER SCALE

MOBILAIR M 235. Portable Compressor With the world-renowned SIGMA PROFILE Flow rate 18.1 to 23.3 m³/min ( cfm)

Surge suppressor To perform its intended functions, an AEI site must have the components listed above and shown in Fig. 4.1.

Poollift Delphin. Version: February, 2015 MANUAL AND OPERATING INSTRUCTIONS

FTC130 Transmitter. Operating Manual

OPERATING INSTRUCTIONS MANUAL FOR QACV PNEUMATIC DOSING PUMP

Kestrel Aluminium Systems Limited. Product Manual Section 10 Thermal Framing System. Manual Version

What hull material types will the system work on? Do I still need an antifoul paint?

Locator Locator-D-Lux Air-Saver G1 Air-Saver G2

Pressure switch Type BCP

Price List January SECUROPE Life Line

SonoMeter 30 Energy Meters

AutoChanger Installation & User Guide Issue 2

Uniflair LE TDAR-TUAR

POP Product Guide. [Type text]

Digital Pressure Gauge Main features: Data Sheet: DFP.418.R4.EN

CLOVER CLOVER. clover. Copyrights and patents Lappset Group Ltd

RPS900W Redundant Power Supply. Installation Guide.

CONDUCTIVITY POINT/S LEVEL SWITCH JAYCEEAQUA 4000 SERIES

Models EXN and OLG. General Description. Features and Benefits. Pressurizer for Vertical Air Conditioners Increased Safety for Hazardous Locations

User Manual PTW-DensiX. D / Di/Zi

Name of product: Gripper for vertical façade FTV panels Types: PVF (60, 80, 100, 120, 133, 150, 172, 200 and 240 mm) INSTRUCTIONS FOR USE

DETAILS. Finishing: metal frame: epoxy powder coating RAL 7016 dark-grey or RAL 9006 silver-grey rails-clamps-wheels-bolts: galvanised material

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

MODERNISATION SOLUTIONS

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

CFSW. Hinges with built-in safety multiple switch

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

Product information VELUX INTEGRA centre-pivot pine roof window GGL

DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES

Tel:

Vibration isolated tables. Individually tailored to your requirements.

INSTRUCTION MANUAL. Vertical sliding window. Product: Sliding window Version: 0.1e Language: English Original language: German Document: SF0001

Sorensen DCS Series. 1 3 kw V A. General Purpose Systems Power Supply

F13.11 PARALLEL HINGES F13 PROJECT-OUT WINDOWS AND TOP HUNG WINDOWS

Electro-Pneumatic Converter YT-940 SERIES

H11.13 PIVOTS SERIES 490 H11 HORIZONTAL AND VERTICAL PIVOT WINDOWS

AGW SYSTEMS. Blue Clock W38X

Transcription:

CompacSas BA Comfort and design for high-security access Manual Attack Resistance Ballistic Resistance Access Flow Recyclable product Eco-design Models: CompacSas BA6Q, CompacSas BA6, CompacSas BA9 CompacSas BA is also known under HiSec name

Comfort and design The CompacSas BA airlock is a single-unit airlock with curved, motorised sliding doors, allowing ease of passage for users With its shape and glass surface, the CompacSas BA harmoniously integrates into all types of industrial and service sector environments. There is a choice of presence-detection, singleperson detection, metal and abandoned-object detection equipment in order to determine the required security level. Benefits 1. Single-piece airlock with aesthetic curved forms. 2. Automatic sliding doors. 3. Metal detection. The CompacSas BA is available in different versions, depending on the level of resistance required: vandalism, manual attack and bullet resistance. The CompacSas BA optimises installation and commissioning.

Design Construction Steel structure and ceiling. Composite material sliding door. Laminated glass security panel. Opening system Standard opening by fail-secure motor for the CompacSas BA6 or fail safe motor for the CompacSas BA9. Finish Powder coated paint. Colour Black RAL 9005 Grey RAL 7001 Blue RAL 5010 Brown RAL 8019 Red RAL 3003 Other RAL colours Granite finish Smooth finish Metallic finish Stainless steel granite finish Brushed stainless steel finish Resistance level Vandalism resistance (EN 356) Manual attack resistance (EN 356) Ballistic resistance (EN 1063) Ballistic resistance (EN 1063) P2A BR3-S P7B BR4-NS Structure Operation In standby mode, both doors are closed and locked. During usage, a door can only open if the other door is closed and locked. Entry Once an opening request has been received, the outer door opens. The weighing detection system checks to see if anyone is present inside the airlock and that only one person is currently using it. Once these checks have been carried out, the outer door closes and the inner door opens. The user exits the airlock. The door closes and locks once the user has exited. Exit Identical procedure to entry. Control and Detection Opening requests can be issued by commands from call buttons, detection equipment (radar) and/or access control equipment (card readers, biometrics...). Use of the airlock is rendered secure by presence detection equipment which is used in conjunction with single-person detection equipment. A metal detection system which is integrated into the outer door and used in conjunction with an abandoned object detection system maximises the quality of filtering for people entering into the airlock. Opening request Push button Weighing within the cabin Card reader (not supplied) Radar Detection system Presence Single person detection Abandoned objects Metal Weighing 2-zone contact mat Metal Detection Standard Optional Not available

Detection by weighing If weighing control is carried out by the airlock, access is refused if a threshold of between 120 kg (standard) and 255 kg (maximum) is exceeded. If weighing control is carried out by an access control system, the airlock can send it the weight it has measured: either using 4 relays which generate 16 weight ranges increasing in increments of 5 kg or via an RS232 serial connection in ASCII format 1. 1. The access control system compares the value of the weight measured by the airlock with a reference weight in its database for the user s card. User Safety For emergency situations, the site should have a separate fire exit door/route. In the event of a power failure, the airlock can be operated by a battery backup for up to 2 hours (depending on usage). People using automatic doors are protected by inflated safety edges and by the force of the motor being checked. Optional Equipment Metal detection Radar Intercom Voice synthesizer Box service program with hardware key and cable Mechanical lock Inner airlock mounting post Inner break glass unit 2-zone contact mat Safety buffer for compliance with the EN 12650 Solid fixed side panels Glass fitted with black/obscure film Technical data Structural opening H+10mm, W+10mm Floor Floor to be recessed 70mm Floor level +/ 5mm External Facade installation No 1 Airlock delivery Assembled 2 Panel delivery Assembled Maintenance accessibility 500mm clear above Power supply 3 230Vac, 50Hz Operating voltage 24Vdc Consumption 250W Ambient temperature 15 C/+40 C Relative humidity <90% with no condensation Cable routing From top or the floor Control unit + motor located Into the ceiling 1. Semi-exterior installation under specific conditions may be possible. Consult Gunnebo. 2. Optional delivery dismantled for circular versions only. 3. Power supply provided by the client with protection system in compliance with regulations (10A/30mA).

Functional Data and Dimensions Flow Disability access Emergency exit 4 people/minute No No Dimensions (mm) W Overall Width PW Passage Width H Overall Height PH Passage Height D Depth Weight (Kg) CompacSas BA6Q 1032 600 2400 2200 1032 710 CompacSas BA6 1042 600 2400 2200 1042 850 CompacSas BA9 1500 900 2400 2200 1500 1115

Design and production: Gunnebo. Photos Credits: Gunnebo and Fotolia. The data given in this material may be subject to change without further notice. The Gunnebo logos and Gunnebo For a safer world are registered trademarks of Gunnebo AB. See www.gunnebo.com for more information. GUGB.9053.R1