.... AC drive to. 7.5 kw... 1 HP to 10 HP...

Similar documents
Applications. What moves your world

THE WORLD COMPETITIVENESS SCOREBOARD 2011

AREA TOTALS OECD Composite Leading Indicators. OECD Total. OECD + Major 6 Non Member Countries. Major Five Asia. Major Seven.

Upgrading Bio-Plex Manager 4.1, 5.0, or 6.0 Software to Bio-Plex Manager 6.1 Software

Remote Control VP04 Pneumatic Proportional Remote Control Valve zrc02. Catalogue HY /UK December, 2004

HydroCOM: High energy savings and excellent controllability

VLT 2000 Series. How to size your VLT

Max Sort Sortation Option - Letters

SonoMeter 30 Energy Meters

LIST OF BILATERAL AIR SERVICES AGREEMENT (BASA)/MEMORANDUM OF UNDERSTANDING (MOU) SIGNED AND/OR INITIALED BY THE REPUBLIC OF MAURITIUS

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

Organizing Entity Host City Start Date End Date Remarks Held in New York 04 December December 2017 Confirmed

FACT Sheet. FIFA Competition winners at a glance. Men s Competitions. FIFA World Cup (staged every four years)

SCH-27. Diaphragm Pressure Switch. Setting range: mbar to bar. Temperature: max C. Material: stainless steel

e2c 20 - easy to connect

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

WATO EX-35 Anaesthesia Machine. exceptional performance

Optimization of a Proven Technology

WAGO-I/O-SYSTEM 750 XTR Taking it to the extreme The Standard for 750 XTR

Mass Flow Meter (MFM) for gases

Global Construction Outlook: Laura Hanlon Product Manager, Global Construction Outlook May 21, 2009

TERMINAL BLOCK SUMMARY

A4 Operation Manual. Fig.1-1 Controller Socket Diagram

Firearms & parts firearms & parts firearms & parts rocket launcher components

Model 601CV. Mass Flow Controller. Product Features:

A4s Operation Manual

CO, NO, NO 2, NO x, SO 2, CH 4, HCl, CO 2 & H ² O. Extractive low cost, low maintenance devices for continuous process and emissions monitoring.

CP3R Quick Start Manual

I N T E R N A T I O N A L S K A T I N G U N I O N

CPN1 Quick Start Manual

I N T E R N A T I O N A L S K A T I N G U N I O N

INTERNATIONAL SKATING UNION

KMT. Thermal Mass Flow Meter. for Compressed Air and Gases. Measuring range: m3n/h m3 N

FACT Sheet. FIFA Competition winners at a glance. FIFA Men s Competitions. FIFA World Cup (staged every four years)

AHE58/59 AC Servo System

BUBBLER CONTROL SYSTEM

LT GasAnalyzer. LT GasAnalyzer Page 1 of 6

Demography Series: China

Invitation to. The 36th World Amateur Go Championship in Bangkok. Outline

CHAdeMO certification tests at IDIADA HQ in Europe

WATO EX-65 NEW. the enhanced anaesthesia workstation

Visualize Nitrogen Gas Consumption

LOCAL BROADCASTER DUBAI DUBAI SPORTS CHANNEL 01-Nov-13 01:00 02:00 Hlts Day 1 01:00 EUROPE DURATION HH:MM

OSAT Series. Intrinsically Safe Infrared Temperature Sensor Operator's Guide

Auxiliary Valve PRS6 Pressure Reducing Valve. Catalogue HY /UK June 2003

Differential Probes TDP1500 and TDP3500 Datasheet

User Guide for the Sterile Cord Blood Collection Unit

Design Envelope Booster. Sequence of operation

E2B PROXIMITY SENSORS

P9000 DESCRIPTION. For parts requiring RoHS compliance, please contact factory. P February /6

German Machine Tool Industry - Key Figures

Value Exported (CDN$) Support Systems ,165 firearms ,389 firearms ,465 firearms ,500 rocket launchers

SG33KTL-M Quick Installation Guide. 1 Unpacking and Inspection

Confidence through experience. Track record as of 30 June 2012

Mass Flow Controller (MFC) for Gases

3.0 Pressure Transmitter Selection

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter

2017 City RepTrak. The Most Reputable Cities in the World. September 28th, 2017 Nicolas G. Trad

FLAMMABLE GAS SENSOR/TRANSMITTER

Update of trade weights data underlying the EERs and HCIs

Quick Installation Guide Doc nr.: C Date:

Auxiliary Valve QDS6 Sequence Valve, 3-way. Catalogue HY /UK June 2003

I. World trade in Overview

combustion efficiency monitoring General Purpose Applications Flue gas oxygen analyzers Combustion & Environmental Monitoring An Company

Gas density monitor With integrated transmitter Model GDM-100-TI

Navigator 500 Dissolved oxygen analyzer. Measurement made easy. Accurate and reliable measurement of dissolved oxygen in high purity water

KMT. Thermal Mass Flowmeter. for compressed air and gases. Measuring range: Nm³/h Nm³/h

Desalination From theory to practice People, Papers, Publications. Miriam Balaban EDS Secretary General

Ultra High Purity Model 780S

KA001A/05/e/ t-switch ATT11. Flow Limit Switch for Liquids and Gases

11 November 2016, Nyon, Switzerland. 2016/17 UEFA European Women s Under-17 and Women s Under-19 Championships. Elite round draws

SG36KTL-M Quick Installation Guide. 1 Unpacking and Inspection

SCOPE OF THIS GUIDE STARTING-UP. 1 Check mini CORI-FLOW functional properties

RS 2-75 D 109 D RSF 87 D 127 D with direct drive

The 11th Korea Prime Minister Cup International Amateur Baduk Championship

Mass Flow Controller (MFC) for Gases

BA307C & BA308C Intrinsically safe loop-powered 3½ digit panel mounting indicators issue 9

OEM Manual. MODEL ½ Digit DRUM SCALE

Water Flow Regulators. The Leading Water Flow Regulator Worldwide. Essential Equipment For every injection and blow molding machine

Aquamantys System Generator Verification

The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions

Hand-held pressure calibrator with integrated pump Model CPH6600

2015/16 UEFA European Women s Under-17 and Women s Under-19 Championships Elite round draws

Portuguese, English, and. Bulgarian, English, French, or

2007 International Skills Festival estimates 3,452 participants from 63 countries/regions in accreditation

TAKING IT TO THE EXTREME The WAGO-I/O-SYSTEM for extreme Applications

heading no (excluding horsehair)

FIL Qualifying Event Proposal. Problem Statement. Proposal for voting at GA

New rules, new opportunities: a potential for growth

High Pressure Breathing Air Compressors

METROTEC GSM. Type GSM. Oxygen measurement and control unit. *** Version 1.6 ***

SPEEDY SERVICES WALES SENIOR OPEN June 2013 TELEVISION DISTRIBUTION LIST (as at 13th June 2013)

Efficient EMC Solutions

combustion efficiency monitoring Flue gas oxygen analyzers General Purpose Applications Combustion & Environmental Monitoring

Post Show Report April 2015, Moscow, Russia. #ipheb

Malema Sensors M-2700 Integrated Ultrasonic Flow Meter

DANAGE TIMER System Controller User Manual

Roller AC Servo System

ABB MEASUREMENT & ANALYTICS DATA SHEET. WaterMaster FEW530 Electromagnetic water meter

RS D RSF D with direct drive

Transcription:

Commander SX IP66, Nema 4X AC drive 075 to 75 kw 1 HP to 10 HP

Commander SX - for tough environments 10V ADI1 0V ADI2 0V AIO3 DIO1 +24V DI2 DI3 +24V DI4 SDI1 SDI2 COM RL1O RL1C SDO1 SDO2 0-10V analog reference 4-20mA analog reference 0-10V motor speed analog output Zero speed output Run forward/stop Run reverse/stop Reference select Enable input Output relay - Drive healthy Output relay - Drive disabled From 075 to 75 kw the Commander SX has been designed as a robust, IP66 wall mounting AC drive for applications in food, drink, paper, textile and packaging machines where dirt, dust and other pollutants need to be regularly washed away Why Commander SX? IP66 Nema 4x enclosed drive - no need for separate enclosure Designed for direct to wall or next-to-motor mounting - avoiding cabling, cabinet and installation costs Easy setup and commissioning - the first 10 parameters cover 80% of applications 8 preset drive configurations Surface and corners designed to maximise washdown effectiveness Internally fitted EMC filter (to generic and drive standard) for units up to 4 kw - IP65 EMC filters 4 kw, from 55 kw as option Robust industrial housing with simple speed control interface - no drive installation specialists required IP66 Nema 4X For tough environments Designed for factory washdown with pressure hose Wall mounting - no extra cubicles required Integrated braking IGBT and resistor Heavy duty optional IP66 resistors also available Automatic autotune For fast reliable set up Encoder option Internally fitted encoder option for incremental encoders up to 32,000 lines per revolution

Commander SX design features Keyhole mounting slots For easy wall fixing LCD text keypad For parameter set up and commissioning Bright backlit for clarity Online help functions Dual language Optional Brake module For motor mechanical brake release - internally fitted

General Characteristics Advanced set up and commissioning with CTSoft Windows based commissioning software for both control and display of all parameters Special drive set up wizard for first time users Storage of parameter settings Access to advanced parameters Onboard EMC filter For units up to 4 kw Meets both generic and drive EMC standards Optional EMC filter From 55 kw rated to IP65 For long motor cable lengths Removable gland plate World class fieldbus flexibility Modbus RTU (as standard) For rapid commissioning and easy maintenance Environment IP66 Nema 4X rating Ambient temperature 40 ºC without derating Up to 50 ºC operation with a maximum derating of only one motor size Removable gland plate for easy termination and removal of control and motor cables EMC cable glands for shielded cable management Electromagnetic Immunity complies with EN61800-3 (Drive standard) and EN50082-2 Electromagnetic Emissions complies with EN61800-3 (Drive standard - first and second environment) with EMC filter Complies with EN50081-1 and EN50081-2 (Generic standard) with EMC filter Complies with EN50081-2 with integrated EMC filter Earth leakage current less than 3 ma with integral EMC filter in circuit Ergonomically designed surfaces to aid dirt removal during wash down - - Slopes greater than 3º from horizontal - Radii above 6 mm Control Open loop vector control V/F control Closed loop vector (option) Speed reference input 0-10 V, 0-20 ma, 4-20 ma 5 digital input Enable, Run forward, Run reverse, Jog, local / remote select Switching frequency 3-11 khz with 4 khz as default Acceleration and Deceleration ramps (linear and S-type) Serial communication as standard - Modbus RTU RS485 via RJ45 connector DC injection braking as standard Integral dynamic braking transistor and resistor PID Controller Protection Undervoltage, Supply and DC Link overvoltage, Phase loss, Drive overload, Instantaneous overcurrent, Over temp, Short circuit, Ground fault, Over heat, Motor thermal, Watchdog

technical data Commander SX rating and EMC filter selection Model order code Supply volts ±10% Commander SX No of input phases Frame size kw rating HP rating 100% Output current 150% Mounting Overload style current for 60s SX13400075 380-480 3 1 075 1 21 32 SX13400110 380-480 3 1 11 15 3 45 SX13400150 380-480 3 1 15 2 42 63 SX23400220 380-480 3 2 22 3 58 87 Integral EMC filter as standard SX23400300 380-480 3 2 3 4 76 114 SX23400400 380-480 3 2 4 5 95 143 SX33400550 380-480 3 3 55 75 13 195 IP65 20 TBA 130 175 40 SX33400750 380-480 3 3 75 10 165 248 Bookcase Motor Cable Industrial (m) EMC Filter CT order code D (mm) * Rated current at 4kHz (default) switching frequency Higher switching frequencies are available with some derating Commander SX 2 3 4 00075 H (mm) W (mm) frame size family name kw rating Voltage (400 V) 3 phase input COMMANDER SX A Dimensions Frame Size 1 2 3 B A B C mm in mm in mm in 330 1299 175 689 170 669 330 1299 175 689 200 787 330 1299 250 984 210 827 C Options Part No SX-Keypad Plus CT Soft CT Comms Cable SM-PROFIBUS-DP SM-DeviceNet SM-INTERBUS SM-CANopen SM-CAN SX-Encoder SX-Brake Resistors Description LCD text keypad PC Windows based setup software For CTSoft between PC and Drive Profibus DP-12 MB DeviceNet fieldbus interface Interbus fieldbus interface CANOpen fieldbus interface CANbus fieldbus interface Incremental encoder feedback module Motor mechanical brake controller Braking resistor available to match duty

driving the world Control Techniques Drive & Application Centres Drive & Application Centres Distributors AUSTRALIA Melbourne Application Centre ACN 003 815 281 Tel: 61 973 81777 Fax: 61 9729 3200 After Hours: 61 2 9963 5271 Sydney Drive Centre ACN 003 815 281 Tel: 61 2 9838 7222 Fax: 61 2 9838 7764 After Hours: 61 2 9963 5271 AUSTRIA Linz Drive Centre Tel: 43 7229 789480 Fax: 43 7229 7894810 After Hours: 43 7215 3502 BELGIUM Brussels Drive Centre Tel: 32 2725 2721 Fax: 32 2725 4940 CANADA Toronto Drive Centre Tel: 1 905 475 4699 Fax: 1 905 475 4694 CHINA Shanghai Drive Centre Tel: 86 21 5426 0668 Fax: 86 21 5426 0669 Beijing Application Centre Tel: 86 10 6592 5321 ext 20 Fax: 86 10 6500 3094 CZECH REPUBLIC Brno Drive Centre Tel: 420 541 192111 Fax: 420 541 192115 After Hours: 420 541 192 119 DENMARK Copenhagen Drive Centre Tel: 45 4369 6100 Fax: 45 4369 6101 After Hours: 45 4369 6100 FINLAND Helsinki Drive Centre Tel: 358 985 2661 Fax: 358 985 26823 After Hours: 358 500 423271 FRANCE Leroy Somer Angouleme Drive Centre Tel: 33 5 4564 5454 Fax: 33 5 4564 5400 GERMANY Bonn Drive Centre Tel: 49 2242 8770 Fax: 49 2242 877277 Chemnitz Drive Centre Tel: 49 3722 52030 Fax: 49 3722 520330 Darmstadt Drive Centre Tel: 49 6251 17700 Fax: 49 6251 177098 Stuttgart Drive Centre Tel: 49 7156 95560 Fax: 49 7156 955698 HOLLAND Rotterdam Drive Centre Tel: 31 1844 20555 Fax: 31 1844 20721 After Hours: 31 1844 20555 HONG KONG Hong Kong Application Centre Tel: 852 2979 5271 Fax: 852 2979 5220 HUNGARY Budapest Drive Centre Tel: 361 431 1160 Fax: 361 260 5483 After Hours: 36 309 77 2663 INDIA Mumbai Application Centre Tel: 91 20 613 1954 Fax: 91 20 612 3771 Kolkata Application Centre Tel: 91 33 357 5302/357 5306 Fax: 91 33 357 3435 After Hours: 91 33 358 3622 Chennai Drive Centre Tel: 91 44 4961123/4961130/4961083 Fax: 91 44 4961602 After Hours: 91 44 496 1083 New Delhi Application Centre Tel: 91 11 576 4782 Fax: 91 11 576 4782 INDONESIA Jakarta Drive Centre Tel: 62 21 4525146 Fax: 62 21 4525142 After Hours: 62 81 687 0443 Surabaya Application Centre Tel: 62 31 7347881/7347882 Fax: 62 31 7347883 After Hours: 62 81 687 0443 IRELAND Dublin Drive Centre Tel: 353 45 433044 Fax: 353 45 433622 ITALY Milan Drive Centre Tel: 39 02575 751 Fax: 39 02575 12858 After Hours: 39 02575 751 Vicenza Drive Centre Tel: 39 0444 396200 Fax: 39 0444 341317 KOREA Seoul Application Centre Tel: 82 2 557 7374 Fax: 82 2 557 7301 After Hours: 82 2 557 7374 MALAYSIA Kuala Lumpur Drive Centre Tel: 60 5634 9776 Fax: 60 5633 9592 After Hours: 60 12 333 8355 NORWAY Oslo Application Centre Tel: 47 32 235100 Fax: 47 32 235101 After Hours: 47 92 22 3292 REPUBLIC OF SOUTH AFRICA Johannesburg Drive Centre Tel: 27 11 462 1740 Fax: 27 11 462 1941 After Hours: 27 11 462 1740 RUSSIA Moscow Application Centre Tel: 7 095 232 9472 Fax: 7 095 956 4862 SINGAPORE Singapore Drive Centre Tel: 65 271 6377 Fax: 65 272 1302 After Hours: 65 9752 5828 SPAIN Barcelona Drive Centre Tel: 34 93 680 1661 Fax: 34 93 680 0903 /34 93 680 2823 After Hours: 34 610 554540 Bilbao Application Centre Tel: 34 94 620 3646 Fax: 34 94 681 1406 Valencia Drive Centre Tel: 34 96 154 2900 Fax: 34 96 153 2906 SWEDEN Stockholm Application Centre Tel: 46 8 554 24100 Fax: 46 8 554 24120 SWITZERLAND Lausanne Application Centre Tel: 41 21 637 7070 Fax: 41 21 637 7071 Zurich Drive Centre Tel: 41 56 201 4242 Fax: 41 56 201 4243 After Hours: 41 79 357 8683 TAIWAN Taipei Application Centre Tel: 886 22325 9555 Fax: 886 22705 9131 THAILAND Bangkok Drive Centre Tel: 66 2580 7644 Fax: 66 2591 4559 A/Hours Sales: 66 1443 4095 A/Hours Service: 66 1443 4098 TURKEY Istanbul Drive Centre Tel: 90 216 4182420 Fax: 90 216 4182423 After Hours: 90 216 418 2420 UNITED KINGDOM Telford Drive Centre Tel: 44 1952 213700 Fax: 44 1952 213701 After Hours: 44 1952 213700 USA Charlotte Application Centre Tel: 1 704 393 3366 Fax: 1 704 393 0900 Chicago Application Centre Tel: 1 630 752 5249 Fax: 1 630 752 4156 Cleveland Drive Centre Tel: 1 440 717 0123 Fax: 1 440 717 0133 Minneapolis US Headquarters Tel: 1 952 995 8000 Fax: 1 952 995 8020 Providence Drive Centre Tel: 1 401 333 3331 Fax: 1 401 333 6330 VIETNAM Ho Chi Minh Application Centre Tel: 84 8 842 5157 /84 8 849 1980 Fax: 84 8 8425157 Control Techniques 1999 The information contained in this brochure is for guidance only and does not form part of any contract The accuracy cannot be guaranteed as Control Techniques have an ongoing process of development and reserve the right to change the specification of their products without notice Part No 0175-0324 04/03