IMPACT. Uni-Vent. Eagle. Model 754 Portable Ventilator

Similar documents
O-Two Self-Study Guide. e600 Transport Ventilator Ventilation Modes

Apollo Safety Features

AUTOVENT 4000 VENTILATOR


NEONATAL/INFANT VENTILATOR

Technical Data and Specifications

patient education program 4156 South 52 nd Street, Omaha, NE ChildrensOmaha.org/HomeHealthcare

A9600 Anesthesia Workstation. Your healthcare, we care.

ASSISTANCE. Cardinal Health Pulmonetic Systems Medina Rd., Suite 100 Minneapolis, Minnesota

GE Healthcare. Centiva/5 Critical Care Ventilator. Meet a new level of expectations

AV-S Ventilator. Service Manual. Partnership for Life. Remote Display Module and Interface for use with A200SP Absorber

Operation and Maintenance of the MCV100 and MCV100-B Portable Ventilator

V8600 Ventilator. Integrated Invasive & Noninvasive Ventilation

SATURN EVO COLOR A N A E S T H E S I A S Y S T E M. Manufacturer of high quality anaesthesia products

Update to RS-232 commands. Changing patient from NIV to INVASIVE Vent Type. SNDF command

NOTE. To enter the Extended Features menu (in normal ventilation mode): Push and hold the Select button for three seconds.

Anesthesia Workstation

Draft Copy July AV-S Ventilator. Partnership for Life. Service Manual. Remote Display Module and Interface for use with A200SP Absorber

Operation of Oxylog 3000 ventilator

PERFORMANCE EVALUATION #34 NAME: 7200 Ventilator Set Up DATE: INSTRUCTOR:

Ventilator Training Module

How Ventilators Work. Chapter 3

AUGUST ANESTHESIA MACHINES MEDICAL PRODUCTS ANESTHESIA MACHINES. Quality System Standard applied: ISO 9001, ISO 13485

Panther 5 Acute Care Ventilator

2015 Hamilton Medical AG. All rights reserved. Printed in Switzerland.

Automatic Transport Ventilator

INTENDED USE CLASSIFICATION PHYSICAL CHARACTERISTICS

Aespire 7100 Essential performance Compact design

AV-S Ventilator User Manual

e700 Automatic Transport Ventilator User Manual e700 User Manual (15PL Rev.14 28_8_2017)

SLE5000 Infant Ventilator with HFO

Milestones of Aeonmed Ventilators

VENTILATION SERVO-s EASY AND RELIABLE PATIENT CARE

DATA SHEET. VENTILATION SERVO-s

SLE4000. Infant Ventilator with touch-screen operation. When the smallest thing matters

e600 Automatic Transport Ventilator User Manual e600 User Manual (15PL Rev.7 28_8_2017)

Operation and Maintenance of the EPV200 Portable Ventilator

AV-S Ventilator User Manual. This manual contains information for software upgrade v

Mass Casualty Ventilator

Servo UNIVERSAL ADVANCED VENTILATION PLATFORM ALL PATIENT CATEGORIES

Classification of Mechanical Ventilators

S/5 Aespire. Quick Reference Guide

IEC C LASSIFICATIONS:

Draeger Fabius GS Pre-Use Check

SLE5000 Neonatal Ventilator with High Frequency Oscillation

e360t and e360t+ Model

Inspiration 7i Ventilator

Patient Setup Information

Anesthesia Solutions. Prima SP and Prima SP2 Anesthesia Systems. The Future of Anesthesia. Partnership for Life

SERVO-s v8.0 Data sheet

Operator s Manual. TBird Series Ventilators

Narkomed MRI-2. A perfect fit for the MRI environment. Because you care. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

The Crossvent 2i+ 2. Ventilator Concept (brief theory of operation and features)

Bunnell LifePulse HFV Quick Reference Guide # Bunnell Incorporated

Use of Strategic National Stockpile [SNS] Ventilators in the Pediatric Patient Instructional Guidelines with Training Scenarios 2 nd Edition (2010)

Airox Supportair Ventilator

PERSEO EVOLUTION. workstation for gaseous anaesthesia. for adults, children and newborns. Code: OM 403 / 3 gas module 3 rotameter

Hospital and Transport for Controlled Breathing

Mechanical Ventilation

Safe Accurate Reliable. CWM-301 Anesthesia System

Meet the changing needs of your patients. Trilogy Series, with advanced ventilator technology

Device overview. 6 Breathing circuit connection. Note: When the remote control foot pedal is connected, the manual switch is disabled.

1 of 9 10/20/2010 4:45 PM

2 OVERVIEW OF VENTILATOR

State-of-the-art anesthesia technology

Siesta i Whispa Integrated technology

FLIGHT MEDICAL INNOVATIONS LTD. FLIGHT 60 Ventilator. Operator's Manual

Introducing Astral. Greater freedom. Confident care. Designed efficiency

Infant Ventilators. Touch-screen Neonatal Ventilator with High Frequency Oscillation SLE5000

Your patients, our primary focus. Siesta i Whispa anesthesia machine

Tafonius. Auxiliary Mode Operating Manual A USERS GUIDE

FLIGHT 60 Ventilator T-edition

Virginia Beach EMS. Oxylator EMX. Debra H. Brennaman, RN, MPA, NREMT-P

Selecting the Ventilator and the Mode. Chapter 6

Completed downloadable Test Bank for Pilbeams Mechanical Ventilation Physiological and Clinical Applications 5th Edition by Cairo

e500 Automatic Transport Ventilator User Manual e500 User Manual (15PL Rev.7 6_6_2017)

Mass Casualty Ventilator Models: MCV100 & MCV100-B

Basics of Mechanical Ventilation. Dr Shrikanth Srinivasan MD,DNB,FNB,EDIC Consultant, Critical Care Medicine Medanta, The Medicity

A few seconds after turning on, the screen changes to Set Up Screen Before adjusting the pressure, calibrate the O 2 sensors

Your patients, our primary focus

Emergency Transport and Ventilation

Operating Instructions for Microprocessor Controlled Ventilators

pneuton Transport Ventilator

... Operator s Manual. Part No. G Rev. D September 2000

INTENSIVE CARE VENTILATORS

QUICK REFERENCE GUIDE

Infant Ventilators. Touch-screen Neonatal Ventilator with High Frequency Oscillation SLE5000

Flight Medical presents the F60

COMPANY PROFILE. Engler manufactures the Sonus V ultrasonic dental unit for the human market

PATIENT SETUP QUICK REFERENCE GUIDE

Automatic Transport Ventilators. ICU Quality Ventilation on the Street.

Expanding versatility. The upgraded Trilogy family of ventilators continues to meet the changing needs of your patients

Aestiva/5. Operation Manual - Part 1. Software Revision 4.X System Controls, Operation, Checkout

evolution 3e Ventilators

Dameca MRI 508. State-of-the-art MRI technology

Tafonius Junior A USERS GUIDE. v10mar2011

HAMILTON-C2 HAMILTON-C2. The universal ventilation solution

VENTILATION SERVO-i INSPIRATION IN EVERY BREATH

New product release. Universal Rebreather Monitor (URBM) Three cell / Independent backup

Infant Ventilators. Infant Ventilator with Touch-Screen Operation SLE4000

Transcription:

IMPACT Uni-Vent Eagle Model 754 Portable Ventilator

Uni-Vent Eagle Model 754 Portable Ventilator OPERATOR TRAINING PROGRAM FOR: Critical Care Transport Aero medicine Emergency Services

Uni-Vent Eagle Model 754 Portable Ventilator Features Microprocessor control of all functions including automatic monitoring of internal battery and external power sources, internal compressor and external gases. Extensive alarm monitoring of operating, non-operating and advisory conditions. Contemporary design to facilitate transport and placement. Gas-efficient electronic control circuitry eliminates all pneumatic-logic circuits, and any dependency on gas for operating power. Rechargeable batteries, fully compatible with vehicular electrical systems and airborne environments.

Uni-Vent Eagle Model 754 Portable Ventilator Features Cont. Fully self-contained, may be operated without attachment of external gas(es) and/or external power. Numerical panel markings indicate sequence-ofoperation steps to simplify and speed start-up. Graphics display includes 12-second pressure waveform. Its amplitude is calibrated to the adjacent digital bar graph. Automatically compensates pressure transducer to altitude-related barometric pressure changes up to 25,000 ft.

Your Uni-Vent Eagle Portable Ventilator Internal or External Power Internal Compressor Internal Air/Oxygen Mixer Software-generated PEEP Single-Patient-Use Circuit Fast Start-Up For use with Adults, Children, Infants

Uni-Vent Eagle Internal or External Power Internal Power External Power External Power Supply

Uni-Vent Eagle Uses internal Compressor and/or external gas(es) with internal Blender Air Oxygen Air/Oxygen Mixer Manifold Internal Compressor CPU To Patient

Getting started, the basics Ventilator circuit set-up Selecting a mode of operation Setting a ventilatory rate Setting an inspiratory time, or I:E ratio default Setting a tidal volume Setting an FI02 Setting High and Low Limit Pressure alarms

Ventilator circuit set-up Connect 22mm corrugated hose to ventilator GAS OUT fitting Connect green TRANSDUCER HOSE to ventilator TRANSDUCER hose barb (Green) Connect clear EXHALATION VALVE HOSE to Ventilator EXHALATION VALVE hose barb (clear)

The basics Select a Mode of operation Set a Ventilation Rate Set an Inspiration Time, or I:E Ratio default Set a Tidal Volume Set an FI02 Set the High and Low Limit Pressure Alarms

Additional functions External Air Sigh PEEP Pressure Plateau Manual Breath/Trigger Alarm Mute/Cancel Apnea Backup (Automatic)

Additional functions External Air External Air The EXTERNAL AIR Pushbutton Switch permits you to manually select external compressed air as your primary air source. When the ventilator is turned ON, its CPU "samples" the respective gas fitting and looks for an air pressure, greater than 40-PSI. If a lower pressure, or no pressure is sensed, the LCD will display "OFF" (default value) and the CPU allows operation to begin from the internal compressor. If a pressure exceeding 40-PSI (+/- 2 PSI) is sensed, the LCD will display "ON" and allow operation to begin from the external air supply. Manually pressing the pushbutton will toggle the display from "OFF" to "ON or from "ON" to "OFF".

Additional functions SIGH SIGH The SIGH OFF/ON Pushbutton Switch permits the ventilator to operate with or without SIGH. When the SIGH function is activated, the first ventilator-generated breath is always a SIGH. Afterwards, each additional SIGH breath is delivered once every 100 breaths or 7-minutes, whichever occurs first. A SIGH breath equals 150% of the INSPIRATION TIME setting (and the exhalation period). This will increase the delivered volume of that breath by 50%. By proportionately increasing both the inspiration and exhalation time, Uni-VentTM maintains the I:E ratio for all breaths. As a safety precaution, Uni-VentTM will not allow the inspiratory portion of a SIGH breath to exceed 3 seconds.

Additional functions PEEP PEEP The PEEP OFF/ON-SET Value Pushbutton Switch activates Uni-VentTM's internal PEEP learning software. When the ventilator is turned ON, PEEP has a default value of 0 cmh2o (no PEEP). Each time the pushbutton is pressed, PEEP is increased by 1 cmh2o up to a maximum value of 20 cmh2o (then back to 0 again). It may take several breaths for the learning process to conclude. During this period you will see a PEEP value successively added to the pressure waveform after each breath. To protect against high airway pressures, UniVentTM will dump PEEP (to 0 cmh2o) if the patient should cough.

Additional functions Manual Breath/Trigger Manual Breath/Trigger The MANUAL BREATH/TRIGGER Pushbutton Switch delivers a manual breath each time the pushbutton switch is pressed. The inspiratory time and tidal volume of each manual breath is equal to the current control settings. If a ventilator failure occurs, the operator can manually trigger a continuous flow of gas can be triggered for as long as the pushbutton switch is pressed.

Additional functions Mute/Cancel Pushbutton Mute/Cancel The MUTE/CANCEL Pushbutton Switch allows the operator to temporarily mute the audible component of an Operating Alarm or cancel the audible and flashing LED Alarm Indicator components of an Advisory Alarm. Most mute periods are 30-seconds long. An External Power Low/Failure Alarm mute will last for 5minute intervals until a Low Battery Alarm occurs and for 30-second intervals thereafter.

The LCD Screen what you can see Control settings EXTERNAL AIR, SIGH, PEEP, PLATEAU and PRESSURE ALARMS settings are displayed under their respective controls. VENTILATION RATE, INSPIRATION TIME/I:E RATIO, TIDAL VOLUME and AIR / OXYGEN MIXER settings are displayed above their respective controls.

The LCD Screen what you can see ALARM MESSAGE CENTER (AMC): The centralized location for displaying up to 4 lines of alarm message information. MODE and Vmin indicators: Displays operating mode and minute volume (A/C Mode). Inhalation/Exhalation indicator: Alternately displays the inspiration and exhalation phase of mechanical and/or spontaneous breaths. BATTERY and EXTERNAL POWER source indicators: 2-line area that displays the current status of external power, internal power, and fuses. Cont.

The LCD Screen what you can see Cont. Peak & Mean inspiratory pressures are displayed after each breath The digital bar graph displays peak pressure during each breath High and Low Pressure Limit Alarm setting tics are continuously displayed 6-second s of pressure wave form data, including PEEP is displayed Set and Delivered tidal volume are alternately displayed

Thank You! Email: gbeck@impactii.com