Negative Pressure Wound Therapy

Similar documents
Innovation at its best

extricare 3600 Operating Manual

User Manual. For Patients and Clinicians

AQUADEX FLEXFLOW SYSTEM QUICK REFERENCE GUIDE

patient education program 4156 South 52 nd Street, Omaha, NE ChildrensOmaha.org/HomeHealthcare

Nimbus II PainPRO Ambulatory Infusion Pump

*smith&nephew RENASYS GO Negative Pressure Wound

Patient Home Care Information

ADVANCING the art and science of NPWT negative pressure wound therapy

A few seconds after turning on, the screen changes to Set Up Screen Before adjusting the pressure, calibrate the O 2 sensors

Nimbus II PainPRO Ambulatory Infusion Pump

BODYGUARD 2CH TWIN CHANNEL INFUSION PUMP

ATMOS Wound Therapy. The choice is yours! ATMOS S 041 Wound ATMOS S 042 NPWT. MedizinTechnik

2015 Products Catalog Product Catalog. Products designed for the treatment and prevention of wounds

Quiz for Module 2: Aquarius Training (Rev. 1) Lesson 1: Introduction to Aquarius

AQUARIUS Continuous Renal Replacement Therapy Competency

CircuFlow Quick Setup Guide

extricare NPWT Foam Kit Instruction for Use

Use this key to determine which sections of this Product Manual apply to your job.

My CoughAssist. A patient guide to CoughAssist T70. Please visit

Glove Box Installation Manual

Liberty Cycler Handi-Guide

GE Healthcare. Centiva/5 Critical Care Ventilator. Meet a new level of expectations

KOOLKARE CAR & COMMERCIAL AIR CONDITIONING SERVICE SOLUTIONS

Portable Oxygen Concentrator. Introduction

How Ventilators Work. Chapter 3

MODEL #: CMPP-100. Nisus Negative Pressure Wound Therapy System. Instructions for Use

Endo-Flush Order # ZUTR30004 OPERATION MANUAL. Zutron Medical, LLC W 98 th St #40-27 Lenexa, KS Phone Fax

WARNING. Important Safety Information accompanies this device.

Medical Instruments in the Developing World

Complex Care Hub Manual: Pressure Ventilation on the LTV 1200

Troubleshooting Guide Aquarius

MODEL Maverick Heavy Duty Aerosol Compressor Operator s Manual

LifeChoice Activox Portable oxygen concentrator. Portable oxygen therapy for patients with active lifestyles. ResMed.com

Introduction. Medley TM Medication Safety System. Alaris Medical Systems

INSTRUCTION MANUAL. Automatic Blood Pressure Monitor with Fit Cuff. =Fit Cuff=!"#$% IA1B. Model

Device overview. 6 Breathing circuit connection. Note: When the remote control foot pedal is connected, the manual switch is disabled.

Welcome to the Specialized Medical Services Respiratory training webinar series!

EASYPUMP II THE FLEXIBLE SOLUTION FOR SHORT AND LONG TERM INFUSION THERAPIES

Patient Setup Information

Defibtech s Latest Advancement The Lifeline ARM Automated Chest Compression (ACC) Device for Professionals

Module 2: Aquarius Training

NPWT PRO and PRO to GO CLINICIAN USER MANUAL

PAIN RELIEF SYSTEM PATIENT GUIDELINES

Negative Pressure Wound Therapy System. Negative Pressure Wound Therapy Operator s Manual

Emergency Transport and Ventilation

AQUARIUS Continuous Renal Replacement Therapy with Regional Citrate Anticoagulation (RCA) Competency

Operation Manual - PN A MENSOR MODEL 73 SHOP AIR BOOSTER

Chest Drainage Systems for Cardiac & Thoracic Surgery. Including portable suction with Digital Air Leak Monitoring

Using the UltraRAE. Firmware 2.35

Digital drainage systems. ATMOS Thorax COMFORT SAFETY FLEXIBILITY MOBILITY

INTRODUCING CARDIOSAVE Hybrid MORE THAN A PUMP. A REVOLUTION. SPECIFICATIONS

Making Life Easier Easypump II

POWERPRESS UNIT. User Manual. Gradient Pneumatic Sequential Compressor. Neomedic

V8600 Ventilator. Integrated Invasive & Noninvasive Ventilation

Invia Liberty NEGATIVE PRESSURE WOUND THERAPY SYSTEM. EN Clinician instruction for use. ES Instrucciones para uso clínico

MANITOBA RENAL PROGRAM

Work Method Statement. Prepared for: The Bolton NHS Foundation Trust Prepared by: Mark Fentiman Date:

Instructions for Use

NITROGEN INFLATION SYSTEM NG-4, NG-6, NG-12, NG-18

Portable Oxygen Concentrator. Give your patients more freedom with mobile oxygen on demand

Alaris Pump module FAQs

Sanity G6 NPWT System User s Manual

S/5 Aespire. Quick Reference Guide

KOOLKARE CAR & COMMERCIAL AIR CONDITIONING SERVICE SOLUTIONS

Operation Manual. H & R Healthcare 1750 Oak Street Lakewood, NJ Phone: Fax:

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50 Systems Outfitted with ABM-725 Monitor C O M P A N Y

Med Aire Alternating Pressure Pump and Pad System

Magic Carbo CMV1.3. Carboxytherapy Equipment. User Manual

Maintenance and Troubleshooting of Pneumatic Conveying Systems for Sand in a Foundry

IEC C LASSIFICATIONS:

Bunnell LifePulse HFV Quick Reference Guide # Bunnell Incorporated

Microfluidic Demonstration

The ultimate in water softening

DG100 Digital Depth Gauge and Timer. Training Module, Rev B

450P AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

MODEL NUMBER: P-A AUTOMATIC PORTABLE COMPRESSOR

Expanding versatility. The upgraded Trilogy family of ventilators continues to meet the changing needs of your patients

OPERATION. Estimated kerf width compensation. HPR260 Manual Gas Instruction Manual 4-9

Liberty Handi-Guide A Patient s Reference to the Most Commonly Asked Questions About the Liberty Cycler

Astral in AirView: Improving patient care through connectivity. ResMed.com

Digital Display large color coded LED display is easy to read precise measuring shows actual cuff pressure

Tourniquet System. Ideal for single or bi-lateral orthopaedic surgery and pain management

Liquid with a surprise HomeLox makes and stores liquid oxygen at home

DRS4-RM Manual. Set Up Instructions for DRS4 Series Single Tank

Introducing Astral. Greater freedom. Confident care. Designed efficiency

SR500 PAPR Copyright 2015 by The S.E.A. Group 1

Operation and Maintenance of the MCV100 and MCV100-B Portable Ventilator

ECE 477 Digital Systems Senior Design Project Rev 9/12. User Manual

Liberty PDx Cycler Handi-Guide

The Univentor 1250 Anaesthesia Unit

Calcium Reactor. CalcFeeder PRO. User Manual 1.1a. Model. CalcFeeder AC1 PRO CalcFeeder AC2 PRO CalcFeeder AC3 PRO CalcFeeder AC4 PRO

GE Healthcare. Aestiva/5. More than superior ventilation

Hospital and Transport for Controlled Breathing

Operation of Oxylog 3000 ventilator

SomnoSuite FAQ. Setup. Calibration 4. What are the calibration requirements for the SomnoSuite? Settings

Redesign - ATMOS S 201 Thorax. Digital thoracic drainage systems. ATMOS Thorax MOBILITY SAFETY COMFORT FLEXIBILITY

Quick Response Pneupac VR1 Emergency Ventilator AIRWAYMANAGEMENT

Pegas 4000 MF Gas Mixer InstructionManual Columbus Instruments

Roller AC Servo System

Transcription:

Guide to Continuous Therapy DeRoyal Pro Series easy use guide to continuous therapy To turn unit On: Press the ON or OK button. To reach option mode to input settings: Hold the up arrow button and the down arrow button simultaneously. - Options for choices Continuous, Intermittent, or Language will appear on screen. To input Continuous settings and start therapy: Press OK while highlighted over Continuous. The appearing screen is to change setting by pressing the up or down buttons. - Pressure will increase or decrease by -5mmhg increments. - Press OK when desired pressure is reached. The screen remains yellow/idle and allows for the pressure to be reviewed and confirmed. Press the OK button to START therapy, screen will turn green. - Pressure will slowly pull down by -5mmhg increments until desired level reached. - The large number present on the screen is the therapy level, the small number to the right is the input pressure level. - A small bar will appear on the left hand side of the screen, it reads too tight at the top and not tight at the bottom. The bar will raise to too tight if not enough air flow is within the system; not tight will cause an alarm if there is a large air leak. - The screen will automatically lock after 15 minutes of uninterrupted therapy; however, if clinician prefers to expedite the lock, press and hold the up arrow and down arrow buttons simultaneously, a small padlock will appear in the lower left hand corner. To stop or pause therapy from Continuous mode: Unlock unit if a padlock to the lower left hand side near the battery is present. - To unlock, press and hold the up and down arrow buttons simultaneously until the padlock disappears from the LED screen. To pause, press the On or OK button once. To turn unit off, press and hold the Off or C button for 3 seconds. The unit is powered off when the LED screen is dark. Reprint # 0-2382

Guide to Intermittent - VPT Therapy DeRoyal Pro Series easy use guide to intermittent - VPT therapy To turn unit ON: Press the ON or OK button. To reach OPTION MODE to input settings: Hold the up arrow button and the down arrow button simultaneously. - Option Mode choices Continuous, Intermittent, and Language will appear on screen. To input Intermittent - VPT settings and start therapy: Press down arrow to choose mode. Press OK while highlighted over intermittent - VPT. Change setting by pressing the up or down buttons to set levels in the next 4 screens. - Pressure will increase or decrease by -5mmhg increments. - Press OK when desired level is reached for high therapy pessure. - Press OK when desired level is reached for low therapy pressure. - Press OK when time for high therapy pressure is input. - Press OK when time for low therapy pressure is input. The screen remains yellow/idle to allow review of pressure and time input levels. Press the OK button to START therapy, screen will turn green. - Pressure will slowly pull down by -5mmhg increments until desired level is reached. - The large number present on the screen is the therapy level; the small number to the right is the input pressure level. - A small bar will appear on the left hand side of the screen. It reads too tight at the top and not tight at the bottom. The bar will raise to too tight if not enough air flow is within the system; not tight will cause an alarm if there is a large air leak. - Once this bar disappears from the left hand side, a timer bar will appear at the top of the LED screen. Once high pressure phase is met the timing bar will progress from left to right for the duration of high pressure therapy. Once max time is reached, pressure will slowly decrease to the low pressure phase and timing bar will reverse from right to left for the duration of low pressure therapy. This cycle repeats. - The screen will automatically lock after 15 minutes of uninterrupted therapy; however, if clinician prefers to expedite the lock, press and hold the up arrow and down arrow buttons simultaneously, a small padlock will appear in the lower left hand corner. To stop or pause therapy from Intermittent VPT mode: Unlock unit if a padlock to the lower left hand side near the battery is present. - To unlock, press and hold the up and down arrow buttons simultaneously until the padlock disappears from the LED screen. To pause, press the On or OK button once. To turn unit off, press and hold the Off or C button for 3 seconds. The unit is powered off when the LED screen is dark. Reprint # 0-2383

Guide to Troubleshooting Alarms DeRoyal Pro Series easy use guide to troubleshooting alarms When a Prospera computer detects the set level of therapy is not adequate, the LED will turn RED and System Closed, System Open, or Check Dressing Seal, will appear on the screen. Other possible alarms include Battery Low, Battery Empty, or Restart Pump. The detected alarm will appear on the red screen in black writing. System Closed Alarm: and to silence the alarm. Possible The canister is full. Drainage has filled the canister to reach the filter/sensor. - Change canister. Filter is compromised this is caused if the unit has been placed on its side and drainage has come in contact with the fliter at the suction area of the unit. - Change canister. Tubing is kinked, clamped off, or being lain on. - Be sure all clamps are released, tubing is straightened, and patient is not laying on the tubing in any area. In rare cases, too many layers of Transeal may have been placed over the patients wound, which will decrease the moisture vapor transmission rate and will not allow the necessary air flow for the unit to function at the proper therapeutic level. - To prevent this, please educate all clinicians to use the least amount of Transeal possible for each dressing change. Less than 3 layers is preferred. Reprint # 0-2384 System Open Alarm: and to silence the alarm. Possible The motor has run for 30 seconds without reaching the set pressure. - Press OK and restart unit. Canister is not connected properly. - Remove canister. Line up track at the base of the canister while replacing the canister until it clicks in place. Tubing is not connected properly. - Check all tubing to be sure all closures are tightly connected. Check Dressing Seal Alarm: Possible Dressing seal is allowing too much air into the system, which prohibits the negative pressure to reach the indicated level. continued on reverse

- 2 - Guide to Troubleshooting Alarms continued continued from page 1 - Assess dressing around edges and any overlapped Transeal areas to determine area of leak. Press firmly around the wound bed and edges to locate leak area. - Place small amount of Transeal over the compromised area. - If unable to initially locate the leak, use a skin prep pad over the dressing and watch/listen closely for change in noise to determine leak area. Battery Low Alarm: Only 25% of battery life remains. - Will alarm every 15 minutes until unit battery is empty. - Plug in unit to the AC adapter and power source. Battery Empty Alarm: Battery charge has fully depleted and unit will turn off unless plugged into the AC adapter. From completely empty, this unit will take 6-7 hours to fully charge. - Plug in unit to the AC adapter and power source. Restart Pump Alarm: Therapy was not initiated within 15 minutes of turning on the unit or pausing the unit. - Press OK to start therapy. LED will turn green when therapy is being provided. Rev. 3/2015

PROSPERA ADVANCED NEGATIVE PRESSURE WOUND THERAPY SOLUTION ENHANCEMENTS TO CURRENT NPWT TECHNOLOGY Provides clinician two modes of NPWT, continuous and an innovative enhanced intermittent pressure therapy mode called variable pressure therapy. Variable pressure therapy (VPT) provides an advanced form of intermittent pressure that creates a gentle massage effect eliminating painful high to low spikes characteristic of traditional intermittent pressure therapy. o Allows NPWT to be performed at lower negative pressures compared to continuous and traditional intermittent pressure Recommended pressures between -40 to -85 mmhg VPT delivered by adjusting applied negative pressure in 5 mmhg increments according to a sinusoidal function. Sinusoidal application of pressure gradients greatly reduces pain to the patient Continuous therapy from other manufacturers routinely applied at high pressures (-125 to -200 mmhg) Eliminates the 0 to -125 mmhg gradient associated with intermittent therapy that is the cause of pain associated with intermittent therapy The duration of the maximum and minimal pressures and the gradient transitions between the two pressure extremes is programmable by the clinician Negative pressure is always applied to the wound under VPT At 0 mmhg (intermittent) no therapy is applied to the wound bed Prevents removed exudate from re-entering wound from Foam or gauze during the off period in intermittent mode. Able to customize therapy to each patients need o Ranges from -10mmhg to -200mmhg at increments of -5mmhg pressures can be decided upon by the clinician. o Option to apply continuous or variable pressure available to clinician o Ability to adjust alarm sensitivities and monitor patient compliance with a clinical screen patient mode. Proprietary Dual Filtration System DFS is an industry first featuring internal and external bacteria filters to ensure patient safety and prevent cross contamination. (Pro III) Lower pressure settings enhance comfort during use while providing necessary therapy Large display screen with easy to monitor and understand wording/functioning increasing patient safety o Color coded display screen to signal if the unit is idle yellow, functioning green, and/or error message red. Easily transferred from a hospital unit to a home unit without having to disrupt therapy Lighter weight for the portable unit (2.65lbs) and the larger unit (3.97lbs), o Increases mobility for patients o Lightweight makes patients more comfortable and transferable. Contoured design of pump increases patient comfort while the pump is worn Carrying case that can be worn on the waist or over the shoulder. Dressings available to meet any patients needs and even able to be designed specifically to the facilities desires of what is in each dressing. DeRoyal can customize any kit to the facilities wants. With industry standard black foam, a white foam option, silver contact layer options, gauze options, there is a large amount of flexibility to what each patient needs for their wound care. Dressing changes remain the same in what clinicians are familiar with. Drain kits available for use of instillation of fluids into the wound bed, if desired. Virtually silent operation Discreet, disposable canister Over 24 hour battery run time, rechargeable lithium-ion battery. Partnership to help keep finances in the facilities and communities vs a rental model Powell, TN 37849