DYNAMIC COMPRESSION THERAPY

Similar documents
DYNAMIC COMPRESSION THERAPY

POWERPRESS UNIT. User Manual. Gradient Pneumatic Sequential Compressor. Neomedic

Intermittent Pneumatic Compression System

Company building TOTAL SOLUTION OF AIR COMPRESSION THERAPY SYSTEM. New second factory. Main office & Factory Stories house

User manual. PG132 Rev01 Editi Compressive Limbs Therapy System DVT-7700

LYMPHA PRESS MANUFACTURED BY MEGO AFEK IMPORTED BY LYMPHA PRESS USA, Ltd. USERS MANUAL LYMPHA PRESS MODEL 201-M

FLOWTRON HYDROVEN 3. User Manual. Intermittent Pneumatic Compression System

Med Aire Alternating Pressure Pump and Pad System

Customer Service See Service Provider Documentation

User Manual. Indications for safety use This product is intended for use by medical professionals or patients who are under medical supervision.

User Manual DIRECTHEALTHCARESERVICES.CO.UK

Paradise Pump Series Operator s Manual

CircuFlow Quick Setup Guide

CircuFlow TM 5150 Series

OPERATING INSTRUCTIONS FOR USE GUIDE

CircuFlow 5200 Series

User manual. MNPG 102 Rev. 04 Edition 04/02/16. Pressotherapy model. Power-Q1000 Premium

SC505 Sof Care Inflator. Operating Instructions and Service Manual

Theatre Control Panel. Instructions for Use. January 2017 ASF-29 (1)

Instruction Manual for Configura Cushionair Portable Pump

12 Chamber Pump & Garment System for Lymphoedema

User Manual DIRECTHEALTHCARESERVICES.CO.UK

User Manual. PULSE User Manual WARNINGS

CircuFlow TM 5208 Series

6833_INSTRUCTIONS MANUAL DIGITAL WIRST BLOOD PRESSURE

Pressure Automated Calibration Equipment

ORB-400 BUBBLE/HAZE MACHINE. Item ref: UK User Manual

Air Plus User Manual

User Manual DIRECTHEALTHCARESERVICES.CO.UK

Welcome to the World of In-Home Gardening! Simple Steps to Get Your AeroGarden Up and Growing (No Tools Required)

Welcome to the World of In-Home Gardening! Simple Steps to Get Your AeroGarden Up and Growing (No Tools Required)

Model IC-BAP-DL BioArterial Plus

77-I0PN230 Rev. A. Model 1030 User Manual

SkillGuide. User Guide. English

My CoughAssist. A patient guide to CoughAssist T70. Please visit

NIMBUS range. with people in mind

Pegasus Aircare Mattress Overlay System Models 2200 and 2201

Comfortmax Thermax Hot/Cold Water Circulation System. Instructions for Use

F-330 Instruction manual. Magic Glove Bio Skin Smoother High Frequency Ultrasound Galvanic

Regalia Oxygen Concentrator

HZ-300 HAZER MACHINE USER MANUAL. Congratulations on the purchase of your new ANTARI HZ-300 Haze Machine.

Operator s Manual. Dynamic Low-Air-Loss Therapy with Alternating Pressure

SEQUENTIAL CIRCULATORS

Alternating Pressure / Low Air Loss Mattress System

ActiveCare+SFT and ActiveCare+DTx Patient Instructions for Use

Operation Manual. H & R Healthcare 1750 Oak Street Lakewood, NJ Phone: Fax:

Operating Instructions Part No

User Guide Antidecubitus systems EURO BASIC

Model 1700 Patient Operating Instructions. Model 1700

AC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight

USER MANUAL SAVE THESE INSTRUCTIONS. For the most current manual revision, please visit our Website:

OPERATOR s MANUAL AHCON PCI 3000

INSTRUCTION MANUAL MANUAL INFLATION BLOOD PRESSURE MONITOR

User manual. PG89 Rev 01 Editi Pressotherapy model. LymphoPress 4

*smith&nephew RENASYS GO Negative Pressure Wound

STANDARD OPERATING PROCEDURES DIVISION OF COMPARATIVE MEDICINE UNIVERSITY OF SOUTH FLORIDA

Zenith Technical Innovations, LLC User Manual

FLOWTRON ACS800 +TRI PULSE INSTRUCTIONS FOR USE

Instructions for Cleaning & Maintaining Air Compressor

Digital Melting Point Apparatus

MODEL Maverick Heavy Duty Aerosol Compressor Operator s Manual

AHE58/59 AC Servo System

Roller AC Servo System

OC4000 USER'S GUIDE I O OXYGEN CONCENTRATORS OXYGEN CONCENTRATOR FOR VETERINARY USE ONLY GLOSSARY OF SYMBOLS. : ON (power switched on)

Diamond 8 Plus. Alternating + Micro Low Air Loss Pressure Relief System. User Manual. Distributed by: Quart Healthcare Inc.

ProSeries 2. Blood Pressure Monitor. Quick Start Guide. A complete user guide is available at vitasigns.com

AUTOMATIC TIRE INFLATOR # MW-60, MW-60-4WAY & MW-64HP

User Manual. 10. Dimensions and Ordering Codes. Integrity Alternating Pressure Mattress System. Alternating Pressure Mattress Systems

MA90 Series Mattresses. MA95 Series Mattresses

OPERATING INSTRUCTIONS FOR

Table of Contents. Introduction. Preparation Training. After training. Maintenance. Before use P.1 Warning/ Caution. P.2-3 Included parts P.

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

MIE Medical Research Ltd Digital Analyser Pinch/Grip Instruction Manual

INDUSTRIAL - SOLVENT PARTS CLEANER

USER MANUAL LTH-255A Hand Piece

SYMBOL DEFINITIONS. CAUTION: High pressure should be set with caution on patients with peripheral arterial occlusive disease.

VERTICAL AIR COMPRESSORS

VERTICAL AIR COMPRESSORS

OPERATING INSTRUCTIONS FOR MODEL VSBX

OC4000 USER'S GUIDE I O OXYGEN CONCENTRATOR FOR VETERINARY USE ONLY. by Supera Anesthesia Innovations GLOSSARY OF SYMBOLS. : ON (power switched on)

Portable oxygen concentrator

OPERATING INSTRUCTIONS FOR

BMR 2100XL Operating Instructions Page 1 of 13

Introduction. Table of Contents. Automatic Wrist Blood Pressure Monitor With Voice-Guided Operation. Model No.: BP5K

Training. Testor Training Manual

AUTOMATIC GAS MANIFOLDS

User Manual. Hopkins IMPACT Digital Wrist BP RELATED ITEMS. Item #526014

User Manual DIRECTHEALTHCARESERVICES.CO.UK

CONGRATULATIONS ON YOUR PURCHASE OF YOUR THUNDER COMPRESSOR For your personal safety please read, understand and follow the information provided in

Concentrate Distribution System (Stand Mounted) A-CDS-70-X & A-CDS-TANK-X-ST Industrial Drive, Orlinda, TN 37141

NICE1 Cold + Compression Therapy System

Arterial Puncture Wrist

User Manual DMD1001 1

Resusci Anne Simulator

OPERATING INSTRUCTIONS PSORIAMED. Revision: 1.0-D GB

Recline Forma. User manual

SAVE THESE INSTRUCTIONS A300 MASSAGE CHAIR. Operation Instructions

Contents. 中文日本語 Br Es Nl De Fr It Uk

User Manual DMD1001. Arm Type. Digital Blood Pressure Monitor. version:1.0

NITROGEN INFLATION SYSTEM NG-4, NG-6, NG-12, NG-18

Transcription:

PULSE PRESS DYNAMIC COMPRESSION THERAPY MULTITEC 12 User Manual May 2011 0120

CONTENTS:- SAFETY INSTRUCTIONS ELECTROMAGNETIC INTERFERENCE DESCRIPTION OF CONTROLS MODE SELECTION OPERATING INSTRUCTIONS CARE AND MAINTENANCE INDICATIONS AND CONTRA-INDICATIONS TECHNICAL SPECIFICATIONS PULSEPRESS DYNAMIC COMPRESSION THERAPY

SAFETY INSTRUCTIONS Read all of these instructions and save them for later reference. Follow all warnings and instructions marked on the devices. These units must only be operated by qualified medical staff. Operation of these units by any other person is entirely the responsibility of that person. This manual must be read and fully understood before these units are applied to patients. Equipment not suitable for use in the presence of Flammable Anesthic mixture with air or with oxygen or nitrous oxide. Unplug the pumps before cleaning. Only ever use a damp cloth. Do not spill liquid onto the pump enclosure. Always place pumps on a flat, stable surface before operation. The pumps will not operate properly if tilted or at an angle. Do not cover the pumps whilst in operation. Use only the type of power source indicated on the pump s rear label. Do not use a damaged or frayed power cord. Unplug the pumps and refer servicing to qualified personnel under the following conditions:- o If the power cord or plug is damaged. o If liquid has entered the pumps. o If the plastic outer enclosure is damaged. o If the pump is not operating normally, continuous running, noisy running or low performance. Always switch off the pump before unzipping the garments. ELECTROMAGNETIC INTERFERENCE This equipment has been constructed and tested to comply with EN60601-1- 2 (EMC regulations for Medical devices). This test was designed to provide reasonable protection against harmful interference. This equipment may generate and radiate radio frequency energy and, if not installed correctly may cause interference to radio communications. If this equipment does cause interference then the user is encouraged to try to correct the interference by one or more of the following measures:- Re-orientate or relocate the receiving antenna. Increase the separation between the equipment and the receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the manufacturer of the device. PULSEPRESS DYNAMIC COMPRESSION THERAPY

Pump CONTROLS 4 5 6 7 3 2 8 1 9 11 10 PUMP CONTROLS 1. External fuse holder. Replace with 500mA Slo-Blo 2. Power Inlet. Use with 220-240v AC 50 Hz 3. Air outlet for use with single garment. 4. Air bung. Remove for inflating two garments at a time or trousers 5. Power button. 6. LCD Display. Shows treatment settings. 7. Start / Stop button. Push to start or Stop treatment. 8. Inflation progress bar. Shows user progress of inflation cycle. 9. Up button. Used to move through menu selection. 10. Down button. Used to move through menu selection. 11. OK button. Used to make a selection in menu settings.

MoDE SELECTION MODE SELECTION EXPLANATION LYMPH LOW Set to treat lymphoedema at low pressure Pressure 40mmHg Inflate 90secs Deflate 45 secs Therapy 60mins LYMPH HIGH Set to treat lymphoedema at high pressure Pressure 60mmHg Inflate 90secs Deflate 45 secs Therapy 60mins SPORTS LOW Set to treat sports injuries at low pressure Pressure 40mmHg Inflate 40secs Deflate 25 secs Therapy 60mins SPORTS HIGH Set to treat sports injuries at high pressure Pressure 60mmHg Inflate 40secs Deflate 25 secs Therapy 60mins WOUNDS LOW Set to treat open wounds at low pressure Pressure 40mmHg Inflate 40secs Deflate 25 secs Therapy 60mins WOUNDS HIGH Set to treat open wounds with twin garments Pressure 40mmHg Inflate 75secs Deflate 45 secs Therapy 60mins WELLNESS LOW Set to Wllness mode at low pressure Pressure 30mmHg Inflate 90secs Deflate 60 secs Therapy 60mins WELLNESS HIGH Set to Wllness mode at high pressure Pressure 45mmHg Inflate 90secs Deflate 60 secs Therapy 60mins CUSTOM MODE Allows user to set treatment settings Pressure 30-100 mmhg Inflate 20-180 secs Deflate 15-60 secs Therapy 30-120 mins

Operating Instructions WARNING: These units must only be operated by qualified medical staff. Operation of these units by any other person is entirely the responsibility of that person. WARNING: This manual must be read and fully understood before these units are applied to patients. WARNING: Refer to section on indications and contra-indications prior to the unit being applied to patients. Application of Garment to Patient These units are designed to provide compression to the Pulse Press range of Multi pressure garments. Each unit can be connected to one or two garments simultaneously. If only one garment is being used then the other outlet is sealed, unless you are using the trouser garment. For the Multi pumps the blanking plug must be removed to use a second garment and the trouser garment. The hoses connection is unable to be the wrong way round. The other end of the air feed hose simply pushes onto the garment. Unzip the garment and place around the patients limb. Always fully zip the garment up before starting treatment. Do not unzip the garment during treatment. Wait for garment to be deflated before removing from patient. Operational Use 1. Connect the mains lead to the IEC power inlet socket. Insert the mains plug of the lead into a standard 220-240V mains socket. 2. Fit the air feed hose(s) to the air outlets, as described above. Ensure that all connections to the pump and garment make a good seal. 3. Place / fit the garment(s) onto the limb(s) requiring treatment. 4. Press Power button. LCD Display will ask user to read user manual. 5. Press Start / Stop button to resume previous treatment cycle. If different treatment is required then press OK to enter mode selection menu. 6. During operation to pause the treatment press the Start / Stop button. The garment will deflate. To resume treatment press Start / Stop button again. 7. The Inflation Progress Bar shows the user where in the inflation cycle the system is. 8. On completion of therapy timer the system will vent the garment and wait for user to reset system.

Operating Instructions 9. To change the mode use the Up and Down buttons to change program until the desired mode is shown on the screen. Then press the OK button to select the mode. 10. Then press the Start / Stop button to run the selected mode. 11. If the Custom mode has been selected then the user must follow the on screen instructions by using the Up / Down and OK buttons. 12. Below is the sequence of variables to set:- a. Use the Up and Down buttons to set the desired pressure in mmhg. You can select between 30-100mmHg. Press the OK button to set the pressure shown on the screen and continue to the next stage of set up. b. Use the Up and Down buttons to set the desired inflation time in seconds. You can select between 20-180 seconds. Press the OK button to set the inflation time shown on the screen and continue to the next stage of set up. c. Use the Up and Down buttons to set the desired deflation time in seconds. You can select between 15-60 seconds. Press the OK button to set the deflation time shown on the screen and continue to the next stage of set up. d. Use the Up and Down buttons to set the desired therapy time in minutess. You can select between 30-120 minutes. Press the OK button to set the therapy time shown on the screen and continue to the final stage. e. Press the Start / Stop button the run the custom treatment as selected.

CARE AND MAINTENANCE PUMP Before cleaning the pump unit, always ensure it has been disconnected from the mains power supply. Clean the unit with a light detergent, ensuring that only a damp, and not wet, cloth is used. If in doubt as to the action of the detergent, try cleaning the underside of the unit first, where damage will be unseen. There are no service items which need replacing or cleaning out on a regular basis. All technical information can be found at www.mjsgrp.com. GARMENT The garments can be sponged with a detergent. Allow to dry fully before use. DO NOT FORCE DRY. In the event of heavy soiling the garments can be machine washed. See wash label. Always insert the air entry blanking plug, to prevent water ingress, and turn the garment inside out prior to machine washing. indications AND CONTRA-INDICATIONS INDICATIONS VENOUS Post phlebetic syndrome, varicose veins, varicosities of pregnancy, stasis dermatitis, leg ulcers. WOUND RECOVERY D.V.T. ARTERIAL EDEMA FLEXION CONTRACTURES Venous ligation or stripping, hand surgery, total knee replacement. For prevention of deep vein thrombosis. Raynaud s disease, arteriosclerosis, acro cyanosis, blue leg. Gravitational, lymphatic, post mastectomy, inguinal lymphadenectomy, after cast removal, rheumatoid, multiple sclerosis. Chronic, injury, burns and skin graft. CONTRA-INDICATIONS Acute thrombophlebitis, acute pulmonary edema, congestive heart failure, known or suspected deep vein thrombosis. PULSEPRESS DYNAMIC COMPRESSION THERAPY

technical specifications Power Source Frequency Internal Fuse 220-250V AC 50Hz T500mAL250V Type BF Caution Equipment not suitable for use in the presence of Flammable Anesthic mixture with air or oxygen or nitrous oxide. Read instructions prior to using equipment. Keep Equipment Dry. Do not spill fluid on device. Mode Intermittent Operation Storage / Operation Equipment to be stored / used between 15 and 30 degrees C Equipment suitable for use 0-50% humidity. Pressure Regulation LCD Display Power Consumption Range 30-100mmHg +_ 5mmHg 16 x 2 Blue Backlite LCD Module 40W Class II (Double Insulated Device) Accessories Only use PulsePress hoses and garments Only use power lead supplied PULSEPRESS DYNAMIC COMPRESSION THERAPY

Operating Instructions

Barton Business Park Barton-le-Clay Bedfordshire MK45 4RP, England MJS Healthcare Ltd Reg No 2217463 Vat No 491191245 +44 (0) 1582 344 970 +44 (0) 1582 882 176 sales@mjsgrp.com www.mjsgrp.com