blue by Riiot OPERATING INSTRUCTIONS

Similar documents
PRODUCT MANUAL. Diver Smart Interface Cable AS346

NEULOG OXYGEN LOGGER SENSOR GUIDE

Instruction Manual SWIMMINGPOOLCHEMICALS.CO.UK

MAGICFX CONFETTIPISTOL USER AND INSTALLATION MANUAL

Cadence Sensor W.I.N.D. User Manual

ATS430 turbidity sensor Retractable insertion assembly

UsER manual for Watersens ph -REDOX

PRODUCT SHEET. Order probe only as RXPROBE02

SkillGuide. User Guide. English

User Manual. GPL 3000 e. gas detector

Elcometer 138. Bresle Kit and Patches. Operating Instructions

Oxygen Sensor with Electrode

Refillable ORP/Redox Probe: Model MTC30101 or MTC30103

LDO II AQ 2/2014, Edition 1.5

Nothing's as cool, as a freshwater pool. easychem 770 ORP and ph Controller for Pools and Spas with Timer Output for Pool Pump

Bante820 Portable Dissolved Oxygen Meter Instruction Manual

LogIT Dissolved Oxygen Probe

Elcometer 138. Bresle Kit and Patches. Operating Instructions

TOPLINE ELECTRONICS LTD CO2 CONTROL UNIT MANUAL

Alcotest Breath Alcohol Screening Device. Operator Instructions for Use. ST _sw.eps

11. Aquasalt. Aquasalt Aquasalt 440. Salt electrolysis demonstration 442. Spare parts and Accessories 443. Chemical Products

Bante810 Benchtop Dissolved Oxygen Meter Instruction Manual

APPROACH S10. Owner s Manual

130 SSP Soluble Salt Profiler

Bante821 Portable Dissolved Oxygen Meter Instruction Manual

APPROACH CT10. Owner s Manual

Water Testing Technologies: Stepping Into the 21 st Century Ivars Jaunakais

Pool and Spa. Water Testing

INSTALLER S CHOICE. simple to fit. simple to use. simply smarter. ride the wave to smarter heating and hot water control THE

KREEPY KRAULY. Anytime from anywhere on earth. Pool monitoring and control system.

PLEASE READ CAREFULLY BEFORE INSTALLING OR USING MEGA POOL SAVER MPS 1100

Instruction Sheet. Important Note: Information that requires special emphasis. Note: Information that supplements points in the main text.

Resusci Anne Simulator

SS32L Dissolved O 2 Probe

DOscan10 Pocket Dissolved Oxygen Tester Instruction Manual

User Manual 1 P a g e Rev. V1.6-EN 11/08/2014

Operating Manual VSA100A. tina29e1 ( )

HI 2314 HI 2315 HI 23151

Digital pressure gauge Model CPG500

EC214 EC215 - EC215R Bench Conductivity Meters

How to use my FishHunter Directional 3D

Instructions for Installation, Use and Maintenance FSI Safety Tank Shower Systems

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

Gas Pressure Probe. Information Sheet. Total Dissolved Gas

PitchTracker User Guide. Model: DKPT01 User Guide

BI-680 Online Dissolved Oxygen Controller Instruction Manual

PitchTracker User Guide. Model: DKPT01 User Guide

PitchTracker Softball User Guide

e.do Gripper Safety requirements, technical features and assembly and integration instructions

6200 Isoperibol Calorimeter Model Number: 6200

FOR USE WITH PALINTEST POOLTEST 9 SERIES PHOTOMETERS

NIV EAU MATIC ST User Manual Made in Canada

INSTRUCTIONS. VP-100 Ion Pump. Model / R001

Approach. owner s manual

Instruction Manual HI Portable Dissolved Oxygen Meter. DO meter HI 8043 STB C OFF O 2 ZERO SLOPE C. ins rum n s

v /07/17 Page 1 of 18

6833_INSTRUCTIONS MANUAL DIGITAL WIRST BLOOD PRESSURE

Introduction The Smart Q Oxygen Adaptor enables an Oxygen electrode to be connected to an EasySense unit.

The Oxygen Sensor can be connected to all types of einstein Tablets, einstein LabMate, and einstein LabMate +.

USER GUIDE USER GUIDE

ZEPP GOLF USER GUIDE. Mar 2016

VELUX ACTIVE with NETATMO

Hand-held pressure calibrator with integrated pump Model CPH6600

User Manual Pocket Pro + Multi 1

SNOW PICKETS` Climbing and Mountaineering Equipment. Foreword

Aqua-DP. Aqua-DP Waterproof Dissolved Oxygen - ph -mv Temperature Meter. TPS Australia - Quality hand-made instruments since 1968.

ASE SOLVENT CONTROLLER INSTALLATION INSTRUCTIONS Dionex Corporation

Aerobic Respiration. Evaluation copy

max 80 cm / 2 6 Trittfrequenzmesser Capteur de Cadence Trapfrequentie Sensor Sensor de Cadencia Sensore di Cadenza Sensor de CadĂȘncia Kadencesensor

User Manual. Heads-Up Display (HUD) DiveCAN. Mechanical Button Version

Sooriyan Pool and Spa Ionizer. by Hilltop Solar

OPERATION MANUAL BFX-2

Evaluation copy. Interdependence of Plants and Animals. computer OBJECTIVES MATERIALS

DOG DUAL USER MANUAL THE SAFETY LIGHT MADE IN DENMARK. Register for your 3-year warranty at

Pooltest. Test Kits. Professional Plus INSTRUMENTS POOL.INST.44

BiiSafe Buddy User Guide

JOLLY2. Installation user s manual. 6 different operating modes selectable. version 3.3. DATA TO BE FILLED OUT BY THE INSTALLER (Page 1)

Digital Melting Point Apparatus

Manuals Mandatory! New EU Legislation for Electrical Appliances. Matthias Schulz, Erkelenz AXELENT ProfiServices

Semi-Automatic Controllers

LC-SPE. Organizer 3.0 User Manual. Innovation with Integrity. Version 001 NMR

BD Cytopeia Fluidic Kit User s Guide

SAFETY DATA SHEET according to 1907/2006/EC, Article 31

SPECIFICATIONS APCEPH1

Ambient Weather WS-03 Thermo-Hygrometer

STERILIZABLE DISSOLVED OXYGEN SENSORS

SERVICE INSTRUCTIONS

SAFETY DATA SHEET - CHLORINE SANITISING TABLETS

SAFETY DATA SHEET according to 1907/2006/EC, Article 31

Fully Automatic ihealth Track Connected Arm Blood Pressure Monitor USER MANUAL

PREPARED BY: Marshall K. Cheung, Ph.D., Laboratory Director. REVISED BY: Marshall K. Cheung, Ph.D., Laboratory Director

Topline Peristaltic Dosing Pump for PAC Installation, Commissioning and O&M Manual

AQUARIUS. Operating Instructions for the. Type 70 Electrolytic Gas Soldering / Welding Unit. Table of Contents

Operating manual. Oxi 3205 O mg/l C. [Sal] Dissolved oxygen (D.O.) meter

Air Sensor. FCS Ex. Manual. AQ Elteknik AB

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

DM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

Endura AZ40 Sensor assembly Smart electronics PCB

Operating instructions Binary level sensor LI / / 2013

Waste Management System.

Transcription:

blue by Riiot OPERATING INSTRUCTIONS

Introduction Overview blue constantly measures the main parameters of your swimming pool (temperature, ph, chlorine, salinity). blue also displays external temperature and local weather. Results of this analysis are ommunicated to you via notifications sent to the blue by Riiot application (available on smartphone and tablets compatible with Android and ios). If blue detects an imbalance in one or more of your pool s parameters, an alert is sent via the app along with advice allowing you to easily correct and stabilise the parameter in question thus ensuring you maintain a clean and balanced water quality. blue measures the following:» Water Temperature ( C, F): An elevated temperature reduces the efficiency of chlorine and promotes the development of microorganisms.» ph (potential of Hydrogen): This important characteristic of any swimming pool is the balance between acidity and alkalinity. ph is crucial to the disinfectant level of your pool.» ORP/REDOX (measure of active chlorine which is expressed in mv): The oxidation-reduction potential, or REDOX potential, measures the oxidisation strength or reduction potential of one substance to another. It signifies the disinfectant strength of the water.» Salinity (g/l): Salinity is the measure of the quantity of salt dissolved in water. Precautions for use» Do not use blue for anything other than water analysis.» blue is not a toy. Avoid sudden impacts at risk of damaging the device.» Keep blue out of the reach of children when handling (e.g. calibration and putting on standby) due to the use of chemical products. Stock calibration products out of the reach of children.» Do not leave the probe out the water for more than an hour without placing it in the storage cap suitably filled with KCl (saturated potassium chloride), ph4 solution, or as a last resort, in water from the swimming pool.» Do not use demineralised water in the storage cap.» Ensure that blue remains vertical and that the upper section is above the water to ensure that the device communicates correctly.» Do not leave blue in water below 5 C or above 40 C.» It is essential to keep blue s serial number and code 1 (KEY).» Do not open the top of blue.» Store blue in a frost free environment. 2 1 On the back of the quick start guide or on blue s base.

Description of equipement» blue analyser: it is delivered secured in the storage cap to protect the probe during transportation. The probe is stored in KCI (saturated potassium chloride), which assures its protection.» The storage cap: it is used when the probe needs to be transported, kept out of water for more than an hour, or for prolonged storage (during winter for example).» The usage cap: it must always be mounted before placing blue in water. It protects the sensors from any damage.» Calibration products: there are hermetically sealed in an opaque container which contains the exact quantity of solution necessary for two calibrations.» 2 20 ml sachets of ph 4.» 2 20 ml sachets of ph 7.» The quick start guide. 3

Installation of the app 1. Activate the Internet (Wi-Fi or 4G) and Bluetooth on your smartphone or tablet. NB: Remain in proximity to your blue throughout the activation process. 2. Go to go.riiotlabs.com or download the application blue by Riiot. The free app is available for free via the App Store and Google Play. 3. 4. 5. To benefit from alerts, ensure you authorise notifications from the app. Connect to blue by Riiot :» via Facebook.» via Twitter.» via your email. Create your swimming pool: input your swimming pool s characteristics. NB: You can at any time view or modify the characteristics of your swimming pool by visiting Pool settings in the menu. NB: To add a second swimming pool to the app, go to the menu, select the name of active swimming pool and select Add a pool. 4 The application allows:» to have access to the dashboard with comments and outstanding tasks;» to display the four parameters characteristics as well as their trends (displayed as trend arrows);» to receive notifications and alerts;» to display the external temperature;» to add a swimming pool;» to track the history and evolution of a pool s parameters;» the user to change the parameters of the swimming pool;» to calibrate blue;» to take a Bluetooth measure;» to place blue in standby mode (winterisation);» to conduct online diagnostics;» to active blue;» to connect and disconnect from blue.

Installation of blue A. How to start up blue? 1. 2. In the app menu, select blue settings and select Add a pool. Insert the code (KEY), which can be found on the back of the quick start guide or on the base of the blue. To start the blue it must first be activated. The top of the blue is shape like a wave. Place the trough of the wave towards yourself and shake vigorously. Two tones are sounded when the initial activation is successful. 3. 4. Press ok to finalize the activation process. blue is linked to your account and permanently linked to Sigfox 2 network. Place blue upright on the storage cap and unscrew it. 5 5. Empty the storage cap and rinse in clean water before returning it to the case. 2 Sigfox is a telecommunications network specialised in the Internet of Things. It is a low-speed, low energy cellular network that does not interfere with domestic Wi-Fi. You can check if your swimming pool is covered by the Sigfox network by visiting www.sigfox.com/coverage. Blue uses Sigfox to transfer data to your smartphone.

6. Rinse the probe in clean water and place the usage cap in the housing. 7. Place blue in the swimming pool:» In the pool: Allow blue to float free in the pool. You can secure it to the side if necessary by connecting blue to a fixing point on the pool with a cord, which can be easily attached via the ring located on the body of the blue.» In the cover storage area: If your pool is equipped with a retractable protective cover, we recommend you place the blue in the integral cover storage area. 6 B. Notes NB: Ensure that the blue floats vertically and that the head is clear of the water to allow correct communications with the device.» Do not leave blue s sensors exposed to the air for more than an hour.» If you forget to place blue back in the pool, you will be alerted via a notification that it needs to be put back in a wet environment.» The Sigfox network connects automatically and will send the first measurements after an hour. Subsequently it will continue to send Sigfox measurements at regular intervals.» blue s sensor may take a few hours to stabilise its parameters after it is first placed in the swimming pool.» If your region is not covered by Sigfox, blue does work using Bluetooth. In this case, you will need to take daily measurements using Bluetooth so that blue can do its job as an analyser. Ensure you watch the blue start up video available on www.riiotlabs.com (help).

Maintenance A. Calibration NB: blue does not need calibrating on first use. 1. Activate the Internet (Wi-Fi or 4G) and Bluetooth on your smartphone. NB: Remain in proximity to your blue throughout the calibration process. 2. 3. 4. On the dashboard, select blue settings. A message will appear at the top of the screen when the blue is detected. Select Calibrate blue. Remove blue from the water, pull out the usage cap and rinse the probe in clean water. 7 5. 6. Rinse the storage cap with clean water and wipe it clean. Place a ph4 solution in the storage cap and screw it to the blue. Now press Validate. At the top the screen you will see the progression of the measurements. Once the ph4 measurement is complete, unscrew the storage cap from the blue and rinse the probe. Empty 3, rinse 4 and wipe clean the storage cap. 3 Never reuse the calibration products. They are not designed for multiple use. 4 Always clean the probe and storage cap with clean water after calibration to avoid cross contamination of calibration solutions.

7. Place a ph7 solution in the storage cap and screw it to the blue. Now press Validate. At the top the screen you will see the progression of the measurements. Once the ph7 measurement is complete, unscrew the storage cap from the blue and rinse the probe. Empty, rinse and wipe clean the storage cap. 8. 9. Validate the calibration. Replace the usage cap and place blue back into the swimming pool. 8 NB: For best results during calibration use Riiot Lab products. B. Replacing the blue body The body of the blue (probe + battery) will need replacing as a maximum every two years 5. For further details contact your supplier. To ensure the maximum life of your blue:» Put blue into standby mode during winter or when the swimming pool is not in use for protracted periods to conserve battery life (see C below).» The probe should be kept in a wet environment when ever possible. If you have to remove blue from the pool for more than an hour, it is highly advised that blue is correctly secured in the storage cap in KCI (saturated potassium chloride), ph4 solution, or as a last resort, in water from the swimming pool. 5 For standard use and correct storage, the life expectancy of the equipment may vary between 1 and 2 years.

C. Putting blue into standby mode during winter or for storage Winterisation: 1. Activate the Internet (Wi-Fi or 4G) and Bluetooth on your smartphone. NB: Remain in proximity to your blue throughout the standby process 2. 3. From the app menu select blue settings and press Put blue in standby mode. Remove blue from the water. Remove the usage cap. 4. Rinse the storage cap with clean water and wipe it clean. Place KCI 6 (saturated potassium chloride) or ph4 solution in the storage cap and screw it to the blue. 9 5. Validate the standby mode and store blue in a frost free environment. Storage: If you have to remove blue from the pool for more than an hour, correctly secure blue in the storage cap in KCI (saturated potassium chloride), ph4 solution, or as a last resort, in water from the swimming pool. The probe must not be left dry. 6 Residual KCl left in the storage tube can cause the formation of salt crystals where the storage cap joins the equipment. This does not risk damage to the blue and be clean simply by using clean water.

D. Activating blue after winterisation 1. 2. On the dashboard, press blue is in standby See Installation at point 2 above Technical characteristics» Weight: 704 g» Protection Standard: IPX-8» Sensors and measurements: ph: - Range: 0 to 14 - Accuracy: ± 0.1 - Resolution: 0.1 Temperature (water): - Range: 5 to 40 C - Accuracy: ± 0.2 C - Resolution: 0.1 C Redox/ORP (active chlorine): - Range: 0 to 999 mv - Accuracy: ± 20mV - Resolution: 1mV Conductivity: - Range: 0 to 20.000 μs/cm - Accuracy: ± 5 % - Resolution: 1uS/cm» Connectivity: Sigfox, Bluetooth Low Energy (BLE)» Power Supply: 2 x Lithium batteries (Thionyl Chloride).» Nominal Voltage: 7.2 V» Operating System: ios, Android (4.0 Bluetooth, Android 4.3 and ios 9.0)» Languages: English, French, Spanish, Dutch, German, Italian, Portuguese. General information A. Guarantees 10» Product Guarantee: 24 months.» Consumables Guarantee (probe, battery): 12 months.

B. How to recycle this product This symbol indicates that this product must be disposed of in accordance with applicable legal requirements and separated from domestic waste. At the end of the products life it must be taken to an appropriate recycling point. Recycling your product will help protect the stocks of raw materials and guarantee that all guidelines relative to health and safety, and environmental protection are respected. C. Registered Trademark Riiot Labs and blue as well as their respective logos are trademarks which have been filed or registered by Riiot Labs S.A. The Bluetooth trademark and logo is registered and owned by Bluetooth SIG, Inc. and they are used under license by Riiot Labs. AppStore is a service mark of Apple. Inc. registered in the United States and in other countries. ios is a registered trademark belonging to Cisco in the United States and in other countries, used under license. Google PIay and Android are trademarks of Google Inc. All the other trademarks and registered trademarks mentioned in this document are protected by Copyright and are the property of by their respective owners. 11 D. Declaration of conformity EC Declaration of Conformity Document Number: We, the undersigned, Manufacturer or representative: Riiot Labs S.A. Address: Rue du bois saint jean, 16 4102 Ougrée Country: Belgique Phone number: +32 4 332 33 23 E-mail: info@riiotlabs.com Designated product, Description: Brand name or trade mark: Identification / Designation: blue by Riiot Riiot Labs Smart pool analyser

Certify and declare under our sole responsibility that the designated product is in conformity with the essential requirements and provisions of the following European Directives: Directive 2014/30/EU of the European Parliament and of the Council of 26 February 2014 on the harmonisation of the laws of the Member States relating to electromagnetic compatibility (EMC). The conformity of the designated product(s) with the provisions of this European Directive is given by the compliance with the following European Standard(s): Directive 2014/53/EU of the European Parliament and of the Council of 16 April 2014 on the harmonisation of the laws of the Member States relating to the making available on the market of radio equipment (RED). The conformity of the designated product(s) with the provisions of this European Directive is given by the compliance with the following European Standard(s):» ETSI EN 300 328 V1.9.1 (Essential requirements of article 3.2)» ETSI EN 300 489-1 V1.9.2 / ETSI EN 301 489-17 V2.2.1 / (Essential requirements of article 3.1b))» ETSI EN 300489-3 V1.6.1 / EN 61326-1 (2013)» EN 62311 (2008) (Essential requirements of article 3.1a))» EN 61010-1 (2010) (Essential requirements of article 3.1a)) Directive 2014/35/EU of the European Parliament and of the Council of 26 February 2014 on the harmonization of the laws of the Member States relating to the making available on the market of electrical equipment designed for use within certain voltage limits (Low voltage directive) The conformity of the designated product(s) with the provisions of this European Directive is given by the compliance with the following European Standard(s): 12 Directive 2009/125/EC of the European Parliament and of the Council of 21 October 2009 establishing a framework for the setting of ecodesign requirements for energy-related products (Ecodesign / ERP directive) Directive 2011/65/EU of the European Parliament and of the Council of 8 June 2011 on the restriction of the use of certain hazardous substances (ROHS) in electrical and electronic equipment. Directive 2012/19/EU of the European Parliament and of the Council of 4 July 2012 on waste electrical and electronic equipment (WEEE) Name and position of person binding the manufacturer or his authorised representative Mr. Julien Delarbre Address: Rue du bois saint jean 4102 Ougrée - BELGIUM Signature: www.riiotlabs.com 16, Rue Bois Saint-Jean 4102 Seraing, Belgium