Domiciliary Oxygen Switch. Instructions for Use

Similar documents
Oxygen Dialflow Meter. Instructions for Use

Micro Dial-Flowmeter. Instructions for Use

Oxygen Dialflow Meter. Instructions for Use

Dialflow Regulator. Instructions for Use

Pressure Regulators. Instructions for Use

Pressure Regulator. Instructions for Use

Oxygen Demand Valve. Instructions for Use

Firesafe Flowmeter. Instructions for Use

Analgesic Demand Valve. Instructions for Use

USER MANUAL FLOW SELECTOR PM1000 SAVE THESE INSTRUCTIONS. Federal (USA) law restricts this device to sale by or on the order of a physician.

Rev. B. Operating Instructions

Home Oxygen Products. > Innovation > Quality > Safety

Service Manual. Dial Flow Regulators

ACRYLIC FLOW METERS 0-30, 0-70 & LPM

U S E R M A N U A L AIR FLOWMETER. MODELS: 1MFA2001 (shown) 1MFA9001 CAUTION. ISO Certified

Service Manual. Regulators for Medical Gases

USER MANUAL SAVE THESE INSTRUCTIONS. For the most current manual revision, please visit our Website:

Table of Contents. Operating Instructions. Resource v.2 Conserving Regulator

FLOWMETER MODELS: 1MFA, 4MFA, 6MFA and 8MFA Series SAVE THESE INSTRUCTIONS

MAINTENANCE PROCEDURE FOR X 650

Auto-Rewind Hose Reels INSTRUCTION MANUAL FOR OXY-LPG MODEL

Peninsula Dental Social Enterprise (PDSE)

U S E R M A N U A L CAUTION. SAVE THESE INSTRUCTIONS Federal (USA) law restricts this device to sale by or on the order of a physician.

U S E R M A N U A L. (CGA 870 Connection)

Compact Triple Cabinet Outlet Station Model Installation and Operating Instructions

BlenderBuddy 2. Operating Manual & Instructions For Use ENGLISH R233M01 REV. A

NeoNatalie Resuscitator Oxygen kit

CLEMENTS. ANA Oxygen Regulator with Yoke Connector. User Manual. Manual No. ANA Issue 1

MEDICAL REGULATOR RANGE (MEDIREG RANGE)

USER MANUAL Series (CGA 870 Connections) SAVE THESE INSTRUCTIONS

Compact Triple Cabinet Outlet Station Model B Installation and Operating Instructions

DFB FLOW METERS (DESIGNED FOR BLENDERS, DUAL TAPER)

Theatre Control Panel. Instructions for Use. January 2017 ASF-29 (1)

NeoNatalie Resuscitator Oxygen kit

USER MANUAL SAVE THESE INSTRUCTIONS. 300 Held Drive Tel: (+001) Northampton, PA USA Fax: (+001) ISO Certified

PRO SINK -R 1 and 2. Dilution system CONTENTS

Oxygen Therapy Devices

SERIES-O REGULATOR. Instructions for use

USER MANUAL Series (Threaded Connections) SAVE THESE INSTRUCTIONS

U S E R M A N U A L. Model: PM4300 Series SAVE THESE INSTRUCTIONS

Oxygen Delivery Systems:

BRITISH COMPRESSED GASES ASSOCIATION Registered office: 4a Mallard Way, Pride Park, Derby, UK. DE24 8GX Company Number: 71798, England

Presence PR, PRC & PRE

PRESSURE REGULATORS AND FLOWMETERS, ALL MEDICAL GASES

AUTOMATIC GAS MANIFOLDS

HELiOSTM Plus & Marathon

FLOWMETER UNITS FLOWMETER DEVICES, BY-PASS SYSTEMS

CS150 CAP STAPLER OWNER S MANUAL

DRAFT U S E R M A N U A L CAUTION. Model: 19MFA1001 Series. Federal (USA) law restricts this device to sale by or on the order of a physician.

Complex Care Hub Manual: Oxygen Therapy

MANUAL GAS MANIFOLDS

Budget Range Operators Handbook

Med Aire Alternating Pressure Pump and Pad System

AUTOVENT 4000 VENTILATOR

Instructions for Use. OptiLife Nasal Lab Mask

Technical Specification

Specialists in HTM Medical Gas Pipeline Equipment AVSU/Module Operating and Maintenance Instructions

COMPACT TRIPLE WALL OUTLET STATION MODEL INSTALLATION AND OPERATING INSTRUCTIONS

OC4000 USER'S GUIDE I O OXYGEN CONCENTRATOR FOR VETERINARY USE ONLY. by Supera Anesthesia Innovations GLOSSARY OF SYMBOLS. : ON (power switched on)

! WARNING! IMPORTANT HPA AIR TANK SAFETY INSTRUCTION AND GUIDELINES ! WARNING! IMPORTANT SAFETY INSTRUCTION AND GUIDELINES

EasyFit Lite Nasal Mask, Silicone. Nasal Mask. EasyFit Lite Nasal Mask. Device Description and Instructions for Use. Caution:

AREA VALVE SERVICE UNITS

Equinox II USER MANUAL NITROUS OXIDE/ OXYGEN 50%/50% ADMINISTRATION SYSTEM (01EQ7000E) DEMAND VALVE (01EQ7001E) O-TWO MEDICAL TECHNOLOGIES INC.

Sample Concentrator SBH CONC/1 Instructions for use

Hand lever valves VHER

U S E R M A N U A L CAUTION. Models: 19MFA Series. Federal (USA) law restricts this device to sale by or on the order of a physician.

RIX COMPRESSORS. MICROBOOST Owner s Manual CONFIGURATION A MB-115 MB-230. November 21, 2002 APPLICABILITY [ A]

User manual. ZX trolley.

LRS(H)4 Pressure-Reducing Regulator User Manual

Installation Instructions

Medical oxygen. LIV IQ Digital therapy device.

Genie Supreme Model 123 Installation & Operation Instructions

Pressure Automated Calibration Equipment

AND OPERATION INSTRUCTIONS

SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER

12S 1st Stage. -Maintenance Procedure-

O-Two Self-Study Guide. Equinox Relieve

Analgesic and Oxygen Demand Valve. Service Manual

Companion 5 TM. Oxygen Concentrator. User Manual

BS ml Bottle Sampling Unit

Equinox II USER MANUAL NITROUS OXIDE/ OXYGEN 50%/50% USER ADMINISTRATION SYSTEM 01EQ7000E DEMAND VALVE 01EQ7001E TABLE OF CONTENTS

OC4000 USER'S GUIDE I O OXYGEN CONCENTRATORS OXYGEN CONCENTRATOR FOR VETERINARY USE ONLY GLOSSARY OF SYMBOLS. : ON (power switched on)

Blendox AII5000F Inhalation Antalgic System. User s Manual :SP-Y Series No. Version :A1. Date of Review:

BOC: Living healthcare. Manual. LIV IQ BOC Integrated Valve with digital display portable delivery system for Medical Oxygen. BOC: Living healthcare

RB70 Automatic Diluent Valve Maintenance Manual. Version 1.1 November 2006 Written by Tino de Rijk. Page 1 of 23

Assembly Drawing: W-311B-A01, or as applicable Parts List: W-311B-A01-1, or as applicable Special Tools: , , &

Mark 5 Nuvo(OCSI) Lite

VENTI-O 2 plus. O 2 switching valve for: VENTImotion from serial number 4000 VENTIlogic from serial number 4000 VENTImotion 2

3-Way Pressure-Reducing Cartridge, Size 2 4

REL-510H WARNING NOTICE 12 TON SINGLE ACTING REMOTE HYDRAULIC CRIMPING HEAD

Before using or working with the Grab n Go Heliox system, please read and understand the usage and safety instructions provided in this booklet.

Installation and Maintenance Manual. Compact Medical Gas Outlets

INSTALLATION INSTRUCTIONS MANUAL ON/OFF SAFETY VALVE/PILOT KIT MODEL GA9050A-1 (F0235)

AIR/OXYGEN BLENDER INSTRUCTION MANUAL

APC Pressure Reducer with Sensor

INTEGRA E-Z INSTRUCTION MANUAL

General Safety Information

AIR DISTRIBUTOR. PART NUMBER (Including, but not inclusive) AD28483-_ALB, AD28563-_ALB, AD36097-_ALB, AD36098-_ALB, AD28485-_ALB

ATI Skills Modules Checklist for Oxygen Therapy

Basic Pneumatics. Module 8: Pressure control valves. Academic Services PREPARED BY. April 2012

Transcription:

Domiciliary Oxygen Switch Instructions for Use 702-0041.11 July 2017

1. Symbols Warning! Caution! Indicates a potentially hazardous situation which, if not avoided, could result in personal injury to the user or others Indicates a potentially hazardous situation which, if not avoided, could result in damage to the equipment or property Attention, consult accompanying documents 0120 CE Marked to Medical Device Directive 93/42/EEC as amended by directive 2007/47/CE Expiry date No smoking Manufacturer details 1304X12345 YYMM Date of manufacture identification 2. Warnings 2.1. Warnings! Read through this entire instruction manual before using or showing other show to use a Domiciliary Oxygen Switch. As with all medical equipment, attempting to use this device without a thorough understanding of its operation may result in patient or user injury. This device is intended for use with oxygen concentrators with low static operating pressures not exceeding those stated in the Specification. It must not be used for other applications. Oxygen is not flammable; however an oxygen enriched atmosphere will drastically increase the rate and severity of combustion. Oil and/or grease in the presence of an oxygen enriched atmosphere will become highly combustible. Oxygen must never be allowed to contact oil, grease or other hydrocarbon or petrochemical based substances. This device offers an impedance to flow. Do not attempt to use this device to deliver flows exceeding those given in the Specification. Only appropriately trained personnel may install this device. Never administer oxygen while smoking or when near an open flame. The Domiciliary Oxygen Switch offers no protection in the event of a fire in the oxygen tubing travelling back towards the switch. Where the risk analysis on the installation

indicates a fire risk, a suitable Firesafe Cannula Valve (BPR Part No. 827-0001) should be fitted on each line. Ensure switch is secure prior to use. Bubble humidifiers must not be fitted upstream of this Domiciliary Oxygen Switch. If a bubble humidifier is used downstream it must be fitted at a lower height than this switch. See Fitting Instructions in section 4 for further details. Do not submerge the device in any fluid. Ensure that no fluid is allowed to enter the switch inlet ports. Fully engage the control knob onto the switch shaft before attempting to move the switch from one position to another. Changing the switch position without the control knob fully engaged may lead to incorrect orientation of the switch shaft and output ports, which may make the switch inoperable. 3. Functional Description 3.1. Intended Use The Domiciliary Oxygen Switch enables the flow of oxygen from an oxygen concentrator or similar source to be diverted to one of up to four oxygen outlets in the home. The switch can be configured to operate as a simple ON/OFF switch, a 2-way, 3-way or 4- way + OFF switch by the installer depending upon patient requirements. 3.2. Technical Description The device uses a barrel and housing type arrangement to switch flow to the particular outlet required. O-ring seals eliminate leaks and particular attention has been given to gas pathways to ensure that the switch offers minimal impedance to flow; oxygen concentrators have a low output pressure. A detent system provides positive feedback when switching between different switch positions and also helps to centre the valve and align the gas pathways. Certain features have been added to assist disabled users, especially the visually impaired, including: colour coding of switch positions using contrasting colours, Braille style dimples for switch position recognition, large handle for additional mechanical advantage and ribbed handle grip for better feedback. 4. Fitting Instructions Warning! If a humidifier is installed downstream of the Domiciliary Oxygen Switch there is a risk of water flowing through the switch when the oxygen flow is turned off or diverted to another room. This is caused by pressure inside the humidifier chamber pushing water up the tubing. If backflow is initiated it could siphon the full contents of the humidifier to the switch and it would be discharge from the back of the switch. To prevent backflow of water the humidifier must be installed lower than the Domiciliary Oxygen Switch. The height difference must be more than the back pressure developed by the delivery accessories downstream of the humidifier outlet (tubing, Firesafe Cannula Valve(s), cannula, swivel device etc.) at the highest oxygen flow rate that will be used.

For example, if at the prescribed oxygen flow rate the back pressure between the humidifier outlet and the nasal prongs of the cannula is 3 kpa (31 cm H2O), the Domiciliary Oxygen Switch should be more than 31 cm above the maximum fill level of the humidifier. Screw the switch housing to the wall in the appropriate place. Slotted holes are provided for adjustment. Use No. 8 pan head screws (not provided). Arrange for the input and output hoses to terminate at the switch. Cut the hose to length and connect to the appropriate connector on the switch. Press the hose down into the slot provided. Note: Do not try and fit tubing or a cannula to the long local outlet connector until the switch cover is in place. 3 Remote outlet connectors Input connection Local outlet connector Configure the switch to limit the travel of the control knob according to the number of switch positions that are intended to be used (i.e. the number of rooms that have oxygen outlets). Using a small flat-bladed screwdriver, lift the appropriate limit stop pin (refer illustration below) so that it blocks the channel, all other pins should be pressed down. The colourcoded switch membrane indicates which stop pin has to be raised to enable that colour switch position and disable the next colour switch position. To configure the switch for 4 outlets, leave all stop pins down. The OFF position on the switch can be disabled by lifting the stop pin adjacent to the red marker. Raised stop pin blocks channel and prevents the control knob from moving beyond this point. Use flat-bladed screwdriver to lift the appropriate stop pin.

Fit the appropriate room labels to the switch cover and then fit the correct membrane panel for the number of rooms in which oxygen hose is installed. Configured as: ON/OFF Configured as: 2-Way + OFF Configured as: 3-Way + OFF Configured as: 4-Way + OFF Use snipe or long-nosed pliers to remove the hose breakouts from the side of the switch cover. Fit the switch cover onto the switch body. Fit the control knob and secure with the 4mm button head screw provided. Check that the switch rotates to each of the positions marked on the membrane panel. Note: Ensure that the control knob is fully engaged before turning. Fit the logo label on the switch knob. 4.1. Preparation and Connection Connect a sufficient length of oxygen tubing (not supplied) to the outlet barb. 4.2. Testing Prior to Use When undertaking the functional check on the installed system, ensure that there is oxygen flow at each oxygen outlet.

5. Maintenance 5.1. Interim Inspection The switch is maintenance free for an intended life of 6 years. An expiry date is printed on the device rating label and the switch should not be used after this date. 5.2. Cleaning Clean the device using a damp cloth and mild household detergent. Do not immerse the device in any fluid or allow fluid to enter any of the barb connections. 5.3. Refitting Switches can be reused. When re-installing a switch, check that there are no obvious signs of damage and that the device is clean. A refurbishment kit, comprising a new cover moulding and knob, is available if these parts are considered beyond use. The refurbishment kit can be obtained from your local BPR Medical distributor, details of which can be found at www.bprmedical.com. 6. Specification Specification Resistance to Flow Maximum Flow Maximum Static Operating Pressure Leak Transport and storage temperature Value 0.6 kpa at 2 l/min 2.2 kpa at 4 l/min 8 kpa at 8 l/min 25 kpa at 15 l/min 42 kpa at 20 l/min 20 l/min 200 kpa < 5 ml/min -20 o C to 60 o C (-4 o F to 140 o F) Operating temperature 5 o C to 40 o C (41 o F to 104 o F) Applied Standards BS EN ISO 14971 BS EN 15001 BS EN 13544-2+A1 Medical Devices. Application of risk management to medical devices Anaesthetic and respiratory equipment. Compatibility with oxygen Respiratory Therapy Equipment. Tubing and connectors

7. Parts and Spares List Part Number Description 826-0001 Domiciliary Oxygen Switch (1) - Barb Connection 826-0002 Domiciliary Oxygen Switch - Box of 10 Blank Switches - Barb Connection Spare Parts and Servicing 826-0004 Domiciliary Oxygen - Membrane Panel (ON/OFF Box 20) 826-0005 Domiciliary Oxygen - Membrane Panel (2 Way + OFF Box 20) 826-0006 Domiciliary Oxygen - Membrane Panel (3 Way + OFF Box 20) 826-0007 Domiciliary Oxygen - Membrane Panel (4 Way + OFF Box 20) 826-0023 Screw, Pan Head - Polymate 30 (Pack of 20)

BPR Medical Limited T: +44 (0)1623 628 281 22 Hamilton Way, Mansfield F: +44 (0)1623 628 289 Nottinghamshire cs@bprmedical.com NG18 5BU, United Kingdom www.bprmedical.com