SPECIFICATION. date of manufacture. Intermittent: -20 o C to +50 o C. Pressure Range:

Similar documents
SPECIFICATION. date of manufacture. Intermittent: -20 o C to +50 o C. Pressure Range:

O3 3E 1 F Gas Sensor Module

Phosgene Sensor. Sensoric COCl2 3E 1

Ozone. Sensoric O3 3E 1

Nemoto Sensor Engineering Company Ltd

Nemoto Sensor Engineering Company Ltd

All Sixth Sense cells for toxic gas detection are based on electrochemical principles and can be classified as amperometric fuel cells.

Electrochemical Carbon Monoxide Gas Sensor (Model:ME3-CO) Manual. Version 1.2 Valid from May 1 st 2014

GasSense NDIR User Manual

Electrochemical Sensor

OP08 - Electrochemical 3-Electrode Un-biased Toxic Sensors CONTENTS. Introduction 2. Operating Principles 2. Recommended Circuitry 4.

Sensoric 4-20 ma Transmitter Board Operation Manual

Electrochemical Sensor

ME3-HCL Electrochemical sensor

User Manual. µ-gard MD Electrochemical Carbon Monoxide Transmitter Serial No. MD April, 2011

Operating Instructions

Technical Manual. Sensepoint XCD Gas Detector

User Manual. PolyGard DT V4. Electrochemical Carbon Monoxide Transmitter Serial No. DT December, 2008

USER'S MANUAL HOT-WIRE TYPE GAS SENSOR NAP-100A SERIES ( NET10A(R) ) (For All Combustible Gases)

Operation and Maintenance Manual

Alphasense 4-20 ma transmitters offer convenience and easy maintenance for toxic sensors:

Application Note AN-107

an ISO9001 company TECHNICAL INFORMATION FOR TGS5141 Technical Information for Carbon Monoxide Sensors

an ISO9001 company TECHNICAL INFORMATION FOR SK-25F Technical Information for Figaro Oxygen Sensor SK-25F

M iniature Amplified Pressure Sensors

PRELIMINARY DATASHEET

MEMS VOC Gas Sensor. (Model No.:GM-503A) Manual. Version: 1.0. Valid from: Zhengzhou Winsen Electronics Technology Co.

GasLab SAN-102 Micro Oxygen Monitor User Manual

Technical Data Sheet MF010-O-LC

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

HLM-2000-TX Gas Transmitter User Manual

Operation manual Oxygen sensor

an ISO9001 company TECHNICAL INFORMATION FOR TGS5042 Technical Information for Carbon Monoxide Sensors

GasLab SAN-102 Micro Oxygen Monitor User Manual

Operating Characteristics and Handling Manual for the NAP-55A / NAP-50A Explosive/Flammable Gas Sensor NEMOTO

LK-SX CO 2 +VOC. Application. Security Advice Caution. Notes on Disposal

Datasheet: K-30 ASCII Sensor

User Manual. PolyGard AT-1130 V3. Electrochemical Nitrogen Dioxide Transmitter. July, 2011

Transmitter CS 21 Operation Manual

LK-SX VOC. Application. Security Advice Caution. Notes on Disposal. Combined sensor mixed gas. Data sheet

Series 6517 Katharometers. The ideal equipment for Process Monitoring and Control. Robust no moving parts. Designed for continuous industrial use

Air Check Lite Toxic Gas Monitor

MODEL GT820 OXYGEN SENSOR

Transmitter CS 21 Operation Manual

Operation Manual. Rev. C LPT Low Power Transmitter (Electrochemical Sensor)

MEC OEM. User Manual. Commercial in Confidence

Amplified Middle Pressure Sensors

Calibration Requirements for Direct Reading Confined Space Gas Detectors

HLM-2000-TX Gas Transmitter User Manual

User Manual. µ-gard MA-G Electrochemical Carbon Monoxide Transmitter Serial No. MA0X-00X. May, 2017

User Manual. GPL 3000 e. gas detector

Manual. MEMS Combustible Gas Sensor. Zhengzhou Winsen Electronics Technology Co., Ltd. (Model No.:GM-402B) Version: 1.0. Valid from:

MS54XX Miniature SMD Pressure Sensor

CC Operation Manual Oak Valley Drive, Suite 20, Ann Arbor, Michigan USA fax

HUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation

Appendix D: SOP of INNOVA 1412 Photoacoustic Multi-Gas Monitor. Description and Principle of Operation

Miniature Pressure Sensors

White Paper. Chemical Sensor vs NDIR - Overview: NDIR Technology:

CALIBRATION KIT. Instruction Manual

Mass Flow Controller (MFC) for Gases

PRODUCT CONFORMITY CERTIFICATE

210 Series Transmitter with External Electrochemical Sensor

SX150A. Features. Typical Applications. Description

Filtering Escape Hoods

Continuous gas analysis ULTRAMAT 23 Supplement 2 for Operating Instructions C79000-G52xx- C216-03

This multi-functional device allows the determination of up to six quality parameters with only one measurement:

Standard Operating Procedure for H 2 S and SO 2 Converter

Advanced Calibration Designs, Inc. goacd.com. Certified Calibration Gas Solutions

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße (0) 9402 / (0) 9402 /

Columbus Instruments

JUMO dtrans p30 Pressure Transmitter

Sensepoint XCD. Calibration Guide

Dräger PARAT Escape Hoods

Mass Flow Meter (MFM) for Gases

GG-VL2-NH3 AMMONIA VENT LINE SENSOR. Installation and Operation Manual

Operation Manual. Pro CO O 2 Alarm. Carbon Monoxide and Oxygen Analyzer. Rev

Model B Wire Wet Oxidant Gas Transmitter. 6 Iron Bridge Drive Unit 1 & 2 Gatehead Business Park

Gas monitoring using GASMET FTIR

DF-310E PROCESS ANALYSERS APPLICATIONS FEATURES

AMS 6916 Board mount pressure sensor with ratiometric analog output

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter

All P-Types, Trace Oxygen Sensors

GASGUARD VENT LINE3 Ammonia Sensor OPERATING & INSTALLATION MANUAL

Title: Standard Operating Procedure for Measurement of Ethylene (C 2 H 4 ) in Ambient Air by Reduced Gas Detection (RGD)

MS52XX-C&T SMD Pressure Sensor

MS54XX Miniature SMD Pressure Sensor

ASDX Series Silicon Pressure Sensors

D-Opto Dissolved Oxygen Sensor Operation Manual for the D-Opto 4-20mA

A Journal of Practical and Useful Vacuum Technology. By Phil Danielson

AUK Environmental Sensor. Determining the refractive index of the air. AUK Environmental Sensor

TH-1800-T TRX-700-CNG Converter

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)

Handi+ OPERATING MANUAL & INSTRUCTIONS FOR USE. R218P15 Industrial. R218M15 Rev. D

KERN EG/EW Version /02

9700 Transmitter Submersible hydrostatic level transmitter

MS54XX Miniature SMD Pressure Sensor

P9000 DESCRIPTION. For parts requiring RoHS compliance, please contact factory. P February /6

HUMOR 20 HUMOR 20. High-precision Humidity Calibrator. Water T, p1

Continuous Gas Analysis In situ laser gas analyzers TÜV and MCERTS add-on for LDS 6 operating instructions Compact Operating Instructions

Technical Data for Alicat MS Series Mass Flow Meters

Transcription:

The ECO-Sure X is a long life, high quality, cost effective 2-electrode electromechanical cell designed for the detection of Carbon Monoxide CO in a range of applications but particularly for domestic/residential Carbon Monoxide detection, industrial fire detection and ventilation control. The X version offers a 10 year warranted lifetime. This sensor is renowned worldwide for its long lifetime and stable performance. The ECO-Sure (2e) is a recognised component under UL2075. SPECIFICATION ECO-SURE 2112B3001 50 na/ppm X R824200 121122 CAUTION CONTAINS ACID MADE IN THE UK All measurements were taken at 20 o C and 50% rh at 1atm unless otherwise indicated. The performance data detailed in this document refer to new sensors. With the exception of items marked * the stated parameters have been verified under the UL component recognition programme. Note: PCB sockets are recommended for the sensor pin connection. Soldering or using glue with the sensor should be avoided and will invalidate warranty. Operating Principle: Gas Detected: Measurement Range: Maximum Overload: Expected Operating Life*: Sensitivity: Temperature Range*: Pressure Range: 2-electrode electrochemical Carbon Monoxide CO 0 500 ppm 1,000 ppm > 10 years in normal use from date of manufacture 40 60 na per ppm Continuous: -10 o C to +50 o C Intermittent: -20 o C to +50 o C 1atm+10% Humidity Range* (non-condensing): Continuous: 15-90% Intermittent: 0-99% Response Time (T90): Baseline Offset (clean air): Zero Shift* (-10 C to +50 C): Long Term Output Drift: < 30 seconds Repeatability: < + 5% -2 to 4 ppm equivalent < +10 ppm equivalent < 5% per annum Linearity: Within + 5% Recommended Load Resistor: 5 Ω Bias Voltage: Intrinsic Safety Data* Not required Maximum at 1,000ppm: 0.1mA Maximum o/c Voltage: 1.3V Maximum s/c Current: < 1.0A

Physical Specification Weight: Orientation: 5g (approx) Any Housing Material: Noryl N110 Storage Life: 6 months in original sealed container Storage Conditions: +10 o C to +30 o C Warranty Period: 10 years from date of despatch Part Number: 2112B3001 Diameter of pins: 1.55mm Recommended sockets: Wearns Cambion # 450-3326-01. Note: PCB sockets are recommended for the sensor pin connection. Soldering or using glue with the sensor should be avoided and will invalidate warranty. DATA MATRIX SPECIFICATION All measurements were taken at 20 o C and 50% rh at 1atm unless otherwise indicated. The performance data detailed in this document refer to new sensors. With the exception of items marked * the stated parameters have been verified under the UL component recognition programme. ECO-SURE 2112B3001 50 na/ppm X R824200 121122 CAUTION CONTAINS ACID MADE IN THE UK DataMatrix Format: 28 CHARACTERS Data contained in Data Matrix code: 28 character encrypted number with gas type, sensor serial number, part number, date code (YYMMDD) and sensitivity in na/ppm. Scanning recommendations: In order to achieve a reliable read rate, the installation of a fixed scanning device is recommended, such as a fixed scanner from www.datalogic.com. The scanner should be set to dot matrix. A white ring light should be positioned above the cell to be scanned in preference to the scanners inbuilt light source. A hand held scanner can be used but a reduction in read rate may be experienced. Encryption and software licence: Data contained in the Data Matrix code is encrypted. Encryption software and user licence are required to convert the data.

Note: Temperature coefficients and cross- sensitivity are not verified under the UL component recognition programme POISONING Gas sensors are designed for operation in a wide range of environments and harsh conditions. However, it is important that exposure to high concentration of solvent vapours is avoided, during storage, fitting into instruments and in operation. When using sensors with printed circuit boards (pcbs), degreasing agents should be used before the sensor is fitted. Do not glue directly on or near the sensor, as the solvent may cause crazing of the plastic.

CROSS SENSITIVITY Whilst the ECO-Sure is designed to be highly specific to the gas it is intended to measure, it will still respond to some degree to various gases. The table below is not exclusive and other gases not included in the table may still cause a sensor to react. The cross-sensitivity values quoted are based on tests conducted on a small number of sensors. They are intended to indicate sensor response to gases other than the target gas. Sensors may behave differently with changes in ambient conditions and any batch may show significant variation from the values quoted. The figures in this table are typical values and should not be used as a basis for cross calibration. Cross sensitivities may not be linear and should not be scaled. For some cross interference, break through will occur if gas is applied for a longer time period. Gas Concentration Used (ppm) Exposure Time (mins) Reading (ppm CO) Carbon Monoxide CO 100 5 100 Hydrogen Sulphide H2S 25 5 0 Sulphur Dioxide SO2 50 600 <0.5 Nitrogen Dioxide NO2 50 900-1 Nitric Oxide NO 50 5 8 Chlorine Cl2 2 5 0 Hydrogen H2 100 5 20 Carbon Dioxide CO2 5000 5 0 Ammonia NH3 100 5 0 Ethanol C2H5OH 2000 30 5 Iso-Propanol 200 120 0 Acetone 1000 5 0 Acetylene 40 5 80

OPTIONS & ACCESSORIES Standard version ECO-Sure (2e) CO sensor with 4-20mA transmitter (with TÜV approval according to VDI 2053 systems). Part no: 2112B1005. Standard measuring range: 0-300ppm. Optional measuring range: 0-500ppm. Installation kit. Part no: 2112B1022. Test/calibration gas cap. Part no: 2112B1010. Gas Measuring System. Standard version ECO-Sure sensor, 4-20mA transmitter and installation kit provided as a complete unit in aluminium housing. Part no: 2112B1013. Figure 2. Gas Measuring System Standard version ECO-Sure sensor with 4-20mA transmitter and installation kit, provided as a complete unit, fitted into aluminium housing. Part no. 2112B1013. Standard measuring range: 0-300ppm CO. Optional measuring range: 0-500ppm CO. Figure 1. Standard version ECO-Sure CO sensor + 4-20mA transmitter Part no. 2112B1005 (with TÜV approval according to VDI 2053 systems) Figure 3. Test/calibration gas cap Part no. 2112B1010 By the nature of the technology used, any sensor can potentially fail to meet specification without warning. Euro-Gas makes every effort to ensure reliability of all sensors but where life safety is a performance requirement of the product and, where practical, Euro-Gas recommends that all gas sensors and instruments using sensors are checked for response to gas before use. The data contained in this document is believed to be accurate and reliable. The data given is for guidance only. Euro-Gas Management Services Ltd accepts no liability for any consequential losses, injury or damage resulting from the use of this datasheet or the information contained in it. Customers should test the sensors under their own conditions to ensure that the sensors are suitable for their own requirements and in accordance with the plans and circumstances of the specific project and any standards/regulations pertaining to the country in which the sensors will be utilised. Performance characteristics on this data sheet outline the performance of newly supplied sensors. Output signal can drift below the lower limit over time.this datasheet is not intended to form the basis of a contract and in the interest of product improvement, Euro-Gas reserves the right to alter design features and specifications without notice. 09/13