SAUTER FK Version /2016 GB

Similar documents
KERN CM Version /2004

Operating Manual Body fat balance

DFX II Series. Digital Force Gauge

KERN EG/EW Version /02

American Weigh Scales, Inc. BLADE Series D i g i t a l P o c k e t S c a l e BLADE-550. User Manual BLADE-400 BLADE-1000

American Weigh Scales, Inc. LB User Manual

Operating manual for the pressure transducer unit CCS 1000

Pneumatic high-pressure controller Model CPC7000

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

Pneumator. Testo Industrial Services More assurance, better service. Pressure calibrator and measuring instrument.

Technical Information Conducal CLY421

Pneumatic high-pressure controller Model CPC7000

PTG100 Precision Test Gauge

Digital pressure gauge Model CPG500

Digital pressure gauge Model CPG500

Compiled by: B Beard. Approved by: SH Carstens. Description of requirements and procedures for compact provers to be used as verification standards.

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

Manual Weighingblock VB2 series and Uniscale

Digital Melting Point Apparatus

JOLLY2. Installation user s manual. 6 different operating modes selectable. version 3.3. DATA TO BE FILLED OUT BY THE INSTALLER (Page 1)

FPG8601 Force Balanced Piston Gauge

All Purpose AP-Series Operation Manual

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

DK48 - DK800. Quick Start. Variable area flowmeter

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

PM105 PRESSURE METER USER S MANUAL

Operating instructions Installation instructions To be kept in the vehicle!

We measure it. For gas and water installers. testo hpa. bar

Electronic gas volume corrector model DGVC-04

High-speed pressure sensor Model CPT6140

Hand-held pressure calibrator with integrated pump Model CPH6600

DM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

Columbus Instruments

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05

OxyScan Graphic. Operating Instructions. UMS Micro-oxygen sensor 501. Microprocessor instrument

Heavy Duty Dissolved Oxygen Meter

Precision pressure sensor Basic version Model CPT6020

DPC-30 DPC-100. Reference Manual

Operating manual Analogue Brix Refractometer

Dissolved Oxygen/Temp Waterproof Tester

Operation manual Level sensor DC-LS-50 Operation Manual Level Sensor DC-LS-50

Adam Equipment. DENSITY DETERMINATION KIT for AAA, ADA and ADP SERIES BALANCES OPERATOR S MANUAL

Test pumps. Pressure sources. Good reasons for proper and reliable calibration

Bante820 Portable Dissolved Oxygen Meter Instruction Manual

Bante810 Benchtop Dissolved Oxygen Meter Instruction Manual

MANUAL KPS Pressure Control Valve

ELE INTERNATIONAL COMPRESSION TESTER Standard Operating Procedure

User Manual. GPL 3000 e. gas detector

KERN YDB-03 Version /2015 GB

CÜBE. User Manual. American Weigh Scales. CUBE-100 (100g x 0.01g) CUBE-650 (650g x 0.1g)

EPSILON. User Manual. EP-5KG (5000g x 1g) Copyright 2011 American Weigh Scales, Inc. All rights reserved. Rev. 1.0

MODEL 9875 STADIUM BASEBALL SCOREBOARD. Instruction Manual

Digital Pressure Gauge Main features: Data Sheet: BIT02B.417.R6.EN COVER on request

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE

Operating manual Analogue refractometer

BCM-Series. User Manual. American Weigh Scales. BCM-100 (100g x 0.01g) BCM-650 (650g x 0.1g)

SPECIFICATIONS APCEPH1

Manual Refractometer PCE-ALK

Alcotest Breath Alcohol Screening Device. Operator Instructions for Use. ST _sw.eps

OEM Manual MODEL 2305 ECONOMICAL DIGITAL SINGLE CYLINDER SCALE

MS-500. User Manual. MS-500 (500g x 0.1g) Copyright 2010 Fast Weigh Scales All rights reserved. Rev. 2.0

Declaration of Conformity as per Directive 97/23/EC

Simrad GD10P Extended On-site Maintenance

OC Panel High Limit Aquastat Kit, Manual Reset p/n

Digital deadweight tester Model CPD8500

P9000 DESCRIPTION. For parts requiring RoHS compliance, please contact factory. P February /6

Adam Equipment. DENSITY DETERMINATION KIT for AFP, AAA and AAA/LE SERIES BALANCES OPERATOR S MANUAL

100C Air Compressor Kit

Precision digital pressure gauge Model CPG1000

Blanket Tracker. Blanket tracker C83D5EN12

Qi Litre Ultrasonic Cleaner

SIKA Ba_ODWT15_en 05/2018. Operating manual for oil deadweight tester 0.015% accuracy ODWT15

Manual Crane Scale PCE-CS 300

Digital Pressure Gauge Main features: Data Sheet: DFP.418.R4.EN

SonoMeter 30 Energy Meters

Model Description

BI-680 Online Dissolved Oxygen Controller Instruction Manual

OWNER S MANUAL NMB SERIES

Installation & Maintenance Instructions TEC-11N TIMER. Analogue electronic timer 02/09

ANZAI AZ-733VI. Respiratory Gating System. since 1976

P900. P900, Datenblatt Seite 1 DESCRIPTION

159 mm 154 mm. Subject to changes 10/2012

Pressure Calibrators. Series PC..., PM...

Operating instructions for variable area flow meter with needle valve. Model: UVR/UTR

陕西创威科技有限公司. Shaanxi Creat Wit Technology Co., Ltd. Precision pressure calibrator-cwy300 Operating Manual

Digital dead-weight tester Model CPD8500

AXIS. User Manual. American Weigh Scales. AXIS-100 (100g x 0.01g) AXIS-650 (650g x 0.01g)

Pneumatic service kit Model CPG-KITP

Bante821 Portable Dissolved Oxygen Meter Instruction Manual

TEL/jlRE" Introduction. Display Features and Modes. Startup Procedure. Power-Up Procedure. Adjustment Modes

General Accreditation Guidance. User checks and maintenance of laboratory balances

200 PSI COMPRESSORS - MODEL NUMBERS

IMPORTANT SAFETY INSTRUCTIONS

User Manual PTW-DensiX. D / Di/Zi

Operating Instructions. Ball valve fitting according to ZB For pressure transmitter VEGABAR 82. Document ID: 50027

Hydraulic pressure balance Model CPB5800

SPS-5. Rate Computing Scale. Operation Manual

Valve test benches. Systems overview

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

Transcription:

Sauter GmbH Ziegelei 1 D-72336 Balingen E-Mail: info@sauter.eu Tel: +49-[0]7433-9933-199 Fax: +49-[0]7433-9933-149 Internet: www.sauter.eu Instruction Manual Digital Force Gauge SAUTER FK Version 1.4 12/2016 GB PROFESSIONAL MEASURING FK-BA-e-1614

GB SAUTER FK Version 1.4 12/2016 Instruction Manual Digital Force Gauge Thank you for buying a digital SAUTER force gauge. We hope you are pleased with your high quality force gauge with its big functional range. If you have any queries, wishes or helpful suggestions, do not hesitate to call our service number. Summarize: 1 Scope of delivery... 3 2 Working Conditions... 4 3 Electrical power supply... 4 4 Technical data... 4 5 Operation... 4 5.1 Display... 4 5.2 Keyboard units... 4 5.3 Display Return of 180... 5 5.4 Measurements (Track Mode)... 5 5.5 Peak-Hold Function (Peak Mode)... 5 6 Backside Fixing to a test stand... 5 7 Warning notices... 5 8 Adjustment procedure of FK force gauges... 7 2 FK-BA-e-1614

1 Scope of delivery - SAUTER FK - Electrical power supply - Transport case - Standard attachments, as shown below: Extension rod: 90mm Sensor Inside Sensor inside signifies that the measuring cell is inside the housing of the display unit Conditions: Measurement principles: 1. Continuous measurement (Track) 2. Capture of the max. value (Peak Hold) In this mode, the max. value is always captured during several consecutive measurements Dimensions in mm LCD 195 mm 83 m Force sensor M8 thread FK-BA-e-1614 3

2 Working Conditions Working temperature: 10 C to 30 C Humidity: 15% to 80% 3 Electrical power supply - Either by batteries (6 x AA batteries) not rechargeable! Batteries have to be changed if necessary. - or current power supply Using electricity network: - Connection by power adapter cable 4 Technical data - Accuracy: ± 0,5 % of Capacity - Internal test frequency: 1.000 Hz - Overload protection: 200% of max. - Dimensions: L x W x H: 195 x 82 x 35 mm - Net weight: ca. 0.72kg 5 Operation 5.1 Display (4) (3) (1) (1) Measuring Result (2) Measuring Units (3) Measuring Direction (4) Indication of PEAK Mode (2) 5.2 Keyboard units ON / OFF: to switch on, ON has to be pressed for about 1s MAX: To change between Track mode (continuous measurement) and Peak mode (capture of maximum values) 4 FK-BA-e-1614

UNIT: Press shortly to select the desired unit: N, kg, lb, ou ZERO: - Zeros the measurement result (Tare function) - Cleans the peak value (in Peak mode) 5.3 Display Return of 180 When the instrument itself is turned for 180, the display indication will turn automatically. 5.4 Measurements (Track Mode) On the display (1) the continuous force is shown in a defined direction (3) To zero the display, please press ZERO key 5.5 Peak-Hold Function (Peak Mode) To activate please press: MAX key 6 Backside Fixing to a test stand Mounting is possible on all SAUTER test stands by means of 4 x M3 screws. 7 Warning notices Force measurements which are performed in an incorrect way, can lead to serious injuries of living beings and damage of objects. Therefore, trained staff may practice them only. Please avoid that forces are reacting on the force gauge, which are exceeding the instrument s max. load (max). Or if forces are not reacting axially from the force sensor onto the instrument or if high impulse forces are reacting on the force gauge. FK-BA-e-1614 5

Prevent jolts, torsion and oscillation (e.g. by suspending loads aslope) of all kinds, because there is a risk of breakage and in all cases there will be a lack of measurement accuracy. Inappropriate use Do not use the instrument for medical measurements. In the case that small quantities are removed or added to the material to be measured, incorrect measuring results can be displayed, due to the stability compensation in the instrument (such as slowly draining off of liquid from a container suspended at the instrument). Do not leave attached a continuous load. This can damage the measuring unit as well as the parts, relevant to safety. Overload Be sure to prevent overloading the instrument in excess of the stated maximum load (max.), minus any tare weight that may possibly exist. This could damage the instrument (risk of breakage). Attention: - Always make sure that there are no people or objects below the load, which could be injured or damaged! - The instrument is not suitable for weighing people. Do not use it as a baby scale! - The instrument does not comply with the medical product law (MPG). - Never operate the instrument in hazardous locations. The series design is not explosion-proof. - Structural alterations may not be done on the instrument. This can lead to incorrect measuring results, faults concerning safety regulations as well as to destruction of the instrument. - The instrument may only be used in compliance with the described guidelines. - Varying ranges of application or planned use must be approved by SAUTER in writing. Warranty The warranty is not valid under following aspects: Non-observance of our guidelines in the operating instructions Use beyond the specified applications Alterations or opening the device unprofessionally, as well as mechanical damage and damage caused by media or liquids Natural wear out and abrasion 6 FK-BA-e-1614

Inappropriate setting up or electric installation Overload of the measuring equipment Inspection of measuring and testing equipment Within the scope of quality assurance, the metrology features of the instrument and any possible available adjusting weight must be checked at regular intervals. For this purpose, the responsible user must define a suitable interval as well as the nature and scope of this inspection. Information is available on SAUTER home page (www.sauter.eu) concerning the monitoring of instrument test substances and the test weights required for this. Test weights and instruments can be adjusted quickly and reasonably priced in KERN s accredited DAkkS calibration laboratory (return to national normal). IMPORTANT Observe the information in the operating instructions. Please read the instruction manual carefully before the initial operation, even if you already have gained experience with SAUTER instruments. 8 Adjustment procedure of FK force gauges Take care for stable working conditions 1. A short warming up time of approx. 1 minute is recommended for stabilisation. Switch on the FK by pressing ON/OFF button. The instrument is held in vertical, hanging position. FK-BA-e-1614 7

2. As soon as 0 is displayed, press UNIT button and ZERO button at the same time, until CAL appears on the display. 3. Wait a few seconds and display will show the necessary adjustment weight, e.g. 5,000kg for FK 50 or 10,00kg for FK 100. 4. Put the corresponding weight at the loading hook. Avoid trembling and keep still while holding the weight. Hint: hold device with both hands while shoring up your elbows on a table or desk or fix it at a solid object (test stand). 5. Hold position until F appears on the display. In this case remove weight and adjustment is completed. In case of E is displayed - repeat step 1. to 5. until F attests a successful adjustment. 8 FK-BA-e-1614