Routine Testing. SOP Temperature Calibration of Halogen Moisture Analyzer. Applicable for HR / HG / HB / MJ Moisture Analyzers

Similar documents
SmartCal. SmartCal Troubleshooting Checklist

Chemical Industry. School experiments. Weighing. Helper Booklet. Tips and Tricks for Weighing. Natural science laws experience live learn easily

Predicted Dispense Volume vs. Gravimetric Measurement for the MICROLAB 600. November 2010

Operating Instructions METTLER TOLEDO Pipette Check Application for AX and MX/UMX Balances Version 1.xx

10 Steps to Successful Micro-Weighing

Quantos Automated Dosing Solution Preparation Precise concentrations Process compliance Minimize out-of-specs

INFLUENCE OF MEASURING PROCESS AUTOMATION ON UNCERTAINTY OF MASS STANDARD AND WEIGHTS CALIBRATION.

General Accreditation Guidance. User checks and maintenance of laboratory balances

How to Achieve Optimal Weighing Performance

2014 Programme of Training Courses in Measurement & Calibration

Requirements and Methods for Calibration of Equipment in Clinical Laboratories. NK Chan (HKRCBTS) 24 August 2007

CHM Introductory Laboratory Experiment (r17sd) 1/13

MTB Load Cell. Globally Approved for Accuracy and Safety. MTB Load Cell Fully Approved

Relative Humidity Calibration Kit

User-Calibration of Mettler AT200 Analytical Balance

Instruction and Maintenance Manual

News. Semiconductor. Reduces Risk of Contamination. Perspectives in Pure Water Analytics THORNTON

User Manual. Quantos Automated Dosing Liquid Module

OPERATING PROCEDURE. Number: V2. Authors. Approvals

SOP-I-101 Operation and Calibration of the Analytical Balance

Technical Data Sheet MF010-O-LC

8.1 Calibration of gas sensors

Improve Process Reliability

Alcotest Breath Alcohol Screening Device. Operator Instructions for Use. ST _sw.eps

RADWAG Mass Comparators - ETERMA 2013 MASS COMPARATORS

Beamex. Calibration White Paper. Weighing scale calibration - How to calibrate weighing instruments

High Precision Gauge Pressure Indicators

Hand-held pressure calibrator with integrated pump Model CPH6600

CTAG:e43bda4f8e48714fbb aefb192 Certificate of Calibration

WIKA INSTRUMENT CORPORATION

Requirements for the certification of movements and mechanical watches resistant to magnetic fields of 1.5 T ( G)

Hazard Analysis Worksheet STEP #10: UNDERSTAND THE POTENTIAL HAZARD.

User Manual. Robotic Mass Comparator e100

CTAG:b9927e36a4b3f34a9138ce0bb2426b22 Certificate of Calibration

User Manual. Robotic Mass Comparator e5

User Manual. Quantos Automated Dosing Powder Module

METHOD 3A - DETERMINATION OF OXYGEN AND CARBON DIOXIDE CONCENTRATIONS IN EMISSIONS FROM STATIONARY SOURCES (INSTRUMENTAL ANALYZER PROCEDURE)

628 Differential Pressure Decay Leak Tester

Instruction and Maintenance Manual

Verification Of Calibration for Direct-Reading Portable Gas Monitors

Outside Air Nonresidential HVAC Stakeholder Meeting #2 California Statewide Utility Codes and Standards Program

Instruction Sheet. Calibration of Multiple 1720 and FT660 Turbidimeters

Vaisala Pressure, RH & Temp. Transmitter. The instrument was operational upon receipt. The instrument was adjusted and calibrated.

Specific Accreditation Criteria Calibration ISO IEC Annex. Mass and related quantities

BIOGAS COMBUSTION PLANT MAINTENANCE MANUAL

Continuous Gas Analysis In situ laser gas analyzers TÜV and MCERTS add-on for LDS 6 operating instructions Compact Operating Instructions

STD-3-V1M4_1.7.1_AND_ /15/2015 page 1 of 6. TNI Standard. EL-V1M4 Sections and September 2015

CALIBRATION CERTIFICATE # 500

BCM-Series. User Manual. American Weigh Scales. BCM-100 (100g x 0.01g) BCM-650 (650g x 0.1g)

Centrifugation: High Speed Floor Centrifuges

AXIS. User Manual. American Weigh Scales. AXIS-100 (100g x 0.01g) AXIS-650 (650g x 0.01g)

Density Determination Kit Instruction Manual

II. MATERIALS REQUIRED FOR PERFORMANCE TESTING

Relative Humidity Calibration Kit

User Manual. Portable Balances PL-E

American Weigh Scales, Inc. LB User Manual

Do Not Print This Page.

CÜBE. User Manual. American Weigh Scales. CUBE-100 (100g x 0.01g) CUBE-650 (650g x 0.1g)

UKAS calibration laboratory 8809 Temperature, pressure and electrical signals calibration guide

TC65M/15M TEMPERATURE CALIBRATOR USER S MANUAL

PRODUCT CONFORMITY CERTIFICATE

Traceable calibration of automatic weighing instruments in dynamic operation

ENVIRONMENTAL AND POLLUTANTS GAS ANALYZERS

Applications Note: Use of "pentane equivalent" calibration gas mixtures

CH2250: Techniques in Laboratory Chemistry. Outline Measuring Mass Measuring Volume Significant figures. Mass Measurement

v /07/17 Page 1 of 18

Chapter Pipette service & maintenance. Pipette specifications according to ISO Repair in the lab or return for service?

CHM 100 / Introductory Laboratory Experiment (r10) 1/11

Oct 1, 2002 LAB MANUAL SPECIFIC GRAVITY & ABSORPTION of FINE AGGREGATE AASHTO Designation T 84 (Mn/DOT Modified)

AMB MOISTURE BALANCE AMB 50, AMB 110 and AMB 310. Operating Manual

Guide No. 2/2009. Design, training and equipment Martin Firlus. Physikalisch Technische Bundesanstalt Braunschweig und Berlin

Advanced Test Equipment Rentals ATEC (2832)

Over 80 years of experience in precision weighing and UniBloc technology

Mr Roger Wood Measurement & Process Group (M&P) Network Strategy National Grid Gas plc Brick Kiln Street Hinckley Leicestershire LE10 0NA

Title: Standard Operating Procedure for Measurement of Ethylene (C 2 H 4 ) in Ambient Air by Reduced Gas Detection (RGD)

PREPARED BY: Marshall K. Cheung, Ph.D., Laboratory Director. REVISED BY: Marshall K. Cheung, Ph.D., Laboratory Director

Adam Equipment. DENSITY DETERMINATION KIT for AAA, ADA and ADP SERIES BALANCES OPERATOR S MANUAL

MILITARY SPECIFICATION POWDER, BLACK

Eliminating Sources of Error in IV Pump Testing

Service ISO17025 explained

GDRP Hints & Tips. How to Achieve the Best Results Day-to-Day Refractive Index Measurement. Hints & Tips. Good Refractometry Practice Brochure

WBEA Standard Operating Procedure

PM105 PRESSURE METER USER S MANUAL

MASSACHUSETTS STATE POLICE CRIME LABORATORY. Certificate of Calibration Procedure for the Alcotest 9510

Generating Calibration Gas Standards

OxyCheq Expedition-X Oxygen Analyzer. Operator s Manual

Density2Go. Hydrometers Pycnometers Digital Hydrometers. 3 Ways to Measure Density Know-How, Hints, and More

Gas mixtures. Individual solutions specifically for your application

Technical Note. Determining the surface tension of liquids by measurements on pendant drops

Transferpette -8/-12

MET-101 Introduction to Metrology

Tiger Select. Instrument User Manual V2.7

Title: Standard Operating Procedure for R&R Environmental Devices Model MFC201 Gas Dilution Calibrator

ISO Vacuum gauges Calibration by direct comparison with a reference gauge

INTERNATIONAL STANDARD

TR Test Report Complementary Testing RKN e1 Container (+5 C) Protection by Insulation Version: 01 Page: 2 (22)

American Weigh Scales, Inc. BLADE Series D i g i t a l P o c k e t S c a l e BLADE-550. User Manual BLADE-400 BLADE-1000

CORESTA Guide N 6. February A User Guideline for the use of balances for cigarettes and cigarette related products

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs.

Light Lab. Reliable Measurements through Regular Calibration. DAkkS

Transcription:

Routine Testing Applicable for HR / HG / HB / MJ Moisture Analyzers

Routine Testing of Moisture Analyzers General For standardized and repeatable temperature calibration or adjustment of a Halogen Moisture Analyzer, the manufacturer s temperature calibration kit must be used ( s Temperature Calibration Kit HA-TCC: Order No. 00214528). The kit contains a black disk which is used to simulate the surface of a sample. The black color provides a reference with maximum radiation absorption which hence has high sensitivity to changes in the system. This is best for achieving high repeatability and reproducibility of the calibration. The temperature of a sample during a measurement depends on its absorption characteristics and therefore may differ from the temperature measured on the black disk. Influencing Factors to be considered for Temperature Calibration The factors described below are potential sources of error which may influence the temperature calibration and could cause deviations in the accuracy, repeatability and reproducibility. It is recommended to avoid or minimize these influences. If they cannot be eliminated, make sure that they are at least the same or similar to those present during routine operation of the Moisture Analyzer. Influences from HR/HG/HB/MJ Halogen Moisture Analyzer The unit must be installed and ready for routine operation Acclimatized to room temperature Left on power for a sufficient period of time (minimum 1 hour) The heating compartment has cooled down (heating has not been used for 1 hour) The heating system is clean and has no damage The reflector is not damaged or dirty (small spots or damages below 2mm diameter are accepted) The temperature sensor is clean The protective glass is clean The draft shield is installed big big 2 of 6

Influences from Temperature Calibration Kit Always store Temperature Calibration Kit in its original box Always use kit with handler Make sure that the temperature is read out correctly 1 dash of the scale represents 2 C Make sure that the needle of the instrument has no hysteresis To avoid, knock gently on the instrument before kit placing it into the instrument for adjustment Make sure that no parallax error is made by placing the eye straight (90 ) above the arrow. Reading from sideways may cause deviations in temperature reading Handle the Temperature Calibration Kit gently and put it back into storage box after cooling down completely Use only a Temperature Calibration Kit with calibration certificate to improve accuracy and assure traceability. Re-calibrate it in regular intervals Any damage, which might have affected the Temperature Calibration Kit, should trigger an immediate re-calibration. s calibration services will give advice on this Do not scratch the surface of the black disc or apply any sticker on the Temperature Calibration Kit Influences from Environment Make sure the environmental temperature is within required range (5 C 40 C) Make sure the temperature calibration is performed at place of use under working conditions (e.g. if unit is running in a safety enclosure, the fan should be on same level and the door of the safety enclosure in the same position, as during routine operation small big 3 of 6

Routine Testing of Moisture Analyzers Influences from Procedure Read out the temperature always after same heating time. Each test point should be read out after 15 minutes heating. That means 100 C after 15 minutes and 160 C after further 15 minutes Use corrected value of temperature reading only. Calculate the deviation from calibration kit certificate into the read out. Calculation scheme: T kit T dev. = T actual T kit = Displayed value of temperature calibration kit T dev. = Kit deviation noted in certificate of temp. calibration kit T actual = Actual temperature To assure traceability, report all calculation steps to the record Calculation Example: T kit T dev. = T actual T kit = Displayed value of temperature calibration kit (e.g. 100 C) T dev. = Kit deviation noted in certificate of temp. calibration kit (e.g. 2 C) T actual = Actual temperature Example: 100 C [ 2 C] = 102 C Calibration Procedure small Preparation Make sure that conditions listed under Influencing Factors to be Considered for Temperature Calibration are respected Make sure that the sensitivity test (if applicable) is performed before the temperature test to avoid long cooling down time Test Procedure Start the test of the heating module according to the description in the operating instructions. HB43/HB43-S, (MJ33, HR73) and HG53 Moisture Analyzers do not have a calibration (test) function only adjustment. To be able to perform a calibration, start an adjustment, note the values and after the last calibration point at 160 C do not confirm the values but abort the adjustment. For HB & MJ simply open the lid, for HR73 & HG53 cancel the adjustment Remove the sample pan and the sample pan holder Place the Temperature Calibration Kit together with the handler Start the temperature calibration / adjustment Wait 15 minutes until the moisture analyzer gives a signal (beep) to read out Read stable value 1 Read value from the temperature gauge at the kit Record value and mark it as displayed value from temp. cal. kit 4 of 6

Calculate correct value by adding or reducing deviation reported in HA-TCC Calibration Certificate (follow calculation scheme noted above) Record the corrected value and mark it as corrected value Key in the corrected value into instrument memory Start next cycle for temp 2 Wait 15 minutes until moisture analyzer gives a signal (beep) to read out Read value from the temperature gauge at the kit Record value and mark it as displayed value from temp. cal. kit Calculate correct value by adding or reducing deviation reported in HA-TCC Calibration Certificate Record the corrected value and mark it as corrected value Key in the corrected value into instrument memory HB, MJ, HR73 & HG53 proceed as follows If values are within tolerance cancel adjustment If Values are out of tolerance, proceed adjustment Note: Every adjustment requires a calibration (after let cooling down the unit) to assure the adjustment was successful. HR83 & HG63 proceed as follows If values are within tolerance, finish calibration If values are out of tolerance, finish calibration and proceed adjustment Repeat calibration after cooling down the system Evaluation Evaluate whether corrected values exceed the defined Warning Limits 1) Evaluate whether the corrected values exceed the defined Control Limits 2) Deviation Warning Limit 1) (where defined) If a warning limit is exceeded, communicate this to the laboratory supervisor or the person responsible for the moisture analyzer HR83 & HG63 Let the moisture analyzer cool down, perform the temperature adjustment, let the moisture analyzer cool down and repeat the calibration HB, MJ, HR73 & HG53 Turn calibration into adjustment by not aborting the adjustment. Let the moisture analyzer cool down and repeat the calibration If a warning limit is still exceeded, report this to the laboratory supervisor or the person responsible for the moisture analyzer. Optionally, contact s service organization for advice Control Limit 2) If a control limit is exceeded, communicate this to the laboratory supervisor or the person responsible of the moisture analyzer Lable the moisture analyzer as out of control limits Contact service organization for support 1) Values within the warning limit require no action. Values between the warning and control limit are within the tolerance but must be kept under surveillance. 2) Values within the control limit, see 1) Values beyond the control limit show that moisture determination process is no longer under control and immediate action is therefore required. 5 of 6

Recommended Warning and Control Limits for Temperature Calibration Moisture Analyzer HR/HG HB/MJ Warning Limit ± 3 C ± 3 C Control Limit ± 5 C ± 5 C Required Temperature Calibration Kit: HR/HG/HB/MJ: certified Temperature Calibration Kit (HA-TCC), Part No.: 00214528 www.mt.com/moisture For more information Mettler-Toledo AG Laboratory & Weighing Technologies CH-8606 Greifensee Tel. +41 44 944 22 11 Fax. +41 44 944 31 70 Subject to technical changes 03/2013 Mettler-Toledo AG Printed in Switzerland 30031481 Global MarCom Switzerland