Installation Instructions

Similar documents
Installation Instructions

Installation Instructions

Installation Instructions

OPERATION MANUAL RTI RHS650 RTI TECHNOLOGIES, INC East Market Street York, PA Manual P/N

Section 3- Repair and Calibration Procedures

Installing ASI Umbilical Delivery Systems

PROPORTIONING VALVE. Model 150 INSTRUCTION MANUAL. March 2017 IMS Company Stafford Road

RecoverXLT Oil-Less Universal Refrigerant Recovery System. (For serial numbers and higher)

UNITY 2. Uni-DAAMS Manual. Version 1.3 (Changes to Section 1.1) March 2010

Dual Electronic Basketball System Owners Manual

3/8" Dr. Air Butterfly Impact Wrench

Gerber Sabre 404 and 408 Installation Instructions

FX134, FX1234, FX3030 Problem and Solutions

MASK INTEGRITY TEST ACCESSORY (MITA) MODEL 8120

Operating Manual. Model 25200B/25202B Refrigerant Recovery Unit. (Not for use in automotive R-134a applications)

Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0)

Model PSI Compressor with 3-Gallon Air Tank 12VDC

B. Assemble the Method-25 sample train with a heated probe/filter.

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP

200 PSI COMPRESSORS - MODEL NUMBERS

RG6000. Refrigerant Recovery Machine. Operating Manual. 99 Washington Street Melrose, MA Phone Toll Free

100C Air Compressor Kit

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

KJ4000 Operating Instructions & Parts Manual NSN

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50 Systems Outfitted with ABM-725 Monitor C O M P A N Y

Misaligned Folds Paper Feed Problems Double Feeds Won t Feed FLYER Won t Run iii

42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only)

Pressure Dump Valve Service Kit for Series 3000 Units

Instructions for Assembly, Installation, and Operation of the Gas Addition Kit Accessory with the CEM Discover Systems

444C DUAL PERFORMANCE VALUE PACK

222 Schwinn Recumbent Exercise Bike Parts List Full Size Hardware Chart Product Illustration Assembly Instructions

Nitrogen Tyre Inflator Owner s Manual

Refrigerant Recovery, Recycling and Recharging Station

IMPORTANT SAFETY INSTRUCTIONS

Advanced Fluid Handling Cart Owner s Manual

with O 2 Controller Instruction Manual

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

Pressure Dump Valve Service Kit for Series 2300 Units

Operation and Maintenance Manual

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

RecoverXL and RecoverXLT Oil-Less Universal Refrigerant Recovery Systems Operation and Maintenance Manual

User Manual MFCS TM -EZ

User Manual GRI- 1500Li

COMPACT TRIPLE WALL OUTLET STATION MODEL INSTALLATION AND OPERATING INSTRUCTIONS

AIR INLINE METAL SHEAR

400C & 450C DUAL PERFORMANCE VALUE PACKS

AC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight

MB-SP Series Solvent Purification System

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

2 in. 18 Gauge Brad Nailer. User manual

ELECTRONIC PLC SERIES Test Benches

OPERATION MANUAL NTF-15

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

PRESSURE TEST PUMP OPERATING & MAINTENANCE INSTRUCTIONS. Model No: PTP100. Part No: GC01/09

Installation and Use Manual

OPERATOR S MANUAL Ar-Gone Weld Gas Analyzer

OPERATION MANUAL BFX-2

INSTRUCTION MANUAL. Gas Salamander

OPERATION MANUAL NTF-60 Plus

XpressFill XF2500 Counter Pressure Filler. Operating Instructions

HPICAL Operation & Data Logging Procedures. Click spacebar to advance through slides 1

Safe Work Instructions For Oxygen Acetylene Equipment

400H HARDMOUNT AIR COMPRESSOR KIT PART NO H HARDMOUNT AIR COMPRESSOR KIT PART NO

Operating Instructions Part No

LUBRICATOR ASSEMBLY AND OPERATING INSTRUCTIONS

INSTALLATION, CARE & USE MANUAL. EMASMB & LMASMB Surface Mount Bottle Filling Stations

Freedom8 ShoeBox Compressor Manual

Shoreline Cantilever Lift 2500lb Capacity Models: (108" inside width) - Part # (120" inside width) - Part #

Heavy Duty Dissolved Oxygen Meter

User Instruction Manual

AIR COMPRESSOR. Failure to follow all instructions as listed below may result in electrical shock, fire, and/or serious personal injury.

MANUAL BE SERIES Test Benches

Basketball Instructions

200 PSI HIGH-FLOW AIR SOURCE KIT

200 PSI FAST-FILL AIR SOURCE KIT

450P AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

Booster Pump PB4-60 Replacement Kits

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

INTENDED USE TECHNICAL SPECIFICATIONS

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

RecoverXLT2-AP Oil-Less Universal Refrigerant Recovery System Operation and Maintenance Manual

STANDARD OPERATING PROCEDURES. Andersen Instruments Federal Reference Method (FRM) Ambient Particulate (PM 10 /PM 2.

Bante810 Benchtop Dissolved Oxygen Meter Instruction Manual

Glove Box Installation Manual

Setup Guide for your HVO Naked Drone

AIR/OVER HYDRAULIC JACK 20 TON

INSTRUCTION MANUAL. January 23, 2003, Revision 0

Bante820 Portable Dissolved Oxygen Meter Instruction Manual

IMPORTANT PLEASE READ BEFORE COMMENCING INSTALLATION

P5513. Users Manual. Pneumatic Comparison Test Pump. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

Operating Instructions Part No

STANDARD OPERATING PROCEDURES DIVISION OF COMPARATIVE MEDICINE UNIVERSITY OF SOUTH FLORIDA

Squeegee Unit for MRS Multi-Recovery System

QUICK START GUIDE TO DRINKING WATER MONITORING

Compact Triple Cabinet Outlet Station Model B Installation and Operating Instructions

450P- RV AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

PCS 340 Core Saturator : 115 Volt : 230 Volt. Instruction Manual

Compact Triple Cabinet Outlet Station Model Installation and Operating Instructions

Superconducting Susceptometer (MPMS-5S) Quantum Design Room 296 (MPMS)

OPERATION MANUAL ID900

Transcription:

SUN ELECTRIC CORPORATION Model: MRC-450 MRC-450-3 MRC-450-6 MRC-450-GR Page: 1 of 5 Installation Instructions INSTALLATION MUST BE PERFORMED BY QUALIFIED SUN PERSONNEL ONLY INSTALLATION OVERVIEW: The Installation Procedures listed are for the MRC-450, (-3) (-6) & (GR). The unit is shipped as a fully assembled unit, with the exception of the items listed in the Parts & Accessories per tester. PLEASE READ THESE INSTRUCTIONS COMPLETELY BEFORE SETTING UP UNIT. THIS UNIT MUST BE PLUGGED IN TO A PROPER AC OUTLET FOR UNIT TO OPERATE CORRECTLY. REFER TO UNIT ID PLATE LOCATED ON BACK OF UNIT. EXTENSION CORDS ARE NOT RECOMMENDED, BUT IF AN EXTENSION CORD MUST BE USED, USE A CORD THAT IS LESS THAN 50 FEET WITH A 16 AWG, OR ABOVE 50 FEET AND LESS THAN 100 WITH A 14 AWG. USE STANDARD REFRIGERANT HANDLING SAFETY PROCEDURES WHEN PERFORMING INSTALLATION ALWAYS WEAR SAFETY GOGGLES, DON T SPILL OR TOUCH LIQUID REFRIGERANT, AVOID FLAMES, AND EXCESSIVE HEAT. USE ONLY IN WELL VENTILATED AREA. REQUIRED TOOLS: ø 7 Crescent ø Screw driver (Flat Blade and Phillips) ø Safety Goggles (0001-5005) ø Refrigerant Oil (Mineral) 0692-2304-01 (Tuesday, June 03, 1997) REV.D

Page 2 of 5 PARTS & ACCESSORIES LIST FOR: PART NUMBER DESCRIPTION MRC-450 (-3) (-6) (-GR) 0119-0337-01 Literature Kit - 1 - - 0119-0349-01 Literature Kit - - - 1 0119-0361-01 Literature Kit - - 1-0119-0363-01 Literature Kit 1 - - - *0400-0036 Washer, Flat, #10 - - - 2 *0403-1541-08 Screw, 10-32 x 1/2 HXSMS - - - 1 *0403-1541-16 Screw, Mach 10-32 x 1 - - - 1 0647-0287-09 Adapter, R-134a, High Service 1 1 1 1 0647-0287-10 Adapter, R-134a, Low Service 1 1 1 1 0671-1018-02 Desiccant Bag 10 10 10 10 0692-1834-01 SEL 1403C Questionnaire 1 1 1 1 0692-2304-01 Installation Instruction 1 1 1 1 *0692-2253-01 Tank Band Installation Instructions 1 1 1 1 0693-2013-01 Video 1 *0710-0032 Tinneman - - - 2 3988-0278-01 Hose Assembly, Yellow, 36, Utility 1 1 1 1 4211-0001-01 Envelope, Clear 1 1 1 1 6001-0197-01 AC Power Cord 1-1 - 6001-0200-01 AC Power Cord - 1-1 6004-0760-01 Cable, Recovery Tank 1 1 1 1 6004-0777-01 Cable Assembly, Temperature Probe 1 1 1 1 7009-2331-03 Recovery Tank Assembly 1 1-1 7009-2418-01 Inline Filter 1 1 1 1 *7012-1568-01 Band, 30lb. Tank - - - 1 ARG04040 O-Ring Repair Kit (For Vehicle Adapter) 1 1 1 1 EAH0001C01A Blue Hose Assembly, 96 1 1 1 1 EAH0001C02A Red Hose Assembly, 96 1 1 1 1 * Part of the Tank Band Kit UNPACKING UNIT AND ACCESSORIES: 1. Cut Straps, and remove top of the carton, top packing, and carton sides. 2. Slide the unit and carton base off the pallet, and split the corners of the base carton. 3. Lean the unit so that one half of the cardboard base can be removed. 4. Lean the unit so the other half of the cardboard base can be removed. 5. Inventory all items using the parts list and inspect for damage. Place the four adapters, Desiccant bags, and the Cap Plugs in the Storage Compartment on the rear of the unit. 6. Place the Literature Kit (0119-0337-01 or 0119-0349-01 or 0119-0361-01 or 0119-0363-010), that includes the User's manual, and O-Ring Kit (ARG04040) in the Storage Compartment in back of unit. 7. Remove the packing material from under the scale by slightly lifting scale plate and sliding cardboard blocks toward the sides of the unit until blocks are clear. Use a wrench to remove the four nuts that secure the scale for shipping. 8. Remove the User s Manual from the Literature Kit, and place the remainder of the Literature Kit (0119-0337-01 or 0119-0349-01 or 0119-0361-01 or 0119-0363-01) in the Storage Compartment on top of unit.

Page 3 of 5 UNPACKING UNIT AND ACCESSORIES: (cont) BE SURE TO REVIEW THE USER S MANUAL WITH THE CUSTOMER DURING TRAINING. Then before installing the User s Manual Envelope, ask where the customer would like the envelope installed. For the MRC-450 only, there is also a Video Tape (0693-2013-01) supplied and can be viewed at the customer s convenience. 9. Peel the backing from the User s Manual Envelope (4211-0001-01) and apply the envelope, with the open end on top, to either side of the unit or in the location designated by the customer. 10. Place the User s Manual in the Envelope. PARTS AND ACCESSORIES SETUP: 1. Remove black cap from LOW port on rear of tester. 2. Attach the Temperature Probe Assembly (6004-0777-01) to the four pin connector located below the pump compartment. Place the probe tip next to the recovery tank temperature sensor, located on the right Velcro strap that holds the tank in place. 3. Remove the Recovery Tank Assembly (7009-2331-03) from box. Remove cardboard wrap from around tank. (MRC-450-6) Obtain Recovery tank from customer. 4. Open both hand valves on recovery tank to relieve the compressed air charge. POWER UP, CALIBRATION / PARAMETER SETUP: THIS UNIT MUST BE PLUGGED IN TO A PROPER AC OUTLET FOR UNIT TO OPERATE CORRECTLY. REFER TO UNIT ID PLATE LOCATED ON BACK OF UNIT. EXTENSION CORDS ARE NOT RECOMMENDED, BUT IF AN EXTENSION CORD MUST BE USED, USE A CORD THAT IS LESS THAN 50 FEET WITH A 16 AWG, OR ABOVE 50 FEET AND LESS THAN 100 WITH A 14 AWG. 1. Plug the unit into proper A.C. outlet and turn on the Main Power Switch on the rear of the unit. Make sure none of the hoses are lying on the scale. 2. Press the <POWER ON/OFF> on the front panel. The unit will go through the power up sequence and then display zero. Wait for 2 beeps indicating scale is stable. NOTE: IF DISPLAY IS OTHER THEN ZERO, REMOVE RECOVERY TANK FROM THE BOX AND PLACE RECOVERY TANK ON SCALE. ATTACH FLOAT CABLE. WAIT FOR 2 BEEPS, CALIBRATE AND THEN REMOVE TANK. 3. Press <TEMP>. If the left display shows a temperature, go to next step. If it displays "----", the temperature probe is not installed correctly, is defective, or there is a problem with the unit. Correct the problem before proceeding. 4. OIL the seals and attach the YELLOW Utility hose (3988-0278-01) to the LOW port on the back panel. Connect the other end to the Blue valve on the recovery tank, finger tight. 5. Press <AUTO SEQUENCE> on the Front panel. Observe that the "VACUUM TIME" and "AUTO SEQUENCE" LED is on.

Page 4 of 5 POWER UP, CALIBRATION / PARAMETER SETUP: (cont) 6. Press <UP> twice. The number ten should appear in the right LCD. 7. Press <HOLD/ENTER/RESTART> five (5) times. The evacuation procedure will start and run for ten minutes. The LCD should indicate at least 27 IN/HG, 700mmHG, 90 Bar, or 900 mbar. When the unit beeps twice, the procedure is finished and the "COMPLETED LED" is on. 8. Close the BLUE tank valve. Disconnect the yellow utility hose and store in glove box. 9. Remove black cap from HIGH port on rear of tester. 10. CALIBRATION: Press and hold <HOLD/ENTER/RESTART> until "CAL" is displayed. 11. Press <RECLAIM ONLY>, observe that the "IN PROGRESS" LED is flashing and the "HOLD" LED is on. 12. Press <HOLD/ENTER/RESTART>. Unit will enter a 3 minute delay for stabilization. If pressure is measured, the unit will Recover that pressure and then go into a 3 minute delay. After the 3 minute delay the right display will show the temperature of the Recovery Tank Temperature Sensor. 13. If temperature matches ambient, press <HOLD/ENTER/RESTART> again. If not press <UP> or <DOWN> keys to adjust. The unit will sound one long beep and the "COMPLETED LED" will be on. The temperature probe may be removed from the Recovery Tank Sensor. 14. Programming of the Default Settings can be accessed by pressing and holding both the <UP> and <DOWN> arrows at the same time for 5 seconds. Select desired default setting by pressing the <UP> and <DOWN> arrows individually and pressing <ENTER> to program. R134a should be displayed for refrigerant type, if not see service manual for correct Dip switch settings. PREPARING UNITS HOSES AND SCALE: 1. OIL o-rings on two Inline Particle Filters (7009-2418-01) Install one filter on each of the high and low side fittings on rear panel. 2. OIL the seals in the RED Hose Assembly (EAH0001C02A) and attach to the Inline Particle Filter (7009-2418-01) on the HIGH side fitting. 3. OIL the seals in the BLUE Hose Assembly (EAH0001C01A) and attach to the Inline Particle Filter (7009-2418-01) on the LOW fitting. 4. OIL the seal and attach the HIGH side R-134a vehicle adapter (0647-0287-09) to the red hose assembly. 5. OIL the seal and attach the LOW side vehicle adapter (0647-0287-10) to the BLUE Hose Assembly. 6. OIL the seals and install Inline Particle Filter (7009-2418-01) on Low side fitting on Recovery Tank Assembly. OIL seal on the Blue Hose in the Scale Compartment and connect to the Low side Inline Particle Filter (BLUE). 7. OIL seals on the Red Hose in the Scale Compartment and connect to the fitting with the RED Tank Valve on the Recovery Tank Assembly. 8. Set the Tank GENTLY on the Scale and secure it to the Right side of the Scale as viewed from the rear using the Velcro strap (CONFIRM TANK DEPRESSES SWITCH). Wait for 2 beeps indicating the scale is stable.

PREPARING UNITS HOSES AND SCALE: (cont) Page 5 of 5 9. Connect the Recovery Tank Cable Assembly (6004-0760-01) to the Tank and the "Tank Sensor" fitting on the underside of the pump compartment. 10. Open the Red and Blue valves on the Recovery Tank. NOTE: HEATER BLANKET IS EXTREMELY HOT USE STANDARD REFRIGERANT HANDLING SAFETY PROCEDURES WHEN PERFORMING INSTALLATION ALWAYS WEAR SAFETY GOGGLES, DON T SPILL OR TOUCH LIQUID REFRIGERANT, AVOID FLAMES, AND EXCESSIVE HEAT. USE ONLY IN WELL VENTILATED AREA. 11 For the MRC-450-6 and -GR, obtain the Virgin Tank from the Customer. Loosen hardware on the heater blanket, adjust heater blanket and tank switch to match the height of the virgin tank being installed. Retighten hardware. 12. Oil o-ring in the inline filter (7009-2418) and attach to the virgin tank fitting and connect the Blue Hose in the Scale Compartment to the inline filter. Open the Tank Valve. 13. Set the virgin tank GENTLY on the Scale and secure it with the heater blanket straps (CONFIRM TANK DEPRESSES SWITCH). Wait for 2 beeps indicating scale is stable. 14. Complete the questionnaire (0692-1834-01) and mail it to Sun Electric Corp. 15. Install Tank Band using instructions (0692-2253-01) if required. INSTALLATION COMPLETE REMEMBER TO OIL O-RINGS AND SEALS WHEN ATTACHING HOSES OR FITTINGS