Using the laryngeal mask airway to manage the difficult airway

Similar documents
Laryngeal Mask Airway (LMA) Indications and Use for the NH EMT-Intermediate and Paramedic

INSTRUCTIONS FOR USE KING LT 2

Airways and Resuscitators. CRC 330 Cardiorespiratory Care University of South Alabama

(3) isolates the airway preventing aspiration; (4) prevents gastric insufflation during positive

Endotracheal Tubes - VentiSeal (High Volume Low Pressure)

LarySeal - Laryngeal Mask Airways

LMA Airway portfolio. 3,000 published references. 300 million patient uses. Every 3 seconds an LMA airway is used somewhere in the world.

VividTrac R. Video Intubation Device. INSTRUCTIONS FOR USE. English

Fiberoptic Intubation Made Easi(er) Know Your Scope. Indications. Christine Whitten MD Department of Anesthesia Kaiser Permanente San Diego

SAFE SOLUTIONS TO THE PROBLEMS OF SPECIALITY ANAESTHETIC AND SURGICAL PROCEDURES. Speciality Anaesthesia Tubes

INSTRUCTIONS FOR USE LMA Unique (Silicone Cuff) & LMA Unique (Silicone Cuff) Cuff Pilot

EQUIPMENT. The LMA ProSeal a laryngeal mask with an oesophageal vent

Figure 1: LMA Unique (S) components. Figure 2: LMA Unique (S) Cuff Pilot components

SPEMS SKILLS PROFICIENCY CRITERIA Paramedic

throat/pharyngeal pack

Canine Endotracheal Intubation

STANDARDIZED PROCEDURE NEONATAL INTUBATION (Neonatal)

IDEAL FOR SHORT- TO MEDIUM- TERM ANAESTHESIA OR VENTILATION. Anaesthesia Tracheal Tubes

What s an i-gel? Why the change? i-gel O 2. i-gel Features 12/26/2018. NWC EMSS i gel tutorial Connie J. Mattera, MS, RN, PM

Ambu AuraGain Single Use Laryngeal Mask - Sterile

Chapter 9 Airway Respirations Metabolism Oxygen Requirements Respiratory Anatomy Respiratory Anatomy Respiratory Anatomy Diaphragm

Airway Larry Airway Management Trainer Head LF03667U Instruction Manual

Product information. The new LTS-D. The 2nd generation supraglottic airway device ideal for clinical use and pre-hospital environment

Emergency Products Difficult Airway

Pittsburgh EMS Pre-Hospital Care Monograph

PneuX P.Y. Endotracheal Tube. Designed exclusively for use with the Venner PneuX P.Y. System

PneuX P.Y. Endotracheal Tube. Designed exclusively for use with the Venner PneuX P.Y. System

(12) Patent Application Publication (10) Pub. No.: US 2008/ A1

Emergency Products Difficult Airway

USER GUIDE.

AirSim User's Guide. Version 2.1. True anatomy True training True to life

KimVent * Closed Suction System Solutions for the Home Care Pediatric Patient. Instructions for Use. Ballard* Trach Care* Technology

QED-100 Clinical Brief

Difficult Airway Management Simulator

Emergency Products Difficult Airway

Great products available through ROI!

INSTRUCTION MANUAL S SIMON AIRWAY TRAINER. Gaumard Scientific Company, Inc SW 136 Street Miami, FL

Understanding Tracheostomy Care

HAL S User Guide

TUBINGS / CONNECTION PIECES

Dr C Verghese LMA Research Centre Royal Berkshire Hospital Reading, UK. Page 30

Venner PneuX ETT/TT INSTRUCTIONS FOR USE

(12) Patent Application Publication (10) Pub. No.: US 2012/ A1

KOALA. Disposable Adult Anaesthetic Circuits for Low Flow Anaesthesia KO.S5.22MM. Adult Anaesthetic Circuits. Medical Pty Ltd

Mirage Vista Nasal Mask

Using the Pressure Products SafeSheath Worley Telescopic Lateral Vein Introducers to Optimize LV Lead Placement

TrapLiner Catheter. Guide Extension Plus Wire Trapping

Ambu Aura40. Key Benefits

Mucosal pressure and oropharyngeal leak pressure with the ProSeal versus laryngeal mask airway in anaesthetized paralysed patients

PRODUCT CATALOGUE OF

1. Connect the attached anesthesia mask to your anesthesia system using the included tubing and connectors.

Solutions for Oxygen Therapy & Airway Management

UNIT 9 - RESPIRATORY SYSTEM LECTURE NOTES

Product Catalogue. Emergency Medicine

SimNewB. User Guide.

Endotracheal Tube Exchanger. Technology for License

Booster Pump PB4-60 Replacement Kits

C-1 C-7. C-6 Short air tubing Upper Velcro straps. C-a C-5 C-2 C-4 C-3 B-1 B-9 B-10 B-2 B-7 B-8 B-3 B-6 D-1 D-2 D-13 D-3 D-12 D-10 D-11 D-4 D-5 D-8

SARASOTA MEMORIAL HOSPITAL NURSING PROCEDURE

Procedure 85 Attaching The Humidifier To The Oxygen Flow Meter Or Regulator. Procedure 86 Administering Oxygen Through A Nasal Cannula

VAPOMATIC ANESTHETIC VAPORIZER

A simple method of partial inflation of the LMA cuff before insertion in children to allow cuff pressure without adjustment after insertion

SimBaby. User Guide.

HOSPITAL: Date: Date: Date: Date:

Breathing Process: Inhalation

Anesthesia Intensive Care

VariSource High Dose Rate Afterloader Procedures. For Performing Breast Brachytherapy with. The SAVI TM Applicator

CARBON DIOXIDE ELIMINATION FROM SEMICLOSED SYSTEMS

Endotracheal Suctioning: In Line ETT

TruMan Trauma. User Manual Version 1:4

Chester Chest Model 2400 User s Manual

Chester Chest Model 2400 User s Manual

Model 405 &407 Small Animal Ventilator. User Manual v3.5

Assessment & Placement GUIDE

Military VBM. Medizintechnik GmbH VBM 1

AT Kelly Torso. Directions for Use

Bielefeld. Balloon Catheter The new treatment for chronic tube malfunction. Innovations by Spiggle & Theis

AIRWAY Management. How to manage an airway on the battlefield TRAININGGROUNDS

RESUSCITATION. If baby very floppy and heart rate slow, assist breathing immediately. If baby not breathing adequately by 90 sec, assist breathing

AIRWAY MANAGEMENT TRAINER LF03601U INSTRUCTION MANUAL

Trampoline & Enclosure Assembly Instructions

Health Professional Info

INSTRUCTIONS. Sterilization lot number

Butler Tactical Parachute Systems, LLC

Pediatric. VBM Medizintechnik GmbH. Products VBM 1

AT Kelly Torso. Directions for Use

Understanding Tracheostomy Care for your Child

Making Life Easier Easypump II

Virginia Office of Emergency Medical Services Scope of Practice - Procedures for EMS Personnel

Colonoscopy: A Few Simple Rules

Then the partial pressure of oxygen is. b) Gases will diffuse down a pressure gradient across a respiratory surface if it is: i) permeable ii) moist

MyoSure Setup Simplified

Trampoline & Enclosure Assembly Instructions

CONTINUING EDUCATION IN HONOR OF NORMAN TRIEGER, DMD, MD

ADVANCED Airway Larry AIRWAY MANAGEMENT TRAINER LF03685U INSTRUCTION MANUAL

INSTRUCTION MANUAL. January 23, 2003, Revision 0

AUTOVENT 4000 VENTILATOR

CRICOID PRESSURE TRAINER LF03760U INSTRUCTION MANUAL

A Quick Start Guide for the ER 4123D CW-Resonator

Lesson 28. Function - Respiratory Pumps in Air Breathers Buccal Force Pump Aspiration Pump - Patterns of Gas Transfer in Chordates

Transcription:

Anesthesiology Clin N Am 20 (2002) 863 870 Using the laryngeal mask airway to manage the difficult airway Martin S. Bogetz, MD Department of Anesthesia and Perioperative Care, University of California San Francisco, 400 Parnassus Avenue, A3, San Francisco, CA 94143-0368, USA Before 1990, the choice of an airway device essentially was limited to the facemask or the endotracheal tube (ETT). Since then, a number of novel supraglottic airway devices have been developed. The laryngeal mask airway (LMA; The Laryngeal Mask Company Limited, LMA North America, San Diego, CA) was introduced to the United States in 1991 after 3 years of use in the United Kingdom and other countries. Today the LMA has a clearly established role as an airway device in the elective setting when neither the procedure nor the patient require tracheal intubation. Perhaps more importantly, the LMA also has proved extremely useful in managing the difficult airway. Dr. Archie Brain, inventor of the LMA, continues to create additions to and variations of the original LMA. At present, these variations include eight sizes of the original (LMA-Classic), a single-use LMA (LMA-Unique), a reinforced/ flexible LMA (LMA-Flexible), an LMA specifically designed for tracheal intubation (LMA-Fastrach), and an LMA with an integral gastric access/venting port (LMA-ProSeal). As of April 2002, there are more than 2140 Medline citations involving the LMA. This article reviews the use of the various LMA devices to manage the difficult upper airway. Laryngeal mask airway-classic The LMA has an important role in the management of the difficult airway. Included in the American Society of Anesthesiologists Practice Guideline for the Difficult Airway, it can be used as the primary airway or as a channel for a fiberscope. Successful use of the LMA does not require the same constellation of factors required for direct laryngoscopy and tracheal intubation. Consequently, it can provide an airway in both the cannot intubate can ventilate and the E-mail address: bogetzm@anesthesia.ucsf.edu 0889-8537/02/$ see front matter D 2002, Elsevier Science (USA). All rights reserved. PII: S0889-8537(02)00047-0

864 M.S. Bogetz / Anesthesiology Clin N Am 20 (2002) 863 870 cannot intubate cannot ventilate situations if the problem is supraglottic in nature. The relative ease of learning how to insert and use the LMA has facilitated its use by health care workers other than anesthesiologists and nurse anesthetists. Such individuals include paramedics, neonatologists, emergency room physicians, and critical care nurses. The trachea can be intubated a number of ways using the original LMA. All such techniques rely on the fact that the aperture of a properly positioned LMA aligns itself anatomically with the glottis (Fig. 1). Passing an ETT blindly through the LMA into the trachea has an unacceptably low degree of success. Difficulties include catching the ETT tip on the aperture bars or the anterior commissure. The latter problem is a result of the natural bend in a standard polyvinyl chloride (PVC) ETT and the angle at which the ETT exits the LMA. A maximum 7.0-mm internal diameter cuffed ETT can be passed through the size 5 and 6 LMAs; a maximum 6.0 can be passed through sizes 3 and 4. An important limitation in using a standard ETT is that it may not project far enough beyond the LMA through the larynx and into the trachea to provide a secure airway. One solution is Fig. 1. Schematic of a properly positioned LMA.

M.S. Bogetz / Anesthesiology Clin N Am 20 (2002) 863 870 865 to use a 6.0 microlaryngeal tube (Mallinckrodt Critical Care, Glens Falls, NY), which is 5 cm longer than a standard 6.0 and 2.5 cm longer than a standard 7.0 ETT (Fig. 2). An elegant and safe technique uses the LMA as a channel for a fiberscope. Those who are familiar with fiberscopic techniques appreciate the critical importance of the channel the fiberscope traverses. When properly positioned, the LMA orifice is directly opposite the laryngeal inlet. In preparation, a welllubricated ETT is placed in the tube portion of the LMA and the cuff is inflated (Fig. 3). A swivel adapter (Portex No. 625191, Sims Portex, Keene, NH) allows delivery of oxygen and volatile anesthetic while a flexible fiberscope (eg, 5-mm outer diameter) is passed through the LMA and into the trachea. The cuff is deflated, the ETT is advanced into the trachea, and its proper position is confirmed. At this point, an important limitation becomes apparent. There is no simple way to remove the LMA without disturbing the ETT. The LMA should be deflated and left in place until the trachea is extubated. If the LMA must be removed or the ETT changed because of inadequate diameter or length, an exchange catheter can be passed through the ETT (within the LMA) into the trachea, the LMA can be removed, and another ETT can be passed over the stylet. A catheter with a lumen (Cook airway exchange catheter, No. C-CAE-14.0-83, Bloomington, IN) is safest because one can ventilate the lungs with a jet ventilator with just the exchanger in place. Caution always is warranted when using these catheters and jet ventilation. Fig. 2. Comparison of a standard 4.0 ETT and a 4.0 microlaryngeal tube ETT when passed through a size 4 LMA. Note the important difference in the length of ETT that projects beyond the LMA.

866 M.S. Bogetz / Anesthesiology Clin N Am 20 (2002) 863 870 Fig. 3. Insertion of the ETT into the LMA in preparation for fiberoptic intubation through the LMA. Note the swivel adapter on the ETT. Recently, a new airway catheter became available to make this procedure easier. The Aintree Intubation Catheter (Cook, No. C-CAE-19.0-56-AIC) is an exchange catheter with a lumen large enough for a fiberscope. Once an LMA is positioned properly, the Aintree catheter can be passed into the LMA, and a fiberscope can be passed through it (Fig. 4). Under fiberoptic guidance, the catheter is passed through the LMA into the trachea. Then the fiberscope and LMA can be removed, leaving just the catheter in place. An ETT with an inner diameter of 7 mm or larger can be passed over the catheter into the trachea. This step may be difficult because of the short length of the catheter. If necessary, the catheter can be used to jet-ventilate the lungs. With this technique, special ETTs are not needed, and a large ETT can be placed initially. Laryngeal mask airway-fastrach The LMA-Fastrach or intubating LMA (ILMA) is designed to specifically overcome the problems associated with (blind) tracheal intubation through the original LMA. It consists of a rigid, anatomically curved airway tube made of stainless steel with a standard 15-mm connector. The tube is wide enough to accommodate an 8.0 ETT and short enough to ensure passage of the ETT beyond the vocal cords. A rigid handle attached to the tube facilitates one-handed insertion, removal, and most importantly, adjustment of the device s position so that the aperture directly opposes the larynx. The ILMA is available in three sizes (3, 4, 5) that correspond to the cuff size of the original LMA. The remainder of the device is identical for all three sizes, and

M.S. Bogetz / Anesthesiology Clin N Am 20 (2002) 863 870 867 Fig. 4. The Aintree catheter, fiberscope, and LMA. all accommodate an 8.0 ETT. Many find insertion of the ILMA easier than the original LMA because the rigid tube follows the anatomic curve of the palate and posterior pharyngeal wall and one s index finger does not have to enter the mouth. Once positioned correctly, the ILMA can be connected to a circuit and used as an airway device; however, the safety of keeping such a rigid object in the mouth for a long period must be considered. To achieve the highest degree of success in intubating the trachea blindly through the ILMA, it is recommended strongly that the special, supplied ETT be used (Euromedical ILM Endotracheal Tube, Euromedical, Malaysia). This silicone tube is soft tipped, straight, wire reinforced, and cuffed. When compared with a standard PVC ETT, it exits the ILMA at an angle that facilitates passage through the glottis (Figs. 5 and 6). Three ETT sizes (internal diameter) are available (7.0, 7.5, 8.0), and each fits through each of the three ILMA sizes. Each ILMA comes with one of these special tubes. Because the special ETT is reusable, its cuff is a low-volume, high-pressure design in contrast to the high-volume, lowpressure cuff in a PVC tube. Careful attention must be paid to cuff inflation pressures, particularly when nitrous oxide is used. A relatively larger-size ETT should be used because the low-volume, high-pressure cuff does not have the bulk to span the trachea s diameter. For men, ILMA sizes 4 and 5 are best for ventilation and blind intubation. For women, sizes 3 and 4 are best for ventilation, but all three can be used for intubation. Once the correct-sized ILMA is positioned properly and the patient is well oxygenated, the special ETT is lubricated and inserted into the ILMA tube. Rotating and moving the ETT in and out helps distribute the lubricant. The single horizontal indicates the depth at which the ETT enters the

868 M.S. Bogetz / Anesthesiology Clin N Am 20 (2002) 863 870 Fig. 5. The LMA-Fastrach. mask aperture. The ILMA handle is grasped and elevated (not levered) just like a laryngoscope. This maneuver straightens the angle between the ILMA and the glottis. The ETT tube is passed gently beyond this horizontal line. With experience, one can feel when the specialized ETT is passing into the trachea. If resistance is felt immediately, the selected ILMA is too large. If resistance is felt 2 cm beyond the transverse line, the epiglottis may be downfolded. Resistance felt at 3 cm may indicate that the selected ILMA is too small. If resistance is felt at 4 to 5 cm, the selected ILMA may be too large. The Instruction Manual and LMA Web site (http://www.lmana.com) [1] provide more detailed guidance. A novel approach is to use a light wand inside the special ETT. The glottic area will light up when the ETT is passed successfully into the trachea. A fiberscope also can be used, but it must be passed through an ETT that projects beyond the aperture. In contrast to the easily displaced aperture bars of the original LMA, the ILMA has a single flap, the epiglottic elevating bar. A fiberscope can be damaged if pushed through the epiglottic elevating bar unprotected. To remove the ILMA once the trachea is intubated, one should remove the 15-mm ETT connector while the ETT cuff remains inflated. This connector should be kept connected to the circuit to avoid its loss. One then can ease the ILMA out by gently swinging the handle to follow the curvature of the rigid shaft. One should swing the ILMA out of the pharynx and mouth while applying

M.S. Bogetz / Anesthesiology Clin N Am 20 (2002) 863 870 869 Fig. 6. Note the gross difference in the angle at which the special Euromed tube and a standard PVC ETT exit the ILMA. counter-pressure to the ETT. To hold the ETT tube in place, the included stabilizing rod (20 cm) is opposed to its proximal end, which effectively increases the length of the ETT and permits sliding of the ILMA out of the mouth. The ETT tube should be grasped in the pharynx as soon as the ILMA clears. The pilot balloon and inflation line will thread through the ILMA because of its attachment to the proximal end of the ETT. One now can reconnect the 15-mm fitting. If the decision is made to replace this ETT, a tube exchanger can be used in the manner described earlier. Laryngeal mask airway-proseal This unique device represents a substantial change in LMA design. Two issues of concern have bedeviled the LMA. Although rarely an actual problem, some practitioners refuse to use the LMA because of their concern for gastric distention with positive pressure ventilation. To address this issue, the ProSeal has an integral gastric access/venting port and tube. When properly positioned, the distal orifice of this tube lies in the upper esophagus. Sealed off from the glottis, the esophagus and stomach can be vented to air or a 14-F sump tube can be passed and gastric contents evacuated. Mask design is also unique. The bowl is open, and the inflatable portion extends around the back. When inflated, the mask is pushed anteriorly and the glottis becomes enveloped in the bowl, in contrast to

870 M.S. Bogetz / Anesthesiology Clin N Am 20 (2002) 863 870 the original design, in which the LMA and glottis opposed each other and the aperture bars prevented the glottis from herniating into the bowl. A better airway seal usually results at a given cuff pressure versus the original LMA. In the elective situation, the ProSeal may expand LMA use to those patients with treated or asymptomatic reflux or hiatal hernia. In addition, the ability to use positive pressure ventilation will be facilitated. In the emergency situation, the ProSeal may prove particularly useful when positive pressure ventilation is necessary and gastric distention or regurgitation is a major concern (eg, failure to intubate in obstetrics). Note that the ProSeal is not useful as a channel for a fiberscope. The ProSeal is discussed in detail by Drs. Brimacombe and Keller elsewhere in this issue. Reference [1] LMA North America. Available at:http://www.lmana.com. Accessed October 17, 2002.