MPC1M, MPC2M and MPC2AM Monnier High Efficiency Compressed Air Filter / Regulators

Similar documents
MF2M Monnier Miniature Compressed Air Filter

IX1 Spirax-Monnier International Compressed Air Filter Installation and Maintenance Instructions

ML3M Monnier Miniature Compressed Air Lubricator

Dri-Line Mk3 Monnier Compressed Air Drain Trap

Dri-Line Mk2 Spirax-Monnier Compressed Air Drain Trap

IP2M, IP2AM and IP2DM Monnier International Compressed Air Filter/ Regulators

DF1 and DF2 Diffusers

TA10A and TA10P Steam Tracing Temperature Control Valves Installation and Maintenance Instructions

TSS21 Sealed Thermostatic Steam Tracer Trap

SA121, SA122, SA123, SA128 and SA1219 Self-acting Temperature Control Systems (Dial Adjustment)

SA121, SA122, SA123, SA128 and SA1219 Self-acting Temperature Control Systems (Knob Adjustment)

PV4 and PV6 Piston Valves

MST21 Stainless Steel Balanced Pressure Thermostatic Steam Trap

BT6HC Hygienic Sanitary Balanced Pressure Steam Trap for High Capacity and CIP/SIP Applications

Fig 12, Fig 14HP, Fig 16, Fig 16HP and Fig 16L Strainers

Fig 1, Fig 12, Fig 13, Fig 14HP, Fig 16, Fig 16HP and Fig 16L Strainers

DCV1, DCV3 and DCV3LT Disc Check Valves Installation and Maintenance Instructions

Spiratec ST14, ST16 and ST17 Sensor Chambers and sensors

KBV21i and KBV40i Key Operated Boiler Blowdown Valves Installation and Maintenance Instructions

TP1 and TP2 Temporary Cone Shaped Strainers

DCV10 Stainless Steel Disc Check Valve for use with Condensate Pumps

FV Flash Vessel Installation and Maintenance Instructions

S1, S2, S3, S5, S6, S7, S8, S12 and S13 Separators

S1, S2, S3, S5, S6, S7, S8, S12 and S13 Separators Installation and Maintenance Instructions

CVS10 Sanitary Check Valves

KBV21i and KBV40i Air Actuated Boiler Blowdown Valves

CP10 Sensor Installation and Maintenance Instructions

Manual Actuated Boiler Blowdown Valves

IFTGS14 Ball Float Steam Trap ½" and ¾" with Integral Spiratec Sensor

MSC-P and MSC-N Manifolds for Steam Distribution and Condensate Collection

DCV6 Disc Check Valve

AVC32 Carbon Steel Air Vent for Steam Systems

UIB30 and UIB30H Sealed Inverted Bucket Steam Traps for use with Pipeline Connectors

FTGS14 Ball Float Steam Trap DN15 (½") to DN25 (1")

AE14 Automatic Air Vents for Liquid Systems Installation and Maintenance Instructions

APT14, APT14HC and APT14SHC Spares 2

AVM7 Stainless Steel Thermostatic Air Vent

SRV66 Sanitary Pressure Reducing Valve

BCV31 DN40 - Blowdown Control Valve

Spirax Compact FREME Flash Recovery Energy Management Equipment

HM and HM34 Inverted Bucket Steam Traps Installation and Maintenance Instructions

AE30 Automatic Air Eliminators / Air and Gas Vents for Liquid Systems

Fig 3, 7, 33, 34, 34HP, 36, 36HP, 37, 3616 and Fig 3716 Flanged Strainers

TW Temperature Control Valve

SA Control Valve types: BM, BMF, BX, SB, NS, KA, KB, KC (Normally open) BMRA, BMFRA, BXRA, SBRA, NSRA, KX, KY (Normally closed)

Airodyn, BRair and BRoil Compressed Air Drain Traps

M33F ISO, M33S ISO and M33V ISO Ball Valves Installation and Maintenance Instructions

BTM7, BTS7 and BTS7.1 Stainless Steel Thermostatic Clean Steam Traps

IP2, IP2A and IP2D. Spirax-Monnier International Compressed Air Filter/ Regulators

IP2M, IP2AM and IP2DM Monnier International Compressed Air Filter/ Regulators

BCV31 DN20 - Blowdown Control Valve

SRV2S Pressure Reducing Valve

CA44, CA44S, CA46 and CA46S Air and Gas Traps

S and SF Inverted Bucket Steam Traps

MFP14-PPU (Vented) Automatic Packaged Pump Units

CS10-1 Stainless Steel Clean Steam Separator

Type 130 and HL10 'Safeguard High Limit Control' Installation and Maintenance Instructions

BRV71 and BRV73 Pressure Reducing Valves

M10HTi ISO Tobacco Ball Valve Screwed, SW, BW and Flanged versions

TDC46M, TDS46M and UTDS46M Thermodynamic Steam Traps with Maintainable Seat Installation and Maintenance Instructions

BPT13 Balanced Pressure Thermostatic Steam Traps

PC10HP Pipeline Connector (ASME 600)

M70i ISO and M80i ISO Stainless Steel Ball Valves for Sanitary Systems Installation and Maintenance Instructions

BT6-B Sanitary Balanced Pressure Thermostatic Steam Trap

Fig 7, 33, 33.1, 34, 34HP, 36, 36HP, 37, 3616 and Fig 3716 Flanged Strainers Installation and Maintenance Instructions

TD62LM and TD62M Thermodynamic Steam Traps with Replaceable Seats

Vane Flow Switches Colima FLU Series

CA10S, CA14 and CA14S Air and Gas Traps

TD62LM and TD62M Thermodynamic Steam Traps with Replaceable Seats Installation and Maintenance Instructions

QuickHeat TM Packaged Heat Exchanger Solutions

Spirax SafeBloc TM DBB3 Double Block and Bleed Bellows Sealed Stop Valve. 1. Safety information. 2. General product information. 3.

FT53, IFT53, FT54, IFT54, FT57 and IFT57 Ball Float Steam Traps - DIN

SCA Series Inverted Bucket Steam Traps

BDV1 and BDV2 Blowdown / Depressurisation Valves

Thermocirc Installation and Maintenance Instructions

M111 Spiraflo Transducer

STERI-TROL Clean Service 'S' Series Two-port Control Valves DN15 (½") to DN100 (4")

M45 ISO Ball Valve DN25 to 150 Installation and Maintenance Instructions

AE50S Automatic Air and Gas Vent for Liquid Systems Installation and Maintenance Instructions

BDV60 Blowdown Vessel Installation and Maintenance Instructions

A3S Bellows Sealed Stop Valve Installation and Maintenance Instructions

AVS32 Stainless Steel Air Vent for Steam Systems Installation and Maintenance Instructions

CA16 and CA16S-14 Air and Gas trap Installation and Maintenance Instructions

SRV461S and SRV463S Stainless Steel Direct Acting Pressure Reducing Valves

FT16 Ball Float Steam Trap Installation and Maintenance Instructions

BSA6T and BSA64T Stainless Steel Bellows Sealed Stop Valves Installation and Maintenance Instructions

TD45 Thermodynamic Steam Trap Installation and Maintenance Instructions

USM21 Sealed Bimetallic Steam Trap for use with Pipeline Connectors Installation and Maintenance Instructions

FT43, FT44, FT46 and FT47 Ball Float Steam Traps Installation and Maintenance Instructions

BTD52L Thermodynamic Steam Trap Installation and Maintenance Instructions

Colima TOR Magnetic Level Switches

BCVi43 Blowdown Control Valve

Fig 1, Fig 12, Fig 13, Fig 14, Fig 16 and Fig 16L Strainers Installation and Maintenance Instructions

FTC62 and FTS62 Ball Float Steam Traps Installation and Maintenance Instructions

595-K/L and 596-K/L Series Self Operated Valves Installation and Maintenance Instructions

LP31 Level Probe. 1. Safety information. 2. General product information. 3. Installation. 4. Wiring. 5. Maintenance

PC3000, PC3001 and PC4000, PC4001 Pipeline Connectors

1. General safety information. 2. General product information. 3. Installation. 4. Commissioning. 5. Operation. 6. Maintenance. 7.

TD10, TD52M and TD259 Thermodynamic Steam Traps Installation and Maintenance Instructions

Mounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator

Transcription:

5043150 /2 IM-P504-08 CH Issue 2 MPC1M, MPC2M and MPC2AM Monnier High Efficiency Compressed Air Filter / Regulators Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation and Commissioning 4. Operation 5. Spare parts and Maintenance MPC2M shown with optional pressure gauge Copyright 2012 IM-P504-08 CH Issue 2 1 Printed in the USA

2 IM-P504-08 CH Issue 2

1. Safety information The MPC1M compressed air filter / regulator is ATEX compatible - Directive 94 / 9 / EC (ATEX95) Declaration The MPC1M is intended for use in potentially explosive environments as defined by Equipment Group II Category 2. We have determined the MPC1M is a 'simple' mechanical product. It is therefore not covered by the scope of the ATEX directive and consequently does not need to carry any marking As part of our conformity assesment, an ignition hazard analysis to EN 13463-1 was conducted with the following outcome: We have determined the MPC1M does not have its own effective sources of ignition - even in the event of rare failures. Note: As defined by the European ATEX Standing Committee... "Electrostatic charges caused by the flow-through of a medium are not considered as "own" ignition source in the sense of directive 94 / 9 / EC." The MPC1M may be used in a potentially explosive environment, as defined by Equipment Group II Category 2, when used in accordance with its Installation and Maintenance Instructions (IM-P504-08). Safe operation of these products can only be guaranteed if they are properly installed, commissioned, used and maintained by qualified personnel (see Section 1.11) in compliance with the operating instructions. General installation and safety instructions for pipeline and plant construction, as well as the proper use of tools and safety equipment must also be complied with. 1.1 Intended use Referring to the Installation and Maintenance Instructions, name-plate and Technical Information Sheet, check that the product is suitable for the intended use/application. The products comply with the requirements of the European Pressure Equipment Directive 97/23/EC and fall within the category 'SEP'. It should be noted that products within this category are required by the Directive not to carry the mark. i) The products have been specifically designed for use on compressed air, which is in Group 2 of the above mentioned Pressure Equipment Directive. The products use on other fluids may be possible but, if this is contemplated, Spirax Sarco should be contacted to confirm the suitability of the product for the application being considered. ii) Check material suitability, pressure and temperature and their maximum and minimum values. If the maximum operating limits of the product are lower than those of the system in which it is being fitted, or if malfunction of the product could result in a dangerous overpressure or overtemperature occurrence, ensure a safety device is included in the system to prevent such over-limit situations. iii) Determine the correct installation situation and direction of fluid flow. iv) Spirax Sarco products are not intended to withstand external stresses that may be induced by any system to which they are fitted. It is the responsibility of the installer to consider these stresses and take adequate precautions to minimise them. v) Remove protection covers from all connections and protective film from all nameplates, where appropriate, before installation on steam or other high temperature applications. IM-P504-08 CH Issue 2 3

1.2 Access Ensure safe access and if necessary a safe working platform (suitably guarded) before attempting to work on the product. Arrange suitable lifting gear if required. 1.3 Lighting Ensure adequate lighting, particularly where detailed or intricate work is required. 1.4 Hazardous liquids or gases in the pipeline Consider what is in the pipeline or what may have been in the pipeline at some previous time. Consider: flammable materials, substances hazardous to health, extremes of temperature. 1.5 Hazardous environment around the product Consider: explosion risk areas, lack of oxygen (e.g. tanks, pits), dangerous gases, extremes of temperature, hot surfaces, fire hazard (e.g. during welding), excessive noise, moving machinery. 1.6 The system Consider the effect on the complete system of the work proposed. Will any proposed action (e.g. closing isolation valves, electrical isolation) put any other part of the system or any personnel at risk? Dangers might include isolation of vents or protective devices or the rendering ineffective of controls or alarms. Ensure isolation valves are turned on and off in a gradual way to avoid system shocks. 1.7 Pressure systems Ensure that any pressure is isolated and safely vented to atmospheric pressure. Consider double isolation (double block and bleed) and the locking or labelling of closed valves. Do not assume that the system has depressurised even when the pressure gauge indicates zero. 1.8 Temperature Allow time for temperature to normalise after isolation to avoid danger of burns. 1.9 Tools and consumables Before starting work ensure that you have suitable tools and/or consumables available. Use only genuine Spirax Sarco replacement parts. 1.10 Protective clothing Consider whether you and/or others in the vicinity require any protective clothing to protect against the hazards of, for example, chemicals, high/low temperature, radiation, noise, falling objects, and dangers to eyes and face. 4 IM-P504-08 CH Issue 2

1.11 Permits to work All work must be carried out or be supervised by a suitably competent person. Installation and operating personnel should be trained in the correct use of the product according to the Installation and Maintenance Instructions. Where a formal 'permit to work' system is in force it must be complied with. Where there is no such system, it is recommended that a responsible person should know what work is going on and, where necessary, arrange to have an assistant whose primary responsibility is safety. Post 'warning notices' if necessary. 1.12 Handling Manual handling of large and/or heavy products may present a risk of injury. Lifting, pushing, pulling, carrying or supporting a load by bodily force can cause injury particularly to the back. You are advised to assess the risks taking into account the task, the individual, the load and the working environment and use the appropriate handling method depending on the circumstances of the work being done. 1.13 Residual hazards In normal use the external surface of the product may be very hot. If used at the maximum permitted operating conditions the surface temperature of some products may reach temperatures of 90 C (194 F). Many products are not self-draining. Take due care when dismantling or removing the product from an installation (refer to 'Maintenance instructions'). 1.14 Freezing Provision must be made to protect products which are not self-draining against frost damage in environments where they may be exposed to temperatures below freezing point. 1.15 Disposal Unless otherwise stated in the Installation and Maintenance Instructions, this product is recyclable and no ecological hazard is anticipated with its disposal providing due care is taken. 1.16 Returning products Customers and stockists are reminded that under EC Health, Safety and Environment Law, when returning products to Spirax Sarco they must provide information on any hazards and the precautions to be taken due to contamination residues or mechanical damage which may present a health, safety or environmental risk. This information must be provided in writing including Health and Safety data sheets relating to any substances identified as hazardous or potentially hazardous. IM-P504-08 CH Issue 2 5

2. General product information 2.1 General description The MPC_M Monnier range of (self-relieving) high efficiency oil removing filter / regulators provide very high quality compressed air, with accurate pressure control, for pneumatic actuators and general purpose systems. Principal features: - Compact miniature oil removing filter / regulator. - Self-relieving. - High efficiency - Exceeding 99.95% against D.O.P. tests. - Efficiency testing carried out in accordance with ISO 12500 at 51 mg / m 3 (40 ppm) inlet concentration. - Oil carryover less than 0.0255 mg / m 3 (0.02 ppm). - 100% water removal at line temperature. - Polycarbonate bowl. - External black anodised finish. - Particle effiency: 99.96% - Inlet dry pressure drop: 1.5 psi d. Available types supplied as standard MPC1M MPC2M MPC2AM ATEX compatible. Metal bowl with manual drain and tamper-proof cap. Polycarbonate bowl with manual drain. Metal bowl with autodrain. MPC optional extras - Selection table Airsets - The MPC2M, MP2AM filter / regulators are also available as airsets consisting of Type 8 or FK21 bracket, mounting ring and pressure gauge (see the 'MPC_M optional extras' table below). S = Supplied as standard OE = optional extra = not available Feature MPC1M MPC2M MPC2AM Polycarbonate bowl Bowl guard Without drain With manual drain Metal bowl With manual drain S OE (no sight glass) With autodrain S Tamper-proof cap With locking seal S OE OE Pressure gauge OE S OE 50 mm Ø OE OE 40 mm Ø S OE OE Type 8 mounting bracket OE OE FK21 fixing kit S OE OE Aluminium mounting ring S OE OE Note: A tamper-proof cap with locking seal is recommended as an optional extra for MPC2M and MPC2AM airsets. 6 IM-P504-08 CH Issue 2

2.2 Sizes and pipe connections ¼" screwed BSP (BS 21-Rp, ISO 7) 2.3 Spring range - Operating pressure ranges All regulators can be adjusted to zero pressure, or above the figures shown. The operating range is marked on the unit: Standard spring: 0.7-9.0 bar g (10-130 psi g) Optional springs: 2.4 Operating limits 0.2-2.0 bar g (2.9-29 psi g) 0.3-4.0 bar g (4.3-58 psi g) Maximum Polycarbonate bowl 10 bar g @ 50 C (145 psi g @ 122 F) pressure/temperature Metal bowl 17 bar g @ 80 C (246.5 psi g @ 176 F) 2.5 Materials Part Body Plastic bowl Bonnet assembly Filter element Valve Material Aluminium - anodised finish Polycarbonate or aluminium alloy Aluminium Microfibre/stainless steel Nitrile Fig. 1 MPC2M Monnier high efficiency compressed air filter/regulator IM-P504-08 CH Issue 2 7

3. Installation and commissioning Note: Before actioning any installation observe the 'Safety information' in Section 1. Referring to the Installation and Maintenance Instructions, name-plate and Technical Information Sheet, check that the product is suitable for the intended installation. 3.1 Specific product safety information Polycarbonate bowls may be attacked by phosphate ester based fluids, solvents, chemical cleaners, carbon tetrachloride, etc. These and any other substances should not be allowed to come into contact with this component. Certain compressor lubricating oils also contain additives harmful to polycarbonate. Where there is any doubt we recommend, in the interests of personal safety, that bowl guards or metal bowls be fitted. 3.2 General information MPC_M Dimensions / weight (approximate) in mm and kg Unit Size A B C E E1 Weight MPC1 ¼" 75 167 38 25-0.2 MPC2 ¼" 67 156 38 25 45 0.2 MPC2A ¼" 75 167 38 25-0.2 C Tamper-proof cap Dimensions (approximate) in millimetres Ø37 51 Bowl guard A B Pressure gauge (Not for MPC2AM) Available in two sizes (1½" and 2"), with 3 pressure ranges. The face is marked in both bar and psi. Please state, size and pressure range when placing an order. Pressure ranges 0 to 7 bar 0 to 2 bar 0 to 30 psi 0 to 100 psi 0 to 11 bar 0 to 160 psi Dimensions (approximate) in millimetres Size A B C 1½" 40 47 R " 2" 48 45 R " Withdrawal distance: E Without bowl guard E1 With bowl guard C 6 4 50 8 Bowl guard In the interest of safety Spirax Sarco recommend that a bowl guard should be fitted - see Section 3.1, Specific product safety information. Fig. 2 B 10 bar 0 0 2 A 8 IM-P504-08 CH Issue 2

Type 8 mounting bracket (Fig. 3) and mounting ring for general installations The filter/regulator can be mounted using this zinc plated mild steel bracket and aluminium mounting ring. Both items are optional extras and must be specified when placing an order. Dimensions (approximate) in millimetres 31 38 10 29 12.7 64 51 Fig. 3 Type 8 mounting bracket 12.7 5 FK21 fixing kit (Fig. 4) The FK21 fixing kit is required to mount the MPC_M onto the Spirax Sarco range of PN pneumatic actuators. The fixing kit and aluminium mounting ring are optional extras and must also be specified when placing an order. 30.5 Ø8.2 32 61.5 40 Fig. 4 FK21 fixing kit 3.3 Installation 3.3.1 The unit should be fitted in horizontal pipework with the bowl vertically downwards. 3.3.2 Adequate space should be provided around the unit to allow easy access for routine servicing requirements (see Figure 2 for withdrawal distances). 3.3.3 Connect the unit so that the airflow is in the direction indicated by the arrow on the body. 3.3.4 The unit should be installed as close as possible to the equipment it is serving. 3.3.5 The body has two R " ports, one of which is available for fitting a pressure gauge to register the secondary pressure. In the event that a pressure gauge is not fitted, this port should be blanked off with the blank plug provided. Ensure that the range of the pressure gauge corresponds with that of the main control spring as indicated on the unit. The second port should not be used for any purpose and is sealed with a factory fitted plug which should not be removed. 3.3.6 Do not overload the filter cartridge (see Section 4 - Operation) or there will be a reduction in its efficiency and / or life. On heavily contaminated systems, it is advisable to fit a conventional pneumatic filter (Monnier International or Miniature) immediately in front of the unit for maximum efficiency and life cycle. 3.3.7 The polycarbonate bowl may be fitted with a bowl guard, or replaced with a metal bowl. 3.4 Adjustment - Lift the locking ring. - Turn the adjustment knob clockwise to increase the pressure. - Depress the locking ring to lock. Note: An optional tamperproof cap (not shown) may be fitted over the adjustment housing. It is recommended that all adjustments be made under flowing conditions. There will be a slight increase in set pressure when the flow stops. Adjustment knob Locking ring Fig. 5 Adjustment IM-P504-08 CH Issue 2 9

4. Operation 4.1 Operating principles With system pressure on, the regulator poppet valve assembly is in the closed position when the adjusting knob is turned fully counter clockwise (no spring load). By turning the adjusting knob clockwise, the diaphragm / piston moves downward allowing flow to come in through the orifice created between the poppet assembly and seat. Increasing downstream pressure causes the poppet assembly to move upward until the load of the spring and diaphragm / piston are balanced. The outlet pressure has now been reduced. If a valve is opened downstream, the increased demand for pressure creates a reduced pressure under the control diaphragm / piston. The poppet assembly moves downward due to the load of the control spring opening the seat area and air is allowed to meet the downstream pressure demand. Thus, the area of the opening meters the downstream flow. 4.2 Performance selection (with primary pressure 10 bar) For any specified primary filtration pressure, there is a maximum recommended air flowrate. Keeping within this, will ensure that the element performance maintains the stated high efficiency levels, particularly for the removal of oil and water contaminants. 4.3 Maximum secondary flow at peak performance Secondary pressure bar g Air flow scfm 0 1 2 3 4 5 6 7 7 6 5 4 3 2 1 Maximum recommended flow 100 80 60 40 20 Secondary pressure psi g 0 0 0 1 2 3 3.5 Air flow dm 3 /s Use of the product in this region may reduce the oil removing efficiency. 10 IM-P504-08 CH Issue 2

Adjustment knob Locking ring Fig. 6 Operation IM-P504-08 CH Issue 2 11

5. Spare parts and Maintenance 5.1 Spare parts The spare parts available are detailed below. No other parts are supplied as spares. Available spares Polcarbonate bowl, Metal bowl, (specify with or without drain) 1, 2 Drain assembly Element and 'O' ring set 2, 3 Bowl guard assembly (optional extra) 4, 5 Note: In the interests of safety Spirax Sarco recommend that a bowl guard (an optional extra) should be fitted to polycarbonate bowls. How to order spares Always order spares by using the desciption given in the column headed 'Available spares' and state the size and type of unit. Example: 1 - Element and 'O' ring set for a ¼" MPC2M Monnier high efficiency compressed air filter / regulator. 5.2 Maintenance To service the filter (no tools required): - Isolate the main air supply. - Release the pressure by turning the main control knob fully anticlockwise, remove the bowl guard if fitted and depress the drain valve. - Remove the bowl (1) and unscrew the filter element assembly (2, 3 and 4). - Clean the bowl using soap and water and dry with a lint free cloth. - Reassemble in reverse order, ensuring that the element 'O' ring (4) is fitted. - The bowl should be firmly hand tightened. 2 3 Control knob 1 Drain valve 5 4 Fig. 7 Spares parts 12 IM-P504-08 CH Issue 2