EUROFLO CULVERT PIPE. Fittings / Pipes

Similar documents
EUROFLO CULVERT PIPE. Fittings / Pipes

Quality Plastic Pipe Fittings. Technical Data. Fabricated PVC Fittings IPS Class 100, 125, 160, 200 SCH 40 & SCH 80 Solvent Weld & Gasketed

StormPRO & SewerPRO. Twin-Walled Corrugated Polypropylene Pipe and Fittings System for Non-Pressure Applications LIGHT WEIGHT

StormPRO & SewerPRO. Twin-Walled Corrugated Polypropylene Pipe and Fittings System for Non-Pressure Applications LIGHT WEIGHT

FP McCann Tunnels and Shafts 1

INSTALLATION INSTRUCTIONS FOR GRT75-PF-RFS PET FOUNTAIN

104 Chamber System Ostendorf. Ostendorf. Chamber System ISO RV-Systém OSMA

DuoSafe. DuoSafe Inch Systems. Larger sizes on request

-FRU FREEZE RESISTANT WATER VALVE COOLERS SYSTEM

Inspection Chambers and Covers

Twin-Walled Corrugated Polypropylene Pipe and Fittings System for Non-Pressure Applications

Halsey Taylor Owners Manual STOP!

INSTALLATION, OPERATION AND MAINTENANCE GUIDE

FIBERGLASS MULTI-GARD MULTI-CELL RACEWAY

INTRODUCTION TO THE MACSTEEL CABLE-LOCK PIPE SYSTEM

Installation, operation & maintenance manual - original version

Halsey Taylor Owners Manual 4410 Freeze Resistant Tubular Fountain STOP!

PVC FASTTAP SADDLES for IPS Mains. Main Size OUTLET 1 FPT 3/4 CTS (7/8 OD) COMPRESSION 1 CTS (1 1/8 OD) COMPRESSION 3/4 IPS COMPRESSION

Rapidmain Installation Guide

Pressure Compensating (PC) Spray Stakes

APG001. Application Guide for Gas. T: F: E:

Flexible Metal Hose Products

PVC Push Fit System. No glue. No wait. Just push and go.

2016 GPCOG CULVERT PIPE - BID RESULTS

WHEATLEY WHEATLEY SERIES 500 SWING CHECK VALVE. Installation, Operation and Maintenance Manual

INSTALLING SUBAQUEOUS PIPE

6. Features & Benefits Installation Considerations Jointing Instructions Pipe Sizing Calculations & Tables

Ecoflex pre-insulated pipe energy efficiency made easy

CLEANING, INSPECTION, AND TESTING OF SEWERS

Hot Tapping Machine. OPERATIONS MANUAL and OPERATING INSTRUCTIONS

Inspection Chambers Project

LoneStar Fiberglass Pools. Do-It-Yourself. Installation Manual

(Revised February,2005) CULVERTS, BRIDGES, AND FORDS

Installation of Nylon Putting NP50

THE MOST ADVANCED NAME IN WATER MANAGEMENT SOLUTIONS THE LATERAL CONNECTION SOLUTION

MAKE BOLLARD IMPACT RESISTANT PROTECT FOUNDATIONS RE-USE BOLLARD

PRODUCT CATALOGUE 2010

Underground irrigation

-Proline Polypropylene Single Wall Piping

Safe-T-Stopper. Gas-Free* Service Tee Renewal and Removal for CenterPoint Energy. *In a controlled gas environment

European Handball Federation TM EHF Beach Handball Commission

Installation and User Guide

with self-sealing gas valve system

Multi-Flow Product Catalog

On-Site Leaching Chamber Specifications & Features. Design & Installation Manual Rhode Island

Pure Water Power Purification System 4-Stage RODI Operations Manual

WHEATLEY Series 500 Swing Check Valve

Bore-Gard Installation - 1,000 ft. Perry, Oklahoma

MUELLER. Mega-Lite Drilling Machine. Reliable Connections. table of contents PAGE. Equipment 2. Operating Instructions 3-4. Parts Information 5

Field Instruction. This instruction applies to Horizon Power employees and contractors involved in Horizon Power s underground projects.

HOW TO DIG A TEST PIT

CPM Concrete Drainage Systems. Concrete Pipes Installation Manual

Field Instruction. This instruction applies to Horizon Power employees and contractors involved in Horizon Power s underground projects.

Rain Barrel Workshop 440 Ball Park Road Lexington SC March 31, 2010

DREDGING & MINING MEDIUM DUTY ABRASIVES HANDLING HOSE

June For do-it-yourselfers as well as pros, Genova is the only way to go in home plumbing and vinyl building materials.

BERMAD Irrigation. IR-100 hyflow Basic Valve. Basic Valve.

Float operated valve TYPE (SWDS)

tunnels & shafts brochure

PN LINE. Technical remarks PN 11 PN 13 PN 14 PN 15 PN 17 PN 18 PN 20 PN 23 PN 25 PN 26 PN 27 PN 28 PN 29 PN 37 PN 38 PN 39 PN 40 PN 43 PN 10 8_9 10_12

Floor Drinking Systems

SPECIFICATIONS & INSTALLATION GUIDE ANOTHER QUALITY PRODUCT BY FORZA GLOBAL WATER CRIMP EDITION: 0001

GUIDANCE FOR THE CREATION OF ARTIFICIAL SETTS

Recommendations for Marking Gas Facilities Using 3M EMS Electronic Markers

INTERLOCKED METAL HOSE

PVC DWV FITTINGS PVC-0312 MARCH 2012 SUPERCEDES PVC-0112 ASTM D2665

CPVC Transition Fittings - Female Adapter. CPVC X LEAD FREE BRASS Lead Free Max working pressure F ASTM D 2846

ITEM 400 STRUCTURAL EXCAVATION AND BACKFILL

WW-720. Pressure Reducing Control Valve

Geofabrics. Products to improve the playability of your course. golf courses

For every inch of rain that falls on a catchment area of 1,000 square feet, you can expect to collect about 600 gallons of water.

PC3_ and PC4_ Pipeline Connectors

April For do-it-yourselfers as well as pros, Genova is the only way to go in home plumbing and vinyl building materials.

MUELLER. Xp, & Lineseal 350 Butterfly Valves

BSA6T and BSA64T Stainless Steel Bellows Sealed Stop Valves Installation and Maintenance Instructions

Casing Spacer Technology Leaders

AMTEC SUPPORT GRIPS STANDARD, HEAVY DUTY & CONDUIT GRIPS

Supplement Catalog For. Marine/RV & Manufactured Housing

Geopress. Instructions for Use. Year built: from 01/2004 en_int

Product Catalogue. July We mean progress. PEX plumbing Fire safety Hydronic piping Radiant heating and cooling Pre-insulated piping

Introduction to Ecoseal

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

2. Piggery facilities

SmoothFlex Nominal Bore (SN) Dash Size

FINALIZATION OF THE HAND DUG WELL. Version : April 2009 Published by : Foundation Connect International Autors : Henk Holtslag & John de Wolf

Beavers are particularly adept at manipulating their

Compressed Air Cleaning Filter Series

Common Components for: (Procenter / Elevance / Elevance Continental-Style / International (Whip) Delivery Systems)

Delta Dual V3 (DMS-164) Installation Instructions For Ground Water Applications T. E. W

SPECIFICATION SHEET. OMEGAFLEX, Ltd. TracPipe Flexible Gas Piping Specification Sheet Specification date. ProjectName

Pressure reducing valves Index

EADIPS /FGR STANDARD

3M Electrial Markets Division EMS. Electronic Marker System

LAZY RIVER 3 3 PUMP LOCATION

TEK-M ANIFOLD 7500A. Manifolds. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys ACCESSORIES

Rain Barrels. Did You Know?

Buying more than 11 gauges? Call Lesman for additional discounts.

Instruction Manual. Alfa Laval SB Pressure Exhaust Valve ESE02965-EN Original manual

Regulating valves REG-SA and REG-SB

Piece Weight. List Price. Basket Strainer-Plastic. Wash Tray Plug. TIP TOE Tub Drain. Shower Drain Grids

Transcription:

EUROFLO CULVERT PIPE Fittings / Pipes F

EUROFLO FITTINGS RUBBERS SIZE CODE COMMENT 160 OD 200 OD 250 OD 315 OD 400 OD 500 OD 630 OD 800 OD 1000 OD 1200 OD 1550 OD 1750 OD 1950 OD 520-160-RBR 520-200-RBR 520-250-RBR 520-315-RBR 520-400-RBR 520-500-RBR 520-630-RBR 520-800-RBR 520-1000-RBR 520-1200-RBR 520-1550-RBR 520-1750-RBR 520-1950-RBR Suits SN4 + SN8 SEALING ADAPTORS SIZE CODE COMMENT 160 ID 521-2430-160 200 ID 521-2430-200 HOLESAW SIZE CODE COMMENT 110 OD 521-2431-110 Holesaw Only 160 OD 521-2431-160 Holesaw Only 200 OD 521-2431-200 Holesaw Only 110 521-2432-11 Arbor for Holesaw 160/200 521-2432-16 Arbor for Holesaw Key All Item DWV unless noted DWV= Drain Waste and Vent SW= Storm Water M+F = Male, Female Ends F+F= Female, Female Ends ADJ= Adjustable 2

SEALING RINGS SIZE CODE COMMENT 110 ID 521-2439-110 160 ID 521-2439-160 200 ID 521-2439-200 REDUCERS SIZE CODE COMMENT 315 x 250 521-315-250 400 x 250 521-400-250 400 x 315 521-400-315 500 x 400 521-500-400 BENDS AND JUNCTIONS SIZE CODE COMMENT 315 x 15 571-315-15 M+F 315 x 30 571-315-30 M+F 315 x 45 521-315-45 315 x 90 521-315-90 400 x 45 521-400-45 400 x 45 521-400-45J Junction 400 x 90 521-400-90 500 x 45 521-500-45 500 x 90 521-500-90 630 x 45 521-630-45 630 x 90 521-630-90 Note: Other fittings can be made to order Key All Item DWV unless noted DWV= Drain Waste and Vent SW= Storm Water M+F = Male, Female Ends F+F= Female, Female Ends ADJ= Adjustable 3

EUROFLO PIPE 5.8 metre lengths overall including socket Rubber ring joint if needed - see fittings page for codes for the rubber rings SN16 stiffness available to order PRODUCT CODE DESCRIPTION SN RATING CRATE QTY NOMINAL BORE (MM) OUTSIDE DIAMETER (MM) 520-160-5.8M 160 Culvert Pipe Euroflo SN8 33 150 160 520-200-5.8M 200 Culvert Pipe Euroflo SN4 18 180 200 520-250-5.8M 250 Culvert Pipe Euroflo SN4 11 220 250 520-315-5.8M 315 Culvert Pipe Euroflo SN4 6 280 315 520-400-5.8M 400 Culvert Pipe Euroflo SN4 3 350 400 520-500-5.8M 500 Culvert Pipe Euroflo SN4 2 430 500 520-630-5.8M 630 Culvert Pipe Euroflo SN4 1 530 630 520-800-5.8M 800 Culvert Pipe Euroflo SN4 1 640 800 520-1000-5.8M 1000 Culvert Pipe Euroflo SN4 1 850 1000 520-1200-5.8M 1200 Culvert Pipe Euroflo SN4 1 1030 1200 520-1550-5.8M 1550 Culvert Pipe Euroflo SN2 1 1400 1550 520-1750-5.8M 1750 Culvert Pipe Euroflo SN2 1 1600 1750 520-1950-5.8M 1950 Culvert Pipe Euroflo SN2 1 1800 1950 520-2150-5.8M 2150 Culvert Pipe Euroflo SN2 1 2000 2150 Key All Item DWV unless noted DWV= Drain Waste and Vent SW= Storm Water M+F = Male, Female Ends F+F= Female, Female Ends ADJ= Adjustable 4

EUROFLO PIPE NEW SN8 Rating 5.8 metre lengths overall including socket Rubber ring joint if needed - see fittings page for codes for the rubber rings PRODUCT CODE DESCRIPTION SN RATING CRATE QTY NOMINAL BORE (MM) OUTSIDE DIAMETER (MM) 560-250-5.8M 250 Culvert Pipe Euroflo SN8 11 220 250 560-315-5.8M 315 Culvert Pipe Euroflo SN8 6 280 315 560-400-5.8M 400 Culvert Pipe Euroflo SN8 3 350 400 560-500-5.8M 500 Culvert Pipe Euroflo SN8 2 430 500 560-630-5.8M 630 Culvert Pipe Euroflo SN8 1 530 630 560-800-5.8M 800 Culvert Pipe Euroflo SN8 1 640 800 560-1000-5.8M 1000 Culvert Pipe Euroflo SN8 1 850 1000 560-1200-5.8M 1200 Culvert Pipe Euroflo SN8 1 1030 1200 FLUMING (HALF PIPE) 5.8 metre lengths overall including socket PRODUCT CODE DESCRIPTION 520-250-FLUM 520-315-FLUM 520-400-FLUM 520-500-FLUM 520-630-FLUM 520-800-FLUM 520-1000-FLUM 520-1200-FLUM 250 Fluming Half Pipe 315 Fluming Half Pipe 400 Fluming Half Pipe 500 Fluming Half Pipe 630 Fluming Half Pipe 800 Fluming Half Pipe 1000 Fluming Half Pipe 1200 Fluming Half Pipe Key All Item DWV unless noted DWV= Drain Waste and Vent SW= Storm Water M+F = Male, Female Ends F+F= Female, Female Ends ADJ= Adjustable 5

EUROFLO SLOTTED PIPE BENEFITS: Euroflo Slotted Pipe allows you to fill in open drains without losing any ground drainage. Eliminate stock loses and comply with your environmental responsibilities to protect waterways. Quick and easy to lay, especially when compared to drain coil. Available in LARGE DIAMETERS - up to 630 Light and safe to handle Ideal replacement for old large diameter clay pipes Suits all standard PVC Bends, Y s, Tees, etc. Use economical Euroflo Go-In System to tee into larger diameter pipes FEATURES: Strong and robust Subsoil drainage of surface and water table Will not rust Resist a wide range of chemicals from very acidic to very alkaline Standard Pattern 3-5 slots depending on size Total slotted angle = 240 SLOTTED PIPE 5.8 metre lengths overall including socket PRODUCT CODE DESCRIPTION SN RATING CRATE QTY NOMINAL BORE (MM) OUTSIDE DIAMETER (MM) 590-160-5.8M 160 Slotted Drainage Pipe 33 150 160 590-200-5.8M 200 Slotted Drainage Pipe 18 180 200 590-250-5.8M 250 Slotted Drainage Pipe 11 220 250 590-315-5.8M 315 Slotted Drainage Pipe 6 280 315 590-400-5.8M 400 Slotted Drainage Pipe 3 350 400 590-500-5.8M 500 Slotted Drainage Pipe 2 430 500 590-630-5.8M 630 Slotted Drainage Pipe 1 530 630 6

EUROFLO GO-IN SYSTEM COMPONENTS: 1. Hole Saw (sold separately or hired) 2. Seal Insert 3. Special fitting (for connecting branches over 125 OD) 4. Gasket (sold separately) BENEFITS: Branches can be simply installed after main pipe placement Extremely cost effective Can be installed vertically even when water is flowing Fast and user-friendly Adaptable for branches of either ribbed PE or smooth PVC USES: Breather pipe connections Field drain connections to main drain Connections into Sumps and Gallery s INSTALLATION: Drill through top centre of corrugation at right angles to pipe axis. Insert Seal fully into hole. Lube inside of seal and insert Special Fitting. OR If under 125 OD insert branch directly into Seal Insert. For Euroflo branch fit standard sealing ring (as for Euroflo pipe connection), and insert pipe spigot into Special Fitting. For smooth PVC or PE branch, fit Gasket, lubricate, then insert branch. 1 2 3 4 DN OF BRANCH PIPE IN MM ID OF MAIN PIPE IN MM 110 250 160 350 200 400 7

EUROFLO CULVERT PIPE JAN 2018 BENEFITS: > Easy to handle > Smooth bore = flow faster, less silt build-up > Maintenance-free life span > Rust free > Resists chemically aggressive soil conditions D+ D+ D+ INSTALLATION: EXCAVATION Dig a trench wider than the pipe. Ideal depth of cover is 600. TECHNICAL DATA: > Nominal stiffness SN4 and SN8 (stocked) SN16 available on request > Socket one end > HDPE (Polyethylene) > 5.8M standard length > Sizes are outside diameter of pipe ED GRANULATED ED BEDDING GRANULATED BEDDING PIPE DIAMETER (D) PIPE DIAMETER (D) PIPE DIAMETER (D) 600 600 100 100 600 PIPE LAYING Bedding to be 5-20 compacted granular material. Lay pipe in centre of trench. Selected compactible fill (not wet clay) added in layers around pipe to cover. Top up trench with compacted ordinary fill. USES: > Farm culverts > Forestry culverts > Cut in 1/2 lengthways for stock troughs, fluming > Highway culverts > Mine culverts TIPS: > Project end of pipe to prevent erosion of backfill downstream > Timber, stone or grass headwalls to prevent erosion upstream > No sharp objects in contact with pipe when laying or backfilling > Socket end of pipe to face upstream ED GRANULATED BEDDING IMPORTANT: THOROUGHLY ALONG SIDES OF IMPORTANT: PIPE BY HAND RAMMING THOROUGHLY ALONG SIDES OF PIPE BY HAND RAMMING 100 FINALLY FINALLY 500 500 ION OF BEDDING EUROFLO pipe uses its flexibility to transfer load to the surrounding bedding. Thorough compaction of the fill along the pipe sides is important to ensure long, trouble free service. Fill should be carefully compacted by hand raing along the sides of and around the pipe and built up to the finished ground surface. LIGHT DUTY INSTALLATION Selected excavation fill may be used as bedding. It should be substantially free from rock, tree roots or rubbish. Wet or saturated clay shouldn t be used as bedding or surrounding material. The minimum depth of cover should be 500. SUPPLIER: