The instrument should have a mass range from 2 to 2000 m/z or better Interface

Similar documents
Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment Varian 310

User guide for operating the Agilent 6420A QqQ mass spectrometer by direct infusion/injection

Setting a New Standard in Flash Chromatography Performance

Indian Institute of Technology Kanpur Environmental Engineering and Management Department of Civil Engineering

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs.

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

Simultaneous Determination of a Panel of 22 Steroids in Urine and Serum by SPE and LC-MS/MS

Customer Responsibilities. Important Customer Information Series Q-TOF LC/MS Systems Site Preparation Checklist

Hiden QIC Series Gas Analysers Real-time gas analysis systems

Evaluation of linear and step gradient performance and retention time precision of the Agilent 1200 Series Rapid Resolution LC

M/s. Thermo fisher Scientific

High speed UHPLC-MS/MS determination of multiple steroids in human serum using the Nexera MX system for multiplex analysis

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

Superior Result from Analytical Instruments The constant purity of the nitrogen improves system stability and ensures reproducible results

Applications of a Magnetic Sector Process Mass Spectrometer to the Analysis of Variable Vacuum Samples

INSTRUMENT INSTRUMENT YL INSTRUMENT

DOS in Food Science & Nutrition, Manasagangotri, Mysore

Gases&Technology. Measurement of Impurities in Helium Using the Dielectric Barrier Discharge Helium Ionization Detector. FEATURE.

Trace-Level Analysis of Metanephrines in Plasma by HILIC LC-MS/MS

HumiSys HF High Flow RH Generator

Ascentis Express HPLC Columns with Fused-Core Technology

Customer Responsibilities. Important Customer Information. Agilent Infinity II Preparative HPLC System Site Preparation Checklist

The instrument will process the samples one by one till all the samples have been cleaned up.

FLUORESCENCE DETERMINATION OF OXYGEN

Customer Responsibilities. Important Customer Information. Agilent 6400 Series Triple Quad LC/MS Site Preparation Checklist

Title: Standard Operating Procedure for Measurement of Ethylene (C 2 H 4 ) in Ambient Air by Reduced Gas Detection (RGD)

Agilent 7800 ICP-MS. Specifications and Typical Performance. Fast track metals analysis with Solution-Ready ICP-MS

UNITY 2 TM. Air Server Series 2 Operators Manual. Version 1.0. February 2008

Customer Responsibilities

ANALYTICAL SCALE HPLC AGILENT SYSTEMS OPERATIONAL QUALIFICATION

Your local gas generation partner. Precision series Modular gas generation solution for GC.

Application Note. Rapid performance verification of AZURA systems with refractive index detector. Summary. Introduction

Integration of amino acid, acylcarnitine and steroids analysis in single FIA/LC-MS/MS platform

Acclaim RSLC. (Rapid Separation Liquid Chromatography)

LCMSMS Solutions For Steroid Analysis

Best Practice for Identifying Leaks in GC and GC/MS Systems

HiQ laboratory gas generators.

DETERMINATION OF TETRAHYDROTHIOPHENE IN AMBIENT AIR BY GAS CHROMATOGRAPHY WITH A PFPD DETECTOR COUPLED TO A PRECONCENTRATION TECHNOLOGY

Varian 325-MS LC/MS Quadrupole Mass Spectrometer Pre-installation Instructions

THE PMI AUTOMATED GAS/HELIUM PYCNOMETER PYC-G100A

Determination of Selected ASTM Perfluorinated Compounds (PFCs) Using the Shimadzu LCMS No. LCMS-083. No. SSI-LCMS-083

Toxicology Gas Chromatography-Mass Spectrometry (GC-MS)

Residual Gas Analysis Systems for Industry

The Tekran Series 2600-IVS Difference!

Series Environmental Chambers

Automated Low Background Solid Phase Extraction of Perfluorinated Compounds in Water. Ruud Addink Fluid Management Systems Watertown MA

Now it is. easy to switch. CHS TM Steroid Profiling kit and software. Brochure not for distribution in the USA and Canada

Customer Responsibilities

UltiMate 3000 Viper Capillary Kits for Intelligent LC (LCi) System Solutions

Automated Determination of Dissolved Gases in Water Anne Jurek. Abstract: Discussion:

FINAL REVISED TECHNICAL SPECIFICATION OF INDUCTIVELY COUPLED PLASMA MASS SPECTROMETER (ICP-MS) WILL BE AS FOLLOWS:- GENERAL SPECIFICATIONS

Commercial Practice Test Method Internal Vapor Analysis of Hermetic Devices

Your local gas generation partner. Precision series Modular gas generation solution for GC.

GCMSD-Headspace Analysis SOP

Versatility. Accuracy. Compact. Versa. Automated Headspace Vial Sampler

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

Introduction. Experimental

Your local gas generation partner. Precision series Modular gas generation solution for GC.

Quadruple mass spectrometers (transducer type)

FPG8601 Force Balanced Piston Gauge

SOP: Buck Scientific BLC-20P HPLC Operation

The Amsterdam Initiative against Malnutrition

HPLC. Solvent Delivery Module Systems

Real-time Analysis of Industrial Gases with Online Near- Infrared Spectroscopy

Real-time PCB Gas Monitoring System (MOHMS-21GP)

Extend the time window for the detection of low level anabolic androgenic steroids and their metabolites

Pre-installation Checklist

General Specifications: Forensic. Petrochemical Environmental. Lab Quality Analyses in the Field, It Goes with you Anywhere!

Figure 1: Plug in ion inlet of mass spec

Increasing the productivity of ICP-OES with the Thermo Scientific Qtegra ISDS Software

Title: Standard Operating Procedure for Dasibi Model 5008 Gas Dilution Calibrator

Waters Xevo TQD IVD Overview and Maintenance Guide

DEBUBBLERS & DEGASSERS ACTIVE DEBUBBLERS APPLICATION NOTE WHY DEGAS YOUR MOBILE PHASE? PAGE 177 STAND ALONE DEGASSERS PAGE 175 PAGE 178

EasyLine Continuous Gas Analyzers. So smart, they re simple

UWPR. LC-MS setup. Before you connect your trap and column. Connecting your trap and column

Connectors. SECTION 2 OF 3 SECTIONS ON CONNECTORS VHP Tees and Crosses. Top Seller SEE STARRED PRODUCTS. VHP Tees & Crosses for Capillary Tubing

The HumiPyc - Model 1 - Gas Pycnometer; Density, Moisture, Permeation Analyzer; RH sensor Calibrator

Environmental Petrochemical, Pharmaceutical, Foods & Flavors, Chemicals, Personal Care, Forensics,...and more!

Simplified Backflush Using Agilent 6890 GC Post Run Command Application Note

no peaks missing peaks too small peaks increasing retention decreasing retention

Purpose and Scope: Responsibilities: Warnings and precautions: Background Beers law

BEST KNOWN METHODS. Transpector XPR3 Gas Analysis System. 1 of 6 DESCRIPTION XPR3 APPLICATIONS PHYSICAL INSTALLATION

Ensuring Best Possible UHPLC Performance Through an Innovative Capillary and Fitting Design

Osmometers. Product Selection Guide. Wissenschaftliche Gerätebau Dr. Ing. Herbert Knauer GmbH Hegauer Weg Berlin

Detector Carrier Gas Comments Detector anode purge or reference gas. Electron Capture Nitrogen Maximum sensitivity Nitrogen Argon/Methane

Markes Thermal Desorption Systems Site Preparation Page 1 of 8


Xevo TQD IVD. Overview and Maintenance Guide. Copyright Waters Corporation 2016 All rights reserved IVD Revision C

Extended Application Note

sorting solutions osx separator series

LC, RSLC, Bio RS and Dual Gradient Systems

High Performance Mass Spectrometers

CO 2. (R744) Service Station Presentation. Contents. Goals Basic functions Specification Recovery R477 Vacuum Charge Safety Other features Prototype

ONH836 Series: Oxygen/Nitrogen/Hydrogen by Inert Gas Fusion

Multiple Gas#5 GC configuration Jan 2016

1)! DO NOT PROCEED BEYOND THIS MARK

Supporting Information for Micro-Collection of. Gases in a Capillary Tube: Preservation of Spatial

PHOENIX L300i Best-in-class Helium Leak Detectors

Sorbent Pen Heavy & Labile SVOC s Taints, Off-Flavors, Odors

Precisely HPLC. Hints, Tips, Guidelines and Important Considerations. Presenters: Wilhad Reuter / Tom Breslin

Transcription:

Revised Specifications for Liquid Chromatography Mass Spectrometry (LC-MS/MS ) Triple Quadrupole Specification for Ultra-Fast Liquid Chromatography system Solvent Delivery 1) A quaternary Pump system for using four solvents with integrated System Degasser where a user can choose up to four solvents in combination. 2) Flow Rate Range: - 0.001 to 5 ml/min, with 0.001 ml/min increments. 3) Flow Rate precision: - 0.07% RSD 4) Operating Pressure: - The LC Should handle Maximum Operating Pressure must be 15,000 psi up to 1 ml/min., upto 9,000 psi up to 2 ml/min per pump or above (higher operating pressure are desired) 5) Flow rate accuracy: - ± 1% 6) Solvent selection valve should be quoted 7) Delay Volume :- 400 μl 8) UHPLC capable to support 5 u to STM column Auto Sampler 1) Should have overlapped injections. 2) Should have facility to hold multiple vials. 3) Capacity to hold more than 100 vials of 2 ml in the same auto sampler. 4) Carryover should be < 0.004 % 5) 0.1 20 µl standard injection range up to 1300 bar pressure. 6) Precision typically < 0.30% 7)Design must ensure isolation of electrical components from liquid flow path. 8)Needle should be stainless steel or peak needle; Quote for minimum 4 needles. Column 1) Thermostatted Column Compartment Compartment 2) Preferably have capacity to hold 3-4 columns simultaneously or other possible combination 3) Temperature stability ±0.1 C 4) Temperature range fromroom temperature to 60 C 5) A-Line Quick Connect UHPLC column fittings for dead-volumefree fluidic connections Page 1 of 5

Column & Vials C18 3.0 x 100 mm, STM C8 4.6 x 75 mm, 3.5 μm C18 4.6 x 150 mm, 5 μm Minimum 3 of each above should be quoted. PDA detector Wavelength range: 190-700 nm, settable in 1nm increments. Linearity of 5% at 2.0AU Noise specifications: 0.2 x 10-5 AU High brightness lamp with a guaranteed life of 2000 Hours Only one lamp source and Lamp Optimization software Acquire data up to 80Hz The detector must provide comprehensive and interactive diagnostic information on the unit Low volume long path length flow cells for optimum performance as well as the highest sensitivity & should be optimized for use with latest sub 2 micron particle size technology. Flow cell should have 10mm path length with no more than 500nL volume. Specifications for a Triple (tandem) Quadrupole MS system Mass Analyzer The MS system should be a Tandem Quadrupole MS system, capable of carrying out MS and MS/MS experiments. The instrument should have the following minimum specifications Mass Range The instrument should have a mass range from 2 to 2000 m/z or better Interface Interface should have a unique technology to enable increase ion sampling and transmission from Electrospray into the ion focusing optics. Interface should maintain cleanliness of ion optics and capable of handling large batches of complex samples. It should be capable of ambient temperature operation and without complex apertures to maintain structural integrity of thermally labile and fragile molecules. Scan rate 12000 Da/sec or better Dynamic range It should have linear dynamic range of at least 5 orders of magnitude or better Mass Stability < 0.1 Da in 24 hrs Sensitivity Electrospray (ESI +Ve) at Unit Resolution and high resolution: Performance Sensitivity of Electrospray in MRM mode for Reserpine 1pg on column the instrument must have S/N > 70000:1 or better Polarity Switching Switch from positive to negative polarity in 50 msec or better Time Page 2 of 5

Collision cell Ionization source Detector Modes of operation Operating Software Auto tune Single point of control Confined collision cell capable of high energy fragmentation, producing reproducible MS/MS spectra should have a minimum dwell time of 1 ms Electrospray ion source should maximize ion generation while minimizing the amount of chemical noise generated and transmitted into the vacuum system. Should come with an orthogonally oriented, advanced ESI source with improving sensitivity. It should have a low maintenance interface which should not require frequent cleaning. The ion source should be designed for maximum ionization efficiency. APCI Source with easy switching needs to be quoted. APPI source also be quoted. High-energy conversion dynode or PMT or CEM etc. SIM, Precursor ion scan, Product Ion Scan, MRM, neutral loss and neutral gain experiments, and triggered MRM Etc The system should have all the necessary software to perform following functions: The software shall support change of domain user even during acquisitions without impacting the runs in progress. Automated calibration and quantitative optimization Automated MS to MS/MS switching during a single run with user selectable criteria. Perform alternating Positive/Negative scans in one run Automated quantitation and reporting of acquired samples. Automated Method Development software Simultaneous Quantitation and Confirmation The software also provides tools for work in 21CFRPart11 compliant environments, including user login, session lock, configurable user roles, electronic signatures and a comprehensive audit trail. Password protected for multilevel users Logging of LC-MS acquisition parameters. The Mass detector should have options of changing the source from standard ESI to Dedicated APCI sources. Automated optimization of ion optics and mass axis calibration. HPLC and MS instrument should have a single point of control for both the system and preferably from same manufacture Page 3 of 5

Solid phase extraction system Gas Generator Computer Hardware In line degassing unit Sonicator A suitable solid phase extraction system having positive pressure loading and elution of sample and solvents with parallel /sequentenial evaporation. Well equipped with gas regulator and Gas gauge. The extractor should rinse the sample with the extracting solvents and wash all retained analytes on to cartridges. Extraction for liquid samples sizes of 10 ml to 20 ml with extractable of active ingredients from plasma, plant and microbial extracts. Accommodates various sizes of cartridges (normal/reverse phase) with transport adaptor. Should also have provision for high throughput. Interchangeable racks for providing maximum flexibility. Each sample must have its own stop cock to control the flow No cross contamination All waste must transfer to waste vessels A suitable gas generator capable of providing all the gases at the required purity, pressure and flow rate for the Mass Spectrometer must be quoted. The Nitrogen Generator should have a self-contained Nitrogen Generator with a built-in Air Compressor must utilize membrane technology to selectively remove oxygen, moisture and other gases to leave clean, dry, phthalate-free nitrogen. Nitrogen Generator should be compatible for external TLC-MS Interface (atleast 30 l/min max flow rate)the Nitrogen Generator should fully comply with the UPLC and MS system. All the required accessories such as arrangement for required gas supply through gas generator/cylinder, compressor, and essential for operation of the instrument should be supplied along with the instrument. If required additional gas cylinder with the regulator must also be quoted. High power latest processor CPU, USB Optical Scroll Mouse, USB Internet Keyboard System Documentation Kit, 24 inch LED Monitor In line degasser having capacity to remove 95% of the air from solvent Degassing Sonicator of Indirect type with capacity to sonicate 0.5 L liquid. Page 4 of 5

Warranty/CMC UPS Instruments should be covered under comprehensive warranty (spares & servicing) for 5 year from the date of installation. The suitable online UPS having 30 minutes or more back up Page 5 of 5