CONSTANT PRESSURE SYRINGE PUMP

Similar documents
Research Grade Blood Pressure Transducer

Large Animal Volume Controlled Ventilator

User s Manual. VentElite Publication REV-1.1

Features. Main Voltage: Vdc. Input Control Signal: 0-5 Vdc or 4-20 madc (Sourcing) Monitor Output Voltage: 0-5 Vdc or 4-20 madc (Sourcing)

Minipuls evolution fitted with three 4-channel Medium Flow pump heads. one 4-channel Medium Flow pump head and one 2-channel High Flow pump head

RM-80 respiration monitor

Design Features. General Description

PPC4E Pressure Controller/Calibrator Superior rangeability and reliability

Specifications...Easy CLIA Classification: Sample Type: Blood gas analyzer operation has never been simpler Sample Size: Measured Parameters PCO2

Additel 780 Series Pressure Controller

Additel 780 Series Pressure Controller

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

GFM. Typical Aluminum GFM Mass Flow Meter NIST MASS FLOW METERS. Principles of Operation. Design Features

BUBBLER CONTROL SYSTEM

BUBBLER CONTROL SYSTEM

HumiSys HF High Flow RH Generator

Pneumatic high-pressure controller Model CPC7000

Additel 761 Automated Pressure Calibrators Selection Guide

BETTER SAMPLE CARE. Spark Holland introduces. SPH1299 UHPLC Gradient Pump

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

The HumiPyc - Model 1 - Gas Pycnometer; Density, Moisture, Permeation Analyzer; RH sensor Calibrator

Versatility. Accuracy. Compact. Versa. Automated Headspace Vial Sampler

Accurate, easy to use and reliable: Easy to use control panel. Clear, backlit LCD display:

Additel 761 Automated Pressure Calibrators Selection Guide

Additel 761 Automated Pressure Calibrators

Precision pressure sensor Basic version Model CPT6020

Series Ruska Digital Pressure Indicator. GE Sensing & Inspection Technologies. Features

CRRT with Prismaflex LEADS TO More Flexibility, Ease of Use and Safety

Pneumatic high-pressure controller Model CPC7000

EPP4 Pressure Regulator Basic G 1/4"

TSE Blood Pressure Monitor Invasive series

Abdominal Organ PERFUSION SYSTEMS. Liver Kidney Mesenteric Bed Intraluminal Vessel Perfusion

Automatic Isokinetic Sampler. ST5 Evo

High-speed pressure sensor Model CPT6140

Mouse and Rat Tail Cuff Blood Pressure Systems from 1-24 Animals. Mouse rat tail cuff blood pressure system components

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

Precision digital pressure gauge Model CPG1000

Additel 761 Automated Pressure Calibrators

Analogue and Digital Mass Flow Meters and Controllers for Gases MASS-STREAM

LUMAZOTE T ECHNICAL BRO CHU RE

The HumiPyc ( Model 2) - Gas Pycnometer; Density, Moisture, Permeation Analyzer; Filter Integrity Tester; RH sensor Calibrator

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

SENSAPHONE APPLICATION NOTE. Functions: C Programming, Pump Control, Data Logging

AC : MEASUREMENT OF HYDROGEN IN HELIUM FLOW

ADT 761 Automated Pressure Calibrator

Mass Flow Meter (MFM) for gases

Additel 780 Series Pressure Controller

Additel 761 Automated Pressure Calibrators

Industrial pressure controller Model CPC4000

HUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation

Blood Parameter Monitoring System 550

DCS Series 1 kw, 1.2 kw, & 3 kw


MCQ Gas Blender 100 Series 3 Channels Gas Mixer

HyDefinition HD4070. Plasma Arc Cutting / Marking System. Product Configuration Manual Revision

X-Flow Mass Flow Controller 授权代理 : 北京品超思瑞科技学院公司

Model GFC 7000T CO 2 Analyzer (Addendum to GFC 7000TA Manual, PN 07272)

A high flying simplicity DUAL SOFT BAG INJECTION SYSTEM

Model 601CV. Mass Flow Controller. Product Features:

Sorensen DCS Series. 1 3 kw V A. General Purpose Systems Power Supply

FPG8601 Force Balanced Piston Gauge

combustion efficiency monitoring General Purpose Applications Flue gas oxygen analyzers Combustion & Environmental Monitoring An Company

Mass Flow Controller (MFC) for Gases

Osmometers. Product Selection Guide. Wissenschaftliche Gerätebau Dr. Ing. Herbert Knauer GmbH Hegauer Weg Berlin

BUYER S GUIDE AQUAlogger 530WTD

UNDERSTANDING, ACCELERATED

User Manual MFCS TM -EZ

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

C-Flow Coriolis Mass Flow Meters

INSTRUCTION MANUAL. FLOW CONTROL DRAWERS MANUAL / PLC CONTROL SERIES Model Version Perma Pure LLC Tel:

BAROMETER PRESSURE STANDARD PRESSURE CONTROLLER

Miniature Electronic Pressure Controllers. Precision Fluidics

AUTOMATIC HOSE TEST UNIT, TYPE SPU

Hand-held pressure calibrator with integrated pump Model CPH6600

Mass Flow Controller (MFC) for Gases

Mass Flow Controller (MFC) for Gases

STARLOG. Capacitive Water Depth Probe

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter

CO, NO, NO 2, NO x, SO 2, CH 4, HCl, CO 2 & H ² O. Extractive low cost, low maintenance devices for continuous process and emissions monitoring.

Hydraulic hand test pump Models CPP700-H and CPP1000-H

The instrument will process the samples one by one till all the samples have been cleaned up.

Digital pressure gauges

HPFM GEN3 - High Pressure Flow Meter

AMS 6915 Board mount pressure sensor with digital output (I²C)

Mass Flow Controller (MFC) for Gases

NT High-temperature flowmeter model Simultaneous flow and pressure outputs for high-temperature applications

Used with Dissolution Tester for Fraction and Flow Measurements

Pressure transmitter PASCAL Ci4

KERN EG/EW Version /02

P9000 DESCRIPTION. For parts requiring RoHS compliance, please contact factory. P February /6

PRESSURE SENSOR - ABSOLUTE (0 TO 700 kpa)

WL16 WATER LEVEL LOGGERS Submersible pressure transducer and USB datalogger combination

Electronic gas volume corrector model DGVC-04

Mass Flow Controllers

MEGAS 2.0. Gas analysis with direct C-Level Calculation and Bus-Connection. Data sheet

combustion efficiency monitoring Flue gas oxygen analyzers General Purpose Applications Combustion & Environmental Monitoring

Oil Diagnostic Systems. Online and bottle measurement Mobile and stationary operation Lab quality accuracy e

This multi-functional device allows the determination of up to six quality parameters with only one measurement:

SonoMeter 30 Energy Meters

Operating Instructions

Transcription:

A NEW TECHNOLOGY BREAKTHROUGH CONSTANT PRESSURE SYRINGE PUMP ENABLES CONTINUOUS PRESSURE-CONTROLLED INFUSION USE IN CONSTANT FLOW OR CONSTANT PRESSURE MODE ENHANCES SAFETY FOR SENSITIVE EXPERIMENTATION COMPATIBLE WITH A WIDE RANGE OF PRESSURE TRANSDUCERS AUTOMATICALLY ADJUSTS FLOW RATE TO MAINTAIN CONSTANT PRESSURE F O R YO U R F LU I D I C ULTIMATE PUMP A P P L I C A T I O N

INTRODUCTION PHDULTRA CP Constant Pressure Syringe Pump Technology Breakthrough! Harvard Apparatus is proud to introduce the syringe pump. This pump is the first of its kind to allow operation under constant pressure or constant flow. Historically, the only means available to dispense at constant pressure has involved the use of various amplifiers and other accessories/ software. The, when combined with virtually any commercially available pressure transducer/amplifier combination with 0-10V DC analog output, results in a constant pressure dispensing system. This sytem can deliver fluids with an applied force up to 1,000 lbs. Our user-friendly touch screen interface allows for simple control of either constant pressure or constant flow-based applications. 88-3016 4400 Infusion/Withdrawal Programmable 88-3015 Infusion/Withdrawal Programmable Superior Functionality Using Harvard Apparatus syringe pump technology and software-controlled pressure monitoring, the is able to maintain a user-defined system pressure ±2%. A user-adjustable sensitivity setting allows for the customization of the system response time necessary to attain the set pressure. The allows the user to set pressures in the units of their choice including mmhg, kpa, and psi. Constant Pressure Applications Include: Short-term organ perfusion studies that require the maintenance of physiologic conditions. Introduction of chemical reactants in a controlled manner. Ocular injections and perfusions. Small animal whole-body perfusions. Constant pressure microfluidic mixing. Administration of genetic material into organs without viral vectors. And Many More! To order call 1-508-893-8999 email techsupport@harvardapparatus.com www.harvardapparatus.com

SYRINGE PUMP SOFTWARE PRECISION MONITORING OF PRESSURE & FLOW Harvard Apparatus Constant Pressure Monitoring Software. Pressure & Flow Rate Data Data can be monitored via RS-232 from the to a PC In practice, the 0-10V analog output of a pressure transducer amplifier is connected to the analog input on the rear panel of the pump. The amplifier or signal conditioner can be provided by the customer, or accomplished with various tranducers and amplifiers available from Harvard Apparatus. The pressure range may be scaled to fit the available transducer voltage output for systems that output less than 10 V. While in constant pressure mode, in addition to the set and actual pressure, the pump displays the flow rate. This data may be output for further analysis with a variety of data acquisition packages. Accuracy & Reproducibility Of course, the may be used in flow mode with its worldrenowned accuracy and reproducibility. All pumps are infuse/withdraw models. When used in flow mode, these offer features such as method storage and flow programming functions to allow the user to create simple to complex methods. The is available in a variety of configurations to suit the desired pressure or flow rate ranges. To order call 1-508-893-8999 email techsupport@harvardapparatus.com www.harvardapparatus.com

ACCESSORIES SUPERIOR SELECTION OF ACCESSORIES Essential Application Tools The can work with any pressure transducer and amplifier that will output a 0-10V or similar signal. Harvard Apparatus carries a wide variety of pressure transducers and amplifiers to suit your particular application. Our most popular physiological pressure transducer is our APT-300, a fluid-filled unit with a pressure range of ±300mmHg and a sensitivity of 5µV/V/mmHg (±1%). This has an easily replaceable transducer head. For low pressure applications, such as maintaining the pressure in an eye, we have the P75 Venous Pressure Transducer. This pressure transducer has a pressure range of ±75mmHg and a sensitivity of 1mV/mmHg. When the customer requires a separate amplifier, the unit of choice is the model 601 Transducer Amplifier Module, or TAM-A. As a PLUGSYS module, this DC Bridge Amplifier requires the use of a PLUGSYS housing with a power supply. Cases holding 2, 5, or 10 modules are available. APT-300 with Minicase Blood Pressure Transducer P75 Samba Sensor Applications requiring the use of solid-state pressure catheters (as small as 1Fr up to 7Fr) are also compatible. Millar Transducers interface directly with the TAM-A amplifier. Harvard Apparatus provides a full line of accessories to complement any fluidics experiment, as well as syringes in a variety of styles and sizes. These include Harvard Apparatus Stainless Steel syringes for high pressure applications as well as Hamilton microliter and Gastight syringes in a variety of sizes. Tubing choice is essential to any fluidics set-up. The length, type and stiffness of your tubing will affect the flow quality and accuracy of any experiment. Harvard Apparatus provides a full line of Tygon tubing, PEEK tubing and even can provide custom lengths of stainless steel tubing. Please contact us for more information. 200 ml 100 ml Harvard Apparatus High Pressure Stainless Steel Syringes Research Grade Blood Pressure Transducer 50 ml 2.5 ml 20 ml 8 ml To order call 1-508-893-8999 email techsupport@harvardapparatus.com www.harvardapparatus.com

SPECIFICATIONS & ORDERING INFORMATION FAMILY OF SYRINGE PUMPS Model PHD ULTRA CP Remote 4400 4400 Remote HPSI Remote PHD ULTRA XF-CP Remote Type single syringe, single syringe, Flow Accuracy ±0.25% ±0.25% ±0.35% ±0.35% ±0.5% ±0.5% Pressure Accuracy < ±2% < ±2% < ±2% < ±2% < ±2% < ±2% Syringe Size, min/max 0.5 µl to 140 ml 0.5 µl to 140 ml 0.5 µl to 140 ml 0.5 µl to 140 ml 20 ml to 200 ml 20 ml to 200 ml # Syringes 2-10 2-10 1 1 4 4 Flow Rate: 88-3316 4400 Remote 88-3113 HPSI Remote Minimum 1.56 pl/min 1.56 pl/min 3.06 pl/min 3.06 pl/min 50.70 nl/min 50.70 nl/min Maximum 215.8 ml/min 215.8 ml/min 215.8 ml/min 215.8 ml/min 144.1 ml/min 144.1 ml/min Connectors: USB (PC-to-Pump) Type B Type B Type B Type B Type B Type B RS-232 (PC-to-Pump) 9-Pin D-Sub 9-Pin D-Sub 9-Pin D-Sub 9-Pin D-Sub 9-Pin D-Sub 9-Pin D-Sub RS-485* (Pump-to-Pump) IEEE-1394, 6 pos IEEE-1394, 6 pos IEEE-1394, 6 pos IEEE-1394, 6 pos IEEE-1394, 6 pos IEEE-1394, 6 pos I/O & TTL 15-Pin D-Sub 15-Pin D-Sub 15-Pin D-Sub 15-Pin D-Sub 15-Pin D-Sub 15-Pin D-Sub Average Linear Force 34 kg (75 lbs) 34 kg (75 lbs) 91 kg (200 lbs) 91 kg (200 lbs) 200 kg (433 lbs) 454.5 kg (1,000 lbs) Maximum Pressure (with 100 ml Syringe) 50 psi 50 psi 135 psi 135 psi 290 psi 670 psi Dimensions 30.5 x 21.6 x 17.8 cm 30.5 x 21.6 x 10.6 cm 30.5 x 21.6 x 10.6 cm 30.5 x 21.6 x 18.5 cm 30.5 x 21.6 x 10.6 cm 30.5 x 21.6 x 10.6 cm Control Box (12 x 8.5 x 7 in) (12 x 8.5 x 4.3 in) (12 x 8.5 x 4.3 in) (12 x 8.5 x 7.3 in) (12 x 8.5 x 4.3 in) (12 x 8.5 x 4.3 in) Dimensions 30.5 x 14 x 16.5 cm 30.5 x 14 x 17.8 cm 41.9 x 30.5 x 19.1 cm 41.9 x 30.5 x 19.1 cm N/A N/A Remote Box (12 x 5.5 x 6.5 in) (12 x 5.5 x 7 in) (16.5 x 12 x 7.5 in) (16.5 x 12 x 7.5 in) Weight 4.5 kg (10 lb) 4.8 kg (10.5 lb) 5.4 kg (12 lb) 7.7 kg (17 lb) 13.6 kg (30 lb) 20.9 kg (46 lb) CONSTANT PRESSURE S Y R I N G E P U M P Voltage Range 100-240 VAC; 50/60 Hz 100-240 VAC; 50/60 Hz 100-240 VAC; 50/60 Hz 100-240 VAC; 50/60 Hz 100-240 VAC; 50/60 Hz 100-240 VAC; 50/60 Hz Order # 88-3015 88-3315 88-3016 88-3316 88-3113 88-3314 * Option for RS-232 (RJ-11, Pump-to-Pump) must be ordered at time the pump is ordered. ** Maximum pressure will vary with syringe size and applied force To order call 1-508-893-8999 email techsupport@harvardapparatus.com www.harvardapparatus.com

Contact Information CONSTANT PRESSURE S Y R I N G E P U M P UNITED STATES Harvard Apparatus 84 October Hill Road Holliston, MA, 01746, USA phone 508.893.8999 toll free 800.272.2775 (USA Only) fax 508.429.5732 techsupport@harvardapparatus.com www.harvardapparatus.com Warner Instruments 1125 Dixwell Avenue Hamden, CT, 06514, USA phone 203.776.0664 toll free 800.599.4203 (USA Only) fax 203.776.1278 support@warneronline.com www.harvardapparatus.com CANADA Harvard Apparatus Canada Attn: Sales Department 6010 Vanden Abeele Saint-Laurent, Quebec, H4S 1R9, Canada phone 514.335.0792 800.361.1905 (Canada only) fax 514.335.3482 sales@harvardapparatus.ca www.harvardapparatus.ca FRANCE Harvard Apparatus, S.A.R.L. Attn: Sales Department 6 Avenue des Andes Miniparc Bat. 8 91952 Les Ulis Cedex, France phone 33.1.64.46.00.85 fax 33.1.64.46.94.38 info@harvardapparatus.fr www.harvardapparatus.fr GERMANY Hugo Sachs Elektronik / Harvard Apparatus, GmbH Gruenstrasse 1 D-79232 March-Hugstetten, Germany phone +49 (0)7665 92000 fax +49 (0)7665 920090 info@hugo-sachs.de www.hugo-sachs.de SPAIN Panlab, S.L. / Harvard Apparatus Spain C/Energia, 112 08940 Cornellà, Barcelona, Spain phone 34.934.750.697 (International Sales) phone 934.190.709 (Sales in Spain) fax 34.934.750.699 info@panlab.com www.panlab.com SWEDEN CMA Microdialysis, AB Box 2 SE-171 18 Solna phone +46 8 470 10 00 fax +46 8 470 10 50 cma@microdialysis.se www.microdialysis.com UNITED KINGDOM Harvard Apparatus, Ltd. Attn: Sales Department Fircroft Way, Edenbridge Kent TN8 6HE, United Kingdom phone 44.1732.864001 fax 44.1732.863356 sales@harvardapparatus.co.uk www.harvardapparatus.co.uk www.harvardapparatus.com