RELIEF CAPACITY CURVES

Similar documents
Design, Manufactured and Stocked in Canada The Series 6000 is manufactured and stocked for quick delivery at Hawkeye s Edmonton plant.

The most common terms rating air flow capacity are ICFM, FAD, ANR, SCFM or nl/min

Quick Reference Technical Data

SERIES 30. Spring Operated Tank Blanketing Valve PROTECTOSEAL.

Noth American 7347 High Pressure Gas Regulators

SERIES 4000 MARSH HAWK TRV

SERIES 10. Pilot Operated Tank Blanketing Valve, 2" PROTECTOSEAL.

3 1 PRESSURE. This is illustrated in Fig. 3 3.

pumping gases JET PUMP TECHNICAL DATA

94270 Vapor Guard Tank Blanketing Valve Vapor Guard Tank Blanketing Valve What is Tank Blanketing? Features How does it work?

OVERVIEW. Flow Coefficient C v. Operating Conditions. Specific Gravity

Pressure Technical Information

API Standard Venting Atmospheric and Low-Pressure Storage Tanks: Nonrefrigerated and Refrigerated

SIZING THE EXTROL DIAPHRAGM-TYPE HYDRO-PNEUMATIC TANK

The Shand & Jurs Model Vapor Guard Tank Blanketing Valve

S300 Series. Valve Link. Features. Fisher Controls

Chapter 1: Basic Concepts of Pneumatics

Technical Committee on LP-Gas at Utility Gas Plants

Pressure Control. where: p is the pressure F is the normal component of the force A is the area

CHAPTER 3 : AIR COMPRESSOR

ANDERSON GREENWOOD TANK BLANKETING REGULATORS

SIZING AND CAPACITIES OF GAS PIPING

TUTORIAL. NPSHA for those who hate that stuffy word. by Jacques Chaurette p. eng. copyright 2006

VARIABLE ORIFICE BALANCING VALVE PN 25 TECHNICAL DATA SHEET. Approved by*: Main features:

Before we begin, let us recall some important information about the metric measuring system.

09 - Choosing /sizing a cylinder and valve

SIZING AND CAPACITIES OF GAS PIPING

Engineering / Technical Section

Influence of Overpressure in Pressure Vacuum Safety Valves on Emission Reduction and Explosion Risk Minimization of Atmospheric Storage Tanks

Device Description. Operating Information. CP Q (eq. 1) GT. Technical Bulletin TB-0607-CFP Hawkeye Industries Critical Flow Prover

Application Notes for Valve Sizing Sizing valves for steam service with the aid of sizing charts

Model TB 3-16 TECHNICAL BULLETIN. Secure-Gard Pilot Operated Vent Valve (POVV) BENEFITS TYPICAL APPLICATIONS FEATURES

Practical Guide. By Steven T. Taylor, P.E., Member ASHRAE

Type Y692 Gas Blanketing Regulator System

Application Worksheet

T208VR Series Tank Blanketing Vacuum Regulator

SIZING AND CAPACITIES OF GAS PIPING Reserved

The Hoffman Specialty Series 2000 consists of main

PRESSURE. 7. Fluids 2

SG TF. Q = 963 Cv (P1 - P2)(P1 + P2) TECHNICAL INFORMATION. Flow Q (GPM)

Exhibit 4. Determination of Static Pressure Performance of the Healy Clean Air Separator (Executive Orders VR-201-N and VR-202-N)

Modeling a Pressure Safety Valve

Operating Guidelines for PermSelect Modules Liquid Contacting

Cecomp. Electronics. Test. Measure. Monitor. Transmit. Alarm. Cecomp High Perfor. formance Digital Pressur

DO NOT PRINT THIS PAGE

PENBERTHY SERIES LM, ELL, FL, GL, GH, U, L AND 2NC FOR PUMPING GASES

Dry Plant Measurement Information

The Kinetic-Molecular Theory of Gases based on the idea that particles are always in motion

Type 299 Pressure Reducing Regulators

SAMPLE RH = P 1. where. P 1 = the partial pressure of the water vapor at the dew point temperature of the mixture of dry air and water vapor

TOPIC: KNOWLEDGE: K1.01 [2.5/2.7] An atmospheric pressure of 15.0 psia is equivalent to... A psig. B psig. C psig.

SIZING AND CAPACITIES OF GAS PIPING

3776B FLANGED PRESSURE INDEPENDENT CONTROL VALVE (P.I.C.V.) PN 16 TECHNICAL DATA SHEET. Main features:

Pressure Measurement

Instruction Manual 742 5/1/2009. Eclipse Ratio Regulators ES Series Version 1

Modulating Valves for Atmospheric, Infrared, and Direct Fired Burners

Year 9 notes part 5. Contents

GP1 & GP2. Electropneumatic Regulators FOR PRESSURE CONTROL TO 1,000 PSI

North American 7337A/B/C-4 High Pressure Gas Regulators

Pressure measurement explained

DIRECT AND INVERTED PENDULUMS. Model DP & RP. Roctest Limited, All rights reserved.

SIZING AND CAPACITIES OF GAS PIPING

Maximum Pressure Differential and Maximum Inlet Pressure for Various Soft-Seated Valve Materials* Introduction. Body Pressure Ratings

3-way control valves VK 3

Types ACE95 and ACE95Sr Tank Blanketing Valves

Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators

for Pleasant & Healthy Air-Distribution ISO 9001:2000 Linear Slot Diffusers Product Bulletin 133-D

PTF4 Pivotrol Pump (patented) version Dual Mechanism - Pressure Powered Pump

A centrifugal pump consists of an impeller attached to and rotating with the shaft and a casing that encloses the impeller.

V248 Series 3-Way Pressure-Actuated Water-Regulating Valves for High-Pressure Refrigerants

Instruction Manual No. 742, 8/98

Types ACE95 and ACE95Sr Tank Blanketing Valves

1805 Series Relief Valves

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified

KNOWN: Mass, pressure, temperature, and specific volume of water vapor.

Chapter 13 Gases, Vapors, Liquids, and Solids

ART24 Differential Pressure Control Valve (DPCV)

7 MEASURE. Before you start. Objectives

Advanced Management of Compressed Air Systems Pre-Workshop Assignment

V248 Series 3-Way Pressure-Actuated Water-Regulating Valves for High-Pressure Refrigerants

EXPERIMENT 8 Ideal Gas Law: Molecular Weight of a Vapor

PVA PIAB Vacuum Academy

PROTEGO Braunschweiger Flammenfilter GmbH

Chapter 3: Fluid Statics. 3-1 Pressure 3-2 Fluid Statics 3-3 Buoyancy and Stability 3-4 Rigid-Body Motion

1800CPB2 Service Regulators Maximum Inlet Pressure 125 PSIG

Module 2, Add on Lesson Depth Sensor. Teacher. 90 minutes

PRO-50 Instrument Supply Regulator

North American 7339 High Pressure Gas Regulators

VAPOR CONTROL SYSTEMS QUALITY, DEPENDABILITY, SERVICE. REPUTATION BUILT ON. Valve Concepts, Inc. com. A Cashco, Inc.

The Discussion of this exercise covers the following points: Pumps Basic operation of a liquid pump Types of liquid pumps The centrifugal pump.

Features. General application. Technical data

Energy Drilling Prospects

Type R622 Pressure Reducing Regulator

Pneumatic High-Speed Pressure Controller Model CPC3000

POP Safety Valve. POP Safety Valve INTRODUCTION DEFINITIONS

Anderson Greenwood Type 4142 piped away pressure relief valves

Gauge Pressure, Absolute Pressure, and Pressure Measurement

Fundamentals of Compressed Air Systems. Pre-Workshop Assignment

UNIK 5600/5700 Marine Certified Pressure Sensing Platform

Storage Systems and Accessories

Transcription:

E (800) 910-4295 www.hawk-eye.com TANKAGE VENTING RELIEF CAPACITY CURVES SERIES 6000 PVRV SERIES 4000 MARSH HAWK TRV SERIES 5000 EPRV RE SERIES 200 & 300 TVTH RE

INTRODUCTION INTRODUCTION A relief capacity curve provides the flow relieving capacity of a particular venting device by plotting the flow rate through the device on the horizontal, or x-axis against the tank pressure specifically pressure at the inlet of the vent, on the vertical or y-axis. These curves can be used to size a venting device for a given application. REQUIRED INFORMATION The type and configuration of the required device must be known in order to size a vent. This information is often integral to the purpose of the vent. For example, if the vent is for emergency pressure relief, an EPRV will likely be selected, if the relieved vapors must be collected or processed then a Pipe-Away PVRV will be selected. Refer to corresponding brochures and technical bulletin TB-1217-TV for assistance in vent selection. A minimum of three quantities based on the design of the tank, process or application are required to size a relief device: required relieving flow capacity for pressure and/or vacuum; maximum relieving pressure/vacuum; and, set pressure/vacuum. Pressure relief and vacuum relief are sized separately. HOW TO USE RELIEF CAPACITY CURVES 1. Use the device and size estimation charts in conjunction with the table of contents to find the type and configuration of the device required. 2. Begin sizing by turning to the pressure flow curve (if applicable) of the smallest available size for the selected device. 3. Flow curves for multiple set pressures/vacuums are displayed on each graph. Identify the flow curve that corresponds to the required set pressure/vacuum. 4. On the vertical axis (Tank Pressure) find the maximum relieving pressure and draw a horizontal line at this pressure until it crosses the previously identified flow curve. 5. At the point where the flow curve and horizontal line cross, draw a vertical line down to the horizontal axis (Flow Rate through Device). The number on this axis represents the flow rate through the device at the maximum relieving pressure. 6. If the flow rate through the device is lower than the required relieving capacity, repeat steps 3-5 for the next larger vent size until the flow relieving capacity of the vent exceeds the required relieving capacity. Notes: i. If the required relieving capacity cannot be satisfied by the largest available size in the selected venting class, a larger venting class, such as an EPRV, or multiple vents can be added to meet the required relieving capacity. ii. iii. iv. If the minimum required vent size differs as a result of pressure sizing and vacuum sizing, the larger vent of the two must be chosen. The gas type and conditions must be the same between units. Follow appropriate conversion method to convert between gas types and conditions. All pressure readings are provided in gauge pressure (zero-referenced to ambient pressure). UNIT CONVERSIONS - PRESSURE The pressures reported on the capacity charts published by Hawkeye are reported in in ounces per square inch (ozsi). To convert from other pressure units to ozsi, select the appropriate conversion factor from this chart: CONVERSION FACTORS PRESSURE TO OUNCES PER SQUARE INCH (OZSI) (5 SIG- FIG) To Convert From: Multiply by: psi pounds per square inch 0.0625 atm atmsophere 235.14 mbar millibar 0.23206 bar bar 232.06 Pa pascals 0.0023206 kpa kilopascals 2.3206 MPa megapascals 2320.6 kgf/m² kilogram (force) per square metre 0.022757 kfg/cm² kiogram (force) per square centimetre 227.57 mmhg millimetres of mercury (60 F) 0.30939 inhg inches of mercury 7.8363 inh 2 O inches of water 0.57802 Torr Torr 0.30939 Example: Convert 5 kpa to ozsi. From the chart above, the conversion factor is 2.3206. We ll multiply 5 kpa by this number to get the pressure in ozsi. 5 kpa 2.2306 = 11.603 ozsi» 11.6 ozsi UNIT CONVERSIONS - VOLUMETRIC FLOW The flow rates reported on the capacity charts published by Hawkeye Industries are equivalent volumetric flows, in cubic feet per hour, of air at standard conditions, and noted as SCFH (air). Unlike liquid or solid quantities, measuring and reporting gaseous properties is complicated by properties that change as temperature and pressure change. As such, gaseous properties are reported in terms of reference conditions. These are conditions specified by API 2000 7th Edition, Annex D, and may not correspond to other internationally recognized conditions (IUPAC, ISO, etc.). This means that to convert a unit in normal conditions to a different unit in standard conditions, it is a two step process. 1.) Convert conditions 2.) Convert units The first reference conditions, called Standard Conditions, reports the volume of a gas at a pressure of 101.325 kpa absolute [14.696 psia], and at a temperature of 15.56 C [60 F]. Units reported in Standard conditions are prefixed with an S. (eg. SCFM instead of CFM) The other common condition, usually associated with metric units, is Normal Conditions. These report volume of a gas at pressure of 101.325 kpa absolute [14.696 psia] and at 0 C [32 F]. Units reported in Normal conditions are prefixed with an N. (eg Nm3/ hr instead of m3/hr) 2 2

INTRODUCTION INTRODUCTION To convert between normal and standard conditions, multiplying the normal condition property by 1.0281. Example: Convert 1000 Nm³/hr to Sm³/hr We see that the provided volume is in Normal conditions, by the N preceding the volume unit. To convert to an equivalent volume in standard conditions, we multiply by 1.0281 1000 Nm 3/hr 1.0281 = 1028.1 Sm 3/hr Note the units remain the same in these conversions, only the conditions change. To complete the conversion to another unit, i.e. CFH, the appropriate conversion factor from the table below must be used. These conversion factors maintain the same condition of the starting unit. CONVERSION FACTORS VOLUMETRIC FLOW TO CUBIC FEET PER HOUR (CFH) (5 SIG- FIG) To Convert From: CFM cubic feet per minute 60 CFS cubic feet per hour 3600 Multiply by: m³/hr cubic metres per hour 35.315 m³/min cubic metres per minute 2118.9 m³/s cubic metres per second 127130 L/hr litres per hour 0.035315 L/min litre per minute 2.1189 L/s litres per second 127.13 US gph US gallons per hour 0.13368 US gpm US gallons per minute 8.0208 US gps US gallons per second 481.25 Imperial gph Imp/UK gallons per hour 0.16054 Imperial gpm Imp/UK gallons per minute 9.6326 Imperial gps Imp/UK gallons per second 577.96 US bpd US Barrels per day 0.23394 514.05 Sm³/hr 35.315 = 18,153.7 SCFH. Example: Convert 1000 US gph to SCFH There is no reference condition on the starting unit, so we can skip the reference condition conversion. Technically then, our answer will be in CFH, not SCFH. 1.) Convert units From the chart, the conversion factor from US gph to CFH is 0.13368. 1000 US gph 0.13368 = 133.7 CFH. MORE COMPLICATED CONVERSIONS Example: Convert 12 ozsi to Pa The values on the pressure conversion chart are for converting to ozsi, not from. However, we can still use these factors and divide by them instead of multiplying. From the chart, the conversion factor from Pa to ozsi is 0.0023206. To get bar from ozsi, we will divide by this number. 12 ozsi 0.0023206 = 5,171.1 Pa. Example: Convert 20,000 CFH to m³/hr The values on the volumetric flow conversion chart are for converting to CFH, not from. However, we can still use these facts and divide by them instead of multiplying. Note, there is no reference conditions on the units we are working with. From the chart, the conversion factor from m³/hr to CFH is 35.315. To get m3/hr from CFH, we will divide by this number. 20,000 CFH 35.315 = 566.3 m³/hr. Note, if a volumetric flow is provided without a reference condition (i.e not Normal or Standard ) do not perform the condition conversion. However, this does not mean that the end unit does not require a reference condition; please consult engineering in these cases. Example: Convert 500 Nm3/hr to SCFH We see that the provided volume is in Normal conditions, by the N preceeding the volume unit, and we are looking for an answer in Standard conditions. 1.) Convert to standard conditions 500 Nm 3 /hr 1.0281 = 514.05 Sm 3 /hr Example: Convert 5,000 SCFH to Nm³/hr Note, there are reference conditions on the units we are working with, so we will need to take that into account. The factor of 1.0281 we have is to go from Normal conditions to Standard conditions. We can convert from Standard conditions to normal by dividing by this same number. 1.) Convert to Normal Conditions 5000 SCFH 1.0281 = 4863.34 NCFH 2.) Convert units From the chart, the conversion factor from m³/hr to CFH is 35.315. To get m3/hr from CFH, we will divide by this number. 4863.37 NCFH 35.315 = 137.7 Nm³/hr. 2.) Convert units From the chart, the conversion factor from m³/hr to CFH is 35.315. 3 3

ALL VENTS DEVICE FLOW RANGE - PRESSURE SERIES 5000 EPRV ALL VENTS DEVICE FLOW RANGE - PRESSURE 4 OZSI 16 OZSI E PR V - 2 4 4 OZSI 16 OZSI 32 OZSI E PR V - 2 0 32 OZSI SERIES 6000 PVRV - UBR VALVE 0.5 OZSI 16 OZSI P VRV - 6 U 0.5 OZSI 32 OZSI 16 OZSI P VRV - 4 U 32 OZSI 0.5 OZSI 16 OZSI P VRV - 3 U 32 OZSI 0.5 OZSI 16 OZSI P VRV - 2 U 32 OZSI SERIES 6000 PVRV - STD VALVE 0.5 OZSI 16 OZSI P VRV - 6 S 0.5 OZSI 16 OZSI P VRV - 4 S 0.5 OZSI 16 OZSI P VRV - 3 S 0.5 OZSI 16 OZSI P VRV - 2 S VENTING GAUGE HATCHES 4 OZSI 16 OZSI T VT H 2 OZSI 16 OZSI 32 OZSI M A R S H HAWK 32 OZSI FLOW RATES ARE AT 100% OVERPRESSURE FOR INDICATED SET PRESSURES. LIGHTER SHADED REGION INDICATES EXTENDED SERVICE RANGE (SET PRESSURE > 16OZSI) IF AVAILABLE. 1 2 3 4 5 6 7 8 9 10 50 100 500 1000 5000 10000 4 4

ALL VENTS DEVICE FLOW RANGE - VACUUM SERIES 6000 PVRV - UBR VALVE ALL VENTS DEVICE FLOW RANGE - VACUUM 0.5 OZSI 8 OZSI P VRV - 6 U 0.5 OZSI 8 OZSI P VRV - 4 U 0.5 OZSI 8 OZSI P VRV - 3 U SERIES 6000 PVRV - STD VALVE 0.5 OZSI 8 OZSI P VRV - 2 U 0.5 OZSI 8 OZSI P VRV - 6 S 0.5 OZSI 8 OZSI P VRV - 4 S 0.5 OZSI 8 OZSI P VRV - 3 S 0.5 OZSI 8 OZSI P VRV - 2 S FLOW RATES ARE AT 100% OVERPRESSURE FOR INDICATED SET PRESSURES. LIGHTER SHADED REGION INDICATES EXTENDED SERVICE RANGE (SET PRESSURE > 16OZSI) IF AVAILABLE. 1 2 3 4 6 7 8 9 10 50 100 5 5

VENTING GAUGE HATCHES SIZE ESTIMATION CHART - PRESSURE 100% 95% 90% 85% M A R S H H A W K 8 2 O Z S I M A R S H H A W K 8 1 6 O Z S I T V T H 8 4 O Z S I VENTING GAUGE HATCHES SIZE ESTIMATION CHART - PRESSURE T V T H 8 1 6 O Z S I 80% 75% 70% 65% 60% 55% 50% 45% 40% 35% 30% 25% 20% 1.) LOCATE FLOW RATE ON HORIZONTAL (X) AXIS. 15% 10% 5% 0% 2.) TRACE LINE UPWARDS TO DESIRED TANK PRESSURE FROM VERTICAL (Y) AXIS [NOTE: PRESSURE IS IN TERMS OF % OVER SET PRESSURE, WHERE 100% = 2 SET PRESSURE] 3.) SELECT DEVICE SIZE WHOSE FLOW PROFILE CONTAINS THE INTERSECTION OF THESE TWO LINES. 4.) IF THE INTERSECTION POINT LIES WITHIN MULTIPLE DEVICE PROFILES, SELECT THE LEFT-MOST DEVICE FOR SMALLER SIZE. 5.) ONCE DEVICE SIZE IS SELECTED, CONSULT THE FLOW CURVE TO THAT SPECIFIC DEVICE, CONFIGURATION SIZE, VALVE TYPE AND CONFIRM SUITABILITY OF FLOW CAPACITY. 5 10 15 20 25 30 35 40 45 50 55 60 65 70 6 6

VENTING GAUGE HATCHES VENTING GAUGE HATCHES SIZE ESTIMATION CHART - VACUUM SIZE ESTIMATION CHART - VACUUM 0% 1.) LOCATE FLOW RATE ON HORIZONTAL (X) AXIS. 5% 10% 2.) TRACE LINE UPWARDS TO DESIRED TANK PRESSURE FROM VERTICAL (Y) AXIS [NOTE: PRESSURE IS IN TERMS OF % OVER SET PRESSURE, WHERE 100% = 2 SET PRESSURE] 3.) SELECT DEVICE SIZE WHOSE FLOW PROFILE CONTAINS THE INTERSECTION OF THESE TWO LINES. 4.) IF THE INTERSECTION POINT LIES WITHIN MULTIPLE DEVICE PROFILES, SELECT THE LEFT-MOST DEVICE FOR SMALLER SIZE. 15% 5.) ONCE DEVICE SIZE IS SELECTED, CONSULT THE FLOW CURVE TO THAT SPECIFIC DEVICE, CONFIGURATION SIZE, VALVE TYPE AND CONFIRM SUITABILITY OF FLOW CAPACITY. 20% 25% 30% 35% 40% 45% 50% 55% 60% 65% 70% 75% 80% M A R S H H A W K 8 0. 4 O Z S I 85% 90% T V T H 8 0. 4 O Z S I 95% 100% 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5 5.5 6 6.5 7 7.5 8 8.5 9 9.5 10 7 7

SERIES 5000 EPRV SIZE ESTIMATION CHART - PRESSURE SERIES 5000 EPRV SIZE ESTIMATION CHART - PRESSURE 100% 95% 90% E P R V 2 0 4 O Z S I E P R V 2 4 4 O Z S I E P R V 2 0 1 6 O Z S I E P R V 2 4 1 6 O Z S I 85% 80% 75% 70% 65% 60% 55% 50% 45% 40% 35% 30% 25% 20% 1.) LOCATE FLOW RATE ON HORIZONTAL (X) AXIS. 15% 10% 5% 0% 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100 2200 2300 2400 2500 2600 2700 2.) TRACE LINE UPWARDS TO DESIRED TANK PRESSURE FROM VERTICAL (Y) AXIS [NOTE: PRESSURE IS IN TERMS OF % OVER SET PRESSURE, WHERE 100% = 2 SET PRESSURE] 3.) SELECT DEVICE SIZE WHOSE FLOW PROFILE CONTAINS THE INTERSECTION OF THESE TWO LINES. 4.) IF THE INTERSECTION POINT LIES WITHIN MULTIPLE DEVICE PROFILES, SELECT THE LEFT-MOST DEVICE FOR SMALLER SIZE. 5.) ONCE DEVICE SIZE IS SELECTED, CONSULT THE FLOW CURVE TO THAT SPECIFIC DEVICE, CONFIGURATION SIZE, VALVE TYPE AND CONFIRM SUITABILITY OF FLOW CAPACITY. 8 8

SERIES 6000 PVRV SIZE ESTIMATION CHART - PRESSURE STD 100% 95% 90% 85% 80% P V R V 2 ½ O Z S I P V R V 3 ½ O Z S I P V R V 2 1 6 O Z S I P V R V 4 ½ O Z S I P V R V 6 ½ O Z S I P V R V 3 1 6 O Z S I SERIES 6000 PVRV SIZE ESTIMATION CHART - PRESSURE STD P V R V 4 1 6 O Z S I P V R V 6 1 6 O Z S I 75% 70% 65% 60% 55% 50% 45% 40% 35% 30% 25% 20% 1.) LOCATE FLOW RATE ON HORIZONTAL (X) AXIS. 15% 10% 5% 0% 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 2.) TRACE LINE UPWARDS TO DESIRED TANK PRESSURE FROM VERTICAL (Y) AXIS [NOTE: PRESSURE IS IN TERMS OF % OVER SET PRESSURE, WHERE 100% = 2 SET PRESSURE] 3.) SELECT DEVICE SIZE WHOSE FLOW PROFILE CONTAINS THE INTERSECTION OF THESE TWO LINES. 4.) IF THE INTERSECTION POINT LIES WITHIN MULTIPLE DEVICE PROFILES, SELECT THE LEFT-MOST DEVICE FOR SMALLER SIZE. 5.) ONCE DEVICE SIZE IS SELECTED, CONSULT THE FLOW CURVE TO THAT SPECIFIC DEVICE, CONFIGURATION SIZE, VALVE TYPE AND CONFIRM SUITABILITY OF FLOW CAPACITY. 9 9

SERIES 6000 PVRV SIZE ESTIMATION CHART - VACUUM STD 0% SERIES 6000 PVRV SIZE ESTIMATION CHART - VACUUM STD 1.) LOCATE FLOW RATE ON HORIZONTAL (X) AXIS. 5% 10% 2.) TRACE LINE UPWARDS TO DESIRED TANK PRESSURE FROM VERTICAL (Y) AXIS [NOTE: PRESSURE IS IN TERMS OF % OVER SET PRESSURE, WHERE 100% = 2 SET PRESSURE] 3.) SELECT DEVICE SIZE WHOSE FLOW PROFILE CONTAINS THE INTERSECTION OF THESE TWO LINES. 4.) IF THE INTERSECTION POINT LIES WITHIN MULTIPLE DEVICE PROFILES, SELECT THE LEFT-MOST DEVICE FOR SMALLER SIZE. 15% 5.) ONCE DEVICE SIZE IS SELECTED, CONSULT THE FLOW CURVE TO THAT SPECIFIC DEVICE, CONFIGURATION SIZE, VALVE TYPE AND CONFIRM SUITABILITY OF FLOW CAPACITY. 20% 25% 30% 35% 40% 45% 50% 55% 60% 65% 70% 75% 80% 85% P V R V 2 ½ O Z S I P V R V 3 ½ O Z S I P V R V 4 ½ O Z S I P V R V 6 ½ O Z S I 90% 95% P V R V 2 8 O Z S I P V R V 3 1 6 O Z S I P V R V 4 8 O Z S I P V R V 6 8 O Z S I 100% 10 20 30 40 50 60 70 80 90 10 10

P V R V 2 ½ O Z S I SERIES 6000 PVRV SIZE ESTIMATION CHART - PRESSURE UBR 100% 95% 90% 85% 80% P V R V 3 ½ O Z S I P V R V 2 1 6 O Z S I P V R V 4 ½ O Z S I P V R V 6 ½ O Z S I P V R V 3 1 6 O Z S I SERIES 6000 PVRV SIZE ESTIMATION CHART - PRESSURE UBR P V R V 4 1 6 O Z S I P V R V 6 1 6 O Z S I 75% 70% 65% 60% 55% 50% 45% 40% 35% 30% 25% 20% 15% 10% 5% 0% 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 1.) LOCATE FLOW RATE ON HORIZONTAL (X) AXIS. 2.) TRACE LINE UPWARDS TO DESIRED TANK PRESSURE FROM VERTICAL (Y) AXIS [NOTE: PRESSURE IS IN TERMS OF % OVER SET PRESSURE, WHERE 100% = 2 SET PRESSURE] 3.) SELECT DEVICE SIZE WHOSE FLOW PROFILE CONTAINS THE INTERSECTION OF THESE TWO LINES. 4.) IF THE INTERSECTION POINT LIES WITHIN MULTIPLE DEVICE PROFILES, SELECT THE LEFT-MOST DEVICE FOR SMALLER SIZE. 5.) ONCE DEVICE SIZE IS SELECTED, CONSULT THE FLOW CURVE TO THAT SPECIFIC DEVICE, CONFIGURATION SIZE, VALVE TYPE AND CONFIRM SUITABILITY OF FLOW CAPACITY. 11 11

SERIES 6000 PVRV SIZE ESTIMATION CHART - VACUUM UBR 0% SERIES 6000 PVRV SIZE ESTIMATION CHART - VACUUM UBR 1.) LOCATE FLOW RATE ON HORIZONTAL (X) AXIS. 5% 10% 15% 20% 25% 2.) TRACE LINE UPWARDS TO DESIRED TANK PRESSURE FROM VERTICAL (Y) AXIS [NOTE: PRESSURE IS IN TERMS OF % OVER SET PRESSURE, WHERE 100% = 2 SET PRESSURE] 3.) SELECT DEVICE SIZE WHOSE FLOW PROFILE CONTAINS THE INTERSECTION OF THESE TWO LINES. 4.) IF THE INTERSECTION POINT LIES WITHIN MULTIPLE DEVICE PROFILES, SELECT THE LEFT-MOST DEVICE FOR SMALLER SIZE. 5.) ONCE DEVICE SIZE IS SELECTED, CONSULT THE FLOW CURVE TO THAT SPECIFIC DEVICE, CONFIGURATION SIZE, VALVE TYPE AND CONFIRM SUITABILITY OF FLOW CAPACITY. 30% 35% 40% 45% 50% 55% 60% 65% 70% 75% 80% 85% P V R V 2 ½ O Z S I P V R V 3 ½ O Z S I P V R V 4 ½ O Z S I P V R V 6 ½ O Z S I 90% 95% P V R V 2 8 O Z S I P V R V 3 1 6 O Z S I P V R V 4 8 O Z S I P V R V 6 8 O Z S I 100% 10 20 30 40 50 60 70 80 90 100 12 12

FLOW CURVE INDEX FLOW CURVE INDEX Introduction to Hawkeye Flow Curve Reference Book... 2 Series 200 & 300 TVTH... Pressure + Vacuum Curve... Pressure + Vacuum Relief Atmosphere STD...[P-28VGH]... 14 Series 4000 Marsh Hawk... Pressure + Vacuum Curve... Pressure + Vacuum Relief Atmosphere STD...[P-48VGH]... 15 Series 5000 EPRV - 20... Pressure Curve... Pressure Relief Only Atmosphere STD...[P-50XX/52XX]... 16 Series 5000 EPRV - 24... Pressure Curve... Pressure Relief Only Atmosphere STD...[P-51XX/53XX]... 17 Series 6000 PVRV - 2... Pressure Curve... Pressure + Vacuum Relief Atmosphere UBR...[P-6200/02]... 18 Series 6000 PVRV - 2... Pressure Curve... Pressure + Vacuum Relief Atmosphere STD...[P-6203/01]... 19 Series 6000 PVRV - 2... Pressure Curve... Pressure + Vacuum Relief Pipe-Away UBR...[P-6210/12]...20 Series 6000 PVRV - 2... Pressure Curve... Pressure + Vacuum Relief Pipe-Away STD...[P-6213/11]... 21 Series 6000 PVRV - 2... Pressure Curve... Pressure Relief Only Atmosphere STD...[P-6224]...22 Series 6000 PVRV - 2... Pressure Curve... Pressure Relief Only Atmosphere UBR...[P-6225]...23 Series 6000 PVRV - 2... Pressure Curve... Pressure Relief Only Pipe-Away STD...[P-6234]...24 Series 6000 PVRV - 2... Pressure Curve... Pressure Relief Only Pipe-Away UBR...[P-6235]...25 Series 6000 PVRV - 3... Pressure Curve... Pressure + Vacuum Relief Atmosphere UBR...[P-6300/02]...26 Series 6000 PVRV - 3... Pressure Curve... Pressure + Vacuum Relief Atmosphere STD...[P-6303/01]...27 Series 6000 PVRV - 3... Pressure Curve... Pressure + Vacuum Relief Pipe-Away UBR...[P-6310/12]...28 Series 6000 PVRV - 3... Pressure Curve... Pressure + Vacuum Relief Pipe-Away STD...[P-6313/11]...29 Series 6000 PVRV - 3... Pressure Curve... Pressure Relief Only Atmosphere STD...[P-6324]...30 Series 6000 PVRV - 3... Pressure Curve... Pressure Relief Only Atmosphere UBR...[P-6325]... 31 Series 6000 PVRV - 3... Pressure Curve... Pressure Relief Only Pipe-Away STD...[P-6334]...32 Series 6000 PVRV - 3... Pressure Curve... Pressure Relief Only Pipe-Away UBR...[P-6335]...33 Series 6000 PVRV - 4... Pressure Curve... Pressure + Vacuum Relief Atmosphere UBR...[P-6400/02]...34 Series 6000 PVRV - 4... Pressure Curve... Pressure + Vacuum Relief Atmosphere STD...[P-6403/01]...35 Series 6000 PVRV - 4... Pressure Curve... Pressure + Vacuum Relief Pipe-Away UBR...[P-6410/12]...36 Series 6000 PVRV - 4... Pressure Curve... Pressure + Vacuum Relief Pipe-Away STD...[P-6413/11]...37 Series 6000 PVRV - 4... Pressure Curve... Pressure Relief Only Atmosphere STD...[P-6424]...38 Series 6000 PVRV - 4... Pressure Curve... Pressure Relief Only Atmosphere UBR...[P-6425]...39 Series 6000 PVRV - 4... Pressure Curve... Pressure Relief Only Pipe-Away STD...[P-6434]...40 Series 6000 PVRV - 4... Pressure Curve... Pressure Relief Only Pipe-Away UBR...[P-6435]... 41 Series 6000 PVRV - 6... Pressure Curve... Pressure + Vacuum Relief Atmosphere UBR...[P-6600/02]...42 Series 6000 PVRV - 6... Pressure Curve... Pressure + Vacuum Relief Atmosphere STD...[P-6603/01]...43 Series 6000 PVRV - 6... Pressure Curve... Pressure + Vacuum Relief Pipe-Away UBR...[P-6610/12]...44 Series 6000 PVRV - 6... Pressure Curve... Pressure + Vacuum Relief Pipe-Away STD...[P-6613/11]...45 Series 6000 PVRV - 6... Pressure Curve... Pressure Relief Only Atmosphere STD...[P-6624]...46 Series 6000 PVRV - 6... Pressure Curve... Pressure Relief Only Atmosphere UBR...[P-6625]...47 Series 6000 PVRV - 6... Pressure Curve... Pressure Relief Only Pipe-Away STD...[P-6634]...48 Series 6000 PVRV - 6... Pressure Curve... Pressure Relief Only Pipe-Away UBR...[P-6635]...49 Series 6000 PVRV - 8 API... Pressure Curve... Pressure + Vacuum Relief Atmosphere UBR...[P-6800/02]...50 Series 6000 PVRV - 8 API... Pressure Curve... Pressure + Vacuum Relief Atmosphere STD...[P-6803/01]... 51 Series 6000 PVRV - 8 API... Pressure Curve... Pressure + Vacuum Relief Pipe-Away UBR...[P-6810/12]...52 Series 6000 PVRV - 8 API... Pressure Curve... Pressure + Vacuum Relief Pipe-Away STD...[P-6813/11]...53 Series 6000 PVRV - 8 API... Pressure Curve... Pressure Relief Only Atmosphere STD...[P-6824]...54 Series 6000 PVRV - 8 API... Pressure Curve... Pressure Relief Only Atmosphere UBR...[P-6825]...55 Series 6000 PVRV - 8 API... Pressure Curve... Pressure Relief Only Pipe-Away STD...[P-6834]...56 Series 6000 PVRV - 8 API... Pressure Curve... Pressure Relief Only Pipe-Away UBR...[P-6835]...57 Series 6000 PVRV - 2... Vacuum Curve... Pressure + Vacuum Relief Atmosphere UBR...[V-6200/03/10/13]...58 Series 6000 PVRV - 2... Vacuum Curve... Pressure + Vacuum Relief Atmosphere STD...[V-6203/01/12/11]...59 Series 6000 PVRV - 2... Vacuum Curve... Vacuum Relief Only Atmosphere STD...[V-6246]...60 Series 6000 PVRV - 2... Vacuum Curve... Vacuum Relief Only Atmosphere UBR...[V-6247]... 61 Series 6000 PVRV - 3... Vacuum Curve... Pressure + Vacuum Relief Atmosphere UBR...[V-6300/03/10/13]...62 Series 6000 PVRV - 3... Vacuum Curve... Pressure + Vacuum Relief Atmosphere STD...[V-6303/01/12/11]...63 Series 6000 PVRV - 3... Vacuum Curve... Vacuum Relief Only Atmosphere STD...[V-6346]...64 Series 6000 PVRV - 3... Vacuum Curve... Vacuum Relief Only Atmosphere UBR...[V-6347]...65 Series 6000 PVRV - 4... Vacuum Curve... Pressure + Vacuum Relief Atmosphere UBR...[V-6400/03/10/13]...66 Series 6000 PVRV - 4... Vacuum Curve... Pressure + Vacuum Relief Atmosphere STD...[V-6403/01/12/11]...67 Series 6000 PVRV - 4... Vacuum Curve... Vacuum Relief Only Atmosphere STD...[V-6446]...68 Series 6000 PVRV - 4... Vacuum Curve... Vacuum Relief Only Atmosphere UBR...[V-6447]...69 Series 6000 PVRV - 6... Vacuum Curve... Pressure + Vacuum Relief Atmosphere UBR...[V-6600/03/10/13]...70 Series 6000 PVRV - 6... Vacuum Curve... Pressure + Vacuum Relief Atmosphere STD...[V-6603/01/12/11]... 71 Series 6000 PVRV - 6... Vacuum Curve... Vacuum Relief Only Atmosphere STD...[V-6646]...72 Series 6000 PVRV - 6... Vacuum Curve... Vacuum Relief Only Atmosphere UBR...[V-6647]... 73 Series 6000 PVRV - 8 API... Vacuum Curve... Pressure + Vacuum Relief Atmosphere UBR...[V-6800/03/10/13]... 74 Series 6000 PVRV - 8 API... Vacuum Curve... Pressure + Vacuum Relief Atmosphere STD...[V-6803/01/12/11]... 75 Series 6000 PVRV - 8 API... Vacuum Curve... Vacuum Relief Only Atmosphere STD...[V-6846]... 76 Series 6000 PVRV - 8 API... Vacuum Curve... Vacuum Relief Only Atmosphere UBR...[V-6847]...77 CONTACT YOUR HAWKEYE SALES REPRESENTATIVE TO GET THE FLOW CURVE FOR YOUR SPECIFIC DEVICE. 13 13

Contents 2006-2018 Hawkeye Industries Inc. This document is uncontrolled, and is subject to change without notice. Please refer to www.hawk-eye.com for the most up-to-date product information. Printed in Canada. 2110 70 Ave NW Edmonton, AB, Canada T6P 1N6 Toll Free: (800) 910-4295 Phone: (780) 490-4295 Fax: (780) 490-4290 www.hawk-eye.com Flow Curve Back Cover Mar 2018