Doc. no.dit om005 PRODUCT NAME. IO-Link/ELECTRO-PNEUMATIC REGULATOR. MODEL / Series / Product Number ITV*0*0-IO****-X395

Similar documents
1.0. ISE70/71 Series CAT.ES A. MPa/1.6 MPa. 3-Screen Display High-Precision Digital Pressure Switch. Angled display.

REASONS FOR THE DEVELOPMENT

Digital electro-pneumatic regulators Series ER100

Application Notes. SLP85xD Load Cells

Datasheet: K-30 ASCII Sensor

2/ Port G1/4

Stand-Alone Bubble Detection System

Specifications and information are subject to change without notice. Up-to-date address information is available on our website.

TH-1800-T TRX-700-CNG Converter

Sensoric 4-20 ma Transmitter Board Operation Manual

APPLICATION NOTE. OJ-DV Modbus protocol. OJ Drives A DRIVES PROGRAMME DEDICATED TO VENTILATION SOLUTIONS E 03/18 (PDJ) 2018 OJ Electronics A/S

User manual CF8-D/W-IN

Exercise 8. Closed-Loop Pressure Control, Proportional-Plus-Integral Mode EXERCISE OBJECTIVE

Datasheet May, 2017 HPSD 4000 Pressure Transducer 1/5. Applications

BAROMETER PRESSURE STANDARD PRESSURE CONTROLLER

Instruction and Maintenance Manual

Instruction and Maintenance Manual

A4 Operation Manual. Fig.1-1 Controller Socket Diagram

Vacuum Saving Valve Series ZP2V How to Order ZP2V A5 03 Connection thread symbol for the pad Male thread connection Symbol Thread Applicable fixed ori

Troubleshooting Guide: 640 Pediatric Exam Table with Midmark Scale

A4s Operation Manual

Model 130M Pneumatic Controller

User Manual. asense VAV. CO 2 / temperature sensor with built-in general purpose controller

PRODUCT MANUAL. Diver-MOD

CF8-W-Disp-CO. User manual. CO 2 / CO sensor with built-in general purpose controller

Manual Weighingblock VB2 series and Uniscale

5.0 MPa Maximum Supply Pressure. New. Stepless control of air pressure proportional to an electrical signal. Series ITVX CAT.

YSC-8330 USER MANUAL XI AN TYPICAL INDUSTRIES CO.,LTD.

USER MANUAL. Intelligent Diagnostic Controller IDC24-A IDC24-AF IDC24-AFL IDC24-F IDP24-A * IDP24-AF * IDP24-AFL * IDP24-F * 1/73

No.IL02-OM00011-A PRODUCT NAME LOCK UP VALVE. MODEL/ Series IL201 IL211

TR Electronic Pressure Regulator. User s Manual

Ultima. X Series Gas Monitor

Installation and Operation Manual

I/P Transducer Positioner Module

Appendix D: SOP of INNOVA 1412 Photoacoustic Multi-Gas Monitor. Description and Principle of Operation

Overview. Front Panel: Keypad and Display

VOLUME BOOSTER RELAYS YT-300 / 305 SERIES

86BSD Backside Digital Output

Instruction Manual. PLT Series. 1. General Specification. 2. Installation. 3. Wiring. 4. Function. 5. Setting & Calibration

COSMO INSTRUMENTS CO., LTD.

Race Screen: Figure 2: Race Screen. Figure 3: Race Screen with Top Bulb Lock

RG2 Gripper Datasheet Version 1.6

Plant Air Energy Saving

BUBBLER CONTROL SYSTEM

HART Communications Board

CONSOLE-320 ENGLISH. 230A: CONSOLE-320 with cable data output Item 230B: CONSOLE-320 with cable + wireless radio data output

User Manual. asense miii. / CO sensor with built-in general purpose controller

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)

MANUAL KPS Pressure Control Valve

MODEL 100 NITROGEN INFLATION CART

TECHNICAL MANUAL CALIBRATION PROCEDURE FOR PRESSURE GAUGE. This publication replaces T.O. 33K dated 30 January 2012.

Atlas 6TM. Indoor Air Quality Monitor Instruction Manual. Measures CO 2, Temperature and Humidity DISTRIBUTED BY

PRELIMINARY DATASHEET

Exercise 2-2. Second-Order Interacting Processes EXERCISE OBJECTIVE DISCUSSION OUTLINE. The actual setup DISCUSSION

Design Envelope Booster. Sequence of operation

Dimensions [All numbers in brackets are in millimeters.] K4-2 US (supplied) 1/2" Centered (Default)

Industrial Filter. FGD series

10 switches simultaneously. The settings of the master sensor (source of copy) can be copied to the slave sensors. Reducing setting labor

DPC-30 DPC-100. Reference Manual

AMS 6915 Board mount pressure sensor with digital output (I²C)

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

Technical Bulletin, Communicating with Gas Chromatographs

UBEC 1AT. AUTO TANK Fill System Installation, Operation, & Setup Instructions

Roller AC Servo System

Autopilot setup. VRF (Virtual Rudder Feedback) calibration. Software setup NSS evo2 Installation Manual

Safety Manual VEGAVIB series 60

NIBP OEM Module. (Model : M_NIBP) Contents. 1. Concept 2. Composition 3. PCB Dimension 4. Specification 5. Protocol 6. Cuff & Electrical Connection

CDS-2000 CO 2 Sensor Verification, Calibration, and Troubleshooting Bulletin

Application Block Library Fan Control Optimization

BS12N Piezoresistive OEM Pressure Sensor

Fail Operational Controls for an Independent Metering Valve

Pegas 4000 MF Gas Mixer InstructionManual Columbus Instruments

Electro-Pneumatic Converter YT-940 SERIES

Product Overview. Product Description CHAPTER

COMPRESSOR PACK SUCTION CONTROLLER TYPE: LP41x

For a similar sensor with o-ring mounting, refer to the 85BSD digital output pressure sensor.

MODEL 6600 Rev. B4 USER'S MANUAL LAVERSAB INC., 505 GILLINGHAM LANE. SUGAR LAND TX (281) FAX: (281)

JOLLY2. Installation user s manual. 6 different operating modes selectable. version 3.3. DATA TO BE FILLED OUT BY THE INSTALLER (Page 1)

Certification Exhibit FCC ID: R7PIWRS4. FCC Rule Part: ACS Report Number: W03.11.A

SDI mA Pressure Transducer (Submersible + Dry) Model WL2100 Operating Manual

Model 601CV. Mass Flow Controller. Product Features:

AN-140. Protege WX SALLIS Integration Application Note

HTD series digital differential pressure sensors

PTG100 Precision Test Gauge

SHIMADZU LC-10/20 PUMP

SPD Pressure Sensor Families

OC508 Programmable mv Calibrator

Model GFC 7000T CO 2 Analyzer (Addendum to GFC 7000TA Manual, PN 07272)

BI-680 Online Dissolved Oxygen Controller Instruction Manual

ATM/GR. Electronic pressure switches CUSTOMER BENEFITS

SUPER PRECISION AIR RELAYS

Precision Regulator IR3120

ASDX Series Silicon Pressure Sensors

Fixed Ozone Monitor User Manual December, Automatikprodukter

e2c 20 - easy to connect

Smart performance with innovative and ever-strong coil drive even under harsh working environments

BS12 Piezoresistive OEM Pressure Sensor

RAM Operation Manual

Technical Data Sheet MF010-O-LC

CONTROL LOGIC DESCRIPTION DOCUMENT IC-410ND

Transcription:

Doc. no.dit-69900-om005 PRODUCT NAME IO-Link/ELECTRO-PNEUMATIC REGULATOR MODEL / Series / Product Number ITV*0*0-IO****-X395

This is the operation manual for the IO-Link compliant ITV. For other contents which are not described in this manual, please refer to the operation manual for the standard product. 1. Product Specifications Item Max. supply power Min. supply power Power supply voltage Current consumption Set pressure range Communication specifications Output signal Vendor ID Device ID 12 bars N/A Specified value Set pressure + 1 bar (0.1 MPa) 24 VDC ±10% F.S. 0.12 ADC or less 0.05 to 10 bar IO-Link communication Detects when reaching the set pressure. ±10% F.S. 131(Dec) 272(Dec) Safety Instructions, precautions and other specifications are the same as the standard series.. 2. Wiring Power supply and communication connector No connections Power LED Communication LED 1

3.Communication specifications Item Specification Note Protocol IO-Link version Version 1.1 Communication speed 230.4 kbps (COM3) IO-Link port Class A IO-Link type Device Process data 2 bytes IN 2 bytes OUT Resolution 12 BIT 4.Pressure setting method and output monitoring Pressure can be set by sending input data from the master PLC to the regulator where the F.S is based on a 12 BIT resolution. Do not operate the product outside of the specifications. <Relationship between set data and pressure> Set data 0x0000 0x7FF8 Output pressure 0 bars 10 bars From the 16 BIT process data (2byte), input the 12BIT resolution starting from 3rd BIT to the 14th BIT. Refer to the communication data for further details. 2

5. Communication data 5.1 Process data map PD OUT (to ITV) 15* 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Bit Set pressure value.(13 BIT) Disabled Value 100% F.S.is indicated using 12 BITs, from the 3rd BIT to the 14th BIT. *Setting up to 120% F.S is possible by using the 15th BIT (However this is out of warranty). PD IN (from ITV) 15* 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Bit Output pressure (13BIT) On hold BDC1 Value 100% F.S. is indicated using 12 BITs, from the 3rd BIT to the 14th BIT. *Setting up to 120% F.S is possible by using the 15th BIT (However this is out of warranty). Detection of the set pressure BDC1 1 When set pressure is reached 0 When set pressure is not reached 5.2 List of parameters INDEX Name: Function 0x42 Gain tuning function Sets the response time. 0x43 Sensitivity tuning function Sets the sensitivity. 0x41 HOLD/CLEAR setting Sets the operation in response to a communication error. 0x44 Initialization Resets the settings to the default value. 0x46 Zero adjustment Sets the minimum pressure. 0x47 Span adjustment Sets the maximum pressure. 3

Parameter index Parameter name Function 0x42 Bit Bit 3, 2, 1, 0 Gain tuning function The response time can be changed by tuning the gain. When the gain is increased, the response time tends to be faster, but stability will be lost, which may cause hunting (unstable pressure). Default: 9 Value Bit 3 2 1 0 Setting 0 0 0 0 Gain 0 0 0 0 1 Gain 1 0 0 1 0 Gain 2 0 0 1 1 Gain 3 0 1 0 0 Gain 4 0 1 0 1 Gain 5 0 1 1 0 Gain 6 0 1 1 1 Gain 7 1 0 0 0 Gain 8 1 0 0 1 Gain 9 1 0 1 0 Gain A 1 0 1 1 Gain B 1 1 0 0 Gain C 1 1 0 1 Gain D 1 1 1 0 Gain E 1 1 1 1 Gain F 4

Parameter index Parameter name Function 0x43 Sensitivity tuning function Changing the sensitivity will change the pressure correction operation near the set pressure point. When the sensitivity is increased, hunting may occur. When the sensitivity is decreased, hunting will be reduced, but the pressure correction will be reduced, so there may be a moderate pressure instability. Default value :0 Bit Bit 2, 1, 0 Value Bit 2 1 0 Setting 0 0 0 Sensitivity - 0 0 1 Sensitivity 0 1 0 Sensitivity 0 0 1 1 Sensitivity 1 1 0 0 Sensitivity 2 1 0 1 Sensitivity 3 1 1 0 Sensitivity 4 1 1 1 Sensitivity 5 Parameter index Parameter name Function 0x41 Hold/Clear setting Sets the output setting when communication error occurs. 0: Exhaust completely (Clear). 1: Output pressure is maintained (Hold). Default value: 0 Bit Bit 0 Value Bit 0 Setting 0 Clear 1 Hold 5

Parameter name 0x44 Parameter name Initialization Function All of the setup including the internal control constant is initialized with this function. Perform this function only when the product is completely stopped due to error. Bit BIT 0 to 7 Value Any value between 0 to 11111111 Parameter index Parameter name Function 0x46(Zero adjusting), 0x47(Span adjusting) Zero adjusting, Span adjusting Zero adjusting (hereinafter referred to as F_1) corresponds to set the minimum pressure, Span adjusting (hereinafter referred to as F_2) to set the maximum pressure. F_1 and F_2 have setting ranges of 0-90%F.S. and 10-120%F.S., respectively. However, the set pressure exceed rated output; 100%F.S. is out of warranty. (refer to Fig.2,3) The values are necessary to satisfy F_1 + 10%F.S. < F2. If not, the previous values are reflected in this function. Default of Zero adjusting: 0x0000 Default of Span adjusting: 0x0FFF Bit BIT 12 Value Relationship between F1/F2 and the set pressure Zero adjusting F_1 Span adjusting F_2 Minimum Maximum Minimum Maximum Input value 0x0000 0x0E66 0x019A 0x1332 Set pressure 0%F.S. 0 Bar 90%F.S. 9 Bar 10%F.S. 1 Bar 120%F.S. 12 Bar 6

Set Pressure Set Pressure 12 Bar Out of warranty 10 Bar 8 Bar Range of F_1 Range of F_2 6 Bar 0~90% (0x0000~0x0E66) Variable range 10~120% (0x019A~0x1332) 4 Bar 2 Bar 0 Bar Process date(input) Fig.2 Range of F_1 and F_2 F_1=0x0666(40%) F_2=0x0999(60%) 50% 50% Process date(input) The set pressure output 50% when the process date input 50% 7

Set Pressure F_1=0x0666(40%) F_1=0x0800(50%) 45% 50% Process date(input) The set pressure output 45% when the process date input 50% Fig.3 Configuration examples 5.3 Error Message LED Item ON OFF Flashing Power Power is supplied Power supply is not - (Green) Internal diagnosis error (Red) connected Communication Communication in stand-by mode Communication disconnected Communication exchange (Green) Error code Error No. Name: Description Internal diagnosis error ROM read / write error 0X5000 Control depends on the Hold/Clear setting. Power LED turned ON Red. If the error is not corrected even after disconnecting the power supply, perform "Initialization. Target value over range The data of the target value has exceeded the 0X6320 error specification (120% F.S. is exceeded). 0X8C20 Output pressure value over range error Input a target value within the specification. The data of the output pressure value has exceeded the specification (120% F.S. is exceeded). Adjust the output pressure to within the specification. End of report 8

Revision history A: Function addition of F_1 and F_2 B: Vender ID and device ID addition 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021 JAPAN Tel: + 81 3 5207 8249 Fax: +81 3 5298 5362 URL http://www.smcworld.com 0120-837-838 Note: Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. 2012 SMC Corporation All Rights Reserved. 9