A Complete Solution For HIPPS

Similar documents
PressureGuard. Self-Contained Hydraulic Emergency Shutdown Systems For Rotary or Non API 6A Linear Valves

EL-O-Matic E and P Series Pneumatic Actuator SIL Safety Manual

Product Data Sheet L-TRDD-D Rev. 1 November Shafer L-Series Linear Valve Actuators Thrust Ratings and Dimensional Data

Shafer RV-Series Rotary Vane Valve Actuators

Interactive Solutions Tool High-Integrity Pressure Protection Systems (HIPPS)

Neles trunnion mounted ball valve Series D Rev. 2. Safety Manual

Neles ValvGuard VG9000H Rev 2.0. Safety Manual

BETTIS RPE Series Rack and Pinion Pneumatic Actuators. Safety Guide DOC.SG.BRPE.EN Rev. 1 November 2015

Safety manual for Fisher GX Control Valve and Actuator

Every things under control High-Integrity Pressure Protection System (HIPPS)

Jamesbury Pneumatic Rack and Pinion Actuator

High performance disc valves Series Type BA, BK, BW, BM, BN, BO, BE, BH Rev Safety Manual

This manual provides necessary requirements for meeting the IEC or IEC functional safety standards.

Safety Guide DOC.SG.EF.EN Rev. 0 March EL-O-Matic F-Series Rack and Pinion Pneumatic Actuators

High Integrity Pressure Protection Systems HIPPS

TRI LOK SAFETY MANUAL TRI LOK TRIPLE OFFSET BUTTERFLY VALVE. The High Performance Company

RESILIENT SEATED BUTTERFLY VALVES FUNCTIONAL SAFETY MANUAL

DeZURIK. KSV Knife Gate Valve. Safety Manual

L&T Valves Limited SAFETY INTEGRITY LEVEL (SIL) VERIFICATION FOR HIGH INTEGRITY PRESSURE PROTECTION SYSTEM (HIPPS) Report No.

Solenoid Valves used in Safety Instrumented Systems

Increase Gas Production, Reduce Maintenance and Decrease Environmental Risks

DeZURIK. KGC Cast Knife Gate Valve. Safety Manual

PREDICTING HEALTH OF FINAL CONTROL ELEMENT OF SAFETY INSTRUMENTED SYSTEM BY DIGITAL VALVE CONTROLLER

SIL explained. Understanding the use of valve actuators in SIL rated safety instrumented systems ACTUATION

Fisher FIELDVUE DVC6200f Digital Valve Controller PST Calibration and Testing using ValveLink Software

Partial Stroke Testing. A.F.M. Prins

VBL Volume Booster. Features. D103393X012 January 2013

SIL Safety Manual for Fisherr ED, ES, ET, EZ, HP, or HPA Valves with 657 / 667 Actuator

DeZURIK Double Block & Bleed (DBB) Knife Gate Valve Safety Manual

Fisher Optimized Antisurge Control Valves High reliability to meet world-class production demands

VBL Volume Booster. Instruction Manual Part Number: D103317X012, Rev. 1 Release: August 2013

Valve Communication Solutions. Safety instrumented systems

Instrumented Safety Systems

Session One: A Practical Approach to Managing Safety Critical Equipment and Systems in Process Plants

Ultima. X Series Gas Monitor

Section 1: Multiple Choice

Fisher 2625 and 2625NS Volume Boosters

Autocalibration Systems for In Situ Oxygen Analyzers

FULL STAINLESS STEEL EXPLOSION-PROOF SOLUTIONS OIL & GAS I OFFSHORE AND ONSHORE

Specify the Right Remote Diaphragm Seal Solution for Vacuum Applications

Partial Stroke Testing for SRD991 and SRD960

Failure Modes, Effects and Diagnostic Analysis

MARKET OUTLOOK. Power Chemicals Petroleum Water/Wastewater Oil & Gas Pulp & Paper and more

Understanding safety life cycles

Eutectic Plug Valve. SIL Safety Manual. SIL SM.015 Rev 0. Compiled By : G. Elliott, Date: 19/10/2016. Innovative and Reliable Valve & Pump Solutions

Fisher DVI Desuperheater Venturi Inline

Delayed coking APPLICATION REPORT CLOSEOPEN

2600T Series Pressure Transmitters Plugged Impulse Line Detection Diagnostic. Pressure Measurement Engineered solutions for all applications

Rosemount 2120 Level Switch

The Key Variables Needed for PFDavg Calculation

EMERGENCY SHUT-DOWN RELIABILITY ADVANTAGE

Fisher DSA Steam-Atomized Desuperheater

Pneumatic QEV. SIL Safety Manual SIL SM Compiled By : G. Elliott, Date: 8/19/2015. Innovative and Reliable Valve & Pump Solutions

SIL Safety Manual. ULTRAMAT 6 Gas Analyzer for the Determination of IR-Absorbing Gases. Supplement to instruction manual ULTRAMAT 6 and OXYMAT 6

Implementing IEC Standards for Safety Instrumented Systems

Failure Modes, Effects and Diagnostic Analysis. Rosemount Inc. Chanhassen, MN USA

Hydraulic (Subsea) Shuttle Valves

Bespoke Hydraulic Manifold Assembly

Failure Modes, Effects and Diagnostic Analysis

Emerson Deepwater Offshore Solutions Proven Fisher technology to mitigate risks and meet production targets

FP15 Interface Valve. SIL Safety Manual. SIL SM.018 Rev 1. Compiled By : G. Elliott, Date: 30/10/2017. Innovative and Reliable Valve & Pump Solutions

Solenoid Valves For Gas Service FP02G & FP05G

Double whammy: the benefits of valve signatures and partial stroke testing

Failure Modes, Effects and Diagnostic Analysis

Rosemount 2130 Level Switch

Emerson Solutions for Ammonia Production Gain efficiency and enhance your operations

CASE STUDY. Compressed Air Control System. Industry. Application. Background. Challenge. Results. Automotive Assembly

Type 1367 High-Pressure Instrument Supply System with Overpressure Protection

Competence in Functional Safety

Control Valve Training Course Program

Fuel Gas Pressure Control Solutions for Fired Heaters and Boilers

YT-3300 / 3301 / 3302 / 3303 / 3350 / 3400 /

Failure Modes, Effects and Diagnostic Analysis

Special Documentation Proline Promass 80, 83

Beyond Switches for Pump Monitoring:

Life Cycle Benefits: Maintenace (Control Valve Diagnostic and Field Device Diagnostic Management)

Knowledge, Certification, Networking

SPR - Pneumatic Spool Valve

Section 1: Multiple Choice Explained EXAMPLE

61 Series Pilots for Pilot-Operated Pressure Reducing Regulators

Safety Manual. Process pressure transmitter IPT-1* 4 20 ma/hart. Process pressure transmitter IPT-1*

Autocalibration Systems For In Situ Oxygen Analyzers

CoriolisMaster mass flowmeter Diagnostics, verification and proof test

SPECIAL PRINT. Innovative Control Technology. Safety in the Process Industry. SAMSON AG Manuel Hinkelmann Marcel Richter Monika Schneider

Valve Communication Solutions Axiom

Fisher L2sj Low Emission Liquid Level Controller

Proof Testing A key performance indicator for designers and end users of Safety Instrumented Systems

Analysis of Instrumentation Failure Data

The benefits of the extended diagnostics feature. Compact, well-proven, and flexible

Type 310A-32A Pressure Reducing Regulator and Type 310A-32A-32A Working Monitor Regulator

PositionMaster EDP300 Extended Diagnostics. Compact, well-proven, and flexible

Fisher 4660 High-Low Pressure Pilot

1805 Series Relief Valves

The Criticality of Cooling

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012

Cold-acclimatised pipelines

THE NATURAL CHOICE. High end valves for the natural gas value chain. Inspired By Challenge

Understanding the How, Why, and What of a Safety Integrity Level (SIL)

Failure Modes, Effects and Diagnostic Analysis. Rosemount Inc. Chanhassen, Minnesota USA

A Planning Guide for Effective Use HART Implementations. December 2012 (D103278X012)

Transcription:

A Complete Solution For HIPPS

Are You Also Facing These Challenges For Your HIPPS? PERFORMANCE Test and Working procedures / Safety Life Cycle ENVIRONMENT Fugitive Emissions / Reduce or Eliminate Flares DESIGN IEC 61508 / 511 / Verification of SIL? TECHNOLOGY Initiators / Logic Solver / Final elements ANALYZE Risk Study / HAZOP / Safety Intergity Level CONTRACT MANAGEMENT Multiple Suppliers / Schedule Certainty / Validation Due to the complexity of HIPPS, compared with conventional pressure relief systems, operators fear losing control during scheduled test. This often results in tests being incomplete or not carried out at all, impacting the required safety level of the system. A solution with proof test procedures and automated PST will ensure this is handled correctly. There are many different challenges analyzing, designing, building, and testing of a HIPPS. One of the main challenges is the lack of standards outlining design parameters, resulting in a high level of interaction between end users, engineering and contractors during the analysis and design phase. of the system to ensure it fully meets the requirements outlined in the Safety Requirements Specification (SRS) and that the SIL level is maintained throughout the safety lifetime of the installation. Looking at the equipment available on the market today, it is not difficult to source the different components needed for a HIPPS. The challenge is more in the validation and verification

The Emerson Solution Closes The Loop And Ensures The Safety Lifecycle ONE-STOP-SHOP FOR ALL CONTROL EQUIPMENT SIL VERIFICATION IEC 61508/511 HIPPS COMPLIANCE REPORT WORKING PROCEDURES, PROOF TEST, INSPECTION PLANS What if you were able to simplify the control and at the same time increase the Diagnostic Coverage and avoiding spurious trips? Emerson has a one-stop-shop solution for HIPPS, addressing all the issues faced designing, building, installing and operating a HIPPS. The solution comprised of Virgo valves, Bettis actuators, Fisher FIELDVUE DVC6200 SIS digital valve controller, ASCO solenoids, AMS Suite, DeltaV SIS logic solvers, Rosemount pressure transmitters and a proven ball or butterfly valve for the final element of the solution. The solution not only provides quality Emerson control equipment with adequate certified failure data for all components, it also includes verification of the Safety Integrity Level and proof test, working procedures and inspection plans for the operator, to ensure the required safety is maintained throughout the safety life cycle. The solution will ensure requirements set by the end user are met, avoid any conflicts during validation, which might potentially delay start ups.

Understanding High Integrity Pressure Protection Systems (HIPPS) Emerson One-Stop-Shop for HIPPS Solutions HIPPS is a part of the Safety Instrumented System (SIS) and designed to prevent overpressure by shutting off the source and capturing the pressure in the upstream side of the system, thus providing a barrier between the High Pressure and Low Pressure sides of the process plant. The tight shutoff will prevent loss of the containment and eliminate fugitive emissions. HIPPS is seen as the last line of defense. A typical HIPPS will include 2 or 3 final elements in series and is often required to shutdown within 2-3 seconds for gas and 6-8 seconds for liquids, depending on the pipeline pressure, flow rate and the diameter and class of the pipeline. The initiator of the shut down sequence (peak pressure surge) will be detected by a pressure sensing system. In this case 3 sensors are connected to the logic solver, which is configured to vote with a 2oo3 logic (2 out of 3). If the predefined parameters for pressure are exceeded, the Logic Solver will shut down the final elements and the process. The 2oo3 configuration is usually preferred for HIPPS, as it provides availability as well as reliability for the system.

An All-Emerson Solution With Best-In-Class Products Emerson provides a true solution by utilizing well-known and proven safety products for our solution, configured and verified by certified Safety Consultants. Bettis Actuators Long-term reliability and speed of operation are important aspects of HIPPS. Bettis actuators are fully capable of meeting the fast closing speeds required in this application in addition to its compatibility with a wide range of devices for any application and, ability to operate in the harshest conditions for many years, with maximum reliability. Learn more about Bettis actuators at: www.emersonprocess.com/bettis Virgo Valves The valve serves as the critical core of the HIPPS solution, requiring a robust design to meet the most trying SIL 3 HIPPS specifications. Virgo trunnion and triple offset valves are all SIL 3 certified and can meet a variety of material, size and pressure requirements to operate quickly and reliably in demanding applications. Achieve the results you need with the best valve for your application: www.virgo-valves.com AMS Suite and ValveLink AMS Device Manager configures, calibrates, and diagnoses safety instruments and valves to ensure they will perform effectively when needed. The AMS ValveLink SNAP- ON application performs valuable valve diagnostics and automatically records all Partial Stroke Test results. ASCO Solenoid Valves Solenoid valves operating in remote locations for HIPPS applications require reliable lowpower operation and the ability to endure voltage surges. ASCO solenoid valves can deliver higher performance ratings for less power. This means less maintenance and power consumption for remote applications and increased reliability all-around. Know the best solenoids for you application. Visit: www.ascovalve.com/products AMS Suite Know that your safety equipment is in working condition: www.emersonprocess.com/ams Fisher FIELDVUE Digital Valve Controllers HIPPS requires Digital Valve Controllers that can withstand vibrations while providing alerts, trends and diagnostics for more extensive parameterization and tuning. When overpressure conditions are met, the system needs to operate the valve actuators quickly and FIELDVUE DVC6200 SIS digital valve controller can accomplish this for any HIPPS application in a patented linkage-less, non-contacting, explosionproof package. Perfect for almost all HIPPS applications as high vibration over time, will damage the linkages of most switches. Learn the benefits of using FIELDVUE digital valve controllers at: www.emersonprocess.com/fisher DeltaV SIS Process Safety System Faults, sensor readings and performance issues need to be monitored to reliably protect your assets. In HIPPS applications, this is of critical importance. When critical pressure spikes occur, sensors, logic solvers and final control elements need to perform on demand and the safety system integrates everything to keep it running safely. The system is certified for use in Safety Integrity Level (SIL) 3 applications without restriction. Improve your operations today. Visit the link below for more information: www.deltavsis.com Rosemount Pressure Transmitters The ability to accurately measure pressure reliably is critical in HIPPS applications. When overpressure occurs, your system must know quickly in order to engage the pressure protection system in time to protect your downstream equipment. The 3051S can detect plugged impulse line via SMART diagnostic (using HART), allowing DeltaV SIS to take appropriate action and increasing the Diagnostic Coverage of the HIPPS. Pressure, level and flow applications are all covered by Rosemount Pressure Transmitters. Gain better process insight, reduced process variability and reduced maintenance and downtime in a package that meets and exceeds regulatory demands. Know the best Rosemount measurement devices for your application: www.emersonprocess.com/rosemount

Emerson Safety Solution Specialists Bettis 19200 Northwest Freeway Houston TX 77065 Phone: +1 281 477 4100 Phone: +1 281 224 8588 (After Hours) Fax: +1 281 477 2801 Specialist: Carsten Thoegersen (carsten.thoegerson@emerson.com) DeltaV SIS 1100 W. Louis Henna Blvd. Building One Round Rock TX 78681-7430 Phone: +1 800 833 8314 Specialist: Tadeu Batista (tadeu.batista@emerson.com) Fisher 301 South 1st Avenue Marshalltown IA 50158 Phone: +1 641 754 3011 Phone: +1 641 754 2001 (After Hours) Fax: +1 641 754 2830 Specialist: Afton Coleman (afton.coleman@emerson.com) Virgo 6005 Rogerdale Road Houston TX 77072 Phone: + 1 281 933 3100 Fax: +1 281 933 3110 Specialist: Rajendra Deokar (rajendra.deokar@emerson.com) To get more detailed contact information by product and world area, scan QR. Emerson Process Management World Area Configuration Centers (WACC) offer sales support, service, inventory and commissioning to our global customers interested in automated valve solutions. Choose the WACC or sales office nearest you: NORTH & SOUTH AMERICA ASIA PACIFIC MIDDLE EAST & AFRICA EUROPE 19200 Northwest Freeway Houston TX 77065 T +1 281 477 4100 F +1 281 477 2809 Av. Hollingsworth 325 Iporanga Sorocaba SP 18087-105 Brazil T +55 15 3238 3788 F +55 15 3228 3300 No. 9 Gul Road #01-02 Singapore 629361 T +65 6501 4600 F +65 6268 0028 No. 1 Lai Yuan Road Wuqing Development Area Tianjin 301700 P. R. China T +86 22 8212 3300 F +86 22 8212 3308 P. O. Box 17033 Dubai United Arab Emirates T +971 4 811 8100 F +971 4 886 5465 P. O. Box 10305 Jubail 31961 Saudi Arabia T +966 3 340 8650 F +966 3 340 8790 24 Angus Crescent Longmeadow Business Estate East P.O. Box 6908 Greenstone 1616 Modderfontein Extension 5 South Africa T +27 11 451 3700 F +27 11 451 3800 Berenyi u. 72-100 Videoton Industry Park Building #230 Székesfehérvár 8000 Hungary T +36 22 53 09 50 F +36 22 54 37 00 For complete list of sales and manufacturing sites, please visit www.emersonprocess.com/valveautomationlocations or contact us at info.valveautomation@emerson. com 2016 Emerson Process Management. All rights reserved. The Emerson logo is a trademark and service mark of Emerson Electric Co. Bettis, Rosemount, Fisher and AMS Suite are marks of the Emerson Process Management family of companies. All other marks are property of their respective owners. DOC.6P.HIPPS.A4 Rev E 01-16 www.emersonprocess.com/bettis