Aztec ADS430 EZCLEAN Compressed air supply unit

Similar documents
Endura AZ40 Sensor assembly High temperature filter assembly kit

Endura AZ40 Sensor assembly Smart electronics PCB

Endura AZ40 Transmitter Main board spares kit

ATS430 turbidity sensor Retractable insertion assembly

9408 Series Dissolved Oxygen Systems. Dissolved oxygen systems designed for reliable operation with minimal operating costs

C1960. Multi-recipe profile recorder/controller. Measurement made easy

ABB MEASUREMENT & ANALYTICS DATA SHEET series Dissolved oxygen systems

Navigator 500 Dissolved oxygen analyzer. Measurement made easy. Accurate and reliable measurement of dissolved oxygen in high purity water

Model NDA Differential pressure transmitter. Deltapi N Series A complete range of pneumatic pressure transmitters

Pressure Automated Calibration Equipment

Navigator 600 Silica analyzers

PROPORTIONING VALVE. Model 150 INSTRUCTION MANUAL. March 2017 IMS Company Stafford Road

Endura AZ25 series probe Combustion oxygen monitor

Supplementary Operator s Manual 42/24-14 EN Rev. 3

9408 series Dissolved oxygen systems

CP10 Sensor Installation and Maintenance Instructions

The benefits of the extended diagnostics feature. Compact, well-proven, and flexible

SG36KTL-M Quick Installation Guide. 1 Unpacking and Inspection

SG33KTL-M Quick Installation Guide. 1 Unpacking and Inspection

ABB measurement & analytics data sheet. JAA, JAF and JAG Pneumatic indicating controllers

HUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation

Budget Range Operators Handbook

Infrared Linescanners

Operating Instructions. Ball valve fitting according to ZB For pressure transmitter VEGABAR 82. Document ID: 50027

Data sheet Pressure switch type CS December 2001 DKACT.PD.P10.A B1119

AP100 series ph/redox (ORP) cartridge sensors with water-wash option

ABB MEASUREMENT & ANALYTICS DATA SHEET. WaterMaster FEW530 Electromagnetic water meter

Pneumatic spool valve islands

Electronic gas volume corrector model DGVC-04

User and Installation Manual

User Manual. Quantos Automated Dosing Liquid Module

FICHA TÉCNICA DE PRODUTO

DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES

HumiSys HF High Flow RH Generator

Installation, operating and maintenance Instructions for Seemag bypass level indicator

AREA VALVE SERVICE UNITS

VERTICAL AIR COMPRESSORS

Spirax Compact FREME Flash Recovery Energy Management Equipment

Endura AZ30 series probe Combustion oxygen monitor. Proven technology for use in hazardous area gases and dusts

VERTICAL AIR COMPRESSORS

PositionMaster EDP300 Extended Diagnostics. Compact, well-proven, and flexible

ASE SOLVENT CONTROLLER INSTALLATION INSTRUCTIONS Dionex Corporation

IX1 Spirax-Monnier International Compressed Air Filter Installation and Maintenance Instructions

6900 Maintenance Instruction System Flush

combustion efficiency monitoring General Purpose Applications Flue gas oxygen analyzers Combustion & Environmental Monitoring An Company

2600T Series Pressure Transmitters Plugged Impulse Line Detection Diagnostic. Pressure Measurement Engineered solutions for all applications

FPD175 Compact orifice carrier assembly

Electro-Pneumatic Converter YT-940 SERIES

CCT-7320/ROC-2313 Reverse Osmosis Controller

Pressure Dump Valve Service Kit for Series 2300 Units

ABB MEASUREMENT & ANALYTICS DATA SHEET. Endura AZ40 Oxygen and carbon monoxide equivalent (COe) analyzer

Pressure Dump Valve Service Kit for Series 3000 Units

Manual Weighingblock VB2 series and Uniscale

AK100 Series ATEX Compliant Gas Analyzer System for Hydrogen-cooled Alternators

INSTALLATION COMMISSIONING, OPERATION & MAINTENANCE MANUAL

AUTOMATIC GAS MANIFOLDS

ABB MEASUREMENT & ANALYTICS DATA SHEET. AP100 ph/redox (ORP) cartridge sensors with water-wash option

Pegas 4000 MF Gas Mixer InstructionManual Columbus Instruments

MD R a n g e O p e r a t o r s H a n d b o o k

Pneumatic high-pressure controller Model CPC7000

SERIES 2 RAMP OWNER S MANUAL TOOLS REQUIRED: BEFORE YOU BEGIN... Read and understand these instructions before beginning a ramp setup.

MF2M Monnier Miniature Compressed Air Filter

Datasheet: K-30 ASCII Sensor

combustion efficiency monitoring Flue gas oxygen analyzers General Purpose Applications Combustion & Environmental Monitoring

Pressure maintenance valve SDV-P / SDV-P-E

Mounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator

CoriolisMaster mass flowmeter Diagnostics, verification and proof test

ACV-10 Automatic Control Valve

Pneumatic high-pressure controller Model CPC7000

Instructions for Assembly, Installation, and Operation of the Gas Addition Kit Accessory with the CEM Discover Systems

30T A/Manual Hydraulic Shop Press

ML3M Monnier Miniature Compressed Air Lubricator

CS Controlled Dissolved Gas assembly with optional CS Air Aspirator assembly. Installation and Operation information

DF-310E PROCESS ANALYSERS APPLICATIONS FEATURES

Specialists in HTM Medical Gas Pipeline Equipment AVSU/Module Operating and Maintenance Instructions

MP15 Jockey Pump Controller

RPS900W Redundant Power Supply. Installation Guide.

SM6. instructions for use. connection with compartment for incoming cable from the top. MV distribution factory built assemblies at your service

400H HARDMOUNT AIR COMPRESSOR KIT PART NO H HARDMOUNT AIR COMPRESSOR KIT PART NO

TANK MANAGER FOR TWO TANKS OPERATING MANUAL. 10/31/11 C-More T6C L color touch panel

Digital Melting Point Apparatus

100C Air Compressor Kit

BI-680 Online Dissolved Oxygen Controller Instruction Manual

Further technical information is available on

Series 6517 Katharometers. The ideal equipment for Process Monitoring and Control. Robust no moving parts. Designed for continuous industrial use

200 PSI COMPRESSORS - MODEL NUMBERS

Customer Responsibilities

Type 0404 / /2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation

Dissolved Oxygen Cartridge Electrode Systems

Customer Responsibilities

Automatic Isokinetic Sampler. ST5 Evo

Vertex VP Operation and Maintenance

IMPORTANT SAFETY INSTRUCTIONS

COMPRESSOR PACK SUCTION CONTROLLER TYPE: LP41x

PLEASE READ CAREFULLY BEFORE INSTALLING OR USING MEGA POOL SAVER MPS 1100

Arran LED Floodlight Luminaire

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

References 6 k thermal overload relays, adjustable from 0.11 to 16 A

ABB MEASUREMENT & ANALYTICS DATA SHEET. AK100 Series ATEX compliant gas analyzer system for hydrogen-cooled alternators

Installation and Operation Manual

Transcription:

Operating instruction OI/ADS430/EZCLN EN Rev. A Aztec ADS430 EZCLEAN Compressed air supply unit Measurement made easy Introduction The Aztec ADS430 EZCLEAN compressed air supply unit is a rugged, reliable cubicle that delivers compressed air to an ABB compressed air adaptor nozzle (part no. ADS430170) fitted to the probe or to an ABB probe flowcell (part no. ADS430160). For more information Publications for the associated Aztec AWT440 transmitter and Aztec ADS430 probe are available for free download from www.abb.com/measurement (see links and reference numbers below) or by scanning this code: The air supply (interval / type / duration / frequency / on-off sequencing) can be configured at the Aztec AWT440 transmitter to enable automatic / scheduled cleaning of the probe. Aztec AWT440 multi-input transmitter Commissioning instruction Aztec AWT440 multi-input transmitter Operating instruction Aztec ADS430 optical dissolved oxygen probe Operating instruction Aztec ADS430160 Flowcell pipeline mounting assembly Installation procedures Aztec ADS430170 EZCLEAN Compressed air adaptor Installation procedures search for or click on: CI/AWT440-EN OI/AWT440-EN OI/ADS430-EN INF14/157-EN INF14/158-EN

Contents 1 Health & Safety...3 1.1 Document symbols... 3 1.2 Safety precautions... 3 1.3 Potential safety hazards... 3 1.3.1 Electrical high voltage... 3 1.3.2 Compressed air supply... 3 1.3.3 Weight... 3 1.4 Safety standards... 3 1.5 Product symbols... 4 1.6 Product recycling and disposal (Europe only)... 4 1.7 Restriction of Hazardous Substances (RoHS)... 4 2 System overview...5 3 Installation...6 3.1 Wall-mounting... 6 3.2 Handrail / Wall-mounting... 7 3.3 Pole-mounting... 8 6 Maintenance... 13 6.1 Annual maintenance...13 7 Spares and Accessories... 14 7.1 Spares...14 7.1.1 Compressor mounting kits...14 7.1.2 Compressor maintenance kit...14 7.1.3 Tubing / tubing kit...14 7.1.4 Compressor assembly...14 7.1.5 Compressor pneumatic fittings kit...14 7.2 Accessories...14 7.2.1 Pole-mounting kit...14 7.2.2 Handrail-mounting kit...14 7.2.3 Compressor unit...14 8 Specification... 15 Acknowledgements... 15 4 Connections...9 4.1 Pneumatic connections... 9 4.1.1 Tubing to compressed air unit... 9 4.1.2 Tubing to ABB compressed air adaptor (ADS430170)... 9 4.1.3 Tubing to ABB flowcell (ADS430160)... 9 4.2 Electrical connections... 10 4.2.1 24 V DC supply (compressor unit to Aztec AWT440 transmitter)... 10 4.2.2 Mains voltage supply (230 or 115 V AC)... 10 5 Configuration...11 5.1 Sensor Setup... 12 2 OI/ADS430/EZCLN EN Rev. A Aztec ADS430 EZCLEAN Compressed air supply unit

1 Health & Safety 1.1 Document symbols Symbols that may appear in this document are shown below: DANGER Serious damage to health / risk to life This symbol in conjunction with the signal word 'DANGER' indicates an imminent danger. Failure to observe this safety information will result in death or severe injury. DANGER Serious damage to health / risk to life This symbol in conjunction with the signal word 'DANGER' indicates an imminent electrical hazard. Failure to observe this safety information will result in death or severe injury. WARNING Bodily injury This symbol in conjunction with the signal word 'WARNING' indicates a potentially dangerous situation. Failure to observe this safety information may result in death or severe injury. WARNING Bodily injury This symbol in conjunction with the signal word 'WARNING' indicates a potential electrical hazard. Failure to observe this safety information will result in death or severe injury. CAUTION Minor injuries This symbol in conjunction with the signal word 'CAUTION' indicates a potentially dangerous situation. Failure to observe this safety information may result in minor or moderate injury. The symbol may also be used for property damage warnings. NOTICE Property damage This symbol indicates a potentially damaging situation. Failure to observe this safety information may result in damage to or destruction of the product and / or other system components. 1.2 Safety precautions Be sure to read, understand and follow the instructions contained within this manual before and during use of the equipment. Failure to do so could result in bodily harm or damage to the equipment. WARNING Bodily injury Installation, operation, maintenance and servicing must be performed: by suitably trained personnel only in accordance with the information provided in this manual in accordance with relevant local regulations 1.3 Potential safety hazards 1.3.1 Electrical high voltage The Aztec ADS430 EZCLEAN air compressor unit requires a 230 or 115 V AC mains supply to operate. A mains isolation switch must be fitted in the supply to the unit. 1.3.2 Compressed air supply The Aztec ADS430 EZCLEAN system generates compressed air up to a pressure of 50.7 psi(g) / 3.5 bar(g) maximum. do not use compressed air for any other purpose than that for which it is provided never direct a stream of compressed air towards your body or the body of any other person when handling / connecting compressed air lines: the correct safety procedures must be observed suitable PPE must be worn (goggles / gloves / overalls) 1.3.3 Weight The Aztec ADS430 EZCLEAN air compressor unit weighs approximately 10.3 kg (22.6 lbs.). The unit must be lifted only using appropriate lifting equipment / personnel and in accordance with relevant Health & Safety procedures and requirements. 1.4 Safety standards This product has been designed to satisfy the requirements of IEC61010-1:2010 3rd edition 'Safety Requirements for Electrical Equipment for Measurement, Control and Laboratory Use' and complies with US NEC 500, NIST and OSHA. IMPORTANT (NOTE) This symbol indicates operator tips, particularly useful information or important information about the product or its further uses. The signal word 'IMPORTANT (NOTE)' does not indicate a dangerous or harmful situation. Aztec ADS430 EZCLEAN Compressed air supply unit OI/ADS430/EZCLN EN Rev. A 3

1.5 Product symbols Symbols that appear on this product are shown below: Functional earth (ground) terminal. Direct current supply only. This symbol, when noted on a product, indicates a potential hazard which could cause serious personal injury and / or death. The user should reference this instruction manual for operation and / or safety information. This symbol identifies a risk of chemical harm and indicates that only individuals qualified and trained to work with chemicals should handle chemicals or perform maintenance on chemical delivery systems associated with the equipment. This symbol indicates the need for protective eye wear. This symbol indicates the need for protective hand wear. Recycle separately from general waste under the WEEE directive. 1.6 Product recycling and disposal (Europe only) Electrical equipment marked with this symbol may not be disposed of in European public disposal systems after 12 August 2005. To conform to European local and national regulations (EU Directive 2002/96/EC), European electrical equipment users must now return old or end-of-life equipment to the manufacturer for disposal at no charge to the user. ABB is committed to ensuring that the risk of any environmental damage or pollution caused by any of its products is minimized as far as possible. IMPORTANT (NOTE) For return for recycling, please contact the equipment manufacturer or supplier for instructions on how to return end-of-life equipment for proper disposal. 1.7 Restriction of Hazardous Substances (RoHS) The European Union RoHS Directive and subsequent regulations introduced in member states and other countries limits the use of six hazardous substances used in the manufacturing of electrical and electronic equipment. Currently, monitoring and control monitors do not fall within the scope of the RoHS Directive, however ABB has taken the decision to adopt the recommendations in the Directive as the target for all future product design and component purchasing. 4 OI/ADS430/EZCLN EN Rev. A Aztec ADS430 EZCLEAN Compressed air supply unit

2 System overview Aztec ADS430 EZCLEAN components are shown in Fig. 2.1: Fig. 2.1 Aztec ADS430EZCLEAN components Item Feature Item Feature A Compressor motor J Air out bulkhead push-fit coupling (to 6 mm nylon tubing) B Compressor head K Cable gland entry (mains supply voltage cable) C Air muffler / filter L Mains supply voltage connector D Air out to compressed air adaptor or flowcell M M12 cable gland (digital I/O cable to transmitter) E Pressure relief valve N M20 cable gland (mains supply voltage) F Switching relay O Air intake (including dust filter) G Fuse (2 A anti-surge) P Instrument label H Low voltage digital I/O connector Q Door locks I Cable gland entry (low voltage digital I/O) Table 2.1 Aztec ADS430EZCLEAN component descriptions Aztec ADS430 EZCLEAN Compressed air supply unit OI/ADS430/EZCLN EN Rev. A 5

3 Installation WARNING Bodily injury Unit weight 10.3 kg (22.6 lbs.). Mount in accordance with relevant safety requirements using suitable equipment and personnel. 3.1 Wall-mounting This procedure is for wall-mounting using the 4 x plastic wall-mounting lugs and M6 screws / washers (supplied). The lugs can be attached to the unit in the vertical- or horizontal-plane. When choosing the mounting location, leave sufficient space in front of the unit to open the door fully (280 mm [11.0 in.]). Referring to Fig. 3.1: 1. Fit the 4 x mounting lugs A to the compressor unit B in the required plane and secure using the M6 screws / washers C. 2. Mark appropriate mounting lug screw hole locations on the wall and drill suitably-sized holes to accommodate the mounting location disks D and fixings E (not supplied). Note Ensure the keyhole slots in location disks D are aligned correctly. 3. Mount the compressor unit to the wall. Dimensions in mm (in.) 330 (13.0) 381 (15.0) 262 (10.3) 420 (16.5) 395 (15.5) 196 (7.7) 440 (17.3) 205 (8.1)* *Add 280 (11.0) when door open Fig. 3.1 Wall-mounting 6 OI/ADS430/EZCLN EN Rev. A Aztec ADS430 EZCLEAN Compressed air supply unit

3.2 Handrail / Wall-mounting This procedure is for handrail / wall-mounting using the optional compressor unit handrail-mounting kit (part no. ADS430195). When choosing the mounting location, leave sufficient space in front of the enclosure to open the door fully (>485 mm [>19.1 in.]). NOTICE Optional compressor mounting extension plates (D in Fig. 3.2 [2 supplied with handrail mounting kit part no. ADS430195]) can be attached to handrail mounting plates if required Referring to Fig. 3.2: 1. Fit the 4 x handrail mounting plates A to the compressor unit B in the required plane and secure each plate with one M6 screw C (supplied). If optional extension mounting plates D are required, attach to the handrail mounting plate(s) in the required plane using 2 x M6 bolts / washers / nuts (supplied) per plate. 2. Position the compressor unit B on the handrail and secure using the U-bolts E and M8 nuts / washers F (supplied). Dimensions in mm (in.) 50 (1.9) U-bolt / 210 (8.3) + 25 (1.0) 42 (1.6) U-bolt / 210 (8.3) + 21 (0.8) 330 (13.0) * 420 (16.5) 395 (15.5) * 385 (10.1) 262 (10.3) 170 (6.70) 195 (7.67) * 205 (8.1) ** 486 (19.1) * *Mounting plates A, U-bolts E and extension plates D can be fitted horizontally or vertically in each corner of the enclosure. Arrangements above shown for example only. **485 (19.1) with door open Fig. 3.2 Handrail-mounting 70 (2.75) Aztec ADS430 EZCLEAN Compressed air supply unit OI/ADS430/EZCLN EN Rev. A 7

3.3 Pole-mounting This procedure is for pole-mounting using the optional pole-mounting kit (part no. ADS430197). When choosing the mounting location, leave sufficient space in front of the unit to open the door fully (280 mm [11.0 in.]). Referring to Fig. 3.3: 1. Fit the pole mounting plate A to the compressor unit B and secure using the M6 screws C (supplied). 2. Position the compressor unit B on the pole and secure using the U-bolt D and M8 nuts / washers E (supplied). Note It is not usually necessary to fit a second pole mounting plate (and U-bolt) to the bottom of the enclosure but, if necessary, an additional kit (ADS430197) is required. Dimensions in mm (in.) 330 (13.0) 50 (1.9) U-bolt 205 (8.1) + 25 (1.0) 42 (1.6) U-bolt 205 (8.1) + 21 (0.8) 420 (16.5) 395 (15.5) 205 (8.1)* *Add 280 (11.0) when door open Fig. 3.3 Pole-mounting 8 OI/ADS430/EZCLN EN Rev. A Aztec ADS430 EZCLEAN Compressed air supply unit

4 Connections 4.1 Pneumatic connections WARNING Bodily injury The Aztec ADS430 EZCLEAN system develops compressed air up to a pressure of 50.7 psi(g) / 3.5 bar(g) maximum (when outlet blocked [zero flow]). do not use compressed air for any other purpose than that for which it is provided never direct a stream of compressed air towards your body or the body of any other person when handling / connecting compressed air lines: the correct safety procedures must be observed suitable PPE must be worn (goggles / gloves / overalls) 4.1.2 Tubing to ABB compressed air adaptor (ADS430170) 1. Refer to INF14/158-EN to fit the compressed air adaptor to the probe. Referring to Fig. 4.2: 2. Connect the free end of 6 mm OD nylon tubing A to G3/8 connector B on the compressed air adaptor C: WARNING Bodily injury Typical pressure and flowrate 20 psi(g) / 1.38 bar(g) @0.5 scfm (14.16 L/min), set to perform every 4 hours. 4.1.1 Tubing to compressed air unit Referring to Fig. 4.1: 1. Connect one end of the 6 mm OD nylon tubing A to bulkhead push-fit connector B. Fig. 4.2 Connecting 6 mm OD nylon tubing to the ABB compressed air adaptor 3. Proceed to Section 4.2, page 10 to make electrical connections. 4.1.3 Tubing to ABB flowcell (ADS430160) 1. Refer to INF/157-EN to fit the probe into the ABB flowcell. Referring to Fig. 4.3: 2. Connect the free end of 6 mm OD nylon tubing A to G3/8 connector B on the ABB flowcell C: WARNING Bodily injury Typical pressure and flowrate 20 psi(g) / 1.38 bar(g) @0.5 scfm (14.16 L/min), set to perform every 4 hours. Sample in Sample out Fig. 4.1 Connecting 6 mm OD nylon tubing to the compressed air unit 2. Proceed to: Section 4.1.2 to connect 6 mm OD nylon tubing to ABB compressed air adaptor (ADS430170) Section 4.1.3 to connect 6 mm nylon OD tubing to ABB flowcell (ADS430160) Fig. 4.3 Connecting 6 mm OD nylon tubing to the ABB flowcell typical arrangement 3. Proceed to Section 4.2, page 10 to make electrical connections. Aztec ADS430 EZCLEAN Compressed air supply unit OI/ADS430/EZCLN EN Rev. A 9

SK1 SK2 5 COMMS RS485 SMART SENSOR INTERFACE MODULE CM40/0215 ISS. 1 OUT 1 OUT 2 SK4 ANALOGUE OUTPUT BOARD CM40/0235 + + SK5 OUT 3 OUT 4 RELAY 5 RELAY 6 RELAY 1 RELAY 2 RELAY 3 RELAY 4 N L 4.2 Electrical connections 4.2.1 24 V DC supply (compressor unit to Aztec AWT440 transmitter) WARNING Bodily injury Isolate the compressed air unit and Aztec AWT440 transmitter from the mains power supply before making electrical connections. Ensure all cable runs are safe and do not present a trip hazard when routing / securing. Referring to Fig. 2.1, page 5: 1. Release the 2 door locks Q and open the compressed air unit door. Referring to Fig. 4.4: 2. Loosen the M12 cable gland entry on the base of the compressed air unit and pass one end of the sheathed twin-core connection cable through. Pass the other end of the cable through the required cable gland entry on the transmitter refer to the transmitter Operating instruction (OI/AWT440-EN) for gland entry options. 3. Make connections between the compressed air unit and transmitter. 4. Tighten low voltage cable glands on compressed air unit and transmitter. 5. Proceed to Section 4.2.2 to make the mains voltage supply connection to the compressed air unit. 4.2.2 Mains voltage supply (230 or 115 V AC) WARNING Bodily injury Isolate the compressed air unit and Aztec AWT440 transmitter from the mains power supply before making electrical connections. Ensure the voltage supply matches the supply voltage specified on the instrument label P fitted within the enclosure before making connections see Fig. 2.1, page 5. Ensure all cable runs are safe and do not present a trip hazard when routing / securing. Referring to Fig. 4.5: 1. Loosen the M20 cable gland entry on the base of the compressed air unit and pass the free end of the 3-core mains supply cable through. 2. Make mains power supply connections to the compressed air unit Neutral / Earth / Live terminals. 3. Tighten the M20 mains supply voltage cable gland. 4. Close and lock the compressed air unit door refer to Fig. 2.1, page 5. 5. Proceed to Section 5, page 11 to configure the cleaning schedule. Compressed air unit 24 V DC relay 2 A anti-surge fuse (beneath cover) MAINS INPUT 115V/230V MAINS INPUT 115V/230V M12 cable gland entry (24 V DC cable) To DI01 to DI06 terminal on transmitter (assign terminal ID (1 to 6) at Input/Output / Digital I/O / Digital I/O 1 (to 6) parameter see OI/AWT440-EN + To INT + 24V terminal on Aztec AWT440 transmitter Earth Neutral NE L Live M20 cable gland entry (230 / 115 V AC mains supply cable) Fig. 4.5 Mains supply voltage 230 or 115 V AC connections Aztec AWT440 transmitter COMMUNICA TIONS MODULE COM COM RED BLACK SCREEN WHITE GREEN I/O MODULE 2 I/O MODULE 3 FUSE RATING 3.15A (T) ~100 240V 50/60 Hz INT +24V 1 2 3 4 + + DIO1 DIO2 DIO3 DIO4 DIO5 DIO6 DIO COM COM COM COM COM INT +24V DIO1 DIO2 DIO3 DIO4 DIO5 DIO6 DIO COM To positive (+) connection on compressed air unit 24 V DC relay To negative ( ) connection on compressed air unit 24 V DC relay Fig. 4.4 24 V DC connections compressed air unit to Aztec AWT440 transmitter 10 OI/ADS430/EZCLN EN Rev. A Aztec ADS430 EZCLEAN Compressed air supply unit

5 Configuration Press the key the Sensor Setup page is displayed: NOTE Schedule automatic cleans for configured probe(s) only. Clean parameters are enabled only when the Clean Interval is set (is not Off) see Section 5.1, page 12. Full software details are detailed in the transmitter Operating instruction (OI/AWT440-EN). 1. Ensure the Aztec ADS430 probe to be cleaned is connected to the transmitter. 2. Ensure pneumatic connections are made between the Aztec ADS430 EZCLEAN compressed air unit and either an ABB flowcell mounting assembly (part no. ADS430160) or an ABB compressed air adaptor (part no. ADS430170 / 171) to be fitted on the probe. 3. Ensure electrical connections are made between the Aztec ADS430 EZCLEAN compressed air unit and the Aztec AWT440 transmitter see Section 4.2, page 10. 4. At the Aztec AWT440 transmitter, press the key to display the Operator Page menu, then select Enter Configuration to display the Access Level page. Use the key to select the Advanced menu item and press the key (below the Select prompt) to access Advanced level menus. Use the / keys to scroll to the Input/Output menu and press the key to enter the level. Scroll to the Digital I/O / Digital I/O 1 (to 6) menu using the / keys. Configure digital output parameters for the associated probe as follows: Set: Type to Output Set: Source to Sx Clean (where x corresponds to the sensor position [1 to 4] at the EZLink connector) Set: Polarity to Inverted 5. Exit the Input/Output menu and use the / keys to scroll to the Sensor Setup menu: Sensor Setup S1 :RDO Salinity Units Pressure Units Back 6. If more than 1 sensor is connected, select the required sensor S1(to 4) :RDO (to be cleaned) and press the key (below the Select prompt). The sensor S1(to 4) :RDO menu page is displayed see Section 5.1, page 12: S1(to 4) :RDO Tag PV Type Units Range High Range Low Filter Type Back 7. Scroll to the Clean Interval menu and set the required interval between cleans. S1(to 4) :RDO Clean Interval Clean Type Clean On Time Clean Off Time Number of Pulses Recovery Time Back Select Select Select 8. Set the required clean parameters (Clean Type / Clean On Time / Clean Off Time* / Number of Pulses* / Recovery Time / Clean Duration / Clean Output) for the connected probe. *Enabled only if Clean Type is set to Pulsed. 9. When all required clean parameters are set, press the key repeatedly to exit the Sensor Setup level and return to the Operator Page. 1 23 1 23 1 23 Menu Sensor Setup The configured clean commences at the interval set after this configuration is saved and repeats until re-configured or stopped. Exit Select Aztec ADS430 EZCLEAN Compressed air supply unit OI/ADS430/EZCLN EN Rev. A 11

5.1 Sensor Setup Menu Sensor Setup Used to set the tag, measurement units, operational range and clean functions and to compensate for salinity and barometric pressure. Exit Select Menu Comment Default S1 (to 4) :RDO Select the ID of the optical dissolved oxygen probe to be cleaned and scroll to the Clean Interval menu to configure the cleaning routine. Tag PV Type Units Range High Range Low Filter Type These parameters are not used to configure cleaning refer to the Aztec ADS430 probe Operating instruction (OI/ADS430-EN) for parameter descriptions. Clean Interval Set the interval between cleans: Off / 15 Mins. / 30 Mins. / 45 Mins. / 1 to 24 Hours Off Clean Type * Set the clean type: Continuous / Pulsed Continuous Clean On Time * Set the duration of the clean: 1 to 60 Secs 30 Secs Clean Off Time * / ** Set the duration between cleans: 1 to 60 Secs 30 Secs Number of Pulses * / ** Set the number of cleaning pulses: 1 to 10 Pulses 2 Pulses Recovery Time * Set the time delay between the completion of cleaning and the display of a new reading on the operator page: 1 to 10 Min. 1 Min. Clean Duration * Displays the total duration of the clean: Clean Type set to Continuous = Clean on Time + Recovery Time Clean Type set to Pulsed = (Clean on Time + Clean Off Time) x Number of Pulses + Recovery Time Clean Output * Displays the output signal the clean is assigned to. This can be set to relay 1 to 6 or digital output 1 to 6 refer to Aztec AWT440 transmitter Operating instruction (OI/AWT440-EN). No Assignment Salinity Correction Barometric Pressure Restore Defaults Salinity Units Pressure Units These parameters are not used to configure cleaning refer to the Aztec ADS430 probe Operating instruction (OI/ADS430-EN) for parameter descriptions. * Displayed only if Clean Interval is NOT set to Off ** Displayed only if Clean Type is set to Pulsed 12 OI/ADS430/EZCLN EN Rev. A Aztec ADS430 EZCLEAN Compressed air supply unit

6 Maintenance 6.1 Annual maintenance 1. Ensure compressed air supply unit mountings are secure. 2. Ensure push-fit couplings and 6 mm tubing are in serviceable condition see Section 4.1, page 9. 3. Ensure the air intake is clean see Section 2, page 5, item O. 4. Ensure the air muffler / filter is clean and free of clogged pores see Section 2, page 5, item C. To clean this, remove from the compressor head and blow oil-free compressed air through it from the reverse side. If the unit operates in a dusty environment, additional periodic cleaning may be required use only a clean, dry cloth. Aztec ADS430 EZCLEAN Compressed air supply unit OI/ADS430/EZCLN EN Rev. A 13

7 Spares and Accessories 7.1 Spares 7.1.1 Compressor mounting kits ADS430053 ADS430054 ADS430055 Wall-mounting kit, comprising: M6 screws and washers x 4 compressor unit enclosure mounting plates x 4 Handrail-mounting kit, comprising: U-bolt x 4 with washer and nut M6 screws and washers x 4 ea. compressor unit enclosure mounting plates x 4 Pole-mounting kit, comprising: U-bolts x 4 M6 screws and washers x 4 compressor unit enclosure mounting plate Table 7.1 Aztec ADS430 EZCLEAN compressor mounting kits 7.1.2 Compressor maintenance kit ADS430056 Maintenance kit, comprising: 15 m (45 ft.) x 6 mm OD nylon tubing G3/8 push-fit connector replacement air muffler / filter fuse Table 7.2 Aztec ADS430 EZCLEAN compressor maintenance kit ADS430056 7.2 Accessories 7.2.1 Pole-mounting kit ADS430197 7.2.2 Handrail-mounting kit 7.2.3 Compressor unit Compressor pole-mounting kit Table 7.7 Aztec ADS430 EZCLEAN compressor pole-mounting kit ADS430197 ADS430195 Compressor handrail-mounting kit, includes 4 x handrail / wall mounting plates, 2 x extension plates, U bolts, nuts and washers Table 7.8 Aztec ADS430 EZCLEAN compressor handrail-mounting kit ADS430195 ADS430050 ADS430051 EZCLEAN compressor unit, including housing: 230 V AC 115 V AC Table 7.9 Aztec ADS430 EZCLEAN compressor unit 230 and 115 V AC 7.1.3 Tubing / tubing kit ADS430175 7.1.4 Compressor assembly 15 m (45 ft.) x 6 mm OD nylon tubing Table 7.3 6 mm OD nylon tubing ADS430175 ADS430169 Tubing and connector comprising: 15 m (45 ft.) x 6 mm OD nylon tubing G3/8 push-fit connector Table 7.4 Air cleaning tubing kit ADS430169 ADS430052 Replacement compressor assembly (compressor only) Note. Voltage (230 or 115 V AC) must be configured by end-user. Refer to instructions supplied with compressor. Table 7.5 Aztec ADS430 EZCLEAN compressor assembly ADS430052 7.1.5 Compressor pneumatic fittings kit ADS430056 Compressor pneumatic fittings kit Table 7.6 Aztec ADS430 EZCLEAN compressor pneumatic fittings kit ADS430056 14 OI/ADS430/EZCLN EN Rev. A Aztec ADS430 EZCLEAN Compressed air supply unit

8 Specification Compressed air unit Dimensions* Height: 395 mm (15.5 in.) Width: 330 mm (13.0 in.) Depth: 205 mm (8.1 in.) Enclosure material Polypropylene Pump unit Power 90 W Pressure relief valve Set to vent to atmosphere if pressure exceeds 20 psi(g) / 1.38 bar(g) Pneumatic pressure / flow rate Maximum pressure: outlet closed: 50.7 psi(g) / 3.5 bar(g) outlet open: 30 psi(g) / 2.0 bar(g) Typical operating pressure and flowrate 20 psi(g) / 1.38 bar(g) @0.5 scfm (14.16 L/min), set to perform every 4 hours TORR BAR 0 200 400 600 760 0.5 1.0 1.5 2.0 0.9 25 0.8 0.7 20 LITRES/M Environmental ratings Storage temperature 20 to 50 C ( 4 to 122 F) Operating temperature 20 to 50 C ( 4 to 122 F) Power requirements Mains power supply 230 or 115 V AC, 90 W Internal fuse 2 A, anti-surge Digital I/O** 24 V DC Cable entries Mains voltage supply cable M20 cable gland Digial I/O cable** M12 cable gland Pneumatic entry Bulkhead push-fit connector for 6 mm nylon tubing Compliance CE *Excluding mounting brackets, see Section 3, page 6 for bracket dimensions **From digital I/O in transmitter or an external supply via the transmitter relay SCFM 0.6 0.5 0.4 0.3 0.2 0.1 15 10 5 Acknowledgements RDO is a registered copyright of In-Situ Inc. 30 20 10 0 10 INS HG PSIG Fig. 8.1 Pump unit pneumatic pressure / flow rate 20 30 Aztec ADS430 EZCLEAN Compressed air supply unit OI/ADS430/EZCLN EN Rev. A 15

Contact us ABB Limited Process Automation Howard Road, St. Neots Cambridgeshire, PE19 8EU UK Tel: +44 (0)870 600 6122 Fax: +44 (0)1480 213 339 Mail: enquiries.mp.uk@gb.abb.com ABB Inc. Process Automation 125 E. County Line Road Warminster, PA 18974 USA Tel: +1 215 674 6000 Fax: +1 215 674 7183 Note We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB. Copyright 2015 ABB All rights reserved 3KXA494431R4201 OI/ADS430/EZCLN EN Rev. A 03.2015 www.abb.com Sales Service