REV: 03/17. User Manual

Similar documents
QUIK-jet Micro-Injection System

Macro-Infusion Guide

Speed control assembly model A-1

Exercise 2-3. Flow Rate and Velocity EXERCISE OBJECTIVE C C C

Installation of Your SprayMaster System

Nrtheastern Forest 'Experiment Statiou

!!!! SERVICE MANUAL PRESSURE POT 2 GALLON. Service Manual: LT Washington St 931 Progress Ave., #7

Pressure Dump Valve Service Kit for Series 2300 Units

5/16 MAXFLOW SPOUTS 17/64 MAXFLOW SPOUTS. 5/16 black spout with barbs $0.25 $ /64 white spout without barbs. 5/16 white spout without barbs

HPB25 Hydraulic Paving Breaker

Pressure Dump Valve Service Kit for Series 3000 Units

Binks SG-2 Plus TM 2 QT. PRESSURE CUPS Model No (Standard) Model No (with OscillatingAgitator)

PRO SINK -R 1 and 2. Dilution system CONTENTS

Halsey Taylor Owners Manual STOP!

FOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM

Operating Instructions Models and Hydrostatic Test Pumps

REVERSE OSMOSIS WATER FILTRATION SYSTEM MODEL EWR 4075 INSTRUCTION MANUAL

Operating Instructions Model and Hydrostatic Test Pump

Hot Tapping Machine. OPERATIONS MANUAL and OPERATING INSTRUCTIONS

MODEL 840 AIR HYDRAULIC PUMP INSTRUCTION

G7S Hand Pump Owner s Manual

Halsey Taylor Owners Manual 4410 Freeze Resistant Tubular Fountain STOP!

CS150 CAP STAPLER OWNER S MANUAL

Operation Manual Guillotine Cutter RC-5

HPIC D Hydrostatic Test Pump PRODUCT INFORMATION AND OPERATING INSTRUCTIONS

Columbia Taping Tools. Hydra Reach Handle. Manual

RIX COMPRESSORS. MICROBOOST Owner s Manual CONFIGURATION A MB-115 MB-230. November 21, 2002 APPLICABILITY [ A]

ATD LB PRESSURE BLASTER INSTRUCTION MANUAL

Combination Air Valve Model

2 CYLINDER MOBILE CART USER S MANUAL / INSTRUCTIONS

Operating Instructions Models 36200, , 46200, Hydrostatic Test Pumps

User's Manual. MixRite TF 10. Edition 05.08

HYDRAULIC PUNCH DRIVER 38456, 38520, 7306 / 7306SB, 7310 / 7310SB, 7506, 7606SB, 7610SB, 7625 / 7625Pg / 7625PgSB, 7646 / 7646Pg / 7646PgSB

Continental Industries STEEL SERVICE TEES or FAX Visit

Pressure Regulating Valve. O&M Manual. PRV-15K Part # ,000 PSI MAWP. PRV-20K Part # ,000 PSI MAWP

WIDDER TOOLS. HPICAL Calibration Station 1 (203)

ABRASIVE REGULATOR II

ASSEMBLY & USE MANUAL

Continental Industries TRANSITION FITTINGS or FAX Visit

Instruction Manual Updated 7/26/2011 Ver. 2.2

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

Carbon Fiber Tank with EZ Fill system Fill pressure 4,500 psi (310 bar) Output: up to 4,500 psi (310 bar)

OFI Testing Equipment - Aging Cell Instructions Page 1 of 4. Instructions OFITE AGING CELLS

ABRASIVE REGULATOR II

Installation, Operation, and Maintenance Manual. Welker Constant Pressure Cylinder With Solid Indicator (Non-mixer) Model CP-30SI

H4802, H4802-1, H , and Pole Tampers

Operating Instructions Model and Hydrostatic Test Pump

Needle valve. Contents. User s Manual. (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2

Pressure Injection Cell Operator s Manual

600 o F High Temperature Aging Cell Instruction Manual

RST INSTRUMENTS LTD.

Installation, Operation, and Maintenance Manual

LARGE DRY CHEMICAL, TWIN-AGENT, AFFF, HALON 1211, AND AQUASONIC (NITROGEN-OPERATED SYSTEMS) Pressure Regulator Test Manual

Inflatable Packer Single & Double. Single & Double Packer Dimension. Wireline Packer. Water Testing Packer (WTP) Packer

Syringe, Distribution Valve and Infusion Pump Removal/Replacement ATTENTION SYRINGE REPLACEMENT

Flexi-pro Aerosol Delivery System (FADS) Manual

START UP MANUAL MADE IN USA REV US and Foreign patents and patents pending see

Hot Compressed Air Lance Operation Manual. LAB Manufacturing 9483 Reading Road Cincinnati, OH (800)

REV0709. Parts List. Hydraulic Cylinder Model MODEL C SINGLE-ACTING, SPRING RETURN HYDRAULIC CYLINDER. Max. Capacity: 55.2 Tons at 10,000 PSI

Wafer Check Valve. Contents. User s Manual. (1) Be sure to read the following description of our product warranty 1

Combination Air Valve

Techcon Systems TS1258 Pressure Pot

FITTINGS THREAD LUBRICANTS. Fittings 20,000 PSI

PARTS LIST FOR CM MMB

BioAerosol Nebulizing Generator. Operation and Maintenance User Manual

Booster Pump PB4-60 Replacement Kits

Operators Manual. Supera Floor Stand Anesthesia Machine M1000. Models: M1000 Basic Non-rebreathing M1200 Basic M1200

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP

Operation Manual. Diaphragm Sensed Gas Pressure Regulators

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

AIR DRIVE ROLL FEED CARTON STAPLER MODEL: H-1031 MANUAL

Chemical Injection Technologies Installation/Service Bulletin

INSTRUCTION MANUAL MST AFTERCOOLER SYSTEM MODEL

Safe-T-Stopper. Gas-Free* Service Tee Renewal and Removal for CenterPoint Energy. *In a controlled gas environment

Paintball Marker. User s Manual. 530 South Springbrook Road Newberg, OR 97132

Tridak Model 1050 User Guide

Inside Front cover This page will remain blank.

Tribomatic II Powder Pump

STREAMLINE SHOP SERIES MODEL OPERATION & PARTS MANUAL

Operating Instructions Models and Hydrostatic Test Pumps

FLEXIBLE SHAFTING (Wet & Dry)

Installation Operating Instructions for Simple Duplex Manual Manifolds PX-TSD Series

CO2 Tank Conversion Kit P.N , P.N , and P.N

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

Water Weir Flow Controller. Introduction. Safety Precautions. Mounting the Hardware

Operating Instructions Models and Hydrostatic Test Pumps

Bottle Rocket Launcher P4-2000

Gas Lines. Technical Manual. Sumitomo (SHI) Cryogenics of America, Inc Vultee Street Allentown, PA U.S.A.

Pure Water Power Purification System 4-Stage RODI Operations Manual

2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL

Multi-Probe Sampling System User Guide & Manual

HGC-200 Hydro Gas Chlorinator

Binks SG-2 Plus TM Rotary 2 QT. PRESSURE CUP

P5513. Users Manual. Pneumatic Comparison Test Pump. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

Instruction Manual Updated 6/22/06 Ver. 2.0

Converting a 2006 Royal Enfield Classic to a Kick Start Only Machine. There are good reasons for not having an electric start.

HP-104 & HP-106 Tapping Machine OPERATIONS MANUAL

MUELLER. Mega-Lite Drilling Machine. Reliable Connections. table of contents PAGE. Equipment 2. Operating Instructions 3-4. Parts Information 5

Operation Manual Piston Sensed Gas Pressure Regulators

Transcription:

REV: 03/17 User Manual

2 Table of Contents Part 1: Introduction to FSeries Introduction to FSeries Micro-infusion 3 Parts of the FSeries Kit 4 3 Easy Steps for the FSeries 5 Part 2: Setting up the FSeries Set Up: How to Assemble the FSeries 6 Set Up: Prepare the FSeries 7 Set Up: Pressurize & Prime Supply Lines 8 Set Up: Select Arborplug Sites 9 Part 3: Using the FSeries Procedure: Drill Sites for Arborplugs 10 Procedure: Set the Arborplugs 11 Procedure: Micro-infusion with the FSeries 12 Procedure: Using Multiple FSeries 13 Procedure: Large Tree Micro-infusion 14 Procedure: Conifers vs. Deciduous 15 Part 4: FSeries Maintenance & Miscelaneous Maintenance: Cleaning FSeries 16-17 Maintenance: General 18 Optional: Plugless VIPER Method for FSeries 19-20 FSeries Replacement Parts 21-24

3 Introduction to FSeries Micro-infusion System Arborjet s FSeries Micro-infusion system was developed to effectively deliver high volumes of injectable product into the sapwood of any type of tree. It enables the applicator to precisely deliver an accurate, measured dose of insecticide, fertilizer or fungicide into the xylem tissue in a safe and environmentally friendly way. The FSeries can utilize either VIPER or STINGER micro-infusion interface technology. VIPER - Volume-Injection Pressure-Enhanced Reservoir Uses Arborplug Arborplug is the plug inserted into the Sapwood VIPER Needle is the name of the Micro-infusion Needle VIPER Method is the procedure for the Micro-infusion using Arborplug and VIPER needle. When to use VIPER: Faster Uptake Closed Infusion Site No leakage Faster Wound Closure Conifers Infection Prone Trees STINGER Stick-Inject-Remove (Does not use Arborplug) Does not use Arborplug STINGER Needle is the name of the Micro-infusion needle and tip. STINGER Method is the procedure for the Micro-infusion using STINGER needle. When to Use STINGER: Faster Set Up Simpler process Ring Porous Trees Non-Arborists

4 Parts of the F12 Kit (070-0010) Bottle & Cap Assembly (070-0075) Pressure Pump (070-0090) F-Series Tool Kit: (070-0240) 6 Gallon Bucket (070-0215) F-Series Stand 4-Pack: (070-0210) Hex PDS (070-0085) Mixing and Measuring Kit: (070-0104) Includes: Graduated Cylinder Funnel Carrying Cup CLEAN-jet ½ L (030-2035) Reorder: 1 L (030-2030)

5 3 Easy Steps for the F-Series 1. DRILL 2. PLUG 3. INJECT SAFETY REMINDER Always wear safety glasses and gloves when handling equipment and products.

How to Assemble the F-Series Insert VIPER needle into ball valve assembly Insert tubing firmly into PTC (Push To Connect) fittings.

Prepare the F-Series for Micro-infusion Determine the DBH (Diameter at Breast Height in inches). Measure tree diameter in inches, at breast height by using a diameter tape, OR measure circumference and divide by Pi (3.1415). 2. Read product label and use DBH to determine total injection volume for entire treatment application and how many bottles will be needed for application. Each 650 ml bottle has 400 ml capacity; each 1.5 liter bottle has 1 liter (1000 ml) capacity. 3. Measure volume in graduated cylinder. 4. Pour into FSeries bottle(s) using funnel. IMPORTANT - 400 ml or 1000 ml capacity- There must be air space in the bottle for air pressure, otherwise you may need to re-pressurize during the micro-infusion. WARRANTY VOID WITH USE OF NON-ARBORJET APPROVED FORMULATIONS

8 Pressurize and Prime Supply Lines Pressure Blow-off (120 psi) 1.) Make sure F-Series 3 turn main bottle cap valve and ¼ turn Ball Valves are OFF before Pressurizing. 2.) Connect the Pressure Pump to the Pressure Quick Disconnect on the bottle top. 3.) Pressurize between 35 120 psi. For safety: Blow-off valve will release at 120psi (maximum). 4.) Turn ON the F-Series 3 turn main bottle cap valve and product will flow into the supply lines. 5.) To prime the supply lines, open each Needle Valve to release any air in the lines. Product will fill the supply lines. This is recommended for best uptake results. NOTE: Before you begin treating Conifers, please see pg 15 Conifers vs Deciduous

9 Select Arborplug Sites Sites are within 36 above the soil line. The Best Arborplug Injection Zone No. of Arborplugs = DBH /4 or DBH /3 (ex. 24 DBH = 6 8 sites) Root Flares show best uptake and formulation distribution to the canopy. Choosing good Arborplug sites result in faster injections.

10 Drill Sites for Arborplugs Use sharp, high-helix brad-point drill bits (included in kit). Annual Rings Inner Bark Bark DRILL BIT STEP 1 Use very light pressure to drill through outer bark and inner bark. The drill bit will stop at the Xylem. You can remove drill bit to note the bark thickness. 1 Xylem tissue Inner Bark Bark STEP 2 Use quick heavy pressure to drill into the Xylem. 2 5/8 2 DRILL BIT Estimated Drill Depth into Xylem: Hardwoods 5/8 1 5/8 deep Conifers 1 5/8 2 deep Drill Bit Sizes: 9/32 for #3 Arborplugs 3/8 for #4 Arborplugs

CORRECT INCORRECT Set the Arborplugs Too Deep Too Shallow 1. Set Arborplugs into drilled holes using set tool (from kit) and hammer. Xylem Tissue Inner Bark Bark Xylem Tissue Inner Bark Bark 2. Make sure the barbs on the Arborplug make a seal between the xylem and the inner bark as illustrated. Xylem Tissue Inner Bark Bark Xylem Infusion Tissue Legs Inner Bark Bark Barbs Barbs Barbs CORRECT

12 Micro-infusion with the FSeries 1 2 3 1. Turn bottle top valve ON (counterclockwise). 2. Set VIPER Needle into the Arborplug. 3. Turn VIPER Needle valve ON (counterclockwise). Repeat for each needle. 4. Turn OFF each VIPER Needle as it finishes, and remove. Caution!! Do not leave Arborjet F-Series unattended. Pesticide applications should always be attended and monitored.

13 Treating Multiple Trees with the FSeries When treating several trees in one area, multiple F-Series work very well. Set up your first F- Series then the second then the third. By then the first tree is complete. Remove the first F- Series and set it up on the next tree and continue to leap-frog the F-Series. This method is efficient. Fast uptake ring-porous trees may only need 2 F-Series to leapfrog. Conifers and some diffuse porous trees take longer to treat and may require more F-Series for maximum efficiency.

14 Large Tree Micro-infusion 400 ml is the maximum fill capacity for the smaller 650 ml bottle. If more than 400 ml is used, the FSeries requires RE-PRESSURIZING during Microinfusion. More than 1 FSeries can be used on the same tree. Examples: -If dose is 800 ml, put all in 1-1.5 liter bottle or 400mL in each of 2-650 ml FSeries bottles. -If dose is 1200mL, put 400mL in 3 FSeries bottles or 600mL in each of 2-1.5 liter bottles Hex PDS connects to bottle top Additional 4 line manifold(s) are connected

15 Procedure: Conifers vs. Deciduous Important Note For Conifer Injections: Sap flows out of conifers as a protective response to drilling. For best results, we recommend: 1. Pressurize F-Series and prime each supply line. 2. Drill and set 1 Arborplug 3. Insert 1 VIPER needle and turn on the SMC Valve. 4. Repeat steps 2 and 3 for each injection sites. Insert VIPER needle and turn on valves right after each Arborplug is set. If too much time has passed between Arborplug setting and micro-infusion, sap may flow into your injection site, and make your uptake slower. Important Note For Deciduous Injections: No sap flows from deciduous trees after drilling. For best results, we recommend: 1. Pressurize F-Series and prime each supply line. 2. Drill and Set All Arborplugs. 3. Insert All Primed VIPER needles and turn on each SMC Valve. 4. Turn All Primed VIPER needles ON (same time) Deciduous tree micro-infusion occurs very rapidly. You can open all VIPER needle valves then open the bottle top valve. This will ensure that even distribution of product occurs at each injection site.

16 Clean Out the FSeries Before Clean-out: Make sure all product is out of FSeries bottle and lines. CLEAN-jet is for rinsing formulation residues to keep your FSeries operating smoothly. 1. Remove bottle top to release pressure, then add 20-30mL CLEAN-jet 2. Apply FSeries bottle top and pressurize. 3. OPEN and close each Needle Valve to clean out all lines. CLEAN-jet rinse can be squirted in the soil at the base of the tree, unless near ground water or waterways. Rinse all CLEAN-jet out of the bottle, line, and device. *CLEAN-jet should not be mixed with other formulations. * Dispose of waste according to local and state regulations.

17 Maintenance: Deluxe Needle Valve Cartridge & PTC VIPER Molded Needle To Clean out any debris in VIPER Needles: 1. Remove VIPER Needle by pushing the PTC fitting in and pulling on the Needle. 2. Push the VIPER Needle Cleanout Tool into the VIPER Needle. 3. Remove in-line debris without VIPER needle attached. VIPER Needle Cleanout Tool Some PTC fittings have a 5/64 internal hex. Use Allen key to tighten, loosen, or remove a broken part.

18 Maintenance: Deluxe Needle Valve Cartridge & PTC Deluxe Needle Valve may need periodic cleaning or O-ring replacement. To restore on/off valve to like new operation, replace O-rings on deluxe valve cartridge Compression Fittings

19 Maintenance: Deluxe Needle Valve Cartridge & PTC The Plugless STINGER Method is only recommended for use in Faster Uptake Trees (including, but not limited to red and black oaks, elms, sycamore, poplar, birch, sweetgum, tulip poplar and flowering apple. The STINGER Method does not use Arborplugs, thus the injection may take longer. Drill bit = 7/32 1 2 3 4 1. Drill 1 into sapwood (bark depth + 1 ) at slight downward angle. 2. Pressurize F-Series. Make sure valves are OFF. 3. Turn each STINGER ON, and OFF to prime supply lines. 4. Turn each STINGER OFF when primed. 5 6 7 5. Push STINGER Tips into drilled holes until snug. 6. Turn the STINGER ON 7. Turn OFF valve after tubing has emptied of product. Then wait 10-15 seconds before removing STINGER needle from drill hole.

20 Bark Inner Bark Bark Inner Bark Bark Inner Bark Plugless VIPER Method for F-Series This is the recommended placement of the VIPER tips in the tree. Annual Rings Annual Rings Annual Rings VIPER Tip 7/32 VIPER Tip VIPER Tip Recommended Incorrect Incorrect Fast Product Uptake Slow Product Uptake Slow Product Uptake Possible Bark Separation or Leakage

21 F-Series Replacement Parts B A A. Pressure Relief Valve 2 pack (070-0220) B. Fill Cap w/ Washer (070-0230) F C. 120 PSI Blow-off Assembly (070-0225) F-Series Cap Assembly 070-0076 C E D. FS Internal Bottle Parts (070-0235) E. ¼ PTC 4-Pack (070-0100) F. FS Pressure Quick Disconnect Kit (070-0205) D

22 F-Series Replacement Parts A C E B FS Needle Ball Valve Assembly 2 pack 070-0094 D A. FS Ball Valve Assembly (070-0086) B. 1/8 Male x 10-32 Adapter (975-1124) C. PTC 10/32 to 1/4 Push 4-Pack (070-0100) D. VIPER Needle 4-Pack (070-0501) E. FS 90 degree swivel PTC 4 pack (070-0087) F. FS 1/8 NPT to 5/32 QD NC 2 pack (070-0088) F FS Hex PDS w/ Connectors (070-0080)

Item # Description Kit Components 070-0075 FS Single Tree I.V. F-Series Replacement Parts Cap Assy., 1.5L Bottle, 16 Stand, Hex PDS, (6) Valve Assy. w/ tubing 070-0078 FS Tree IV Bottle 1.5 Liter 1.5 Liter Bottle w/ cap and washer 070-0079 FS Tree IV Bottle.650 Liters.65 Liter Bottle w/ cap and washer 070-0085 FS Hex PDS Complete Hex PDS, ¼ Tubing, (6) 5/32 Tubing 070-0090 FS High Pressure Pump Pressure pump w/ adapter 070-0091 FS Expansion Kit Expansion adapter, ¼ Tubing 070-0092 ¼ HP Tubing 5 feet ¼ Tubing 070-0093 5/32 HP Tubing 10 feet 5/32 Tubing 070-0104 Mixing & Measuring Kit Funnel, Graduated Cylinder, Mixing Container 070-0120 Arborplug Setter 2-Pack 2 Pack 070-0130 VIPER Needle Clean-out Tool 2-Pack 2 Pack 070-0210 F-Series Stand 4-Pack 16 Wire Stands (4 per package) 070-0215 F-Series 6 Gallon Bucket Black 6 Gallon Bucket 070-0240 FS Tree I.V. Tool Kit Adj. Wrench, Plug setter, cleanout tool 2pk, 3/8 bit, 9/32 bit, 5/64 allen wrench, 3/16 allen wrench 070-0655 FS O-Ring Rebuild Kit (1) Med Bottle Washer, (1) Re-fill Cap Washer, (1) #6 O-Ring, (1) #8 O-Ring, (2) #12 O-Ring 070-0660 Deluxe Drill Bit Kit (2 Bits) (1) 3/8 Drill Bit, (1) 9/32 Drill Bit 070-0665 Deluxe Drill Bit 3/8 #4 2 pack (2) 3/8 Deluxe Drill Bit 070-0670 Deluxe Drill Bit 9/32 #3 2pack (2) 9/32 Deluxe Drill Bit

F-12 O-Ring Kit (Comes in Kit) Med Bottle Washer Re-fill Cap gasket (Flat end facing away) #12 O-Ring #6 O-Ring For replacement parts, order: F-Series O-Ring Rebuild Kit (070-0655) (1) Med Bottle Washer (1) Re-fill cap gasket (2) #12 O-Ring (1) #6 O-Ring (1) #8 O-Ring NOTE: The O-Ring rebuild kit will rebuild one F-Series unit. #8 O-Ring