ECE/TRANS/WP.29/GRSG/2017/29)

Similar documents
East Building, PHH-30 U.S. Department New Jersey Avenue S.E. of Transportation Washington, D.C DOT-SP (FOURTH REVISION)

Rationale for the proposed amendments to Regulation No. 110 (Specific components for CNG) Submitted by the expert from ISO (TC 58/SC 3)

EXPIRATION DATE: (FOR RENEWAL, SEE 49 CFR ) 1. GRANTEE: Structural Composites Industries (SCI) Pomona, CA

Transport of gas tanks for motor vehicles

ST/SG/AC.10/C.3/2016/8. Secretariat. United Nations. Transport of gas tanks for motor vehicles. Introduction

INF.27. Economic Commission for Europe Inland Transport Committee. Pressure receptacles for paintball guns. Introduction

Pressure Equipment Directive PED 2014/68/EU Commission's Working Group "Pressure"

Transport of gas tanks for motor vehicles

This document is a preview generated by EVS

EXPIRATION DATE: March 31, GRANTEE: Hexagon Ragasco AS Raufoss, Norway (U.S. Agent: Hexagon Ragasco North America Inc.

East Building, PHH-30 U.S. Department New Jersey Avenue S.E. of Transportation Washington, D.C EXPIRATION DATE: June 30, 2015

Other Si min/max. Cr min/max. 0.4/ / / / Bal.

Informal document regarding progress of CEN standards for reference in RID/ADR

INTERPRETATION OF THE REGULATIONS/STANDARDS...

Smart Water Application Technologies (SWAT) TM

Rationale for the proposed amendments to Regulation No. 110 (CNG/LNG vehicles) (Based on Informal Document GRSG Rev.1)

East Building, PHH-30 U.S. Department New Jersey Avenue S.E. of Transportation Washington, D.C DOT-SP (ELEVENTH REVISION)

Economic and Social Council

Economic and Social Council

Annex 4A: paragraph 4

DESCRIPTION OF THE PRESSURE TEST METHODS USED DURING CYLINDER MANUFACTURE

Kiefner & Associates, Inc.

[Reserved] Packagings ICC 3 1 3AA 3AL 3AX 3A480X 3AAX

East Building, PHH-30 U.S. Department New Jersey Avenue S.E. of Transportation Washington, D.C DOT-SP (NINTH REVISION)

NKS PODRIS project. Importance of inspection reliability assumptions on piping failure probability estimates

DOT-SP 8391 (FIFTHTEENTH REVISION) EXPIRATION DATE: (FOR RENEWAL, SEE 49 CFR )

EXPIRATION DATE: January 31, 2015

TEST REPORT N

PRODUCT SPECIFICATION. SFP+ Cage and Cage Assembly 1 of 8 A

East Building, PHH-30 U.S. Department New Jersey Avenue S.E. of Transportation Washington, D.C DOT-SP 8718 (SEVENTEENTH REVISION)

PNEUMATIC STOPPERS OPERATING MANUAL. Type F G H - FOG

East Building, PHH-30 U.S. Department New Jersey Avenue S.E. of Transportation Washington, D.C DOT-SP 7218 (NINETEENTH REVISION)

BASIC REQUIREMENTS FOR FIBER REINFORCED PLASTIC (FRP) TYPE 3FC COMPOSITE CYLINDERS

TECHNICAL SPECIFICATION

Minimum test pressure (psig) 2. Requalification period (years) DOT psig 5. non-corrosive service ( see

International Civil Aviation Organization DANGEROUS GOODS PANEL (DGP) MEETING OF THE WORKING GROUP OF THE WHOLE. Montreal, 18 to 22 April 2005

Application of pipeline risk assessment to proposed developments in the vicinity of high pressure Natural Gas pipelines

SPECIFICATIONS - DETAILED PROVISIONS Section Butterfly Valves C O N T E N T S

Submitted by the International Organization for Standardisation (ISO) 1

We agree the CGA publication more adequately reflects the equipment accuracy requirements for performing a pressure test on cylinders.

Information on work in progress in CEN

Commercial Practice Test Method Internal Vapor Analysis of Hermetic Devices

TECH TIPS: ROPE DEFECTS

IGEM/TD/2 Edition 2 with amendments July 2015 Communication 1779 Assessing the risks from high pressure Natural Gas pipelines

Department of Transportation

ATHLETE NOMINATION CRITERIA 2018 COMMONWEALTH GAMES TEAM

Regulations of the International Young Naturalists Tournament

Economic and Social Council

REVISED SOLAS REGULATION II-1/3-8 AND ASSOCIATED GUIDELINES (MSC.1/CIRC.1175) AND NEW GUIDELINES FOR SAFE MOORING OPERATIONS FOR ALL SHIPS

Economic and Social Council

TG GUIDELINES CONCERNING CALIBRATION INTERVALS AND RECALIBRATION

(DD/MMM/YYYY): 10/01/2013 IP

400 Seventh Street, S.W. of Transportation Washington, D.C EXPIRATION DATE: February 28, 2010

Flock Theory, Applied (To Scrum)

NEW IGC CODE AND IGF CODE

Accreditation for In-Service Inspection of Transportable Pressure Receptacles (TPRs)

Proposal for amendment to Regulation No

Economic and Social Council

East Building, PHH-30 U.S. Department New Jersey Avenue S.E. of Transportation Washington, D.C DOT-SP (EIGHTEENTH REVISION)

PUBLISHED PROJECT REPORT PPR850. Optimisation of water flow depth for SCRIM. S Brittain, P Sanders and H Viner

5.0 INSPECTING, FILLING AND LABELING SMALL CYLINDERS

Knowing the Job: Any employee actively engaged in dispensing propane should meet minimum responsibilities

EXPIRATION DATE: June 30, 2011

EXPIRATION DATE: September 30, 2013

Design Qualification. DQ Regulatory Requirements EU-GMP, Annex 15

Live working in Italy

NASA AEROSPACE PRESSURE VESSEL SAFETY STANDARD

LEVEL 2 CERTIFICATE OF COMPETENCE IN THE SAFE USE OF MOWERS ASSESSMENT SCHEDULE

HEALTH AND SAFETY EXECUTIVE HM NUCLEAR INSTALLATIONS INSPECTORATE

Safety assessments for Aerodromes (Chapter 3 of the PANS-Aerodromes, 1 st ed)

Draft Regulation on Driver Assist Systems to Avoid Blind Spot Accidents Proposal for Regulation Text

RULES PUBLICATION NO. 52/P UNDERWATER INSPECTION OF MOBILE OFFSHORE DRILLING UNITS IN LIEU OF DRYDOCKING

IACS History File + TB

DOCUMENT DESPATCH ADVICE Ref: MED 16 :3/T-45 Date:

The following comments are respectfully submitted by Darrell Garton, Vice President of Galiso Inc.

CHAPTER 1 General Part

12/22/ CHG 124 VOLUME 3 GENERAL TECHNICAL ADMINISTRATION

Installation Instructions and valve Maintenance Rev. 0 of 21/09/15

MECHANICAL REDESIGN OF ION EXCHANGE RESIN VESSEL BOTTOMS AT HULETT REFINERY

European Rowing Championships Constitution and Rules. Constitution

Pressure Equipment Directive PED 2014/68/EU Commission's Working Group "Pressure"

RESOLUTION MSC.321(89) (adopted on 20 May 2011) ADOPTION OF AMENDMENTS TO THE REVISED RECOMMENDATION ON TESTING OF LIFE-SAVING APPLIANCES (RESOLUTION

REGULATIONS 1. GENERAL CONDITIONS

AMENDMENTS TO THE IMSBC CODE AND SUPPLEMENTS

ACCREDITATION OF ON-LINE LEAK SEAL ORGANIZATIONS

II. Table C, column 20, additional requirement number 12 for UN 1280 and UN 2983: Table C column 20 mentions additional requirement/remark #12:

Government of Bermuda Department of Maritime Administration BERMUDA SHIPPING NOTICE

23 RD INTERNATIONAL SYMPOSIUM ON BALLISTICS TARRAGONA, SPAIN APRIL 2007

Annex 1 to Decision 2009/007/R

STANDARD SPECIFICATION FOR SPLIT TEES (HOT TAP MATERIAL)

ISO/TR TECHNICAL REPORT. Natural gas Calibration of chilled mirror type instruments for hydrocarbon dewpoint (liquid formation)

Technical Standard Order

Article. By: Capt. Himadri Lahiry; Prof. Reza Ziarati

BRITISH TRIATHLON FEDERATION 2018 ELITE AQUATHLON TEAM SELECTION POLICIES

RESOLUTION A.761(18) adopted on 4 November 1993 RECOMMENDATION ON CONDITIONS FOR THE APPROVAL OF SERVICING STATIONS FOR INFLATABLE LIFERAFTS

E/ECE/324/Rev.2/Add.133 E/ECE/TRANS/505/Rev.2/Add.133

STRUCTURAL INTEGRITY EVALUATION OF CNG COMPOSITE CYLINDERS BY ACOUSTIC EMISSION MONITORING

APPENDIX B TESTING PROTOCOLS. Method A: Straight Test Method B: Angular Deflection Test. Method C: Shear Load Test

INTERNATIONAL SKATING UNION

Organisation Internationale de Métrologie Légale

Transcription:

Submitted by the expert from Italy Informal document GRSG-114-07 (114th GRSG, 9 13 April 2018, Agenda item 6(b)) Additional elements to support the Italian proposal to amend Regulation No. 110 (document ECE/TRANS/WP.29/GRSG/2017/29) on the basis of the results of the Italian research on type CNG4 cylinders The Italian proposal to amend Regulation No. 110 (CNG/LNG vehicles) refers to CNG4 cylinders and is articulated in 4 different points which address two completely different concerns: while point 1 refers to the visual inspection of CNG4 cylinders for periodic requalification, points 2,3 and 4 refer to the minimum safety level to impact damage which should be assured to CNG4 cylinders according to the Regulation. The research performed in Italy is related to the second subject (points 2,3,4 of the proposal). It should be noted that points 2 and 3 are only an obvious and necessary corrigendum to UN Regulation No. 110 (R110): all tests for cylinder design qualification listed in Tab. 6.4 are described in detail, for each cylinder type, in paragraphs, 7.5 / 8.6 / 9.6 / 10.7. In paragraph 10.7 (CNG4 cylinders) the drop test, required in Tab. 6.4, is missing, which is an evident error and lack of information. Then the only point under discussion should have been the need of providing a univocal interpretation to paragraph A20, in appendix A of Annex 3A (we ask to make clear that the safety level required for impact damage should be reached by the cylinder itself, not by glued dome cover protections). The research started following 3 in-service failures of CNG4 cylinders, with glued dome protective covers, which have been ascribed to impact damage. To verify the impact damage safety level of this kind of construction, 24 CNG4 cylinders with glued dome covers have been impact damage tested according to the cited paragraph A20. The results have shown: - that the considered cylinders (with glued dome covers) have a weakest point in a zone of the dome where the thickness is about one half of the cylindrical part (as in the case of the in- service failures); - that the tested CNG4 cylinders are able to reach the required level of safety against impact damage only for the presence of the dome covers; - that such a cylinder, after a change of design, could be approved without reaching the required safety levels, not even with the dome covers on (10 on 12 tested

CNG4 cylinders of new production failed during the hydraulic test or the fatigue test performed after impact damage); - that the analysed CNG4 cylinders seem to have the tendency to show dome cover failures without any impact damage or even without being used before (see enclosed photos). Paragraph A20 states quite clearly that the required minimum safety level to impact damage should be fulfilled by the finished cylinder. Paragraph 4.56 of R110 clarifies that finished cylinders are Completed cylinders which are ready for use but free from non integral insulation or protection. The failures occurred in service in Italy and the results of the Italian research seem to indicate that, in some practical applications, the meaning of integral protection has been extended to glued dome covers. On the basis of what has been above resumed, the interpretation that the safety levels required by paragraph A20 could be fulfilled not by the cylinder itself, but also with the help of dome covers, appears to be wrong and very dangerous (as the in service failures have shown). Therefore, the amendments proposed to points 2,3 and 4 of the Italian proposal are justified for the following reasons: - points 2 and 3 are a simple corrigendum to the description of the design qualification tests needed for CNG4 cylinders; - paragraph A20 prescribes that the test should be performed on the finished cylinder ; - paragraph 4.56 clarifies that finished cylinders are Completed cylinders which are ready for use but free from non integral insulation or protection ; - it seems very unlikely that glued dome covers (as the ones of the tested cylinders), for their geometry and constitution, could be assumed to be an integral protection (see enclosed photos); - R110 gives very precise rules for the material, design and testing of all structural components, but does not consider dome covers, as it should have done if they could be used to fulfil a structural requirement. Table 6.7 (change of design) requires the drop test (and the related safety level) only for changes related to the fibers or to the resin, not to the material or the design of the dome cover; - the possibility of reducing the thickness of the dome as much as it has been evidenced in the analysed cylinders, is theoretically justified only for the load due to the internal 2

pressure in cylinders made of an homogeneous material. It follows that this reduction is not correct, in general for impact loading, but, above all, not even for internal pressure loading, in the case of CNG4 cylinders: due to the more complex geometry of the dome, it is reasonable to assume that the chance to have some production defects is higher in the domes that in the cylindrical part. It is then reasonable also to admit that small defects not revealed by the hydraulic test, will have a higher negative influence on the service life of the CNG4 cylinder if the thickness and the strength of the dome, on the basis of theoretical assumptions and of an unlikely interpretation of the damage safety requirements of R110, are reduced too much; - it is necessary to avoid the possibility to have on the market R110 designed and approved CNG4 cylinders which are not able to give the required levels of safety to impact damage which, according to R110, should be guaranteed. Coming to the amendment related to the visual inspection for periodic requalification (point 1 of the Italian proposal), it should be noted that paragraph 4.1.4 of Annex 3A states that Each cylinder shall be visually inspected including under the support straps. As far as we know, this prescription has not yet been amended and then it is still compulsory for R110 approved cylinders. In our opinion disregarding this requirement could be very dangerous, especially for composite cylinders. Indeed it seems very unlikely that someone could dare to say that there is no danger of wear-damage on the surface under the straps for a composite cylinder; this is particularly true after several years of vehicle operation on dusty or sandy roads. Moreover, Annex 3A, point 6.12, of R110, dealing with exterior environmental protections, specifies that The coating shall be designed to facilitate subsequent in service inspections. It seems very unlikely that someone could dare to say that this requirement is not to be extended to any kind of protection not explicitly considered in the Regulation. Then it seems that the Italian request to amend point 4.1.4 (specifying that, for periodic requalification, the absence of damage shall be verified also under any kind of non integral protection, like the glued dome covers) is quite important and necessary to avoid dangerous misinterpretations of what this Regulation requires to be accomplished at each Periodic Requalification. 3

TECHNICAL DATA IN SERVICE FAILURES OF CNG4 CYLINDERS: in Italy there have been 3 in service failures of CNG4 cylinders with glued dome covers (a 12.5 l cylinder during the first refilling after the installation of a new kit of cylinders; a 39 l cylinder during refilling after about one and a half year and 60 000 Km from the registration of the car; one 11.4 l during the hydraulic test performed for the periodic requalification). The failure was always on the valve-dome, in a zone where the thickness of the composite wall was very low, about one half of the one in the cylindrical zone). Although there was absolutely no evidence of a prior car collision or of any impact damage, the failures have been always attributed to impact damage. Only the Working Group nominated by the Italian Transportation Ministry evidenced that the cause could also have been a non - conformity of production in the zone of the explosion, which appeared to be the weakest link for the safety of the cylinder (not only for impact damage but also for non conformities of production). ITALIAN RESEARCH ABOUT CNG4 FULFILLMENT OF R110 REQUIREMENTS FOR SAFETY AGAINST IMPACT DAMAGE 24 cylinders with glued dome covers (11.4 l and 12.5 l, which is an extension of approval of the 11.4 l) have been tested against impact damage according to point A20 of R110 (Appendix A of Annex 3A) for CGFBM at RINA Consulting Centro Sviluppo Materiali in Castel Romano Roma. While all the 12 cylinders of 11.4 l fulfilled what required at paragraph A20, 10 over 12 cylinders of 12.5 l failed during the hydraulic test or the fatigue test performed after the drop test The cylinders that successfully passed the test with dome covers on, where tested again without dome covers and failed, all but one. In all cases (with and without dome covers) the failures took place in the same zone of the dome, where the thickness is about one half of that in the cylindrical zone. The less damaging drop test resulted to be the one with the cylinder in a vertical position. It should be pointed out that 6 of the 12.5 l cylinders evidenced cracks on one of the dome covers, as shown in the enclosed photos, while still in the packing case, before any kind of usage. 4

5