The Tekran Series 2600-IVS Difference!

Similar documents
Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs.

Versatility. Accuracy. Compact. Versa. Automated Headspace Vial Sampler

Title: Standard Operating Procedure for Measurement of Ethylene (C 2 H 4 ) in Ambient Air by Reduced Gas Detection (RGD)

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

HumiSys HF High Flow RH Generator

UNITY 2 TM. Air Server Series 2 Operators Manual. Version 1.0. February 2008

ONH836 Series: Oxygen/Nitrogen/Hydrogen by Inert Gas Fusion

Thermo Scientific Model 146i Principle of Operation

Mass Spec will not Autotune

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment Varian 310

Your local gas generation partner. Precision series Modular gas generation solution for GC.

Title: Standard Operating Procedure for Dasibi Model 5008 Gas Dilution Calibrator

MMS Mercury Monitoring System for Natural Gas

Title: Standard Operating Procedure for Sabio 2010 and 4010 Dilution Calibrator

Columbus Instruments

Automated Determination of Dissolved Gases in Water Anne Jurek. Abstract: Discussion:

PRC CO ² -LASER PRESENTATION

The instrument should have a mass range from 2 to 2000 m/z or better Interface

Setting a New Standard in Flash Chromatography Performance

Toxicology Gas Chromatography-Mass Spectrometry (GC-MS)

Title: Standard Operating Procedure for R&R Environmental Devices Model MFC201 Gas Dilution Calibrator

Title: Standard Operating Procedure for Elemental and Organic Carbon (EC and OC) using Non-Dispersive Infrared Detection (NDIR)

ANALYTICAL SCALE HPLC AGILENT SYSTEMS OPERATIONAL QUALIFICATION

Agilent 7800 ICP-MS. Specifications and Typical Performance. Fast track metals analysis with Solution-Ready ICP-MS

GCMSD-Headspace Analysis SOP

ON736 Series: Oxygen/Nitrogen by Inert Gas Fusion

Detector Carrier Gas Comments Detector anode purge or reference gas. Electron Capture Nitrogen Maximum sensitivity Nitrogen Argon/Methane

DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES

The instrument will process the samples one by one till all the samples have been cleaned up.

Superior Result from Analytical Instruments The constant purity of the nitrogen improves system stability and ensures reproducible results

Ghost Peaks: How to Fix a Haunting Problem. Jacob A. Rebholz Teledyne Tekmar VOC Product Line Manager

APPLICATION NOTE. GC Integrated Permeation Device

no peaks missing peaks too small peaks increasing retention decreasing retention

Degassing ERC KK Saitama, Japan

FTIR Users Group Meeting FTIR development

FLUORESCENCE DETERMINATION OF OXYGEN

OMCL Network of the Council of Europe QUALITY ASSURANCE DOCUMENT

AKTA pure 25 New Owner s Intro

ACV-10 Automatic Control Valve

Gases&Technology. Measurement of Impurities in Helium Using the Dielectric Barrier Discharge Helium Ionization Detector. FEATURE.

INSTRUMENT INSTRUMENT YL INSTRUMENT

Zebron Gas Management

Pneumatic high-pressure controller Model CPC7000

Best Practice for Identifying Leaks in GC and GC/MS Systems

Application Note. ASTRON Remote Plasma Source Ignition Best Practices PROBLEM

UT 3000 Mercury Ultratracer

Three Columns Gas Chromatograph Analysis Using Correlation between Component's Molecular Weight and Its Response Factor

Best Practice Guide, Servomex 2700

The HumiPyc - Model 1 - Gas Pycnometer; Density, Moisture, Permeation Analyzer; RH sensor Calibrator

Navigator 600 Silica analyzers

Autocalibration Systems For In Situ Oxygen Analyzers

Automated Determination of Dissolved Gases in Water Anne Jurek

Application Note AN-107

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

Your local gas generation partner. Precision series Modular gas generation solution for GC.

800 Series Mass Flow Meters and Controllers. High Performance Mass Flow Meters and Controllers

DETERMINATION OF TETRAHYDROTHIOPHENE IN AMBIENT AIR BY GAS CHROMATOGRAPHY WITH A PFPD DETECTOR COUPLED TO A PRECONCENTRATION TECHNOLOGY

EAS Basic Soil Gas Sampler

Constant Pressure Inlet (CCN) Operator Manual

Technical Specifications of Hydrogen Isotope Handling and Recovery System

APPLICATION NOTE. Fast Analysis of Coal Mine Gas Using the INFICON 3000 Micro GC ABSTRACT

Design. Pompetravaini-NSB API SB Liquid Ring Compressor for Gas Processing. Working Principle

Your local gas generation partner. Precision series Modular gas generation solution for GC.

Increasing the productivity of ICP-OES with the Thermo Scientific Qtegra ISDS Software

Gas Clean. Filters. Delivering Clean Gases for GC and GC/MS Operation

METHOD 3C - DETERMINATION OF CARBON DIOXIDE, METHANE, NITROGEN, AND OXYGEN FROM STATIONARY SOURCES

The HumiPyc ( Model 2) - Gas Pycnometer; Density, Moisture, Permeation Analyzer; Filter Integrity Tester; RH sensor Calibrator

ACCURATE PRESSURE MEASUREMENT FOR STEAM TURBINE PERFORMANCE TESTING

X-Flow Mass Flow Controller 授权代理 : 北京品超思瑞科技学院公司

Leaks, contamination and closed loop control how RGAs make coating processes more profitable

S-CO 2 Brayton Recompression Loop Design and Control

Retention Time Locking: Concepts and Applications. Application

DEBUBBLERS & DEGASSERS ACTIVE DEBUBBLERS APPLICATION NOTE WHY DEGAS YOUR MOBILE PHASE? PAGE 177 STAND ALONE DEGASSERS PAGE 175 PAGE 178

Mass Flow Controller (MFC) for Gases

Supplementary Operator s Manual 42/24-14 EN Rev. 3

A New GC/MS System Designed for Helium Carrier Gas Conservation

Thermal Mass Flow Controllers for High Accuracy Process Gas Applications

3-Way Decoking Valve Option - Installation and Operation Instructions Accessory G Background

Overview. Front Panel: Keypad and Display

Customer Responsibilities. Important Customer Information. Agilent 6400 Series Triple Quad LC/MS Site Preparation Checklist

3 Flow and Pressure Control

An Overview of Types of Isolation Valves

Environmental Petrochemical, Pharmaceutical, Foods & Flavors, Chemicals, Personal Care, Forensics,...and more!

AC : MEASUREMENT OF HYDROGEN IN HELIUM FLOW

Bante820 Portable Dissolved Oxygen Meter Instruction Manual

Generating Calibration Gas Standards

Automatic Isokinetic Sampler. ST5 Evo

Features. Main Voltage: Vdc. Input Control Signal: 0-5 Vdc or 4-20 madc (Sourcing) Monitor Output Voltage: 0-5 Vdc or 4-20 madc (Sourcing)

THERMAL MASS FLOW MEASUREMENT FOR GASES

Drilling Efficiency Utilizing Coriolis Flow Technology

Air Quality 2b - PFGC/FID Analysis of Benzene and Toluene in Automobile Emissions

High Pressure Asher HPA-S

Level, Pressure, and Density Instrumentation for the Petrochemical Industry

BEST KNOWN METHODS. Transpector XPR3 Gas Analysis System. 1 of 6 DESCRIPTION XPR3 APPLICATIONS PHYSICAL INSTALLATION

CORI-FLOW PRECISION MASS FLOW METER / CONTROLLER FOR LIQUIDS AND GASES

Using the UltraRAE. Firmware 2.35

Gases and welding distributors continue

FROG-4000 TM Chemical Analysis System

O2100C Oxygen Measurement Module Technical Use Notes do not use other wall adapters with the O2100Cmodule. 10% / V 5% / V 2% / V 1% / V 10% / V

Transcription:

Tel:+1-416-449-3084 Fax: +1-416-449-9298 The Tekran Series 2600-IVS Difference! Rev 021916 Method 1631 (Dual Gold Trap CVAFS) Method 245.7 (Direct CVAFS Analysis) US EPA IO-5 (Ambient Air) ASTM D-6350 (Natural Gas) Tekran equipment is manufactured under US and foreign patents and patents pending The Tekran Series 2600-IVS is the most stable, sensitive ultra-trace mercury analyzer available today. It was designed to be easy to set up, easy to use, and easy to maintain. The Series 2600-IVS CVAFS Mercury Analysis System has a number of unique features that increase its performance and flexibility. The standard system is equipped with the same detector as is used in our Model 2500. The Model 2500 Atomic Fluorescence Detector is renowned for its sensitivity, low noise and stability. Superior design with unsurpassed analytical performance Short set up time Robust & simple to maintain Superior user control Adaptable to multiple methods Minimal sample carryover with auto-flush function Automatic shut off Free factory training and lifetime customer support WHERE MEASUREMENT BEGINS Page 1 of 5 Order & technical support:

Tel:+1-416-449-3084 Fax: +1-416-449-9298 General Features Before Delivery Before shipment, every Series 2600-IVS system is exercised for several days in our labs. Each and every unit is fully tested to demonstrate an MDL of < 0.05 ng/l before being shipped. This is a factor of four lower than EPA requirements. Others may claim a low MDL. Tekran actually delivers day after day. In clean room environments with low mercury blanks, MDL s as low as 0.02 ng/l are routinely achievable. We have a Pre-Delivery Guide, to help you prepare your lab before the system arrives. We provide lists of preferred, low mercury reagent suppliers to minimize start up time. Easy to Set Up The Series 2600-IVS assembles for operation in only minutes. A step by step Quick Start Guide will have you up and running in no time. Unlimited free telephone support is available in the event you require assistance. (Toll free in the US and Canada) Ongoing Assistance Tekran is here to assist you every step of the way. For instance, once you are up and running, you may find that your blanks are too high. Tekran s various Method Analytical Guides and our phone support will assist you with these and any other analytical issues you may encounter. Free Factory Training Courses Tekran provides periodic factory training courses for customers. These courses are provided at no charge and provide comprehensive information on how to actually run low level samples in your laboratory. They detail methods to reduce background levels and cross contamination as well as demonstrating instrument maintenance and basic repair operations. On-site training can also be arranged for a nominal fee. Customers with previous trace metals analytical experience generally do not require these courses. Simple to Maintain / Low Cost of Ownership Tekran equipment is routinely used in some of the most remote, inhospitable places on earth. For example, researchers have used the Series 2600-IVS in the high Arctic to perform snow sample analysis. These scientists are often capturing unique events that occur for only a few days per year; so reliability is of prime importance. Downtime and service calls are simply not an option. All Tekran products are designed to be easily serviceable by the analyst. Keeping a few spare parts on hand will reduce your downtime to virtually zero. All flow path components (tubing, cartridges, heaters, traps, Teflon lines, etc.) are user replaceable without tools. All main service components are placed on the top deck platform for easy access. A simple lift of the lid provides full access to these components. Infrequent operations such as lamp changes are easily performed with built in instructions in the operation software. WHERE MEASUREMENT BEGINS Page 2 of 5 Order & technical support:

Analytical Features 330 Nantucket Boulevard, Toronto, Canada M1P 2P4 Tel:+1-416-449-3084 Fax: +1-416-449-9298 Reliability doesn t count for much if the analyzer gives you the wrong answer! The Series 2600- IVS has design refinements and elements that give it unsurpassed analytical performance. Some of these may seem obvious, but no other system incorporates all of these features. Long Term Stability standards and 5 ppt (OPR) standards. 3 3 All samples prepared in 0.5% BrCl. Long Term Stability 2 The Series 2600-IVS is stable and holds its 1 calibration. The graph at right shows repeated runs of low level standard (1 ppt) and Ongoing Precision 0 and Recovery (OPR) standards run over a 16 hour Elapsed Time (hours) period. This long term stability means increased productivity with fewer reruns. Long term, continuous operation is expected and delivered. Concentration [ppt] 8 7 6 5 4 Notes: 1 Method 1631 dual stage amalgamation. 2 Test ran full reagent blanks, 1 ppt Elapsed Time: 15 hours 1 ppt 5 ppt Blanks Summary: Mean RSD 1 ppt 1.02 ppt 2.7% 5 ppt 5.10 ppt 1.7% 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Superior AF Detector The AF detector in the Series 2600-IVS provides extraordinary sensitivity, stability and selectivity. The graph at right shows a typical 0.5 ppt peak. Note the smooth profile and very low baseline noise. A high resolution (24-bit) A/D converter allows accurate quantitation of peaks ranging from less than 0.1 mv to over 1300 mv in height. Can manually drag handles to reintegrate peak if desired. Actual peak from a 0.5 ng/l standard. Note the excellent signal to noise ratio. The detector achieves this performance by having a number of unique features. The lamp is temperature controlled. An optical feedback arrangement ensures constant lamp intensity over the course of the run and from day to day. The entire optical path is purged with argon. (Air in the optical path will cause sensitivity and baseline shifts since ozone, ozone precursors, or other UV absorbing compounds may be present.) The detector uses a high sensitivity photomultiplier, rather than a cheaper photodiode UV sensor. Direct In-Vial Sparging (IVS) The Series 2600-IVS is designed to use direct sparging of mercury from the sample vials using a custom septum piercing probe. With direct sparging, the need for a separate gas/liquid separator is completely eliminated. Also eliminated is the need for a pumping system to move liquids though the system. The overall design is greatly simplified with fewer moving parts and simplification of sample introduction. This reduction in components translates to lower instrumentation cost, as well as reduction is operation cost. The absence of liquid transport greatly improves performance and extends the life of downstream elements. For Method 1631 (gold pre-concentration), it means that the lifetime of the first stage gold cartridge is substantially extended due to the absence of aerosols. WHERE MEASUREMENT BEGINS Page 3 of 5 Order & technical support:

Tel:+1-416-449-3084 Fax: +1-416-449-9298 Mass flow Controller A constant carrier gas flow is vital to long term stability of the analyzer. The Series 2600-IVS incorporates a mass flow controller (MFC) to ensure constant, repeatable analytical flow. (A mass flow controller consists of a thermal flow sensor, proportional valve, and closed loop feedback control circuit to ensure that the actual gas flow is always the same as the setpoint flow.) Tekran s MFC flow system is far superior to the flow restrictors or rotometers used in other analyzers. Flow Path The Series 2600-IVS uses only gas phase flow switching. Some other analyzers use valves to switch between the sample and wash water liquid streams. This is an ongoing source of difficulties, especially when running unfiltered samples. Switching the liquid phase with a valve can cause the following problems: Contamination High carryover Scarring of the valve seat, causing leaks Scavenging of mercury Except when actually loading the first stage cartridge with mercury, the Series 2600-IVS vents gas from the phase separator to the outside air rather than simply passing it downstream. This keeps the analytical system clean, ensuring trouble free operation for extended periods. Simple Mercury Speciation Some customers are using the Series 2600-IVS to perform fractionation of biological samples (e.g. fish and hair) into mercury species. By altering the reagents and on-line reduction chemistry, the Series 2600-IVS can be configured to measure either total mercury or inorganic mercury fractions. Organic mercury (methyl) is determined by difference. A simple, common digestion procedure is used prior to running both fractions. This approach is useful for certain matrices and avoids the lengthy and complex distillation, ethylation and GC separation required for low-level methyl mercury analysis. Recording and Logging of Internal Instrument States The Series 2600-IVS records a number of internal instrument variables and stores these results for each analytical run. Some of the parameters measured are: Lamp intensity Lamp drive voltage Pump speed Pump current Actual carrier gas flow This information provides a permanent record of the instrument parameters most vital to performance. It greatly simplifies troubleshooting and provides advance notice of potential problems. WHERE MEASUREMENT BEGINS Page 4 of 5 Order & technical support:

Tel:+1-416-449-3084 Fax: +1-416-449-9298 Sample Carryover and Auto-Flush Function The Series 2600-IVS has been designed with a number of features to minimize sample carryover. If you encounter an unexpectedly high sample that could result in carryover, the system Auto-Flush Function will automatically suspend sample analysis, perform exactly as many cleaning/flushing cycles as needed to eliminate residual contamination, and then resume processing your batch. This Auto-Flush Function is highly desirable because running a high concentration sample will immediately contaminate any analyzer s inlet pathways, especially if there is any liquid contact in the sample train (which the Series 2600-IVS avoids). Contamination from previous samples affects subsequent measurements and the flushing function reduces carry over potential. To further reduce contamination between samples, a Rinse tube containing an acid rinsing solution may be specified to run automatically after each sample. This feature does not increase the analytical time per sample and dedicating only one tube per rack of 12 samples provides sufficient solution for rinsing. This rinse step is in addition to the normal rinse function. Automatic Shutoff The analyzer will automatically purge itself and shut off all gases and reagent use after the final sample is run. Unattended operation is safe and routine. Tekran 2621M Auto Sampler Interfacing with the Series 2600-IVS is the state of the art Tekran 2621M auto sampler. The 2621M features a dedicated rack for standards, and a small footprint, and an optional integrated wash station. The unit can hold a maximum of 120 samples at a time, with the ability to run a combination of up to three fold down trays, each containing twenty-four 40 ml septa vials. Flexibility Even if you plan on running only compliance wastewater samples initially, you will appreciate the flexibility of the Series 2600-IVS. The analytical carrier gas flow, pump speed, valve configuration and heater temperatures are all set in user configurable event tables. Users can create and edit as many of these analytical cycle tables as desired. Opto-isolated event trigger outputs allow control of external equipment. For example, some customers connect the detector cell output of the Series 2600-IVS to a mass spectrometer, allowing isotopic abundances of their trace samples to be measured. Moreover, the top-deck method design of the Series 2600-IVS allows easy switching of analytical methods in a couple of minutes. The Series 2600-IVS is easily converted to carry out analysis water samples by EPA Method 245.7. Additionally, manually collected air samples may be analyzed via EPA method IO-5, manually collected natural gas samples may be analyzed via ASTM method D-5459-98 and ISO method 6978. Due to continuing development, all specifications are subject to change. WHERE MEASUREMENT BEGINS Page 5 of 5 Order & technical support: