OXY 3690 MP. Measuring transducer for air oxygen

Similar documents
T02.0.3X.6C-06 Page 1 of 6. Operating Manual for Dissolved Oxygen-Measuring transducer OXY 3610 MP

Please read these instructions carefully before use! Please consider the safety instructions! Please keep for future reference!

QPL... Pressure Switches. Siemens Building Technologies HVAC Products

Operating Instructions Temperature Measuring System MF420-5T-100

Solenoid gas valve. The solenoid gas valve is also applicable as a main gas valve Pilot gas valve for forced draft burners

Transmitter CS 21 Operation Manual

Technical Data Sheet MF010-O-LC

Gas density monitor With integrated transmitter Model GDM-100-TI

MANUAL KPS Pressure Control Valve

Transmitter CS 21 Operation Manual

Precision pressure sensor Basic version Model CPT6020

DTG - LCD Digital Temperature Gauge USER MANUAL

Instruction Manual Differential Pressure Transmitter

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

Instruction and Maintenance Manual

LK-SX CO 2 +VOC. Application. Security Advice Caution. Notes on Disposal

MASS-STREAM TM Instruction Manual. D-6200 Analog Mass Flow Meters / Controllers

Model PDT Dewpoint Transmitter

LK-SX VOC. Application. Security Advice Caution. Notes on Disposal. Combined sensor mixed gas. Data sheet

Instruction Manual Differential Pressure Transmitter

Instruction Manual Contact Pressure Vacuum Gauge

FLAMMABLE GAS SENSOR/TRANSMITTER

Operation Manual. O2 Quickstick. Oxygen Analyzer 08.17

Digital Melting Point Apparatus

Operating Instructions Part No

Columbus Instruments

Calibration Gas Instrument INSTRUCTION MANUAL. Release I. Advanced Calibration Designs, Inc.

* * Data Sheet and Operating Manual. Digital manometer ME01 ## # 87 # HL S#### Dust explosion protection Zone 22.

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 09.14

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

Mounting instructions. Strain transducer SLB-700A. B 26.SLB700A.10 e

Operating Instructions Melt Pressure Sensor

HBLT-A1 LIQUID LEVEL SENSOR

Instruction and Maintenance Manual

DMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0.

Bante810 Benchtop Dissolved Oxygen Meter Instruction Manual

Operating Instructions Part No

JUMO dtrans p30 Pressure Transmitter

Instruction Manual AD 1000 / BA 1000 Absolute Pressure Sensor

SITRANS P measuring instruments for pressure

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)

High-performance submersible pressure transmitter For level measurement Model LH-10

OxiQuant S. Operating Instructions

KERN EG/EW Version /02

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

OSAT Series. Intrinsically Safe Infrared Temperature Sensor Operator's Guide

Mounting and Operating Instructions EB 2172 EN. Series 43 Temperature Regulators. Type 43-5 and Type Type Type 43-6

Englisch. Operating Manual. Dissolved Oxygen Measuring transducer OXY 3610 MP .3X.6C Keep for later use.

Mounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator

Climatic Independent Level Sensor LAR

OPERATING MANUAL CHEMTRAC 840M MANUAL RETRACTABLE PROCESS HOLDER

Tightness controls TC 1 3 and TC 4

Air Sensor. FCS Ex. Manual. AQ Elteknik AB

Proportional pressure regulators VPPE

OxyCheq Expedition-X Oxygen Analyzer. Operator s Manual

High-performance submersible pressure transmitter For level measurement Model LH-10

INSTRUCTION MANUAL MP4AR Remote Convection Gauge Range: 1 x 10-3 Torr to 1 x 10+3 Torr

Mass Flow Controller (MFC) for Gases

Types and approvals. Page 1/6. Data Sheet

PyroCouple Series Operators Guide

MODEL GT820 OXYGEN SENSOR

DM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

Climatic Independent Level Sensor LAR

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar

Rigel 601 CHECKBOX. Instruction Manual. 348A551 Issue 2.0. April Seaward Electronic Ltd. Issue 2.0

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

High-performance submersible pressure transmitter For level measurement Model LH-20

O3 3E 1 F Gas Sensor Module

EC214 EC215 - EC215R Bench Conductivity Meters

Installation, use and maintenance instructions. Gas burner (5)

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

Operating manual. TA 197 Oxi. Dissolved Oxygen Depth Armature

testo Leakage detector for refrigerants Instruction manual

Instruction Manual BA90 Precision Barometer

L 100. Bubble-Tube Level System. Installation, Operation and Maintenance Instructions

P900. P900, Datenblatt Seite 1 DESCRIPTION

Pressure Transmitter P41

Operation Manual. O2 Quickstick. Oxygen Analyzer

Pressure Measurement Single-range transmitters for general applications

OxyScan Graphic. Operating Instructions. UMS Micro-oxygen sensor 501. Microprocessor instrument

Contents. Operating instructions. Pressure switch, heavy-duty version Model PSM-520

DK48 - DK800. Quick Start. Variable area flowmeter

MANUAL DIRECT PURGE OPTION. UNION Instruments GmbH CWD2005 PLUS. General information, safety standards and regulations for direct purge option

Operating Manual VSA100A. tina29e1 ( )

P9000 DESCRIPTION. For parts requiring RoHS compliance, please contact factory. P February /6

L3 Pressure and Level transmitter

Operating Instructions for Intrinsically Safe Pressure Transmitters Series DMG/******** for Hazardous Application in Coal Mining Industry

Mass Flow Controller (MFC) for Gases

AQUARIUS. Operating Instructions for the. Type 70 Electrolytic Gas Soldering / Welding Unit. Table of Contents

JUMO dtrans O2 01 Two-wire Transmitter for dissolved oxygen (DO)

High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20

P499 Heavy Duty Pressure Transducer

Operation manual Level sensor DC-LS-50 Operation Manual Level Sensor DC-LS-50

Mass Flow Meter (MFM) for Gases

OPTIBAR P 1010 C Technical Datasheet

OPERATOR S MANUAL Ar-Gone Weld Gas Analyzer

PRELIMINARY DATASHEET

Electronic gas volume corrector model DGVC-04

PULSAR 5000 SERIES OPERATING & INSTALLATION INSTRUCTIONS SERIES 5000 PLEASE READ CAREFULLY BEFORE INSTALLING

FPD20 Series. Gear wheel flow sensor

Transcription:

T02.0.4X.6C-11 Measuring transducer for air oxygen OXY 3690 MP as of version V1.3 operating manual OXY 3690 MP - LO WEEE-Reg.-Nr. DE 93889386 GHM Messtechnik GmbH Standort Greisinger Hans-Sachs-Str. 26 D-93128 Regenstauf +49 (0) 9402 / 9383-0 +49 (0) 9402 / 9383-33 info@greisinger.de

T02.0.4X.6C-11 page 2 of 6 Safety instructions: This device has been designed and tested in accordance with the safety regulations for electronic devices. However, its trouble-free operation and reliability cannot be guaranteed unless the standard safety measures and special safety advises given in this manual will be adhered to when using the device. 1. Trouble-free operation and reliability of the device can only be guaranteed if the device is not subjected to any other climatic conditions than those stated under "Specification". If the device is transported from a cold to a warm environment condensation may cause in a failure of the function. In such a case make sure the device temperature has adjusted to the ambient temperature before trying a new start-up. 2. General instructions and safety regulations for electric, light and heavy current plants, including domestic safety regulations (e.g. VDE), have to be observed. 3. If device is to be connected to other devices (e.g. via PC) the circuitry has to be designed most carefully. Internal connection in third party devices (e.g. connection GND and earth) may result in not-permissible voltages impairing or destroying the device or another device connected. 4. If there is a risk whatsoever involved in running it, the device has to be switched off immediately and to be marked accordingly to avoid re-starting. Operator safety may be a risk if: - there is visible damage to the device - the device is not working as specified - the device has been stored under unsuitable conditions for a longer time. In case of doubt, please return device to manufacturer for repair or maintenance. 5. This device only serves as supervision by the monitoring of essential or other for the customer important systems. It must not be used instead of compulsory approval monitoring devices and it is not designed for that purpose. If this device is used for the monitoring of such systems on its own, the manufacturer will not assume liability for damages whatsoever. 6. Caution, acid! The sensor contains KOH. This can cause severe chemical burns. If leaking, avoid contact! If there was contact: - to skin: Flush contacted area with large amounts of water for several minutes. - to clothing: remove contaminated clothing. - to eyes: Flush with large amounts of water for several minutes, obtain medical treatment. After swallowing: - give large volumes of water. DO NOT induce vomiting! - Obtain medical treatment. 7. Warning: Do not use these product as safety or emergency stop devices, or in any other application where failure of the product could result in personal injury or material damage. Failure to comply with these instructions could result in death or serious injury and material damage. Disposal notes This device and the sensor must not be disposed as residual waste. According to the ElektroG (law for bringing into market, the return and the environmentally friendly disposal of electronic equipment) we accept the return of this device and/or the sensor, please send it directly to us (adequately stamped). We will dispose it appropriately and environmentally friendly.

T02.0.4X.6C-11 page 3 of 6 Assignment of elbow-type plug: 2-wire connection (4-20mA) 3-wire connection (voltage) 4-wire connection (voltage) 1 = supply voltage +Vs 1 = signal + 1 = signal + 2 = GND / signal 3 = supply voltage +Vs 2 = signal - (4) = supply voltage -Vs 3 = supply voltage +Vs signal - (4) = supply voltage -Vs General installation instructions: To mount the connection cable (2-, 3-, or 4-wire depending on type of device) the elbow-type plug screw has to be loosened and the coupling insert has to be removed by means of a screw driver at the position indicated (arrow). Pull out connection cable through PG glanding and connect to the loose coupling insert as described in the wiring diagram. Replace loose coupling insert onto the pins at the transducer housing and turn cover cap with PG glanding in the direction desired till it snaps on (4 different starting positions at 90 intervals). Re-tighten the screw at the angle plug. Display functions: During normal operation the oxygen content of the air is displayed in the unit [%]. By pressing the Key 2 (down) the temperature at the sensor can be shown, pressing key 3 (up) shows the electrode rating in [%]. The electrode rating is calculated and stored during the calibration (see below). The displays of the rating and the temperature of the sensor are marked by small arrows at the upper end of the display. After 5 seconds the transducer display switches automatically back to the oxygen value. display dissolved oxygen display sensor temperature display electrode rating Calibration of the sensor: Expose sensor to the ambient air, wait until the temperature has adopted to the ambient conditions. Press key "SET" for 2 sec., The display shows "CAL". After approx. 10 sec s the transducer is calibrated or a referring error message will be shown: Display Meaning Possible fault causes Remedy CFE.1 temperature out of allowed range sensor error temperature has to be within 5 to 40 C temperature sensing defective calibrate again at correct temperature check cable & connection, replace sensor if necessary CFE.3 wrong signal: to low sensor element used up replace sensor element CFE.4 wrong signal: to high calibration surrounding not valid check Calibration surrounding CFE.6 instable signal calibration surrounding not valid check Calibration surrounding During calibration the rating of the electrode is evaluated: 100% means perfect state, 40 % means e.g. sensor element has a weak output signal and needs to be replaced soon (p.r.t. sensor manual). The electrode rating can be displayed with key 3 (down).

T02.0.4X.6C-11 page 4 of 6 Configuration of the device For the correct function of the device in its application, it has to be configured to meaningful settings. For doing this the cover has to be removed. Then the jumper J1 right above of key 2 has to be set. Then use following configuration procedure: 1. Press key one more than 4 sec s until PAbS appears in the display Now PAbS and the referring setting are shown alternating I.) Average ambient absolute pressure PAbS (function of the altitude above sea level): Necessary for a correct evaluation of the electrode rating. If the application works for example at an altitude of 275 m above sea level, 980mbar is a correct setting. Please refer to Appendix A 2. Enter the desired value by using keys 3 (up) and 2 (down). Input range: 500...2000 mbar 3. Acknowledge the value with key 1 (set). 4. The settings are stored. The unit starts up again. (8888 in display) Attention: Bring back the jumper j1 to the parking position after configuration (one contact connected, the second contact on air )! Then the device can be calibrated by key 1 and the configuration data is protected. Error and System Messages Display Description Possible fault cause Remedy FE 1 measuring range exceeded Calibration is wrong Recalibrate the transducer. FE 2 Measuring values below measuring range Wrong signal FE 7 System fault Error in device FE 9 8.8.8.8 Input signal is not valid Segment test Input signal is not valid Sensor not connected or cable defective Temperature out of range Check the connections, cable and sensor. Disconnect from supply and reconnect. If error remains: return to manufacturer Check sensor, cable and connections Check temperature The transducer performs a display test for 2 seconds after power up. After that it will change to the display of the measuring. Sensor not connected Permissible input range is exceeded Check sensor, cable and connections Check if not a wrong sensor is connected. Replace sensor. Appendix A: abs. ambient pressure as a function of the altitude above sea level Altitude [m] Pabs [mbar) Altitude [m] Pabs [mbar) Altitude [m] Pabs [mbar) -100 1025 600 943 1600 835 0 1013 700 932 1800 814 100 1001 800 920 2000 794 200 989 900 909 2500 746 300 977 1000 898 3000 701 400 966 1200 877 4000 616 500 954 1400 856 Values between are to be interpolated

T02.0.4X.6C-11 page 5 of 6 Appendix B: oxygen sensor General information about the oxygen sensors I.) Lifetime: At the end of life time the sensor signal drops relatively fast. The electrode evaluation in % therefore just can be used for orientation. An evaluation of 70% does not mean that 70% of life time are remaining, but 70% of the reference signal are available, which happens normally at the end of life time. Note: The electrode evaluation is updated by the instrument every time, when the calibration of the sensor was performed successfully. (please also see the referring manual of the instrument) The nominal life time can be shortened significantly by usage. Influencing factors are: - Storage- / Operation temperature - Humidity of measured gas: If permanently used with dry gases (technical gases, bottled gas) the life time decreases considerably. It helps, if the sensor is brought to normal humid ambient air in measuring breaks ( flush system with fresh air). II.) Operating position: The optimum operation position is with the sensor inlet pointing downwards, maximum differential pressure to ambient is 250 mbar. III.) Measuring precision: The measuring precision can be influenced by: - Liquids at the sensor inlet. Rinse the inlet and dry with lint-free cloth. Attention: avoid liquids of any kind at the contacts - Gas and sensor temperature have to be at same level. Best precision, when calibrated at measuring temperature. - Pressure fluctuations: The sensor is originally a partial pressure sensor, i.e. changes in the absolute pressure are influencing the measuring result directly proportional. A pressure change of 1% will cause a additional measuring error of 1%! For optimum precision calibrate at the same conditions at which You want to measure. Application of the different sensor types GGO... /MU (standard) and GOO... / MU (option) GGO... (closed sensor) For measurements at atmosphere and in systems without over or under pressure the GGO is sufficient. Additionally the GGO can be screwed impermeable to systems with low over or under pressure. Attention! If the sensor cannot be calibrated at exactly the same pressure, the measurement will be faulty! For such applications we have integrated a manual pressure compensation. Then the GGO can be connected to systems with a known pressure (Attention: please note the specified operating pressure for one-sided strain). The pressure can be entered to the device an will compensated by the device such no additional measuring error will occur. GOO... (open sensor) The sensor is equipped with drillings at the end and because of its special construction the measuring gas streams optimally around the sensor. No pressure can appear while gas blows to the sensor, which otherwise would result in erroneous measures. The temperature compensation speed of the sensor also is optimised by this design. The measuring gas escapes into the air. Especially the measuring of gases from compressed gas bottles, where the expansion of the gas leaving the bottle lowers the temperature, is optimised with regard to the temperature compensation and pressure errors. The gas flow should be chosen in a suitable range, where no overpressure can happen, esp. if the sensor is connected directly to the source e.g. by means of a tube. Oxygen measuring notes Calibration and measuring are depending of the absolute pressure at the sensor. Therefore check the absolute pressure before calibration and measuring. Sensor temperature and gas temperature should be the same. Temperature differences may cause additional measuring errors! In worst case conditions it may take up to several hours until both temperatures are adjusted. A suitable flow of the gas around the sensor element increases the adjustment significantly.

T02.0.4X.6C-11 page 6 of 6 Specification: OXY 3690 MP OXY 3690 MP - LO Display range: 0,0... 100,0 % air oxygen 0,0... 100,0 % air oxygen Rec. sensor meas. range: 0,0... 100,0 % air oxygen 0,0... 25,0 % air oxygen Sensor name: (Standard) GGO 370 / MU GGO 380 / MU Sensor type: electrochemical partial oxygen pressure sensor electrochemical partial oxygen pressure sensor Meas. range O2-Concentration: 0,0... 100,0 % O 2 (gaseous) 0,0... 25,0 % O 2 (gaseous) Electrolyte: basic acid Response time: 90% at <10sec., depending on temperature 90% at <15sec., depending on temperature Linearity: < 2 % O 2 ± 0.2 % O 2 ± 0.1 % O 2 < 25 % O 2 ± 0.5 % O 2 ± 0.5 % O 2 > 25 % O 2 ± 1.0 % O 2 not specified Cross sensitivities: signal of <0.1 % O 2 at signal of <0.002 % O 2 at: 15% CO2 in N2, 10% CO in N2, 3000ppm NO in N2, 100% CO2, 100% CO, 3000ppm NO in N2, 3000ppm C3H8 in N2, 500ppm H2S in N2, 1000ppm Benzene in N2 1000ppm H2 in N2, 100% C3H8, 2000ppm H2S in N2, 2000ppm SO2 in N2, 1000ppm Benzene in N2 Working temperature: 0... +50 C 0... +45 C Operating pressure: 0.5 to 2.0 bar absolute (at one-sided strain: max. 0.25 bar over-/under-pressure) Warranty period: 12 months (assuming appropriate usage according to the manual) Nominal sensor life: approx. 2 years at nominal condition Temperature compensation: integrated in oxygen sensor Sensor connection: 5-pole screwable socket Device accuracy: Display add. output signal: Output signal: Connection: ±0,1% oxygen ±1digit (adjusted device, at nominal temperature = 25 C) ±0,2 % FS refer to type plate 4-20 ma (2-wire) Voltage (3- or 4-wire) Auxiliary energy: (supply voltage) Uv = 12-30 V DC (4-20mA) Uv = 18-30 V DC (0-10V) or refer to type plate Electric isolation: input electrically isolated Reverse voltage protection: 50V permanent Perm. impedance (at 4-20mA): R A (Ohm) < ( (Uv - 12V) / 0.02A ) Example: for Uv = 18V: R A < (18V - 12V) / 0.02A => R A < 300 Ohm Permissible load (at 0-...V): Display: Working conditions: Storage temperature: Housing: Dimensions: Mounting: Mounting distance: Sensor dimensions: Electric connection: EMC: R L (Ohm) > 3000 Ohm approx. 10 mm high, 4-digit LCD-display 0... 45 C, 0... 95 %RH (non-condensing) -20... 70 C (sensor: -15... 50 C) ABS (IP65 - with the exception of sensor and temperature probe connection sockets) 82 x 80 x 55 mm (without elbow-type plug and sensor sockets) with fixing holes for wall mounting (in housing - accessible after cover has been removed) 50 x 70mm, max. shaft diameter of mounting screws is 4 mm. GGO3x0..: approx. Ø 36 mm x 95 mm (150 mm incl. anti-buckling glanding), GOO3x0..: approx. Ø 40 mm x 105 mm (160 mm incl. anti-buckling glanding) Housing with M16 x 1-screw thread (sensor can be connected to line tubes by means of an additional adapter) elbow-type plug conforming to DIN 43650 (IP65), max. wire cross section: 1.5 mm², wire/cable diameter from 4.5 to 7 mm The device corresponds to the essential protection ratings established in the Regulations of the Council for the Approximation of Legislation for the member countries regarding electromagnetic compatibility (2004/108/EG). In accordance with EN50081-1 and EN50082-1 Additional error: <1%