LMP 307. Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0.

Similar documents
x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

x act i Precision- Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor

DMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0.

High-performance submersible pressure transmitter For level measurement Model LH-10

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

High-performance submersible pressure transmitter For level measurement Model LH-20

High-performance submersible pressure transmitter For level measurement Model LH-10

High-performance submersible pressure transmitter For level measurement Model LH-20

OPTIBAR P 1010 C Technical Datasheet

High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

High-performance submersible pressure transmitter For level measurement Model LH-20

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05

DM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

Pressure Measurement Single-range transmitters for general applications

L (up to 25 m) Electronic part. working temp.: Ñ IP 66 / IP67. Mounting bracket ÐÑ. Sensor type. working temp.:

Digitale manometers. TYPE: ETD-01, klasse 0.5. Specificaties HOOFDSTUK 6

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI

SITRANS P measuring instruments for pressure

Technical Data. General specifications. Rated operating distance s n 5 mm

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition

PRODUCT CATALOGUE DIGITAL GAUGES

9700 Transmitter Submersible hydrostatic level transmitter

1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure

Technical Data. Dimensions

JUMO dtrans p30 Pressure Transmitter

Gas density monitor With integrated transmitter Model GDM-100-TI

Technical Data. Dimensions

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/16 Siemens FI US Edition

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

Technical Data. General specifications Switching element function Rated operating distance s n 2 mm

Technical Data. General specifications Switching element function Rated operating distance s n 1.5 mm

Pressure Measurement Single-range transmitters for general applications

ATM.ECO/IS - Analog Transmitter with Temperature compensation

Technical Data. Dimensions

ATM.1ST/Ex - High Precision Transmitter

Submersible pressure sensor High-performance Model LH-20

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Electropneumatic Positioner Type 4763 Pneumatic Positioner Type 4765

Technical Data. Dimensions

ATM/Ex - Intrinsically Safe Analog Pressure Transmitter - ATEX / IECEx Certified

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 10 mm

NivuBar Plus II

Hidrostatic Level DATASHEET

Technical Data. Dimensions

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. General specifications. Rated operating distance s n 2 mm

Pressure Measurement Single-range transmitters for general applications

Expert Hydrostatic Level Transmitters

Digital pressure gauge Model CPG500

Level sensing relative and absolute pressure transmitter type 712

Picture. Minimum cable bending radius 100 mm [4"] < 400 N [90 lbf] (PE / PUR cables) < 15 N [3.4 lbf] (FEP cables)

Pressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview

JUMO MAERA. Level probes Types , , , Installation Instructions T94Z001K000 V4.00/EN/

ATM/Ex - Analog Pressure Transmitter

OSAT Series. Intrinsically Safe Infrared Temperature Sensor Operator's Guide

Bourdon tube pressure gauge for diaphragm seals

Type N-10, N-11 Hazardous Area Non-incendive Transmitters

Pressure Transmitter P41

Precision pressure sensor Basic version Model CPT6020

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

Liquid level instruments BM 24 /BM 51

Technical Datasheet. D Series SMART Pressure Transmitter Model: DPC D-Series. Key Features. Series Overview. Product applications

ATM - Analog Pressure Transmitter

Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC

ED 701 Hygenic Pressure Transmitter

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

Technical Data. Dimensions

Technical Data. Dimensions

Miniature flowmeters DK 46, DKR 46 DK 47, DK 48, DK 800

Level transmitter LT 100

Precision digital pressure gauge Model CPG1000

KTE6000 / KTU6000 Series OEM pressure transmitters for industrial media

ATM/GR. Electronic pressure switches CUSTOMER BENEFITS

ATM.ECO - Analog Pressure Transmitter

Hydrostatic. Continuous level measurement. Overview Page 188 VEGAWELL 52 Page 190 VEGABAR 86, 87 Page 192 Accessory Page 196 AL-EN

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

Operating Instructions for Intrinsically Safe Pressure Transmitters Series DMG/******** for Hazardous Application in Coal Mining Industry

INDUSTRIAL. Pressure Transmitters. Product Guide. Low cost to high accuracy portfolio. Ranges from 70 mbar to 1400 bar. Flexible, rugged and reliable

Programmable Submersible Level Transmitters

C-Flow Coriolis Mass Flow Meters

4/2 way Pneumatic Solenoid Valve

Climatic Independent Level Sensor LAR

P900. P900, Datenblatt Seite 1 DESCRIPTION

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Pressure transmitter PASCAL Ci4

LEVEL Transmitters. ) of the liquid column above it and the atmospheric pressure (P atm

DK46 - DK800 Supplementary instructions

MJK Expert 700 / 800 / 900 / 7070 / 7060 MJK Expert 1400 / 3400

SITRANS. Pressure transmitter SITRANS P, Z series for gauge and absolute pressure. Introduction. Safety instructions 2.

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Pressure Switches Application Guideline

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

Relative pressure transmitter type 520

Safety Instructions Liquiphant FailSafe FTL80, FTL81, FTL85

Vortex flow sensor VA Di Ex-d with integrated, configurable transducer UVA in a flameproof enclosure for applications in explosive atmospheres

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Technical Data. Dimensions

Transcription:

LMP 07 Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % / 0. % FSO Nominal pressure from 0... mho up to 0... 50 mho Output signals -wire: 4... 0 ma -wire: 0... 0 ma / 0... 0 V others on request Special characteristics diameter 6.5 mm small thermal effect excellent accuracy excellent long term stability Optional versions IS-protection zone 0 SIL (Safety Integrity Level) drinking water certificate according to DVGW and KTW different kinds of cables different kinds of seal materials The stainless steel probe LMP 07 is designed for continuous level measurement in water and clean or lightly polluted fluids. Basic element is a high quality stainless steel sensor with high requirements for exact measurement with excellent long term stability. Preferred areas of use are Water / filtrated sewage drinking water system ground water level measurement rain spillway basin pump and booster stations level measurement in container water treatment plants water recycling Fuel / Oil fuel storage tank farm BD SENSORS GmbH BD-Sensors-Straße Tel: +49 (0) 9 5 / 98-0 www.bdsensors.com D - 9599 Thierstein Fax: +49 (0) 9 5 / 98 - info@bdsensors.de

LMP 07 Technical Data Input pressure range Nominal pressure gauge [bar] 0. 0.6 0.5 0.4 0.6.6.5 4 6 0 6 5 Level [mh O].6.5 4 6 0 6 5 40 60 00 60 50 Overpressure [bar] 0.5 5 5 0 0 0 40 40 80 80 Burst pressure [bar].5.5.5 7.5 7.5 5 5 5 50 50 0 0 Output signal / Supply Standard -wire: 4... 0 ma / V S = 8... V DC SIL-version: V S = 4 8 V DC Option Ex-protection -wire: 4... 0 ma / V S = 0... 8 V DC SIL-version: V S = 4 8 V DC Options -wire -wire: 0... 0 ma / V S = 4... 0 V DC 0... 0 V / V S = 4... 0 V DC Performance Accuracy standard: nominal pressure < 0.4 bar: ± 0.5 % FSO nominal pressure 0.4 bar: ± 0.5 % FSO option : nominal pressure 0.4 bar: ± 0.5 % FSO option : for all nominal pressures: ± 0. % FSO Permissible load current -wire: R max = [(V S V S min ) / 0.0 A] current -wire: R max = 500 voltage -wire: R min = 0 k Influence effects supply: 0.05 % FSO / 0 V load: 0.05 % FSO / k Long term stability ± 0. % FSO / year at reference conditions Response time -wire: 0 msec -wire: msec accuracy according to IEC 60770 limit point adjustment (non-linearity, hysteresis, repeatability) Thermal effects (Offset and Span) Nominal pressure P N [bar] < 0.40 > 0.40 Tolerance band [% FSO] ± ± 0.75 in compensated range [ C] 0... 70 Permissible temperatures Permissible temperatures medium: -0... 70 C storage: -5... 70 C Electrical protection Short-circuit protection permanent Reverse polarity protection no damage, but also no function Electromagnetic compatibility emission and immunity according to EN 66 additional external overvoltage protection unit in terminal box KL or KL with atmospheric pressure reference available on request Electrical connection Cable with sheath material PVC (-5 70 C) grey PUR (-0 70 C) black FEP 4 (-0 70 C) black TPE-U (-0 70 C) blue (without/with drinking water certificate) cable with integrated air tube for atmospheric pressure reference 4 do not use freely suspended probes with an FEP cable if effects due to highly charging processes are expected Materials (media wetted) Housing stainless steel.4404 (6L) Seals FKM EPDM (without/with drinking water certificate) others on request Diaphragm stainless steel.445 (6L) Protection cap POM-C Explosion protection (only for 4... 0 ma / -wire) Approvals DX9-LMP 07 IBExU 0 ATEX 068 X / IECEx IBE.007X zone 0: II G Ex ia IIC T4 Ga zone 0: II D Ex ia IIIC T 85 C Da Safety technical maximum values U i = 8 V, I i = 9 ma, P i = 660 mw, C i 0 nf, L i 0 µh, the supply connections have an inner capacity of max. 7 nf to the housing Ambient temperature range in zone 0: -0... 60 C with p atm 0.8 bar up to. bar in zone or higher: -0... 70 C Connecting cables cable capacitance: signal line/shield also signal line/signal line: 60 pf/m (by factory) cable inductance: signal line/shield also signal line/signal line: µh/m Miscellaneous Option SIL version 5 according to IEC 6508 / IEC 65 Drinking water certificate 6 according to DVGW W 70 and UBA KTW (with order the indication "with drinking water certificate" is necessary) Current consumption signal output current: max. 5 ma signal output voltage: max. 7 ma Weight approx. 00 g (without cable) Ingress protection IP 68 CE-conformity EMC Directive: 04/0/EU ATEX Directive 04/4/EU 5 not in combination with the accuracy 0. %, only for 4...0 ma / -wire 6 only possible with EPDM seal in combination with TPE-U cable; not possible with IS-protection (explosion protection) pressure and level

LMP 07 Technical Data Wiring diagrams -wire-system (current) -wire-system (current / voltage) p supply + p supply + VS VS supply I supply I/U signal + A/V Pin configuration Electrical connection cable colours (IEC 60757) Dimensions (in mm) Supply + Supply Signal + (only -wire) Shield wh (white) bn (brown) gn (green) gnye (green-yellow) Total length of devices with accuracy 0. % FSO IEC 60770 increases by 5 mm! www.bdsensors.com

LMP 07 Technical Accessories Data Mounting flange with cable gland Technical data Suitable for all probes Flange material stainless steel.4404 (6L) Material of cable gland standard: brass, nickel plated on request: stainless steel.405 (0); plastic Seal insert material: TPE (ingress protection IP 68) Hole pattern according to DIN 507 Version Size (in mm) Weight DN5 / PN40 D = 5, k = 85, b = 8, n = 4, d= 4.4 kg DN50 / PN40 D = 65, k = 5, b = 0, n = 4, d= 8. kg DN80 / PN6 D = 00, k = 60, b = 0, n = 8, d= 8 4.8 kg Ordering type Ordering code DN5 / PN40 with cable gland brass, nickel plated ZMF540 DN50 / PN40 with cable gland brass, nickel plated DN80 / PN6 with cable gland brass, nickel plated Terminal clamp Technical data Suitable for all probes with cable 5.5... 0.5 mm Material standard: steel, zinc plated optionally: stainless steel.40 (04) Weight approx. 60 g Ordering type Terminal clamp, steel, zinc plated Terminal clamp, stainless steel.40 (04) Display program ZMF5040 ZMF806 Ordering code Z0058 Z0057 CIT 00 Process display with LED display CIT 50 Process display with LED display and contacts CIT 00 Process display with LED display, contacts and analogue output CIT 50 Process display with LED display, bargraph, contacts and analogue output CIT 400 Process display with LED display, contacts, analogue output and Ex-approval CIT 600 Multichannel process display with graphics-capable LC display CIT 650 Multichannel process display with graphics-capable LC display and datalogger CIT 700 Multichannel process display with graphics-capable TFT monitor, touchscreen and contacts PA 440 Field display with 4-digit LC display For further information please contact our sales department or visit our homepage: http://www.bdsensors.com cable gland M6x.5 with seal insert (for cable- 4... mm) 08 BD SENSORS GmbH The specifications given in this document represent the state of engineering at the time of publishing. We reserve the right to make modifications to the specifications and materials. pressure Tel: +49 and (0) level 9 5 / 98-0 www.bdsensors.com Fax: +49 (0) 9 5 / 98 - info@bdsensors.de LMP07_E_048

Ordering code LMP 07 LMP 07 - - - - - - - - - - Pressure in bar in mh O 4 5 0 4 5 Input [mh O] [bar].0 0.0 0 0 0.6 0.6 6 0 0.5 0.5 5 0 0 4.0 0.40 4 0 0 0 6.0 0.60 6 0 0 0 0.0 0 0 6.6 6 0 5.5 5 0 40 4.0 4 0 0 60 6.0 6 0 0 00 0 0 0 60 6 6 0 50 5 5 0 9 9 9 Housing stainless steel.4404 (6L) Diaphragm stainless steel.445 (6L) Output 4 0 ma / -wire 0 0 ma / -wire 0 0 V / -wire intrinsic safety 4 0 ma / -wire SIL 4 0 ma / -wire SIL with Intrinsic safety 4 0 ma / -wire E S ES Seals FKM EPDM DVGW/KTW: EPDM T Accuracy standard for P N 0.4 bar 0.5 % standard for P N < 0.4 bar 0.5 % 5 option for P N 0.4 bar 0.5 % option 0. % Electrical connection PVC cable PUR cable FEP cable TPE-U cable 4 DVGW/KTW:, TPE-U cable F Cable length in m standard: m PVC 0 0 standard: 5 m PVC 0 0 5 standard: 0 m PVC 0 0 standard: 5 m PVC 0 5 standard: 0 m PVC 0 0 special length PVC 9 9 9 standard: m PUR 0 0 standard: 5 m PUR 0 0 5 standard: 0 m PUR 0 0 standard: 5 m PUR 0 5 standard: 0 m PUR 0 0 special length PUR 9 9 9 standard: 5 m FEP 0 0 5 standard: 0 m FEP 0 0 special length FEP 9 9 9 special length TPE-U 9 9 9 Special version standard 0 0 0 9 9 drinking water certification only possible with EPDM seal (code T) in combination with TPE-U cable (code F); not possible with IS-protection (explosion protection) not in combination with SIL cable with integrated air tube for atmospheric pressure reference Standard lengths / 5 / 0 / 5 / 0 m are available from stock, special lengths are manufactured order-related.04.08 08 BD SENSORS GmbH The specifications given in this document represent the state of engineering at the time of publishing. We reserve the right to make modifications to the specifications and materials.