Sullair Air Systems. *Assessment of the market for compressed air efficiency services. Technical report, U.S. Department of Energy, June 2001

Similar documents
4-7 kw/ hp. Dual Output Compressors (Air/Nitrogen) Driving Nitrogen Forward

/ /

Let s examine the evolution and application of some of the more popular types. Cascading Pressure Type

Reliability: Piping Distribution & Storage Matter. Instructor: Kurt Thielemann Principal

SULLAIR SX Filtration Series ,000 scfm

I T T Pressure Reducing Valve WARNING INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

OPERATION MANUAL NTF-15

Nitrogen Advantage. Better Tire Pressure Retention. Improved Fuel Economy. Extended Tread Life. Elimination of Oxidation. Reduction in Tire Failures

OPERATION MANUAL NTF-60 Plus

OPERATING INSTRUCTIONS Pressure Control System PCS-20 through PCS-100

COMPRESSED AIR DISTRIBUTION SYSTEMS

TECHNICAL BULLETIN DESIGNING A FUNCTIONAL COMPRESSED AIR SYSTEM

CONTROL SOLUTIONS DESIGNED TO FIT RIGHT IN. Energy Control Technologies

Standard Operating and Maintenance Instructions for Pumping System Model PS-90

Pressure on Demand. Air Pressure Amplifiers

USER MANUAL. FlowLogic SFL Flow Controller WARRANTY NOTICE

Fundamentals of Compressed Air Systems. Pre-Workshop Assignment

MEDICAL EQUIPMENT CATALOG

The most common terms rating air flow capacity are ICFM, FAD, ANR, SCFM or nl/min

THE IMPACT ON ENERGY CONSUMPTION CAUSED BY PRESSURE DROP IN A COMPRESSED AIR SYSTEM

Genie Supreme TM Model 123HP Installation & Operation Instructions


Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.

Bermad Pressure Reducing. Model: 42T

Genie Supreme Model 123 Installation & Operation Instructions

Model: 720-UL INSTALLATION OPERATION MAINTENANCE. Bermad Pressure Reducing Valve IOM. Model: FP -720-UL Sizes: 2"-12" BERMAD. Application Engineering

RMG 5020 Gas Pressure Regulator Enabling Dependable Gas Operations

SINGER MODEL 106/206-RPS-L&H

Best Practices Pneumatics Machine & Design. Written by Richard F. Bullers, CFPPS as published in Fluid Power Journal, July/August 2016

Screw Compressors 11-22kW

CHAPTER 3 : AIR COMPRESSOR

Advanced Management of Compressed Air Systems Pre-Workshop Assignment

Model 10. Low-Medium Pressure Reducing Regulator

Oil-injected rotary screw compressors GA (VSD + )

ENERGY CONSERVATION IN PNEUMATIC SYSTEMS. Solutions That Save

ON-SITE INDUSTRIAL GASES. Nitrogen & Oxygen Generators

MATHESON s LaserPro Gases and Gas Delivery Equipment

Pressure and/or Temperature Pilot Operated Steam Regulators Series 2000

Spring Loaded Regulators Constant Loaded Regulators Twin Parallel Flow Regulators Field Service Regulators

Air Amplifiers & SYSTEMS

ECS Protector Nitrogen Generator PGEN-30 (PGEN-30E)

Technical Information

TECHNICAL INFORMATION

Tradition & Technology

TECHNICAL INFORMATION

Data Sheet Issue A

SRL SEries. Oil Free Scroll Air Compressors hp kw

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

Net$ync II. Net$ync II. System Controllers

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

WW-720. Pressure Reducing Control Valve

QGV Series. Quincy QGV Series. Rotary Screw Air Compressors hp

Model DDX-LP Dry Pipe Valve System 8 (200mm) Features. Differential latching clapper-type, lighweight, dependable construction.

3M TM Versaflo TM AP-600 Series Air Filtration Panels For use with 3M TM Versaflo TM Supplied Air Respirator Systems. Work. in a World of.

Avenger Model 33M Installation & Operation Instructions

Installation and User Manual

WW-720. Pressure Reducing Control Valve

SECTION 11 VACUUM GRIPPER

ACCU-PULSE Installation and Operation Instructions

SRL Series. Oil-less Scroll Air Compressors. Pharmaceutical. Research & Development. Food & Beverage. Chemical. Electronic

Optimizing Compressed Air Storage for Energy Efficiency

Medical Oxygen Concentrator Systems. Generate gases on site generate savings

CSA Sample Draw Aspirator Adapter Operator s Manual

V48 Series 3-Way Pressure-Actuated Water-Regulating Valves With Union Fittings

FUNDAMENTALS OF PRESSURE REGULATORS ROBERT BENNETT MANAGER OF TRAINING ELSTER AMERICAN METER

V43 Pressure Actuated Water Regulating Valve

1 Exam Prep NFPA 99 Health Care Facilities Questions and Answers (Plumbing Contractor)

SINGLE VALVE WITH LOW-FLOW BYPASS

Potter Nitrogen Generators

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

Liquid Level Controllers

The Shand & Jurs Model Vapor Guard Tank Blanketing Valve

V46 Series 2-Way Pressure-Actuated Water-Regulating Valves With Union Fittings

GLOSSARY OF TERMS. Adiabatic Compression Compression process when all heat of compression is retained in the gas being compressed.

TECHNICAL DATA. Q = C v P S

CAPITAL CONTROLS SERIES NXT3000

1200 Series Pressure Regulators

B84G - Excelon Plus Modular System General purpose filter/regulator

Cash Valve TYPE G-4 PILOT OPERATED PRESSURE REDUCING REGULATOR FOR STEAM, AIR AND GASES. ISSUED - MARCH 2001 CAVMC-0512-US-0208 ISO 9001 Certified

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER FILTER DRYER

Installation, Operation, and Maintenance Manual

Installation, Operation, and Maintenance Manual Parker Balston Model N2-04 Nitrogen Generator

Air Eliminators and Combination Air Eliminators Strainers

AIR DRIVEN. Gas Boosters & SYSTEMS. Accepting VISA, MasterCard and American Express

accidents which arise due to non-observance of these instructions and the safety information herein.

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

Locator Locator-D-Lux Air-Saver G1 Air-Saver G2

Features. Model DDX-LP Dry Pipe Valve System 4 (100mm), 6 (150mm) & 165mm Sizes

EGL-12 OIL-LESS COMPRESSOR

COMPRESSORS AND COMPRESSED AIR SYSTEMS

Membrane modules for nitrogen and oxygen generator systems. Technology Overview ENGINEERING YOUR SUCCESS.

Model: 43T. Bermad Pressure Relief Valve

TECHNICAL DATA. the Viking Pilot Pressure Regulating Valve 1 Model A-1 Speed Control Assembly: OBSOLETE. the Viking Speed Control Assembly 1

Standard Operating and Maintenance Instructions for Pumping System Model PS-150

Nirvana Variable-Speed Drive, Contact-Cooled Rotary Screw Air Compressors

TEK-M ANIFOLD 7500A. Manifolds. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys ACCESSORIES

Operating Manual. Model BAC-30RT30/BAC-30DC

Cash Valve. Type G-4. Pilot Operated Pressure Reducing Regulator for Steam, Air and Gases. Flow Control

TECHNICAL DATA Q= C. Table 1 - Specifications

Constant and Particle Free Point-of-Use Water Pressure

Transcription:

Sullair Air Systems The three most expensive components in operating a compressed air system are: inadequate, inefficient controls that waste energy; lost production due to an improperly maintained system; and leaks. By taking control of your system and using a Sullair FlowLogic TM Flow Pressure Controller, it can provide you with efficient volume and pressure relation of compressed air delivery, ensuring your system delivers the required flow, pressure and level of air quality at the lowest cost--no more, no less. To stay competitive in today s environment, a manufacturer must have tight control of their costs. Compressed air, considered the industry s fourth utility, is often a significant cost of production. According to experts at the U.S. Department of Energy, 15-60%* of compressed air system usage can be saved with a payback in less than two years. Many typical compressed air systems waste 50%* of the air produced, providing a tremendous opportunity to reduce production costs. That is where Sullair comes in, providing total compressed air systems to help you reduce energy costs and improve productivity by analyzing, managing and controlling your compressed air systems. Sullair air systems include: plant air audits, energy efficient products, compressed air system controls, equipment to monitor and manage systems, air distribution products and after-purchase support. Each component of the system is carefully matched for capacity and pressure to help provide maximum performance and energy efficiency. A total Sullair system provides the user with an air quality guarantee. According to the U.S. Department of Energy, more than half* of industrial plant air systems are candidates for large energy savings opportunities with relatively low project costs. 2 *Assessment of the market for compressed air efficiency services. Technical report, U.S. Department of Energy, June 2001

Sullair Total Air System This system includes: rotary screw compressor wet storage refrigerated or desiccant dryer filters to meet your requirement dry storage flow controller drains oil/water separator ethernet-based econnect to monitor and control the entire system Sullair FlowLogic TM Flow Pressure Controller is a critical component of the total air system. The Controller s unique parallel design allows a very small movement in the valve to affect a large change in flow, making it a high gain device and quick to respond. The Controller also holds its system pressure set-point throughout the flow range of the valve, all the way to the point of zero flow. Sullair.com 3

Fluctuating Compressed Air Problem... Fluctuating compressed air pressure often results in poor system performance. Most plant air systems have sufficient compressed air capacity. The problem is distributing this capacity where and when it is needed in the system. Peak demands will often exceed capacity. The deficiency is made up by drawing air from the distribution system. To compensate for these demands, the system pressure is increased, leading to significant energy waste. Significant Compressed Air System Pressure Changes Often Lead to: Wear and fatigue on compressor and air-using equipment Decreased productivity Poor product quality High operational costs Compressed air-related complaints Wasted energy Compressed air system without Sullair's Sullair s FlowLogic flow pressure controller SYSTEM PRESSURE SYSTEM DEMAND SYSTEM DEMAND SYSTEM PRESSURE MINIMUM ACCEPTABLE PRESSURE TOTAL COMPRESSOR CAPACITY NOMINAL PRESSURE Compressed air air system with Sullair s Sullairʼs FlowLogic flow flowpressure controller SYSTEM PRESSURE SYSTEM DEMAND SYSTEM DEMAND NOMINAL COMPRESSOR PRESSURE STORAGE PRESSURE SYSTEM PRESSURE TOTAL COMPRESSOR CAPACITY MINIMUM ACCEPTABLE PRESSURE 4 3

Sullair FlowLogic Controllers help deliver required flow and pressure at the lowest possible cost! The new Sullair FlowLogic SFL Flow Controllers feature more than a fresh look. Improvements include: Removable dashboard Black anodized aluminum header tubes SFLE option includes ModBus RTU communication New PM kits include all required parts, even for SFL/SFE The Principal Causes of Air Pressure Fluctuation are: Lack of useful storage Insufficient on-line horsepower to meet peak demands The traditional response was to overpower the system by increasing the pressure or adding compressors. Maintain minimum pressure but higher pressure was OK Maintain air supply but oversupply was OK There is a new paradigm for your compressed air system. Oversupply is not the answer. The answer is delivering the required flow, pressure and level of air quality at the lowest cost--no more, no less. Sullair FlowLogic Controllers provide a product-based solution in the total air system approach by managing the distribution of compressed air to production. This is done by creating upstream storage and controlling its flow into the plant air system. Results may include: Stable system pressure (± 1% or better) Reduced energy consumption Improved productivity Fewer complaints Compressed air system with Sullair s FlowLogic flow pressure controller There are almost always periods where there is excess compressor capacity, of which the Sullair FlowLogic Controller takes advantage. The Controller stores compressed air whenever excess capacity is available. The Controller then releases the stored air to satisfy the demand peaks, allowing compressed air to be drawn from storage rather than directly from the compressors. Sullair.com 5

Why Choose FlowLogic? FlowLogic helps stabilize air pressure, lower energy and operating costs, and improve productivity. Features Include: Standard sizes from 150 to 5500 scfm Compact integrated assembly Inlet and system pressure gauges Tamper-resistant servo-pilot controls outlet pressure One-year warranty FlowLogic Can Improve Production Helps stabilize air pressure Often lowers product defects and scrap Helps improve consistency of finished product quality Can minimize (or eliminate) compressed air related complaints Options 3-valve manual bypass Low pressure fail-safe with optional automatic bypass Electronic Control Pressure scheduling Communications capability FlowLogic Can Save Money Helps reduce the effect of compressed air leaks Helps reduce number of compressors required Helps reduce maintenance costs FlowLogic Controllers can pay for themselves in energy saving alone in as little as six months The units are designed with a multi-paralleled valve system to provide instant response. A unique fail-safe bypass circuit (optional) minimizes the risk of production interruptions due to power loss or other system malfunctions. Re-locatable dashboard (standard feature) Inlet pressure gauge System pressure control System pressure gauge SFLE Electric Control Panel Robust tubular header design 6

How They Work FlowLogic Controllers address fluctuating air pressure at your work stations where it counts. The Sullair FlowLogic Controller monitors the air pressure as it s delivered. The Controller provides a stable air supply at the lowest optimal pressure. Pressure fluctuations are eliminated. Compressor performance is optimized because it no longer has to react to the dynamic loading imposed by production. Sullair FlowLogic Controller takes advantage of the peaks and valleys in the demand cycle by storing compressed air whenever excess capacity is available. The Controller then releases the stored air to satisfy the demand peaks, allowing compressed air to be drawn from storage rather than directly from the compressors. An air-using operation that needs only 50 cubic feet of air for 5 seconds, requires 125 hp of on-line compressor to handle it. Releasing 50 cubic feet of air from storage, and replenishing storage over a less than two minute period, would require the equivalent of a 7.5 hp compressor. The advantages of operating a 7.5 hp compressor over a 125 hp compressor is clear. Sullair.com 7

FlowLogic Specifications Nominal flow ratings Maximum inlet temperature 125 F (51.7 C) Based on 100 120 psig (6.9 8.3 bar) inlet pressure 100 F (38 C) inlet temperature 100 F (38 C) ambient temperature 5 psig (.3 bar) control pressure differential Maximum inlet pressure 150 1750 cfm (4.2 49.6 m 3 /min): 200 psig (13.8 bar) 2600 5500 cfm (73.6 155.7 m 3 /min): 150 psig (10.3 bar) Consult factory for higher inlet pressures Outlet pressure range 150 1750 cfm (4.2 49.6 m 3 /min): 50 195 psig (3.4 13.2 bar) 2600 5500 cfm (73.6 155.7 m 3 /min): 50 145 psig (3.4 10.0 bar) Consult factory for lower outlet pressures Pressure Regulation +/- 1% at rated flow and pressure Model Rated CFM @ 100psi Connection Size W x H x D (in) Wt (lbs) SFL-150 150 1-1/2"MNPT 9 x 12 x 8.6 20 SFL-250 250 1-1/2"MNPT 9 x 12 x 8.6 20 SFL-500 500 2"MNPT 18.5CL x 29.5 x 11.75 50 SFL-750 750 3"MNPT 18.5CL x 30 x 12.75 70 SFL-1000 1000 3"MNPT 18.5CL x 30 x 12.75 110 SFL-1500 1500 3"MNPT 18.5CL x 30 x 12.75 125 SFL-1750 1750 4"MNPT 18.5CL x 30 x 12.75 125 SFL-2600 2600 4" Flange 30CL x 33 x 17.25 375 SFL-3500 3500 6" Flange 30CL x 33 x 18.25 375 SFL-5500 5500 6" Flange 30CL x 33 x 18.25 400 Model Rated CFM @ 100psi Connection Size W x H x D (in) Wt (lbs) SFL-150 w/bypass 150 1-1/2"FNPT 34 x 17 x 8.6 65 SFL-250 w/bypass 250 1-1/2" FNPT 34 x 17 x 8.6 65 SFL-500 w/bypass 500 2"FNPT 24.5 x 44.25 x 12.75 107 SFL-750 w/bypass 750 3"FNPT 24.5 x 44.25 x 12.75 127 SFL-1000 w/bypass 1000 3"FNPT 24.5 x 44.25 x 12.75 167 SFL-1500 w/bypass 1500 3"FNPT 24.5 x 44.25 x 12.75 182 SFL-1750 w/bypass 1750 4" Victaulic 18.5CL x 51 x 12.25 205 SFL-2600 w/bypass 2600 4" Flange 30CL x 57 x 17.25 575 SFL-3500 w/bypass 3500 6" Flange 30CL x 51.5 x 18.25 575 SFL-5500 w/bypass 5500 6" Flange 30CL x 51.5 x 18.25 600 Data subject to change without notice. Only Imperial measurements will be provided for pipe sizing. Consult factory for larger size flow controllers. LIT-SAPFL201509-1 Copyright 2015 Sullair, LLC. All rights reserved. Specifications subject to change without notice.