Positive displacement proportioning of two-component epoxy intumescent coatings for passive fire protection

Similar documents
Sizing Pulsation Dampeners Is Critical to Effectiveness

Moving Fluids Concept and Theory

WARNING: READ THE GENERAL INFORMATION MANUAL INCLUDED FOR OPERATING AND SAFETY PRECAUTIONS AND OTHER IMPORTANT INFORMATION.

COATINGS SPRAY GUIDE Fast Set Urethane 530

Lesson 6: Flow Control Valves

Spray Gun 134-A. 1 Liter High- Pressure Gel Coat. Usage Instructions & Parts List

Drilling Efficiency Utilizing Coriolis Flow Technology

SEMI FIXED/PORTABLE LINE PROPORTIONERS SLP NPR270

Maxi-Flo System DESCRIPTION SYSTEM OPERATION

Time Pressure Dispensing

Standard Operating and Maintenance Instructions for Pumping System Model PS-150

ELASTOMER PROCESSING

COATINGS SPRAY GUIDE Urethane 520

LINE PROPORTIONERS LP NPR260 Approvals: UL, ULC

DESIGN DATA A WET PIPE BLADDER TANK FOAM/WATER SYSTEM WITH HYDRAULICALLY ACTUATED DELUGE CONCENTRATE CONTROL VALVE

TECHNICAL DATA. than the water inlet pressure to the concentrate

OPERATION MANUAL NTF-60 Plus

Hydronic Systems Balance

DESIGN DATA OBSOLETE. C. Inspections - It is imperative that the system be inspected and tested on a regular basis. See Inspection

Cable Pressurization Buffering

PULSATION DAMPENER / SUPPRESSOR SERIES PDS PROVIDES MULTIPLE SYSTEM SAFEGUARDS

Gerald D. Anderson. Education Technical Specialist

PK-2D Service Manual

Compiled by: B Beard. Approved by: SH Carstens. Description of requirements and procedures for compact provers to be used as verification standards.

Foam Mixers & Proportioning Systems

Pressure on Demand. Air Pressure Amplifiers

TECHNICAL DATA. Low-Flow Foam Preaction System with Hydraulically Actuated Concentrate Control Valve.

SABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company

CHAPTER 3 : AIR COMPRESSOR

Standard Operating and Maintenance Instructions for Pumping System Model PS-90

ICYNENE INSTALLATION INSTRUCTIONS

FM Approved - Automatic Water Control Valve as standard deluge valve. No formal approval available for coating. Foam Concentrate

Epoxy Non-chromate Corrosion Inhibiting Primer. Alumigrip 4101P001 Alumigrip 4901 (CS4901) AkzoNobel Aerospace Coatings. Bombardier Hawker Beechcraft

Best Practices Pneumatics Machine & Design. Written by Richard F. Bullers, CFPPS as published in Fluid Power Journal, July/August 2016

Vehicle-mounted meters, pump supplied

Practical Guide. By Steven T. Taylor, P.E., Member ASHRAE

1.2 Example 1: A simple hydraulic system

FOAM TANK (1/2) DATA SHEET

Hydra-Mate. Instructions M EN. Variable Ratio Proportioner 3000 psi (21 MPa, 207 bar) Maximum Working Pressure

OPERATION MANUAL NTF-15

Air Operated Hydraulic Pumping Systems to 50,000 psi

L 100. Bubble-Tube Level System. Installation, Operation and Maintenance Instructions

A E R O S PA C E M E D I C A L

Constant Pressure Inlet (CCN) Operator Manual

A New Way to Handle Changing Fluid Viscosity and the Full-to-empty Effect

FOAM TANK (1/2) DATA SHEET

Model 7989T Steel Pipe Squeezer Sch. 40 & Sch. 80. Operations Manual

DS/PI-14 DIAPHRAGM SEAL TEMPERATURE ERROR

Inflatable Packer Single & Double. Single & Double Packer Dimension. Wireline Packer. Water Testing Packer (WTP) Packer

Instructions Parts List

ONSITE PROVING OF GAS TURBINE METERS Daniel J. Rudroff Invensys Metering Systems

Copyright, 2005 GPM Hydraulic Consulting, Inc.

TECHNICAL DATA Q= C. Table 1 - Specifications

DISPENSING VALVE MODEL VDP100 INSTRUCTION MANUAL

Potter Nitrogen Generators

Fail Operational Controls for an Independent Metering Valve

STANDARD FOR CONTROL VALVE SEAT LEAKAGE

ENSURING AN ACCURATE RESULT IN AN ANALYTICAL INSTRUMENTATION SYSTEM PART 1: UNDERSTANDING AND MEASURING TIME DELAY

COATINGS SPRAY GUIDE Acrylics (210, 211, 211HT, and 212)

LPG DRIVER ATTENDED TRANSPORT LOADING

User Manual for the Mars Calibration Bench

GACOFLEX TWO-COMPONENT LIQUID POLYURETHANE SPRAY GUIDE UA-60, U-64, UB-64, UA-7090, U-66

ROYTRONIC EXCEL TM Series AD Electronic Metering Pumps

BACK PRESSURE / SUSTAINING

Wet pipe low flow foam/water system

TANK MANAGER FOR TWO TANKS OPERATING MANUAL. 10/31/11 C-More T6C L color touch panel

Vacuum Bagging Wings Instruction Manual Purdue University

Micro Motion Pressure Drop Testing

OBSOLETE DESIGN DATA. Foam 301a. February 9, 1998

Flow meter. bellow vaporizer. APL valve. Scavenging system

Bubble Tube Installations

Cover Page for Lab Report Group Portion. Pump Performance

!!!! SERVICE MANUAL PRESSURE POT 2 GALLON. Service Manual: LT Washington St 931 Progress Ave., #7

8900 Proportioner. Fixed and Variable Ratio (Configured product offering) 2500 psi (17 MPa, 170 bar) Maximum Working Pressure

RH800 & 2000 BASIC OPERATIONS

SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER

HEATEC TEC-NOTE. Setting Siemens Pressure Transmitter. Used on Heatec Vertical Asphalt Tanks. Publication No , Revised

BACK PRESSURE / SUSTAINING

This portion of the piping tutorial covers control valve sizing, control valves, and the use of nodes.

then the work done is, if the force and the displacement are in opposite directions, then the work done is.

hydro-pac, inc. Low-Pressure Gas Compressors 1500 to 6000 PSI

OPERATING MANUAL LO-CROSS-FLOW CF M

CORESTA RECOMMENDED METHOD N 6

Aerodur 2111 Chrome Free Primer

ProAir Clear LV 2 Pack

Balancing HVAC Hydronic Systems Part 3: Flow Measurement Valves

OBSOLETE. Wet pipe low flow manifold system

OWNER S TECHNICAL MANUAL

Autoclear Superior Pack FOR PROFESSIONAL USE ONLY

TECHNICAL DATA. Table 1 - Specifications

TECHNICAL INFORMATION

2. Determine how the mass transfer rate is affected by gas flow rate and liquid flow rate.

Full Range Pressure Compensating Variable Flow Control

Lab 3 Introduction to Quantitative Analysis: Pumps and Measurements of Flow

VBS-9263 Series. Application. Features. Applicable Literature

SINGLE VALVE WITH LOW-FLOW BYPASS

Bulletin TCR-104 & 109 Filling and adding to the Glycol pressure system

NORMAL OPERATING PROCEDURES Operating Parameter Information

PRESSURISED PAINT CONTAINER

VB-7212 Series. Application. Features. Applicable Literature. 5/8" O.D., 45 SAE Flared Stem Up Open, Two-Way Valves General Instructions

Transcription:

Positive displacement proportioning of two-component epoxy intumescent coatings for passive fire protection WHITE PAPER In today s protective coating industry, there is a growing demand to proportion and spray 100% solids coatings that are high viscosity and composed of materials that make them compressible during processing. Epoxy intumescent fireproofing is one such material that starts as somewhat compressible in the pail, and becomes more compressible when heated and agitated under air pressure. This can be a problem for a proportioning machine that meters by volume. When using plural component equipment, if a material is compressible, equipment parameters may have an impact on the spray-applied mix ratio. Factors include agitation, feed pressure, spray pressure, temperature, material composition and compressibility. These factors are not often understood and for most high solids coatings, compressibility has subtle to no impact. But, when a material is viscous enough to entrap air, equipment design and set-up factors may have an impact on coatings performance and end properties. This paper will explain different portioning technologies that exist and their ability to handle these materials. Positive displacement proportioning by volume For decades the standard method of proportioning and pumping coating materials has been positive displacement pumps. They are ideal because they displace a fixed amount of material on each stroke and handle a variety of materials, including epoxies and urethane coatings. Although the pumps are simple in their operation, there are several things that need to happen correctly to make them accurate in metering applications. First, each metering displacement pump must be fully loaded (Figure 1). If the pump is not fully loaded, it will not displace the correct volume. Figure 1. Fill stroke. Lower ball check is open, piston ball check is closed. The pump must be fully loaded on the up-stroke in a positive displacement pump for metering applications. Green is high pressure, blue is low pressure. AUTHORS: Eric Rennerfeldt and Marty McCormick Graco Inc. 1

Figure 2. Metering by Volume Fluid must be incompressible or fully compressed. The middle picture shows part of the stroke being used to compress the fluid up to outlet pressure. Second, the fluid must be a known volume. This means it is non-compressible or fully compressed (Figure 2). If part of the stroke is used to compress the material, ratio errors may occur. Third, the feed pressure should not exceed 25% of the spray pressure. Two-check pumps depend on significant pressure difference to positively close the ball checks. As the feed pressure approaches the outlet pressure, the ball checks become sluggish and may not close properly, resulting in an incomplete dispense on either stroke (Figure 3). Figure 3. Inlet fluid pressure shouldn t exceed 25% of the outlet pressure to prevent sluggish ball checking in metering applications. Why are compressible materials hard to proportion? For most coating applications, the coating materials are low enough in viscosity and the chemical make-up is such that the material will not entrap enough air when it is heated and mixed to become compressible. It is rare that it becomes a topic of discussion or concern. Some materials such as intumescent epoxy coatings are solvent-free and may contain small fibers and other components that make them thick enough to entrap air. It has been demonstrated that some of these materials are compressible directly from the five-gallon (20 liter) pails. When handling intumescent epoxy materials, shovel-style ram pumps are required just to load the material from the pails into heated pressure tanks. At ambient temperatures, the materials are too thick to pour from the pails. In order to condition the material to properly feed the metering pump, the material must be both heated and agitated under pressure (see Figure 4). 2

Figure 4. Material feeds from ram pumps into a heated, agitated, pressurized tank for conditioning. This process is necessary for metering and spraying without interruptions, even when changing pails. The compressibility of these materials when heated and agitated under pressure can easily be shown by measuring the level in the tank when air pressure is changed. Test results indicate that the material volume in the tank can change by as much as five gallons (20 liters) when compressed from 0 to 80 psi (0 to 5.5 bar) (see Figure 5). This can pose a potential problem in metering applications because the volume dispensed on each stroke of a metering pump can change if the tank pressure is manually tweaked or changed. 3

How do compressible materials affect mechanically linked proportioners? On mechanically linked or fixed or variable ratio proportioners, ratio is determined by linking fixed volumetric strokes proportionally between the A and B (see Figure 7). This has been, and will continue to be, a very useful method for proportioning materials in the protective coatings industry. On these systems the assumption is that there is full displacement on each metering pump regardless of diving or compressibility. In reality, the effective stroke can be different between A and B, and the mix ratio is not consistent. When mechanically linked systems are used on compressible fluids, it is common that very specific instructions are needed on the tank pressure settings and temperature settings to make the system perform as well as the technology allows; however, the compressibility between A and B, with all variables taken into account, is unpredictable. An indication that compressibility is changing active spray ratio may be that the A and B fluid pressure gauges don t react together at the top change-over, however, the fluid outlet hoses often dampen the pressure gauges so that they appear normal. Figure 5. Chart reads gallons of resin as feed tank pressure increases. After being agitated under pressure, the level of material in the tank can change by over five gallons after air is mixed in under pressure. The change in fluid volume is a result of the compression of the air which has been mixed in with the fluid. 4

How much pressure is required to compress air? Figure 4 shows that the material is compressed both in the pressure tank and also in the metering pump. Ideally, all of the entrapped air would be fully compressed prior to the metering pump, but this is not possible since the inlet feed pressure must remain below 25% of the outlet pressure in order for proper checking of the metering pump. Feed tank pressure minus the pressure drop of flowing into the pump leaves an unpredictable yet significant amount of compression to happen in the metering pump before the fluid gets up to outlet spray pressure. This compression can steal a significant portion of the displacement stroke before attaining outlet spray pressure. This compression does not happen equally or predictably between the A pump and B pump. Over 700 psi (48 bar) of pressure is required before air is compressed to under 2% of atmospheric volume (see Figure 6). Figure 6. Percent of air volume left from atmospheric pressure as gauge pressure is increased. Based on standard volumetric compression of air under pressure according to Boyle s Law. 5

Ratio checking and spray process using mechanically linked proportioners The ratio checking process for mechanically linked ratio equipment when handling epoxy fireproofing materials has been defined for decades as measuring the volume of A and B fluid dispensed at low pressure at the outlet of A and B fluid hoses. The application of epoxy fireproofing is one of the only applications that require this method of checking prior to each spray period. Most of the time, with incompressible materials, the pressures of A and B are monitored and since the materials are not compressible, it is a very good indicator of a balanced, on-ratio system. With epoxy intumescent materials, ratio checks are not always accurate and can be tweaked by modifying pressures and temperatures during the checking process. The checks are also taken at low pressure out of the hoses and the metering pumps no longer have high outlet pressure to work against. This slows the action of the pump ball checks and steals even more stroke. Temperatures are tweaked to adjust viscosity and this adds or subtracts pressure drop when the pump is loading. Tank pressures are tweaked to adjust flow through the sluggish ball checks lower on one tank and higher on the other to dial in the ratio check. If the tank pressure is lowered to dial in a ratio check, it leaves even more compression that needs to happen in the displacement pump while spraying. All of these adjustments to dial in ratio checks have an unknown effect on the ratio while running at spray pressures. The machine is spraying at an unknown ratio. Benefits of dosing technology How does it cope with compressibility? A new method of proportioning within the past five years is continuous injection dosing. It is a technology that is also based on positive displacement, but with the use of linear position sensors and pressure sensors on each metering pump. These linear sensors measure displacement, and metering valves open and close to control the ratio (see Figure 8). The main difference is that the A and B pumps run independently of each other (not mechanically linked) and cavitation or dive on one pump doesn t affect the other pump. Since the pumps are not linked, each pump can fully compress the material and the system can count the material after the fluid has been pressurized to near spray pressure. The control knows the exact volume per micro inch of rod movement and has the capability to measure actual displacement on each pump and subtract the portion of the stroke that is used to compress the material. Accurate ratio is a result of knowing the actual output of each pump at spray pressure. A Lower B Lower Figure 7. Fixed ratio (mechanically linked) proportioner. For 1:1, there are often two lowers. For odd-ratios, three lowers are common. A B A 6

Ratio assurance using dosing proportioners Ratio checking on dosing proportioners is often unnecessary since the system has built-in ratio assurance, but it is easily done. To account for compressibility, the ratio checks are taken at a minimum of 2500 psi (172 bar). This assures that the fluids are fully compressed at or near spray pressure. The ratio is not affected by how much air has been mixed into the fluid from the supply system. The ratio check is also performed right at the machine outlets, which eliminates errors due to hose expansion. Changing a parameter such as temperature or tank pressure does not have significant effect on the spray ratio or the ratio check samples. Systems will provide the same spray ratio unless they are adjusted beyond the point of the system s ability to compensate. At this point, the system shuts down to prevent material from being applied to the substrate. High-speed dosing maintains accurate ratio at all times while spraying. The B material injects into the A stream at higher pressure as needed to maintain the exact mix ratio. Because the systems are electronic, more capability is built into the system before each spray period. Pump stall tests are automatic before each spray period to ensure there are no leaks in the system. Figure 8. On dosing proportioners, separate pumps with linear sensors and pressure transducers are used for A and B materials. Metering valves open and close to control ratio. Material can be pre-compressed in each pump before creating the ratio. The electronic controls check to find any leaks in the metering pumps or dosing valves. 7

Summary When handling high viscosity materials for spray applications, such as epoxy fireproofing, there are two basic methods for volumetric proportioning mechanically linked proportioning and dosing proportioning. Material compressibility is often not fully understood, but is a real factor when these materials are sprayed. Epoxy intumescent fireproofing is one of the only plural component applications that requires equipment and applicator certifications. The requirement for certification is an indicator that challenges do exist. Both proportioning methods are used in the industry and real world variables can have unknown or negative impact on spray performance. Dosing proportioners have advanced the method to handle these materials for several reasons. First, the equipment measures displacement accurately despite changes in fluid density, pressure, temperature, flow or viscosity. Secondly, the systems are capable of monitoring all functions including off-ratio material or leaks while spraying, automatic alarm or shut-downs for running out of material, pressures out of range, pump runaway, pump leaks, valve leaks and sensor problems. Dosing proportioners allow for simple ratio and pump tests to verify output by weight. Lastly, data is recorded on flow, pressure, temperature and ratio for all material that is sprayed. Applicators, material suppliers, inspectors and clients should all be aware of the pros and cons of each type of system to verify that materials are being sprayed to manufacturer s specifications and to improve overall quality for these types of applications. Graco XM PFP Plural-Component Sprayers use continuous injection dosing for accurate ratio control. BIOGRAPHY Eric Rennerfeldt is a Product Marketing Manager for the Applied Fluid Technologies Divison of Graco Inc. Marty McCormick is a Principal Engineer for the Applied Fluid Technologies Divison of Graco Inc. For more information, contact us at 1-877-844-7226 or info@graco.com. Visit us at www.graco.com/xmpfp 2014 Graco Inc. 349110 Rev. A 3/14 All written and visual data contained in this document are based on the latest product information available at the time of publication. Graco reserves the right to make changes at any time without notice. All other brand names or marks are used for identification purposes and are trademarks of their respective owners.