MUELLER. A Wall Type. Indicator Post. Reliable Connections. General Information 2. Technical Data/ Dimensions 3. Installation 4-5.

Similar documents
MUELLER A A Non-Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

MUELLER. A A Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

MUELLER. Mega-Lite Drilling Machine. Reliable Connections. table of contents PAGE. Equipment 2. Operating Instructions 3-4. Parts Information 5

MUELLER GAS. No-Blo Operations Using D-5. Drilling Machine. Reliable Connections. General Information 2

MUELLER. Xp, & Lineseal 350 Butterfly Valves

Pressure Dump Valve Service Kit for Series 2300 Units

Pipe Thread Connection 1/2 inch NPT. Friction Loss Refer to Figure 3

SECTION BUTTERFLY VALVES

Installation, Operation and Maintenance Manual for Back Pressure Regulator

Pressure Dump Valve Service Kit for Series 3000 Units

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012

Fisher Lever-Lock Handlever Actuators for POSI-SEAL A81 Rotary Valves

Fisher Lever Lock Handlever Actuators for POSI SEAL A81 Rotary Valves

Model B-1 Pipe Line Strainer 3, 4, 6 & 8 Inch (DN80, DN100, DN150 & DN200) 175 psi (12,1 bar) General Description. Technical Data

Section GATE VALVES

B-Too Drilling and Tapping Machine

Model C Pipe Line Strainer 6, 8 & 10 Inch (DN150, DN200 & DN250) 250 psi (17,2) General Description. Technical Data. Page of 6 MAY, 2006 TFP1644

INSTALLATION & MAINTENANCE INSTRUCTION

ACCESSORY KIT INSTALLATION INSTRUCTIONS

Installation, Operation & Maintenance Manual

Model: 43T. Bermad Pressure Relief Valve

Operation Manual Piston Sensed Gas Pressure Regulators

SERIES 2 RAMP OWNER S MANUAL TOOLS REQUIRED: BEFORE YOU BEGIN... Read and understand these instructions before beginning a ramp setup.

Horizontal Bladder Tanks

Model PIV UL/FM Post Indicator Valve. Maintenance and Operation Manual UL/FM Post Indicator Valve Configuration AWWA C515

KTM OM-2 SPLIT BODY FLOATING BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

BUTTERFLY VALVES Series 800

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

Vertical Bladder Tanks

TECHNICAL DATA. Page 1 of 12

BASIN AND WALL MIXER INSTALLATION INSTRUCTIONS

Bermad Pressure Reducing. Model: 42T

Team Insert Valve Sample Specification The Insert Valve shall conform to the following:

Backboard and Rim Owners Manual

Model MTB-ASME Vertical Bladder Tanks

Universal Elevator Mount Owners Manual Customer Service Center N53 W24700 South Corporate Circle Sussex, WI U.S.A.

U.S. Patent No. 7,922,246. Patents Pending

Model MTB-ASME Horizontal Bladder Tanks

Technical Data. UL Listing is based on the following criteria:

Wellhead Mast. Installation and Operation Guide. Nanometrics Inc. Kanata, Ontario Canada

Model MTB-ASME Vertical Bladder Tanks

IMPORTANT: RECEIVING INSTRUCTIONS:

Propane Conversion Kit Instruction

ROCKSOLID DUAL POST ANCHOR

TECHNICAL DATA. Pressure Regulation 531a. April 24, 2009

End Connection. Thread x Thread N/A N/A N/A N/A Flange x Flange N/A

VERTICAL BLADDER TANK

Installation, operation & maintenance manual - original version

TECHNICAL DATA CAUTION

Pressure Independent Control Series

Operating Procedures for GripTight 15.5 SDR & IPS Test Plugs

BPB26-1 AND SSPB26-1 PATIO BASE INSTALLATION INSTRUCTIONS

CO2 Tank Conversion Kit P.N , P.N , and P.N

3/8" Dr. Air Butterfly Impact Wrench

HP-104 & HP-106 Tapping Machine OPERATIONS MANUAL

DIRECT DRIVE DIXIE DOUBLE SEAMER Model 25D

TECHNICAL DATA CAUTION

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

GILMONT ACCUCAL FLOWMETERS

Un-Pressurized Orefice Fittings FIO EZ. Parts List and Operation Instructions TECHNICAL MANUAL. Dn 2-6 Class Lbs

MEGR-1627 Instruction Manual

// ADapters GUIDelines

HORIZONTAL BLADDER TANK

1200B2 Series Service Regulators. Instruction Manual

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

Installation Instructions

4 IN. BALL LAUNCHER Engine Mounted / PTO Driven

INSTALLATION COMMISSIONING, OPERATION & MAINTENANCE MANUAL

KECKLEY. Installation, Operation, and Maintenance Manual. Style KGV - Knife Gate Valve

I T T Pressure Reducing Valve WARNING INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

LARGE R/W GATE VALVES

INSTALLATION INSTRUCTIONS

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity

Booster Pump PB4-60 Replacement Kits

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

TECHNICAL DATA OBSOLETE

Installation, Operation, and Maintenance Manual

Engineering Data Sheet

safety Shut-Off Valve HON 721

BP48-1 AND SSP48-1 IN-GROUND POST INSTALLATION INSTRUCTIONS

Index Table. Model 794. Installation, Operating and Maintenance Instructions

G92 Series BASOTROL Automatic Pilot Gas Valve

RG1200 Service and Repair Manual

ACCESSORY KIT INSTALLATION MANUAL

AIR/OVER HYDRAULIC JACK 20 TON

Torque Specifications

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

H4802, H4802-1, H , and Pole Tampers

VERSA BIKE RACK INSTRUCTIONS

Lectric Cycles Mid-Drive Electric Motor Installation

Assembly Drawing: W-311B-A01, or as applicable Parts List: W-311B-A01-1, or as applicable Special Tools: , , &

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

Big Ride ASSEMBLY AND INSTALLATION INSTRUCTIONS * * C A U T I O N * *

TBV OPERATION AND MAINTENANCE MANUAL SERIES 2800: FLANGED BALL VALVE. For technical questions, please contact the following:

D05 Pressure Regulating Valves

35 TON HYDRAULIC PUNCH WARNING

Speed control assembly model A-1

64 Series Pressure Reducing Regulators

HUPF Series DESCRIPTION APPLICATION INSTRUCTION SHEET GAS PRESSURE REGULATOR WITH INCORPORATED FILTER EN1C-0003NL05 R1205.

VALVCHEQ BACKFLOW PREVENTERS FIGURE RP03

Transcription:

Installation Instructions manual MUELLER table of contents PAGE A-20814 Wall Type General Information 2 Technical Data/ Dimensions Installation 4-5 Maintenance 6 Parts 7 Indicator Post! WARNING: 1. Read and follow instructions carefully. Proper training and periodic review regarding the use of this equipment is essential to prevent possible serious injury and/or property damage. The instructions contained herein were developed for using this equipment on fittings of Mueller manufacturer only, and may not be applicable for any other use. 2. Do not exceed the pressure ratings of any components or equipment. Exceeding the rated pressure may result in serious injury and/or property damage.. Safety goggles and other appropriate protective gear should be used. Failure to do so could result in serious injury. TM Reliable Connections Customer Service Center Decatur, Illinois 800.42.12 www.muellercompany.com moreinfo@muellercompany.com

General Information overview The Model A-20814 Wall Indicator Posts are designed to operate 4 14 non-rising stem (inside screw) gate valves, which are used to control the water supply to automatic sprinkler, water spray deluge, foam water deluge, or standpipe fire protection systems. They permit operation of valves located immediately inside exterior walls while providing an exterior visual indication as to whether the valves are open or shut, in addition to a means for locking the valves in a particular position. Indicator posts provide for valve operation from outside of the protected property and, therefore, the opportunity for more prompt valve operation in an emergency situation. The A-20814 Posts will accommodate 4 14 size post indicator valves requiring 14 to 4 turns to open and that are listed or approved for fire protection service. Posts are provided standard order for use with left hand opening valves; however, they may be special ordered for use with right hand opening valves or converted in the field for use with a right hand opening valve by changing the left hand opening Cover to a right hand opening Cover. The A-20814 Posts accept direct attachment of a 1 /2 NPT mounting electric supervisory switching device (supplied by customer) which can be used by proprietary and central stations to monitor the open position of the A-20814 Post. The Handwheel is fastened to the Post with an eyebolt so that the Post can be secured in position using a padlock and chain. Approvals and Standards Model A-20814 Indicator Posts are listed by Underwriters Laboratories Inc. (UL) and approved by Factory Mutual Research Corporation.! WARNING: The Model A-20814 Indicator Posts described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the National Fire Protection Association, in addition to the standards of any other authorities having jurisdiction. Failure to do so may impair the integrity of these devices. Padlock & Chain The owner is responsible for maintaining their fire protection system and devices in proper operating condition. The installing contractor or manufacturer should be contacted relative to any questions. Removing or disabling the tamper resistant feature of the special key wrench screw, which is used to secure the cover of the Supervisory Control Valve, will void its listings and approval. typical installation Supervisory Control Valve 2

Technical Data/Dimensions technical data Indicator Posts The A-20814 Post Head is mounted directly to an exterior wall, and it is designed to work with 4 14 PIVs employing 2 operating nuts. The Post Head has /4 clearance holes for the mounting bolts. The A-20814 has a 14 pitch Threaded Sleeve which can readily accommodate field positioning of the OPEN and SHUT Targets for 4 14 PIVs requiring 14 to 4 turns to open. Dimensions Valve Size A turns to Open 4 14.76 10.95 14 6 18.55 14.91 20 1 /2 8 21.97 18.02 26 1 /2 10 25.44 21.62 12 28.4 24.52 8 1 /2 14 2.75 29.1 4 1 /2 Dimensions A & B for Mueller Resilient Wedge Indicator Valves B The A-20814 is provided with an operating stem assembly that can accommodate a range of 28 between the base of the Post Head and the PIV operating nut. The Lower Stem (square tube) is field cut to the desired length. An optional 15 /4 long, 5 steel pipe Sleeve is available for protecting the Stem/ Coupling. Use of the Sleeve is recommended except in the case of sheet metal wall construction. The Sleeve must be field cut to the desired length. Standard Order Posts are factory set with the OPEN and SHUT Targets positioned for use with left hand (counter-clockwise) opening valves. An arrow on the Post Head Cover indicates the left hand direction of opening. The position of the Targets may be reversed in the field, in order to accommodate a right hand opening valve, provided that the Post Head Cover is changed to one indicating right hand opening. The Post Head and Cover are cast iron per ASTM A126 (Grade B). The Lower Stem, Upper Stem, Coupling, and Coupling Insert are carbon steel. The Operating Nut and Handwheel are ductile iron per ASTM A56. The Targets and Threaded Sleeve are nylon and the Cap is polypropylene. The Windows are made from polycarbonate. The Post Head, Cover and Handwheel are painted red. 12 ø (05mm) Flange 18 1 /2 (470mm) 1 /2 (89mm) Field Cut A-20814 indicator posts Nominal Installation dimensions 28 Max (711mm) Min (76mm) A B Sleeve Set Screw 11 /16 (17mm) PIV /4 ø (19mm) Bolt Holes on 10 1 /2 ø (267mm) Bolt Circle 14 ø (56mm) Upper Stem (Square Tube) Cotter Pin Lower Stem (Square Tube) Optional Pipe Sleeve 5 Sch. 10 15 /4 (400mm) Coupling

Installation Installation Instructions The A-20814 Post Targets must be positioned for use with the appropriate number of turns to open the post indicator valve. Improper positioning of the Targets can result in an erroneous indication of the open or shut position of the valve. The A-20814 will accommodate positioning of the Targets to operate PIVs requiring 14 to 4 turns to open. NOTE: The Targets for the A-20814 Indicator Post have been factory set for use with a left hand opening, 4 Mueller PIV. Consequently, Steps 5, 6, 7, and 9 need not be performed when installing the A-20814 Post with a 4 Mueller PIV or with a PIV that requires 14 turns to open. Installing the Post 1. Completely close the PIV. 2. Along the centerline of the PIV make a 5 /4 diameter clearance hole through the wall if the Optional Sleeve is to be used or if the Coupling is to be located within the wall area. A 2 1 /4 diameter clearance hole may be used otherwise.. If it is necessary to protect the Lower Stem Assembly where it passes through the building wall, measure the thickness of the wall and cut the Optional Sleeve to an overall length equal to the wall thickness plus 2 1 /2. Temporarily place the Optional Sleeve into the wall clearance hole. 4. Attach the Coupling to the operating nut of the PIV using the Cotter Pin, and then cut the Lower Stem so that it will extend 1 /2 in front of the wall. 5. Remove the two bolts securing the Cover in place and remove it along with the Upper Stem Assembly from the Post Head. 6. Position the targets (see below). 7. Reinstall the Upper Stem Assembly into the Post Head and resecure the Cover using the two bolts. 8. Slide the Upper Stem into the Lower Stem and center the base of the Post Head over the hole in the wall and fasten it securely to the wall. NOTES: Before mounting the Post Head and if using the Optional Sleeve, loosen the Set Screw, insert the Sleeve into the Post Head, and then tighten the Set Screw. 9. Reinstall the Handwheel if it had been removed. 10. Using the Handwheel, open and close the valve and check to see that the SHUT and OPEN Target Plates are clearly in view in the Windows, at their respective positions and that there is no FOR LEFT HAND OPENING VALVES OPEN TARGET: Top surface of threaded flange aligned with Mueller Valve size mark (10 Valve shown) OR set to Dimension X (see note 2). X SHUT TARGET: Top surface of threaded flange aligned with CT (center top) mark OR bottom surface aligned with CB (center bottom) mark (see note 1). feeling of binding of the Upper and Lower Stem Assemblies. It is recommended that the turns to open/ close be counted and compared to the valve manufacturer s specification, in order to verify full valve opening. NOTES: If there is any indication of binding of the internal operating parts, alignment of the Indicator Post must be corrected. If the Targets are not properly in view, completely close the PIV, remove the Post Head from the wall, remove the Optional Sleeve from the Post Head if applicable, and then repeat Steps 5 10. 11. Tighten the switch mounting hole plug if Supervisory Control Valve is not to be immediately attached. FOR RIGHT HAND OPENING VALVES positioning of targets SHUT TARGET: Top surface of threaded flange aligned with CT (center top) mark OR bottom surface aligned with CB (center bottom) mark (see note 1). X OPEN TARGET: Top surface of threaded flange aligned with Mueller Valve size mark (10 Valve shown) OR set to Dimension X (see note 2). NOTES: 1. Set shut Target first. 2. For valves manufactured by other than Mueller Co., set to dimension x calculated as follows: No. Of turns to open valve X in inches = 14 4

Installation 12. Install the Supervisory Control Valve (supplied by customer) a) Remove the Cover from the assembly, and then loosen the Trip Rod Screw. Adjust the position of the Trip Rod so that it extends about 1 /8 beyond the Nipple, and then securely tighten the Trip Rod Locking Screw. b) Rotate the Handwheel until the valve is fully open. Note the position of one of the OPEN Targets in its Window. c) Rotate the Handwheel until the OPEN Targets are out of the Post Windows. Note the direction in which the OPEN Target will move when it is returned to the Post Window. d) Remove the Nipple from the assembly, and then with the Locknut screwed over the Nipple threads, hand tighten the Nipple into the 1 /2 NPT hole provided in the Post Head, and then tighten the Locknut against the Post Head to secure the Nipple firmly in place. e) Refer to Positioning of Targets (pg. 4) as appropriate, and note the direction in which the Trip Rod must move when the OPEN Target is returned to the Post Window. Slide the assembly as far as possible onto the Nipple while maintaining proper orientation of the assembly, and then tighten the Set Screw that holds the assembly onto the Nipple. f) Attach leads from an electrical continuity meter to the appropriate terminals. g) Return the valve to its fully open position. Verify that the OPEN Target returns to the position noted in Step b. Also, verify that the contacts change position within two turns of the valve being fully open. h) Begin to return the valve to its closed position. Verify that the contacts change back to their original position within two turns from full open. NOTE: If the Upper Stem Assembly binds before the OPEN Target reaches its full open position, or the switch contacts do not change position as described in Steps g and h, then the Targets must be readjusted. If the Targets require readjustment, close the PIV, remove the Post Head from the wall, remove the Optional Sleeve from the Post Head if applicable, and then repeat Left-Hand Opening Valve is Shut by Turning Handwheel to the Right (Clockwise) Right-Hand Opening Valve is Shut by Turning Handwheel to the Left (Counter-clockwise) Steps 5 10; however when positioning the Targets, rotate both Targets at the same time as necessary so that the OPEN target will trip the Actuator Rod of the. Repositioning of the OPEN and SHUT Targets relative to each other should not be necessary. Repeat Steps b h. i) Remove the electrical continuity test leads. The external field wiring connections can now be made to the. NOTE: Use of a weathertight conduit connector with a gasket seal is recommended. Attachment of Supervisory Control Valve Target Trip Rail Targets Move Towards Handwheel As Valve Is Shut Actuator Rod Targets Move Towards Wall As Valve Is Shut Actuator Rod Target Trip Rail 5

Maintenance Care and Maintenance The Model A-20814 Indicator Post does not require any regular schedule maintenance. It is recommended that Indicator Posts used to operate fire protection system water control valves be locked in the fully-open position using the Handwheel as shown on page 2. The locks must be sturdy and resistant to breakage except by heavy bolt cutters. It is also recommended that once a month a visual inspection procedure be followed, with the following items checked: 1. The Post Head, Handwheel, and Windows have not been damaged. 2. The Targets indicate that the valve is open.. The Post is properly locked in the open position. In addition, on a quarterly basis, the Indicator Post should be closed two turns and then reopened tight to verify that the PIV is in the full open position and properly engages with the Post and, that the Supervisory contacts (if applicable) properly change position. Any damaged parts must be immediately replaced. The Indicator Post should also be physically tried to be sure that the valve is in the fully-open position, if there are any damaged parts, sign of tampering, or the position of the valve is questionable. NOTE: Before closing a fire protection system main valve for maintenance work on either the Indicator Post or fire protection systems which it controls, permission to shut down the affected fire protection systems must first be obtained from the proper authorities and all personnel who may be affected by this decision must be notified. It is recommended that fire protection systems be inspected by a qualified Inspection Service. 6

Parts 18 16 22 21 17 15 9 1 10 11 24 14 20 19 1 Use to Secure Coupling to piv Operating Nut 8 6 25 26 4 2 7 5 ID PART NAME 1 Post Head 2 Eye Bolt Hex Nut, 5 /8 4 Flat Washer, 5 /8 5 Lower Stem 6 Coupling 7 Coupling insert 8 Cotter Pin, 1 /4 x (2 req d) 9 Hex Socket Set Screw, /4-10 UNC x 1 10 Pipe Plug, 1 /2 NPT 11 Window (2 req d) 1 Handwheel 14 Operating Nut 15 Spring Pin, 1 /8 x 2 1 /4 16 Coupling Pin, 1 /8 x 1 1 /2 17 Threaded Sleeve 18 Upper Stem 19 Cap 20 Retaining Ring 21 OPEN Target 22 SHUT Target 24 Wall Mount Indicator Post Cover 25 Hex Nut, 1 /2 26 Hex Bolt, 1 /2 x 1 /4 Replacement parts Specify Description & Part No. 1. Post Head... 240556 2. Eye Bolt...198585. Hex Nut, 5 /8 11 UNC...19099 4. Flat Washer, 5 /8...197688 5-8. Lower Stem Assembly...287084 9. Hex Socket Set Screw, /4 10 UNC x 1...198428 10. Pipe Plug 1 /2 NPT...198582 11. Window...148790 1. Handwheel... 148767-1 14-18. Upper Stem Assembly...28708 19. Cap...29014 20. Retaining Ring...290157 21. OPEN Target...290144 22. SHUT Target...290145 24. Wall Mount Indicator Post Cover Open Left... 240554-1 Open Right... 240555-1 25. Hex Nut, 1 /2...19149 26. Hex Bolt, 1 /2 x 1 /4...450 7

TM Reliable Connections Water (U.S.) 1.800.42.12 www.muellercompany.com moreinfo@muellercompany.com Water (Canada) 1.705.719.9965 www.muellercanada.com more-info@muellercanada.com Form 12541-10/17 Copyright 2016 Mueller Co., LLC. All Rights Reserved. The trademarks, logos and service marks displayed in this document herein are the property of Mueller Co., LLC, its affiliates or other third parties. Products marked with a section symbol ( ) are subject to patents or patent applications. For details, visit www.mwppat.com. These products are intended for use in potable water applications. Please contact your Mueller Sales or Customer Service Representative concerning any other application(s).