SAFE WORK METHOD STATEMENTS

List all key terms and acronyms used in the procedure, and their definitions.

Confined Spaces. This procedure applies to all workers of the Diocese of Maitland Newcastle (DoMN).

Safe Work Method Statement

Field Instruction. The purpose of this instruction is to inform all Horizon Power workers of the safety requirements when working from a EWP.

Course outline: 111 WH&S E101A UEENEEE101A - Occupational Health and Safety regulations, codes and practices in the workplace

Temporary load-bearing support for structural alterations or repairs

CONTRACTOR SAFETY INDUCTION HANDBOOK

Safe Work Method Statement

SAFE WORK METHOD STATEMENT WORKING IN CONFINED SPACE HSE NET NAT SWMS APAND00030

SAFE WORK METHOD STATEMENT Part 1

Safety Checklist for Events Held at Hillbrook

Safe Work Method Statement (SWMS)

Safe Work Method Statement

How severely could the risk hurt someone? Low/Insignificant First aid

Electricity Hazard Guide

THE CONTROLLED COPY OF THIS DOCUMENT IS ON THE COMPUTER NETWORK PRINTED COPIES ARE ONLY CURRENT FOR THE DATE AT THE BOTTOM OF THE PAGE.

Construction & Building Industry Safety Guideline. Electrical Isolations

CONTRACTOR WHS HAZARD STANDARD CONFINED SPACE EXTERNAL USE ONLY

WINDMILL (pre-start) HAZARD INSPECTION CHECKLIST

Safe Work Method Statement

SCOPE OF WORK, SAFETY METHOD STATEMENT & RISK ASSESSMENT

WORK METHOD STATEMENT STRUCTURAL STEEL

SH&E Work Method Statement Concrete Cutting & Drilling Fast Cut Qld Pty Ltd, 91 Basalt, GEEBUNG PH M ABN

ASC Confined Space Refresher

WHS PROCEDURE P Confined Spaces. Approved by: Ruth Hampton Review Date: 6 th December 2015

SAFE WORK METHOD STATEMENT Part B

WORK METHOD STATEMENT ELECTRICAL

Permit-To-Work Guidance and Templates

Lifting Operation & Lifting Equipment Procedure

We take safety very personally at Aurecon. Safety is everybody s business, every day. Health and safety incidents are not inevitable, they are

UETTDRRF06B PERFORM RESCUE FROM A LIVE LV PANEL LEARNER GUIDE

Field Instruction. This instruction outlines the minimum requirements for all Horizon Power workers who undertake Vegetation Management Work.

Policy Redesign Project. Plant Safety Policy. Table of Contents

WORK METHOD STATEMENT CARPET LAYING

SOP. Working in Confined Spaces

RISK ASSESSMENT Installation of electrically operated service lifts (non passenger type)

Safe Work Method Statement

How severely could the risk hurt someone?

How severely could the risk hurt someone? Low/Insignificant First aid

SAFE WORK METHOD STATEMENT CARPENTER

NZQA expiring unit standard version 6 Page 1 of 5. Demonstrate knowledge of electrical safety and safe working practices for electrical workers

Work Activity (e.g. Road Work): Work Location:.

PLANNED LIGHTING MAINTENANCE LTD METHOD STATEMENT & RISK ASSESSMENT REPLACEMENT OF LAMPS OR REPAIRS TO HIGH LEVEL LIGHT UNITS

PLANNED LIGHTING MAINTENANCE LTD METHOD STATEMENT & RISK ASSESSMENT REPLACEMENT OF LAMPS OR REPAIRS TO LOW LEVEL LIGHT UNITS

Contractor OHS Induction. AOHS-05-GUI September 2016

ISOLATION ISSUE 2 1 AIM 2 4 REASONS FOR INCLUSION 3 6 PLANT AND EQUIPMENT REQUIREMENTS 3 7 SYSTEM & PROCEDURAL REQUIREMENTS 4 8 PEOPLE REQUIREMENTS 6

Safe Work Procedure for installation of external cladding

Competency type. positions. All workers (including contractors), higher degree students and volunteers

LADDERS FIXED AND PORTABLE

Application of rope access methods in the construction, inspection, repair and maintenance of wind turbines

Appendix 4C - Sample SWMS Trenching

ASPEC Engineering HSE Management System. Work Instruction. 1 Objective. 2 Working in confined spaces. 2.1 What is a confined space?

Procedure: Permit Activities-Work in Confined Spaces and Hot Works

ELECTRICAL (COMPREHENSIVE) SAFETY PROGRAM REGULATORY STANDARD: OSHA - 29 CFR CFR , ,

Building 9 Roof Safety Assessment

How severely could the risk hurt someone? Low/Insignificant First aid

SCHNEIDER AUTOMATIC CIRCUIT RECLOSER JOB SAFETY ANALYSIS

SAFE WORK METHOD STATEMENT

Building 43 Roof Safety Assessment

Isolation Lockout and Tagging

PRO Lifting Operations

SAFE WORK METHOD STATEMENT

Telco Antennas SWMS Working At Height Above 2m

Working at Height - MEWPS & Ladders. Your company details Address Tel: Fax: Mobile:

Section J. How to develop safety elements for project safety management system. How to develop safety elements for project SMS

Specific Safety Legislation/Codes of Practice/Australian Standards applicable to this JSA (Tick those applicable).

SAFE WORK METHOD STATEMENT

Safety Essentials. Mandatory rules for our high risk activities

This policy and associated Event Safety Checklist apply to all events held at any of Arts Centre Melbourne s venues.

Electrical Safety. Hazard Awareness

SAFE WORK METHOD STATEMENT Part 1. Company Details. Company Name: Contact Name, Position and Phone number: Address: Project details.

Hampstead Hill School Health and Safety Policy: Confined Spaces

Method Statement Author

Harbour Town Gold Coast Site Induction

Job Safety and Environmental Analysis (JSEA)/Safe Work Method Statement (SWMS)

First Aid Courses TELEPHONE ORDERS & ENQUIRIES ER 24 Pty Ltd Suite of Courses as a Registered Training Organisation Co-Provider

LEVEL 2 CERTIFICATE OF COMPETENCE IN THE SAFE USE AND OPERATION OF MOBILE ELEVATED WORK PLATFORMS

WHS OHS HAZARD REGISTER (SITE AND OFFICE OPERATIONS)

SH&E Work Method Statement Concrete Cutting & Drilling Fast Cut Qld Pty Ltd, 91 Basalt St, GEEBUNG QLD 4031 ph ABN:

Develop and sign off on risk assessment/work method statement for the task, considering task specifics elements that will affect the user s safety:

Health & Safety Contractor rules

SAFE WORK METHOD STATEMENT SWMS No Version

SCOUTS AUSTRALIA NSW

Contractor/Visitor Safety Orientation UNBC

The definition of a competent person given in the Electricity at Work Regulations 1989 (EWR) is as follows:

SUBJECT: LIFTING OPERATIONS AND LIFTING EQUIPMENT (LOLER)

Safe Work Method Statement (SWMS)

Procedure. Work Health and Safety Electrical Safety. Document number: PRO-00006

Occupational Health & Safety Event Safety Checklist

Contractor Hazard Identification and Control Guide

Building 21 Roof Safety Assessment. Multi Story Building with large metal roof areas Exteral access required for window cleaning UOW01613

Building 32A Roof Safety Assessment

SH&EWMS No.: F-C-QLD-10 Revision Date: July 2018 Revision Due: July 2019

Company Health and Safety Policy

Document Control Summary Status: Replacement for Electricity High Voltage SOP v1.0 Version: V1.1 Date: July 2017 Author/Title: Owner/Title:

The Sample Company Pty Ltd

Transcription:

Samark North Qld Pty Ltd SWMS Manual SWMS No 007 Samark North Qld Pty Ltd ABN : 99 082 958 487 Electrical Contractors License C37121 Page 2 of 6 Safe Work Method Statement Title: SWMS:007 WORKING ON ENERGISED LOW VOLTAGE EQUIPMENT / APPARATUS Work Method / Task Description Hazard Identification Level Recommended Actions / Controls for Prevention P.P.E. Residual Confirm the requirements regarding work on energised equipment and apparatus. Obtain work approval and confirm any client site/safety instruction. Check scope of works to confirm whether work be re-scheduled so it may be isolated? Safe Work Methods Confirm with client that works meet the requirements regarding work on energised equipment and apparatus and the risk of harm would be greater if the circuits were de-energised before work commenced. Confirm that person/s carrying out the work are appropriately qualified, competent, confident and trained for the task. Client Name Client Authorisation Safe Work Methods Follow Safety Procedure Carry out Level in respect of the works to be carried out. Confirm appropriate test equipment, tools, barriers, accessories, clothing, personal protective equipment (PPE), working kit are used and maintained, and first check operation of test apparatus. Version 2.1 01/03/2017 Review Date 01/03/2018

Samark North Qld Pty Ltd SWMS Manual SWMS No 007 Samark North Qld Pty Ltd ABN : 99 082 958 487 Electrical Contractors License C37121 Page 3 of 6 Safe Work Method Statement Title: SWMS:007 WORKING ON ENERGISED LOW VOLTAGE EQUIPMENT / APPARATUS Work Method / Task Description Hazard Identification Level Recommended Actions / Controls for Prevention P.P.E. Residual Confirm you have a safety observer who is competent to perform the task being observed and is also competent in electrical rescue and cardio-pulmonary resuscitation (CPR). Clearly Identify the isolation point and the entry/exits are clear of obstructions with barriers/ropes/signage installed to prevent unauthorised entry. Working persons shall confirm rescue procedures and have attended confined space rescue training. Carry out scope of works provided you have an appropriate safe system of work and you are confident. Test and commission new works and reinstall covers. Clean work area, remove and pack away equipment. Complete appropriate documentation (switchboard schedules, update drawings and work book). Electric Shock Electric Shock 1 3 1 3 3 Use Hand Tools in Correct Fashion Use Hand Tools in Correct Fashion 9 9 9 2 4 2 4 4 Version 2.1 01/03/2017 Review Date 01/03/2018

Samark North Qld Pty Ltd SWMS Manual SWMS No 007 Samark North Qld Pty Ltd ABN : 99 082 958 487 Electrical Contractors License C37121 Page 4 of 6 Safe Work Method Statement Title: SWMS:007 WORKING ON ENERGISED LOW VOLTAGE EQUIPMENT / APPARATUS Personnel Qualifications and Experience Required Personnel Duties and Responsibilities Training Required to Complete Work Must be a licensed electrician. Electrician to carry out daily inspections of work site for hazards. Electrician to be trained in hazard identification, Level and control. Appropriate industry induction. All personnel to maintain tidy work site. Electrician to be certified as a qualified Electrical Supervisor. Previous experience required. Safety observer who is competent to perform the task being observed and is also competent in electrical rescue and cardio-pulmonary resuscitation (CPR). Engineering Details / Certificates / WorkCover Approvals / Australian Referenced Codes of Practice / Regulations / Legislation Standards Installation to be in accordance with AS 3000 Standards and client's specifications. Work Health and Safety Act and Regulations 2011, Electrical Safety Act 2002 and Regulations 2013, Electrical Safety Code of Practice 2010, Hazardous Manual Tasks Code of Practice 2010, Plant Code of Practice 2005, Mobile Crane COP 2006, Industry Standard for Electrical Installations on Construction Sites 2010. Plant / Equipment Required (Mobile or Static) Portable hand tools, electrical power tools, drills, leads and ladders. Hazard Identification to be conducted for plant used e.g. Scissor lift, boom lift, cherry picker mechanical handling equipment, appropriate test equipment, barriers, clothing, personal protective equipment (PPE), Insulated tools and mats, and pre-checked test equipment. Persons responsible for ensuring compliance with this SWMS Maintenance Checks / Calibration Intervals Hand tools and ladders to be checked daily. Elevated Work Platform/s in accordance with manufacturer s recommendations. 1. Mark McDonald 2. Austin Wilds P P E 1 2 3 4 5 6 7 8 9 10 11 12 13 Version 2.1 01/03/2017 Review Date 01/03/2018