T EK-COR 1100A. Coriolis Mass Flowmeter. FLOW. Technology Solutions

Similar documents
TEK-THERMAL 1700B. Thermal Mass Flowmeter. FLOW. Technology Solutions

T EK-COR 1100A Coriolis Mass Flowmeter

TekValSys MP. Multi Phase Separator. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys TEKVALSYS

TEK-SUB 4800B. Submersible Level Transmitter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys LEVEL

TEK-M ANIFOLD 7500A. Manifolds. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys ACCESSORIES

Coriolis Mass Flow Meter

T EK-SUB 4800C 19 mm Submersible Level Transmitter

C-Flow Coriolis Mass Flow Meters

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

analytical bulk flow distance FLOW level pressure temperature industrial communication

Integral type Differential pressure flowmeter VNT Series

Truck-mounted Mass Flow Metering for LPG Delivery

Varea-Meter Flowmeters. For Metering and Controlling Flows of Process Fluids

New! ProFlow. Sliding Vane Meters DN (½ - 2 ) _ 142. Product Bulletin

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

NEW VERSAFLOW CORIOLIS

Shanghai AEAD Technology Co., Ltd Professional Manufacturer of Flow, Level, Pressure, Temperature

COMPAFLOW. Compressed Air. Volumetric flow. Gas. Mass flow. Steam. Net volumetric flow. Liquid

Technology Solutions Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys

Technical Data Sheet. OPTIMASS 7000 Custody Transfer Mass Flowmeter

Vortex flowmeters. Product family introduction Principle of operation Product review Applications Key product features

CORI-FLOW PRECISION MASS FLOW METER / CONTROLLER FOR LIQUIDS AND GASES

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

TRZ 03-K Volumeter. Proven Technology. Superior Performance. TRZ 03-K Volumeter is a Turbine Gas Flowmeter for Secondary Gas Metering.

For Multi-Parameter Meters see mvx

VersaFlow Vortex 100 Vortex Flow Meter Technical Datasheet. Specification. The all-in-one solution. Highlights. Industries.

For Multi-Parameter Meters see mvx

Pro-V Multivariable Flowmeter

Torque Tube TB300 Digital Transmitters

Features. Description

Vortex Flow Meter Wafer or Flange Connection. - Steam - Liquid - Gas

LUGB Vortex Flowmeter

ABB MEASUREMENT & ANALYTICS DATA SHEET. WaterMaster FEW530 Electromagnetic water meter

Differential Pressure Transmiter

ACCURACY, PERFORMANCE, AND HANDLING OF OIL-FILLED DIGIQUARTZ PRESSURE INSTRUMENTATION

Over 20,000 Strain Gage Target flowmeters installed since 1952.

An Overview of a Market Research Study on the Worldwide Coriolis Flowmeter Market

Level switches Series LD Vibrating fork level switch for liquids and solids

PanaFlow MV82. Insertion Style Multivariable Flowmeter. GE Measurement & Control. Key Benefits. Applications

Level switches Series LD Vibrating fork level switch for liquids and solids

RCD - Ultra-Rugged Differential Pressure Flowmeter

Flowatch Multiphase Flow Meter

T EK-THERMAL 1700B Thermal Mass Flowmeter

Precision Mass Flow Meters / Controllers for Liquids and Gases

Flow metering in gases Introduction to COMBIMASS family

Variable Area Flow Meters

deltaflowc deltaflowc Venturi or Probe

GPE Inc. Golden promise equipment Inc.

Pressure measurement is a family affair

TransPort PT878GC Panametrics Ultrasonic Portable Gas Flowmeter. GE Infrastructure Sensing. Features. Applications

Level MEASUREMENT 1/2016

Bubble Tube Installations

Best Practices for Installation of Gaseous Sample Pumps

7000 Series OPTIMASS Mass Flowmeters. Titanium Hastelloy Stainless Steel

Wafer type. the product

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Orifice Plate Flow Meter

Micro Motion 7835 Series Density and Concentration Meters

THERMAL MASS FLOW MEASUREMENT FOR GASES

Target disk flowmeter Series DP. Instructions manual DP65 DP500. R-MI-DP Rev.: 4 English version

Drilling Efficiency Utilizing Coriolis Flow Technology

TransPort PT878GC Panametrics Portable Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features

Mass Flow Controller (MFC) for Gases

High-performance submersible pressure transmitter For level measurement Model LH-10

Micro Motion 3098 Gas Specific Gravity Meter

2600T Series Pressure Transmitter Models 264DC Differential and 264HC Gage Level Transmitters. Kent-Taylor

High-performance submersible pressure transmitter For level measurement Model LH-10

Smart Differential Pressure Transmitters. Instruction Manual

CoriolisMaster mass flowmeter Diagnostics, verification and proof test

Micro Motion 7812 Fiscal Gas Density Meter

SITRANS P measuring instruments for pressure

Level transmitters and indicators Series LU Ultrasonic level transmitter and indicator for liquids and solids

Online data sheet FLOWSIC30 GAS FLOW METERS

Ultrasonic Flowmeter USZ 08

SCOPE OF THIS GUIDE STARTING-UP. 1 Check mini CORI-FLOW functional properties

FAS-W. Features. Applications. Automatic condensation hygrometer

SITRANS F I Gardex. Flowmeter. SITRANS F I Intra/Prima. Flap Flowmeter. Contents. English. General 1. SITRANS F I Gardex 2. SITRANS F I Intra/Prima 3

SITRANS F C. Flow sensor SITRANS FCS400 3/157. At ordering the following fraction or standard density scales can be specified: Overview

Pressure & Vacuum Measurement. Series 370. Solutions. Stabil-Ion Vacuum gauge and Controller

Exercise 5-2. Bubblers EXERCISE OBJECTIVE DISCUSSION OUTLINE. Bubblers DISCUSSION. Learn to measure the level in a vessel using a bubbler.

mass flowmeter approved by Weights and Measures for custody transfer

L 100. Bubble-Tube Level System. Installation, Operation and Maintenance Instructions

Installation, operating and maintenance Instructions for Seemag bypass level indicator

COMPANY TRICOR CORIOLIS MASS FLOW METERS

Radar, Ultrasonic and RF Level Transmitters

Flow and Energy Measurement F-5400 THERMAL MASS FLOW METER

The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions

SERIES METAL TUBE VAREA-METER STRAIGHT THROUGH TYPE ROTAMETER

780S Ultra High Purity Series

PHIL JANOSI MSC. International Product Manager, Coriolis Flowmeter KROHNE Ltd, UK.

Ultrasonic level transmitter and indicator

deltaflowc deltaflowc Gas Massflowmeter Venturi- and Probe Type

Mass Flow Meter (MFM) for Gases

Variable Area Flow Meters

Mass Flow Controller (MFC) for Gases

Quick Installation Guide Doc nr.: C Date:

Brooks TMF-Zone 1 Models 5816-Ex/5864-Ex

Design Features. General Description

Model 601CV. Mass Flow Controller. Product Features:

Transcription:

Technology Solutions T EK-COR 1100A Coriolis Mass Flowmeter FLOW www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys

Introduction There can often be more than one type of fluid used in your process, each with different properties. Your process and product quality completely depend on the accuracy with which you measure each of these fluids. Our range of Coriolis mass flowmeters are designed to suit your need to measure almost any fluid across any application. Built on the Coriolis principle, these meters measure the mass of the fluids directly, rather than volume and hence they do not require compensations for factors such as temperature and pressure which impact volume and accuracy of measurement. Measuring Principle The Coriolis measuring principle refers to the effect that a moving mass has on a body in a rotating frame of reference. The moving mass exerts an apparent force on the body, causing a deformation. This force is called the Coriolis force. It does not act directly on the body, but on the motion of the body. This principle is used in Coriolis flowmeters. U-Shaped Coriolis Flowmeter No Flow Flow Flow Direction T=Mass Operation A Coriolis flowmeter consists of two parallel tubes that are made to oscillate using a magnet. These oscillations are recorded by sensors fitted at the inlet and outlet of each tube. In a no-flow state, the oscillations are synchronised, since there is no mass exerting any force on the tubes. On the other hand, any fluid, gas flowing through the tubes generates Coriolis forces, causing the tubes to twist in proportion to the mass flow rate of the medium. Flow Inlet Flow Outlet A diagram showing phase shift Movement to the inside Movement to the inside Movement to the outside Movement to the outside No Flow With Flow No Flow With Flow Diagram showing the movement of the flow sensors 2 tektrol@tek-trol.com www.tek-trol.com

Tek-Cor 1100A Series Coriolis Flowmeter The Tek-Cor 1100A Series Coriolis Flowmeters are available in the following three configurations: U-Shaped These flowmeters are comprised of two tubes that are arranged in the shape of the letter U, a magnet and coil assembly, and sensors at the inlet and outlet of the tubes. Coriolis forces exerted by the flow medium are used to determine the mass flow rate and density of the medium. U-Shaped sensor (Size 1 ½" to 8") Micro-bend Shaped These flowmeters are comprised of two U-Shaped tubes in a casing with a considerably smaller radius than conventional U-Shaped Coriolis flowmeters. The smaller radius ensures a more compact instrument with significantly lower pressure differential values compared to other flowmeters. Triangle Shaped Micro-bend Shaped sensor (Size ½" to 8") The Triangular flowmeter is the most compact in our range of Coriolis mass flowmeters, designed specifically to provide optimum performance in low-flow applications. It is comprised of a single flow tube which is considerably smaller in size than the conventional U-Shaped tube. Triangle Shaped Sensor (Size ½" to 1") tektrol@tek-trol.com www.tek-trol.com 3

Tek-Cor 1100A Transmitter The Tek-Cor 1100A transmitter is a high-performing transmitter that uses a micro-processor and offers zero calibration, adjustable pulse outputs, an RS485, and a HART communication protocol. It is highly stable and accurate, as well as easy to install and operate. It requires low maintenance which keeps your process downtime to a minimum and covers the cost of ownership over the long term. Benefits Tek-Cor 1100A Transmitter Suitable for aggressive and contaminated media Measurement and display of percent water-cut for oil or water mixtures High rotation frequency and well-balanced measuring tubes Higher Sampling and Digital Filtering Shorter response time No moving parts Can be used in extremely harsh conditions High accuracy for measuring mass flow, density, temperature, and volume flow Application Used to measure steady uniform flow of common viscous fluid, non-newtonian fluid, slurry containing some solid components, and liquids containing some trace of gases Suitable for the bulk measurement of products like syrup, molasses, and raw chemicals Dimensional Drawings Outline Dimension for Triangle Shaped Size Triangle Shaped Sensor (Size ½ to 1 ) 4 tektrol@tek-trol.com www.tek-trol.com

Size L L1 H H1 300# (4 MPa) 600# (6.3 MPa) Integrated Remote ½" 7.08" 7.63" 13.77" 11.41" 10.23" 7.48" (15 mm) (180 mm) (194 mm) (350 mm) (290 mm) (260 mm) (190 mm) 1" 7.87" 7.96" 18.03" 15.74" 11.02" 8.26" (25 mm) (200 mm) (248 mm) (458 mm) (400 mm) (280 mm) (210 mm) Outline Dimensions for U-Shaped Size U-Shaped sensor (Size 1 ½ to 8 ) Size L L1 H H1 300# (4 MPa) 600# (6.3 MPa) Integrated Remote 1½" 20.47" 21.53" 18.5" 25.98" 11.02" 8.26" (40 mm) (520 mm) (547 mm) (470 mm) (660 mm) (280 mm) (210 mm) 2" 21.96" 23.14" 21.65" 27.95" 11.41" 8.66" (50 mm) (558 mm) (588 mm) (550 mm) (710 mm) (290 mm) (220 mm) 3" 30.70" 31.81" 27.95" 40.94" 12.59" 9.84" (80 mm) (780 mm) (808 mm) (710 mm) (1040 mm) (320 mm) (250 mm) 4" 36.22" 37.32" 33.85" 44.88" 13.77" 11.02" (100 mm) (920 mm) (948 mm) (860 mm) (1140 mm) (350 mm) (280 mm) 6" 43.30" 44.88" 41.33" 59.84" 14.96" 12.20" (150 mm) (1100 mm) (1140 mm) (1050 mm) (1520 mm) (380 mm) (310 mm) 8" 53.70" 55.51" 45.66" 65.15" 16.53" 13.77" (200 mm) (1364 mm) (1410 mm) (1160 mm) (1655 mm) (420 mm) (350 mm) tektrol@tek-trol.com www.tek-trol.com 5

Outline Dimension of Micro-bend Shaped Size Micro-bend Shaped Sensor (Size ½" to 8") Size L L1 H H1 300# (4 MPa) 600# (6.3 MPa) Integrated Remote ½" 15.74" 16.29" 11.02" 7.24" 11.41" 8.66" (15 mm) (400 mm) (414 mm) (280 mm) (184 mm) (290 mm) (220 mm) 1" 19.68" 21.10" 14.17" 9.84" 11.81" 9.05" (25 mm) (500 mm) (536 mm) (360 mm) (250 mm) (300 mm) (230 mm) 1½" 23.62" 24.96" 18.11" 11.81" 12.20" 9.44" (40 mm) (600 mm) (634 mm) (460 mm) (300 mm) (310 mm) (240 mm) 2" 31.49" 32.59" 25.19" 16.14" 12.59" 9.84" (50 mm) (800 mm) (828 mm) (640 mm) (410 mm) (320 mm) (250 mm) 3" 35.43" 36.53" 27.55" 19.29" 13.77" 11.02" (80 mm) (900 mm) (928 mm) (700 mm) (490 mm) (350 mm) (280 mm) 4" 44.48" 45.51" 33.85" 25.98" 14.56" 11.41" (100 mm) (1130 mm) (1156 mm) (860 mm) (660 mm) (370 mm) (290 mm) 6" 55.51" 57.08" 47.24" 35.43" 15.74" 12.99" (150 mm) (1410 mm) (1450 mm) (1200 mm) (900 mm) (400 mm) (330 mm) 8" 70.86" 72.59" 57.08" 46.06" 16.53" 13.77" (200 mm) (1800 mm) (1844 mm) (1450 mm) (1170 mm) (420 mm) (350 mm) 6 tektrol@tek-trol.com www.tek-trol.com

Specifications Accuracy ±0.1%, ±0.2%, ±0.5% Repeatability ± 0.05% (for 0.1% accuracy), ± 0.1% (for 0.2% accuracy), ±0.25% (for 0.5% accuracy) Sensor Options U-Series Shaped/Micro-bend Shaped/Triangle Shaped Process Media Liquid, Gas Transmitter Digital type/analog type Power Supply 18-28 VDC, 85-220 VAC Maximum Pressure 3770 PSI (26 MPa) Signal Output 4-20 ma or Pulse Output or RS485 or HART Process Connections DIN, ANSI Flanges Electronics Direct Mount or Remote Mount Diagnostic Functions Reset Totalizer Graphic Display LED Display Operating Elements 3 optical keys for operator Additional Features Low Flow Cut-off, Oil and Water Content Analysis, Zero Calibration, Flow Calibration, Long-Term Stability, Zero Point Adjustment, Conforms IEC 61362 (Industrial) EMC Directive, Useful for all type of sensors i.e. U-Shaped, Triangle Shaped, Micro-bend Shaped Temperature Range Direct Mount -58 F to 257 F (-50 C to 125 C) Remote Mount -58 F to 392 F (-50 C to 200 C ) tektrol@tek-trol.com www.tek-trol.com 7

Size ½" (15 mm) 1" (25 mm) 1½" (40 mm) 2" (50 mm) 3" (80 mm) 4" (100 mm) 6" (150 mm) 8" (200 mm) Maximum Pressure 232 PSI 363 PSI 580 PSI 914 PSI 1450 PSI 2321 PSI 3626 PSI (1.6 MPa) (2.5 MPa) (4.0 MPa) (6.3 MPa) (10 MPa) (16 MPa) (25 MPa) Flow Ranges Flow Range for liquid (U-Shaped) Size (Inch) Allowable Flow Range (lb/h) Flow Range for liquid (Micro-bend Shaped) Normal Flow Range for Accuracy 0.1% (lb/h) Normal Flow Range for Accuracy 0.2%, 0.5% (lb/h) 1½" 706 70547 4410 70547 3307 70547 2" 1103 110231 6614 110231 5512 110231 3" 3087 308647 13228 308647 12126 308647 4" 4410 440924 33070 440924 26456 440924 6" 11024 1102311 77162 1102311 66139 1102311 8" 22047 2204622 154324 2204622 154324 2204622 Size (Inch) Allowable Flow Range (lb/h) Normal Flow Range for Accuracy 0.1% (lb/h) Normal Flow Range for Accuracy 0.2%, 0.5% (lb/h) ½" 45 6613 441 6613 331 6613 1" 177 17636 1323 17636 882 17636 1½" 530 52910 5292 52910 2646 52910 2" 1103 110231 11024 110231 5512 110231 3" 1764 264554 17631 264554 17637 264554 4" 3307 440924 33070 440924 22047 440924 6" 11024 1102311 110232 1102311 55116 1102311 8" 22047 2204622 220463 2204622 1102312 2204622 8 tektrol@tek-trol.com www.tek-trol.com

Flow Range for Gas Size (Inch) Measurable Flow Range (lb/h) Flow Range with 0.5% (lb/h) ½" 34 6613 166 6613 1" 89 17636 445 17635 1½" 706 70547 1770 70545 2" 1103 110231 2760 110230 3" 1544 308647 7720 308647 4" 2205 440924 11025 440924 6" 5512 1102311 27560 1102311 Installation Micro-bend Shaped installation For Liquid or Slurry For Gas For Liquid, Slurry, or Gas Picture-1 Picture-2 Picture-3 tektrol@tek-trol.com www.tek-trol.com 9

U-Shaped Installation For Liquid or Slurry For Gas For Liquid, Slurry, or Gas Picture-1 Picture-2 Picture-3 For the horizontal installation, the measuring tube should be installed downside of the pipeline when the process medium is liquid or slurry (shown in Picture 1) and upside of the pipeline when the process medium is gas (shown in Picture 2). For vertical installation, the measuring tube should be installed beside the pipeline when the process medium is liquid, slurry, or gas (shown in Picture 3). If gas bubbles are expected, the meters must not be mounted at the highest point of the tubing (A). If solid particles are expected the meters must not be mounted at the lowest point (B) of the pipeline. The meters must not be mounted in a drop line near the open end (C), as this can cause the meters to run empty. A B C 10 tektrol@tek-trol.com www.tek-trol.com

Model Chart EXAMPLE Tek-Cor 1100A 2 1 025B 1 S 150 1 E Tek-Cor 1100A-2-1-025B-1-S-150-1-E Series Tek-Cor 1100A Coriolis Mass Flow Meter Type 1 2 U-Shaped Micro-bend Shaped 3 Triangle Shaped Process Media 1 Liquid or Gas 015A ½", ± 0.5% Accuracy (M and T type only) 025A 1", ± 0.5% Accuracy (M and T type only) 040A 1-½", ± 0.5% Accuracy (M and U type only) 050A 2", ± 0.5% Accuracy (M and U type only) 080A 3", ± 0.5% Accuracy (M and U type only) 100A 4", ± 0.5% Accuracy (M and U type only) 150A 6", ± 0.5% Accuracy (M and U type only) 200A 8", ± 0.5% Accuracy (M and U type only) 015B 025B ½", ± 0.2% Accuracy (M and T type only) 1", ± 0.2% Accuracy (M and T type only) 040B 1-½", ± 0.2% Accuracy (M and U type only) Size and Accuracy 050B 080B 100B 150B 200B 2", ± 0.2% Accuracy (M and U type only) 3", ± 0.2% Accuracy (M and U type only) 4", ± 0.2% Accuracy (M and U type only) 6", ± 0.2% Accuracy (M and U type only) 8", ± 0.2% Accuracy (M and U type only) 015C ½", ± 0.1% Accuracy (M and T type only) 025C 1", ± 0.1% Accuracy (M and T type only) 040C 1-½", ± 0.1% Accuracy (M and U type only) 050C 2", ± 0.1% Accuracy (M and U type only) 080C 3", ± 0.1% Accuracy (M and U type only) 100C 4", ± 0.1% Accuracy (M and U type only) 150C 6", ± 0.1% Accuracy (M and U type only) 200C 8", ± 0.1% Accuracy (M and U type only) Electronics 1 2 Direct Mount Remote Mount (comes with 10 meters of cable) Output I S 4-20 ma, HART, Pulse 4-20 ma, Modbus RS485, Pulse 025 DIN 2.5 MPa Flange 040 DIN 4 MPa Flange 100 DIN 10 MPa Flange Process 160 DIN 16 MPa Flange Connection 260 DIN 26 MPa Flange 150 150# ANSI Flange 300 300# ANSI Flange Power Supply 600 1 2 600# ANSI Flange 18-28 VDC 85-220 VAC Approvals E UL Class I Div. I tektrol@tek-trol.com www.tek-trol.com 11

Popular Models MODEL NO. 1100A-2-1-015A-1-S-150-1-E 1100A-2-1-025A-1-S-150-1-E 1100A-2-1-040A-1-S-150-1-E 1100A-2-1-050A-1-S-150-1-E 1100A-2-1-080A-1-S-150-1-E 1100A-2-1-015B-1-S-150-1-E 1100A-2-1-025B-1-S-150-1-E 1100A-2-1-040B-1-S-150-1-E 1100A-2-1-050B-1-S-150-1-E 1100A-2-1-080B-1-S-150-1-E DESCRIPTION Explosion-proof ½", 0.5%, 150# ANSI Flange Explosion-proof 1", 0.5%, 150# ANSI Flange Explosion-proof 1.5", 0.5%, 150# ANSI Flange Explosion-proof 2", 0.5%, 150# ANSI Flange Explosion-proof 3", 0.5%, 150# ANSI Flange Explosion-proof ½", 0.2%, 150# ANSI Flange Explosion-proof 1", 0.2%, 150# ANSI Flange Explosion-proof 1.5", 0.2%, 150# ANSI Flange Explosion-proof 2", 0.2%, 150# ANSI Flange Explosion-proof 3", 0.2%, 150# ANSI Flange 12 tektrol@tek-trol.com www.tek-trol.com

Customer Service and Support TEKMATION LLC reserves the right to change the designs and/or materials of its products without notice. The contents of this publication are the property of TEKMATION and cannot be reproduced by any other party without written permission. All rights reserved. Copyright 2016 TEKMATION LLC TEKMATION LLC DOC # TEK/AK/180110/TEK-COR/[9] www.tek-trol.com Tek-Trol is a fully owned subsidiary of TEKMATION LLC. We offer our customers a comprehensive range of products and solutions for process, power, and oil and gas industries. Tek-Trol provides process measurement and control products for Flow, Level, Temperature and Pressure Measurement, Control Valves and Analyzer systems. We are present in 15 locations globally and are known for our knowledge, innovative solutions, reliable products, and global presence. Tek-Trol LLC 796 Tek Drive Crystal Lake, IL 60014 USA Tel: +1 847 857 6076, +1 847 655 7428 Fax: +1 847 655 6147 Email: tektrol@tek-trol.com www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSyss