Effects of Delayed RCP Trip during SBLOCA in PWR

Similar documents
Loss of Normal Feedwater Analysis by RELAP5/MOD3.3 in Support to Human Reliability Analysis

Verification and validation of computer codes Exercise

EXPERIMENTAL INVESTIGATION AND FLOW VISUALIZATION OF STEAM CONDENSATION IN A SCALED IRWST-ADS SIMULATOR

EXPERIMENTAL SUPPORT OF THE BLEED AND FEED ACCIDENT MANAGEMENT MEASURES FOR VVER-440/213 TYPE REACTORS

Research Article Remarks on Consistent Development of Plant Nodalizations: An Example of Application to the ROSA Integral Test Facility

International Agreement Report

Nuclear safety Lecture 4. The accident of the TMI-2 (1979)

ASVAD THE SIMPLE ANSWER TO A SERIOUS PROBLEM. Automatic Safety Valve for Accumulator Depressurization. (p.p.)

RELAP5 Code Study of ROSA/LSTF Experiments on PWR Safety System Using Steam Generator Secondary-Side Depressurization

SENSITIVITY ANALYSIS OF THE FIRST CIRCUIT OF COLD CHANNEL PIPELINE RUPTURE SIZE FOR WWER 440/270 REACTOR

Classical Event Tree Analysis and Dynamic Event Tree Analysis for High Pressure Core Melt Accidents in a German PWR

Exekon. Nuclear. ý C)C) ý. May 9, 2001 SVP U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C.

SAFETY DEMONSTRATION TESTS ON HTR-10

International Agreement Report

Experimental Verification of Integrated Pressure Suppression Systems in Fusion Reactors at In-Vessel Loss-of -Coolant Events

Engineering & Projects Organization

NE 405/505 Exam 2 Spring 2015

HEALTH AND SAFETY EXECUTIVE HM NUCLEAR INSTALLATIONS INSPECTORATE

1 SE/P-02. Experimental and Analytical Studies on Thermal-Hydraulic Performance of a Vacuum Vessel Pressure Suppression System in ITER

CFD SIMULATIONS OF GAS DISPERSION IN VENTILATED ROOMS

An Improved Modeling Method for ISLOCA for RI-ISI and Other Risk Informed Applications

Safety Analysis: Event Classification

THE NITROGEN INJECTION THREAT IN PWR REACTORS

Transient Analyses In Relief Systems

SHUTDOWN SYSTEMS: SDS1 AND SDS2

CONTENTS OF THE PCSR CHAPTER 1 - INTRODUCTION AND GENERAL DESCRIPTION

FUNDAMENTAL SAFETY OVERVIEW VOLUME 2: DESIGN AND SAFETY CHAPTER P: REFERENCE OPERATING CONDITION STUDIES (PCC)

HTR Systems and Components

AP1000 European 19. Probabilistic Risk Assessment Design Control Document

IAEA SAFETY STANDARDS for protecting people and the environment

How to Optimize the Disposal System With Staggered Analysis Using BLOWDOWN Technology. Jump Start Guide

DETAILS OF THE ACCIDENT PROGRESSION IN 1F1

ON TRANSIENTS IN PUMA

The Nitrogen Threat. The simple answer to a serious problem. 1. Why nitrogen is a risky threat to our reactors? 2. Current strategies to deal with it.

NUBIKI Nuclear Safety Research Institute, Budapest, Hungary

V.H. Sanchez Espinoza and I. Gómez-García-Toraño

Contents. Foreword. Acknowledgements. General Introduction

UKEPR Issue 01

NUCLEAR POWER BUSINESS UNIT TRAINING JOB PERFORMANCE MEASURES. JPM P COT Revision 0 DRAFT October 4, 2000

Tools and Methods for Assessing the Risk Associated with Consequential Steam Generator Tube Rupture

NORMAL OPERATING PROCEDURES Operating Parameter Information

Profile LFR-43 HELENA ITALY. Italian National Agency for New Technologies, Energy and Sustainable Economic Development, C.R. ENEA Brasimone, Italy

FUNDAMENTAL SAFETY OVERVIEW VOLUME 2: DESIGN AND SAFETY CHAPTER I: AUXILIARY SYSTEMS. A high-capacity EBA system [CSVS] [main purge]

Start-up of the Three-shaft Closed Loop

IAEA SAFETY STANDARDS for protecting people and the environment

SEBIM PILOT OPERATED TANDEMS A NEW SOLUTION FOR DARLINGTON NGS BLEED CONDENSER RELIEF VALVES. HORST PAETZOLD Ontario Hydro Nuclear - Darlington NGD

Reliability Estimation for Check Valves and Other Components. K. L. McElhaney and R. H. Staunton

HIGH FLOW PROTECTION FOR VARIABLE SPEED PUMPS

Enhancing NPP Safety through an Effective Dependability Management

Injector Dynamics Assumptions and their Impact on Predicting Cavitation and Performance

EMERGENCY CORE COOLING SYSTEM SIMPLIFICATION

Safety Standards. of the Nuclear Safety Standards Commission (KTA)

The Davis Besse Nuclear Power Plant Three Mile Island Accident Precursor Event September 24, 1977

MODELLING AND SIMULATION OF FIRETUBE BOILERS WITH ECOSIMPRO: ANALYSIS OF CONTINUOUS AND STAND-BY OPERATION

EXPERIMENTAL STUDY OF HEAT, MASS AND MOMENTUM TRANSFERS IN A SPRAY IN THE TOSQAN FACILITY

EXPERIMENTAL STUDY OF HEAT, MASS AND MOMENTUM TRANSFERS IN A SPRAY IN THE TOSQAN FACILITY

Gas Accumulation Potential & Leak Detection when Converting to Gas

Visual Observation of Nucleate Boiling and Sliding Phenomena of Boiling Bubbles on a Horizontal Tube Heater

Comparison of MARS-KS to SPACE for counter current flow limitation model

Event tree analysis. Prof. Enrico Zio. Politecnico di Milano Dipartimento di Energia. Prof. Enrico Zio

IAEA Headquarters in Vienna, Austria 6 to 9 June 2017 Ref No.: CN-251. Ivica Bašić, Ivan Vrbanić APoSS d.o.o.

Requirements for Reduced Supervision of Power Plants, Thermal Liquid Heating Systems, and Heating Plants

Office for Nuclear Regulation

API Standard Venting Atmospheric and Low-Pressure Storage Tanks: Nonrefrigerated and Refrigerated

Release: 1. UEPOPL002A Licence to operate a reciprocating steam engine

(C) Anton Setzer 2003 (except for pictures) A2. Hazard Analysis

SIMULATION OF CONTAINMENT HYDROGEN CONTROL SYSTEM AT IGNALINA NPP

GUIDE YVL 3.7 / 26 Se p t e m b e r 2008

-. 30ýv. Entergy ARKANSAS NUCLEAR ONE - UNIT I IMPROVED TECHNICAL SPECIFICATIONS SUBMITTAL. 05/01101 Supplement Volume 2 of 2. (Sections 3.7 and 3.

Evaluation of the fraction of Unit-3 vent gas that flowed into Unit-4 reactor building

Application Note 13: Electron Microscope Decontamination

FUNDAMENTAL SAFETY OVERVIEW VOLUME 2: DESIGN AND SAFETY CHAPTER I: AUXILIARY SYSTEMS 2. VOLUME AND CHEMICAL CONTROL (RCV [CVCS])

Dilution During Small Break LOCAs in PWRs

Finding leaks in Main Cryogenic Heat Exchangers without shutdown

Instrumentation systems of BWR

RISKAUDIT GRS - IRSN Safety assessment of the BELENE NPP

Modelling of the Separated Geothermal Water Flow between Te Mihi flash plants

Inspection Credit for PWSCC Mitigation via Peening Surface Stress Improvement

Gas Vapor Injection on Refrigerant Cycle Using Piston Technology

REGULATORY OBSERVATION

Energy Control. Suite 2A, 55 Frid Street Hamilton, ON L8P 4M3 office: cell:

Micro Channel Recuperator for a Reverse Brayton Cycle Cryocooler

Inerting System Design for Medium Speed Vertical Spindle Coal Pulverizers TABLE OF CONTENTS

OLGA. The Dynamic Three Phase Flow Simulator. Input. Output. Mass transfer Momentum transfer Energy transfer. 9 Conservation equations

Linear Compressor Discharge Manifold Design For High Thermal Efficiency

IEM on Severe Accident Management in the light of the accident at the Fukushima Daïchi NPP

DDnmm,-- SEP U. S. Nuclear Regulatory Commission Attn.: Document Control Desk Mail Stop OP1-17 Washington, D. C

Control Strategies for operation of pitch regulated turbines above cut-out wind speeds

Series 3730 and Series 3731 EXPERTplus Valve Diagnostics with Partial Stroke Test (PST)

Workshop Information IAEA Workshop

How to reinforce the defence-indepth in NPP by taking into account natural hazards?

STUDY OF SLUG CONTROL TECHNIQUES IN PIPELINE SYSTEMS

Reduce Turnaround Duration by Eliminating H 2 S from Flare Gas Utilizing VaporLock Scrubber Technology

PRA Methodology Overview

Presented to the Israel Annual Conference on Aerospace Sciences, 2009 RISK-ANALYSIS A SUPPLEMENT TO DAMAGE-TOLERANCE ANALYSIS

Job Sheet 1. Geothermal Energy

Hazard Operability Analysis

Simulation of Experiment on Aerosol Behaviour at Severe Accident Conditions in the LACE Experimental Facility with the ASTEC CPA Code

DRAFT REGULATORY GUIDE DG-1074

Sizing of extraction ventilation system and air leakage calculations for SR99 tunnel fire scenarios

Transcription:

Effects of Delayed RCP Trip during SBLOCA in PWR Javier Montero Technical University of Madrid, Alenza 4, 28003, Madrid, Spain fj.montero@alumnos.upm.es Cesar Queral, Juan Gonzalez-Cadelo cesar.queral@upm.es, jg.cadelo@alumnos.upm.es ABSTRACT After TMI accident, the issue of when tripping the RCPs in case of SBLOCA became very important. The results obtained from the analysis of different vendors showed that the RCPs should be tripped early in the accident. This analysis have been reviewed by the group of the Energy System Department of the Universidad Politecnica de Madrid (UPM) with the Almaraz NPP (Westinghouse 3-loop) model for TRACE 5.0 patch 1 code in order to compare the results obtained for a Best Estimate (BE) code with the results obtained previously by Westinghouse for a conservative code. Since the BE model has not showed a damage region for any case, it has been decided to implement some conservatism in the model. With this new model, a similar region such as in the Westinghouse case has been found, confirming that it is convenient to trip the RCPs early in the accident in order to avoid the damage. The results also show that the analysis performed by Westinghouse is more conservative than the analysis performed with TRACE code. 1 INTRODUCTION The reactor coolant pump trip was a key parameter in Three Miles Island (TMI) accident. After shutdown of the last two Reactor Coolant Pumps (RCPs), the level of water decreased and core uncovery happened, [1]. Therefore the time in which the RCPs should be tripped in case of Small Break Loss of Coolant Accident (SBLOCA) was an important issue that led to analyze three different possibilities: RCPs off. The pumps are shut down at the time in which the SBLOCA takes place. The forced convection is lost and hence, the core cooling is reduced. RCPs on. The pumps remain operating during the accident. In the event of SBLOCA in which the RCPs are not tripped, a good cooling would exist by forced convection. In TMI accident, before stopping the last pump core cooling was being maintained by a two-phase mixture. RCPs trip delay. The pumps are tripped at any time during the accident. If the system evolves to a high void fraction because of RCPs operation, and then they are tripped for any reason (i.e high vibration), the void collapse could lead to substantial core uncovery and the temperatures could exceed the acceptance criteria (2200F /1477K), [2]. 516.1

516.2 The continuous operation of the RCPs during SBLOCA was considered as the most aceptable mode for operating. For this reason the USNRC instructed the operators to keep the RCPs running in case of SBLOCA with actuation of High Pressure Safety Injection (HPSI). [4],[5] and [6]. Later, exhaustive evaluations performed by Babcok & Wilcox (B&W), Combustion Engineering (CE) and Westinghouse concluded that both, delayed RCP trip and continuous operation of RCPs could lead to excessive temperatures in the fuel, [2]. Each vendor provided an exhaustive delayed RCP trip analysis using a conservative model which met the 10 CFR 50 appendix K requirements. The purpose was to identify which combinations of break size-rcp trip would lead to excessive peak cladding temperatures (PCTs). Then the USNRC required an immediate manual pump trip following reactor trip and indication of HPSI actuation, [7] and [8]. Westinghouse calculations for a three-loop plant showed that the range of break size diameters in which the PCT could exceed the permitted limits were between 2 and 4 inches, [2]. It was observed that if the pumps remained running throughout the entire accident, no excessive cladding temperatures would be achieved. Figure 1, points out that for 3 inch break in the cold leg, the maximum available time for the operator to trip the RCP is less than 600 seconds. Figure 1: Westinghouse analysis for delayed RCP trip. Data obtained from [3] 2 ANALYSIS OF RCP TRIP DELAY WITH A TRACE MODEL OF ALMARAZ NPP 2.1 Almaraz-1 TRACE model Almaraz NPP located in Cceres (Spain), has two PWR units, each of them are three loop PWR Westinghouse design. Almaraz Unit 1 TRACE model has 255 thermal-hydraulic components (2 VESSEL, 73 PIPE, 43 TEE, 54 VALVE, 3 PUMP, 12 FILL, 33 BREAK, 32 HEAT STRUCTURE and 3 POWER component), 740 SIGNAL VARIABLES, 1671 CONTROL BLOCKS and 58 TRIPS, Figure 2.

516.3 Figure 2: Almaraz NPP SNAP-TRACE model 2.2 Cold Leg SBLOCA reference case. Best Estimate model In the first analysis, a best estimate model have been used in order to check how the RCP trip affect the sequence evolution. Only the cases for RCP ON/OFF have been performed. In this first group of simulations several conditions were imposed in the model: 2 inches break in the cold leg, only 1 HPSI train available, 3 of 3 accumulators and no secondary side depresurization. The break takes place at t= 5000 seconds. As it can be seen in Figure 3 no high values of PCT are obtained either, for the case with RCP ON and RCP OFF. It was observed that pressure in the case with RCPs ON is slightly greater than the case with RCPs OFF and the mass flow through the break was higher in the case in which the pumps are running. When RCP ON, the core level was very low, however the RCPs were able to maintain forced circulation in order to cool the core. When the RCPs were tripped there was enough amount of coolant in the core for maintaining low temperatures. This result is mainly due to use of a best estimate model. Therefore it was decided to use a conservative model in a similar way as the previous vendors analysis. 2.3 Conservative TRACE Model for Almaraz NPP and comparison with the BE analysis In this section an analysis with the conservative model have been performed. Its results have been compared with the obtained for the Best Estimate model. In order to obtain a conservative model, several hypothesis have been implemented in it. Most of this hypothesis are typical from final safety analysis report (FSAR) such as reduction of the safety injection set point or failure of the steam dump control,[9]. Once the hypothesis have been implemented into the model, some differences are observed,see Figure 4. In the conservative model with RCP OFF, high PCT is obtained. With RCPs ON(BE and conservative) the simulations showed that the core level was lower than in the cases with RCPs OFF but the forced circulation was able to prevent high PCT values. The core liquid level in the case with RCPs OFF and using the conservative model was slightly lower than in the BE case. These differences make possible that high PCTs can be reached. After this analysis, it was considered that the model was ready to perform an exhaustive analysis regarding RCP trip issue.

516.4 Figure 3: Comparison RCP ON/OFF. SBLOCA 2inch cold leg. PCT Figure 4: Comparison BE vs conservative. RCP on/off. SBLOCA 2inch cold leg. PCT 2.4 RCP Trip Delay Analysis. Conservative model This section presents the analysis performed with the conservative Almaraz NPP TRACE model. The scope of this analysis was to find out a break spectrum in which the RCP trip during SBLOCA could produce undesirable results.

516.5 Such as in the analysis performed by Westinghouse, SBLOCA sequences for different RCP trip times and different break sizes were simulated. The results obtained were very similar to the results obtained by Westinghouse. The cases in which the limit is exceeded, are bounded for break sizes between 2 and 3 inch in cold leg with RCP trip times beyond 1000 seconds. In order to compare the Westinghouse analysis with the ones performed by the Universidad Politcnica de Madrid (UPM), Figure 5 shows the main results obtained. As in Westinghouse analysis, if the RCP trip takes place at any time during the transients for 2 and 3 inches break size diameter, the PCT limit could be exceeded. For 4 inches break diameter this situation does not occur for both, Westinghouse analysis and UPM analysis, the reason is that the break is large enough to depressurize the system until the accumulator setpoint and to allow the discharge of them; this action avoids the core damage. The main difference between both analyses is the RCP trip time in which the maximum PCT is reached. For the UPM group analysis this time is about 700 seconds later than for Westinghouse analysis, see Figure 5. Since the Westinghouse analysis was performed with a conservative code such as WFLASH, [10] the differences in PCTs and the time in which they are reached, come from the nature of the code as well as possible differences in the model. Figure 5: Damage curves-rcp trip delay-almaraz NPP vs Westinghouse analysis In Figures 6 and 7 the main results for SBLOCA 2 inch in cold leg are shown. The RCP trip times in which the PCTs are exceeded, are between 3500 seconds and 4000 seconds after the break occurs. Looking at Figure 7, the core liquid volume fraction, it is clear that for these RCP trip times the core is uncovered longer, and the pressures are not low enough for allowing the actuation of the accumulators. For 4500 RCP trip time after the break, the pressure falls to the accumulators setpoint ( 45bar) and the core is immediately covered due to the flow discharge, this action avoid the damage in this case. Figure 8 shows the PCT observed for each break diameter as function of RCP trip time. The highest band (red area) represents the points in which the acceptance criteria (1477K) is exceded while the points of the second band (in yellow) represent the region close to damage. The other regions are far enough from the limit.

516.6 Figure 6: Conservative analysis. RCP trip delay times. SBLOCA 2 inch cold leg. PCT Figure 7: Conservative analysis. RCP trip delay times. SBLOCA 2 inch cold leg. Core level

516.7 Figure 8: PCT as function of RCP trip time and break size 3 CONCLUSIONS The main conclusions arisen from this analysis are: With a best estimate code it is not possible to reproduce a conservative analysis unless some conservative hypotheses are implement in the model. Once the model becomes a conservative model, similar results than in the previous analysis performed by Westinghouse are obtained, confirming that it is convenient to trip the RCPs early in the accident in order to avoid the damage, however due to the fact that the Westinghouse analysis was performed with WFLASH code, their results are more conservative. It has been demonstrated for Almaraz NPP TRACE model that there is enough time (around 1000seconds) in order to trip the RCPs in case of SBLOCA, before the limit is exceeded. ACKNOWLEDGMENTS This work is funded by Consejo de Seguridad Nuclear (CAMP project) and also by the Spanish Ministry of Economy and Competitiveness in the ISAMAR project (ENE201128256). Our group would also like to thank Almaraz-Trillo AIE for the technical and financial support which allowed to perform this work. REFERENCES [1] USNRC. Perspectives on Reactor Safety. Rev 1. NUREG/CR-6042, 1997 [2] B. Sheron, Generic Assesment of Delayed Reactor Coolant Pump Trip during Small Break Loss-of.Coolant Accidents in Pressurized Water Reactors, USNRC, NUREG- 0623, 1979

516.8 [3] Analysis of Delayed Reactor Coolant Pump trip during small loss of Coolant Accidents for Westinghouse Nuclear Steam Supply Systems. Westinghouse Electric Corporation, WCAP-9584/WCAP-9585(Proprietary / Non-Proprietary versions), 1980 [4] Nuclear incident at Three Mile Island - Supplement. Bulletin 79-05A April, 1979 [5] Review of operational errors and systems misalignaments identified during the TMI incident. Bulletin 79-06A, April, 1979 [6] Review of operational errors and systems misalignaments identified during the TMI incident. Bulletin 79-06B, April, 1979 [7] Nuclear incident at Three Mile Island - Supplement. Bulletin 79-05C, July, 1979 [8] Nuclear incident at Three Mile Island - Supplement. Bulletin 79-06C July, 1979 [9] M. Bolander, C.D. Fletcher, TRACE SMALL BREAK LOSS-OF-COOLANT ACCI- DENT ANALYSES FOR A WESTINGHOUSE THREE-LOOP PLANT, Information Systems Laboratories, Inc. Prepared for USNRC, 2005 [10] Esposito, V., et al, WFLASH - A Fortran IV Computer Program for Simulation of Transients in a Multi-Loop PWR, WCAP-8261, Rev 2, June 1974.