COAL AND GAS OUTBURST COMMITTEE. HALF DAY SEMINAR Wollongong 22 nd June, 2011

Similar documents
! Time required for inertisation output to interact with and extinguish a fire.

Goaf Inertisation and Sealing Utilising Methane from In-Seam Gas Drainage System

CENTENNIAL COAL. Handling Gas Problems at Tahmoor Colliery Bob Newman, Ventilation Officer

Challenges encountered by New Zealand mines rescue at the Pike River mine disaster

A.M. Wala, A.D.S. Gillies and H.W. Wu, Lessons from an Underground Coal Mine Fire in Australia using Retrospective Numerical Simulation Study,

Applied Modelling of Ventilation and Gas Management to Increase Production in a Single Entry Longwall Panel

NZQA unit standard version 3 Page 1 of 8. Manage the mine ventilation system at an extractive site

MINING INQUIRY BOX FLAT COLLIERY REPORT, FINDINGS AND RECOMMENDATIONS

Application of the QMRS GAG at Crinum North Mine

COAL AND GAS OUTBURST COMMITTEE

T.I. Mayes and A.D.S Gillies. A Review of Current Australian Longwall Mine Ventilation Practice, Proceedings, First Mine Environment and Ventilation

Interpreting the Status of an Underground Coal Mine Heating for Valid Risk Management and Control

The Role of Gas Monitoring in the Prevention and Treatment of Mine Fires

Abstract: Learnings from 18 Level 1 Emergency Exercises Martin Watkinson, Executive Mining Engineer Simtars Introduction 1 Southern Colliery 1998

2. Introduction of nitrogen injection displacement for fire extinguishment

OUTBURST THRESHOLD LIMITS ARE THEY APPROPRIATE?

2018 STATEMENTS OF FACT MINE RESCUE. 1. To test for methane, use a methane detector or chemical analysis.

Published as: A.D.S. Gillies, H.W. Wu, D. Reece and R. Hosking, use of mine fire simulation for emergency preparedness, Proceedings, Queensland

The Effect of Air Column in Transport Canisters on Measured Gas Contents

Challenges of gas monitoring and interpretation in underground coal mines following an emergency

Review of oxygen deficiency requirements for graham s ratio

T.I. Mayes and A.D.S Gillies. An Analysis of Current Australian Longwall Ventilation Methods, Proceedings, Seventh International Mine Ventilation

2015 Northern Nevada Regional Mine Rescue Contest Winnemucca Events Center Winnemucca, NV March 11 & 12

Proactive Strategies for Prevention and Control of Fires in Bord and Pillar Mines Working in Thick Coal Seams

RESPIRABLE DUST RESULTS FROM NSW LONGWALL MINES

Investigations into the identification and control of outburst risk in Australian underground coal mines

Southern Districts Emergency Escape System

2012 THE KEMI MINE SAFETY & TRAINING COMPETITION SUPERINTENDENT S STATEMENT DAY 1

CFD Modelling of Goaf Gas Migration to Improve the Control of Spontaneous Combustion in Longwalls

COAL MINES TECHNICAL SERVICES, GAS DETECTION RELATED SERVICES FOR MINES RESCUE

Evaluation of the optimum conditions for a local ventilation system in connection with the mine ventilation network

Australian longwall panel ventilation practices

Challenges in undertaking inertisation of fires in underground mines

Dust Monitoring and Control Efficiency Measurement in Longwall Mining

In revision of former recommendations as of 1990 and 2005, the German Mine Rescue Committee (DA GRW) has adopted new guidelines for non-coal mine

Dust Measurement and Control in Thick Seam Mining

Working in Gas Hazard Areas

Material Safety Data Sheet (MSDS)

Handling, storage and use of gas cylinders

PARFIX GAP FILLER (ALL HOURS)

Gas Emission Modelling of Gate Road Development

2018 National Metal and Nonmetal Mine Rescue Contest. Mine Rescue Field Competition Written Test. Good Luck!

Dust Measurement and Control in Thick Seam Mining 1

AIDGC PRESENTATION MARCH 2006 HAZARDOUS AREAS STANDARDS & CLASSIFICATION

Emergency management systems and plans

POLYFILLA GAP FILLER - WHITE

2017 DAY #1 MINE RESCUE PROBLEM

MATERIAL SAFETY DATA SHEET. Compressed 99% NITROGEN and 1% HELIUM

Simulation of the Effects of Inertisation of Fires on Mine Ventilation Systems

Based on available information, not classified as hazardous according to criteria of Safe Work Australia; NON-HAZARDOUS SUBSTANCE.

NO MORE GAPS MULTIPURPOSE WHITE. Selleys Australia, a division of DuluxGroup (Australia) Pty Ltd ABN:

Department of Mineral Resources New South Wales

Ready to use oil based insecticide for controlling various home garden insect pests.

SAFE ESCAPE FROM LONGWALL DEVELOPMENT SECTION IN CASE OF A BELT FIRE

SPONTANEOUS COMBUSTION AT THE BLAIR ATHOL COAL MINE. S Prebble and A Self

FIRE PROCEDURES DISTRICT MINE

PARFIX COLOUR FLEX. Based on available information, not classified as hazardous according to criteria of Safe Work Australia; NON-HAZARDOUS SUBSTANCE.

ADVANCES IN GAS DRAINAGE & GAS MANAGEMENT WITHIN AAMC - RUSSELL PACKHAM. Gas and Coal Outburst Committee Seminar, Wollongong, 23 rd November 2011.

Material Safety Data Sheet 1. IDENTIFICATION OF THE MATERIAL AND SUPPLIER

Guideline 4 Restraining individual gas cylinders and other gas products for transport

APPLYING VIRTUAL REALITY TO ONTARIO MINE RESCUE OPERATIONS

Faculty/School: Pharmacy Initial Issue Date: Oct Dr. Alpesh Patel and Padmaja Dhanvate

Emergency escape systems

Safety Data Sheet Face and Body Crayons

Jaco Swartz 25 May 2017

(ALL HOURS)

Oral Exam Explosives

SAFETY DATA SHEET. Section 1: IDENTIFICATION MICROL

1. SUBSTANCE IDENTIFICATION/ PREPARATION AND COMPANY DETAILS

TITLE : Routine testing of the Dubaco stone dust bags. REPORT No : REQUESTED BY : Pierre Vassard DUBACO (Pty) Ltd

Chemical Entity CAS No. Proportion (to 100%)

INSECTICIDE RTU. Yates Australia, a division of DuluxGroup (Australia) Pty Ltd ABN:

FIRE FIGHTER II JPR: FFII-1A

ESCONDIDO FIRE DEPT TRAINING MANUAL Section Truck Module Page 1 of 5 Utilities Gas Emergencies Revised

MATERIAL SAFETY DATA SHEET

Computer Simulation Programms in Mine Rescue Education and Training, on the Example of Student Mine Rescue Teams

ChargeAir TM. System Developments in SCBA-Based Escape Equipment. Draeger Safety Inc. Engineered Solutions

The Austrian mine rescue service. Thomas Spörker Dublin, 9 th October 2014

TITLE 25. ENVIRONMENTAL PROTECTION DEPARTMENT OF ENVIRONMENTAL PROTECTION ENVIRONMENTAL HEALTH AND SAFETY ARTICLE IV. OCCUPATIONAL HEALTH AND SAFETY

GROUT STAIN WHITENER. For advice, contact a Poisons Information Centre (e.g. phone Australia ; New Zealand ) or a doctor.

SUPERINTENDENT STATEMENT THANK YOU FOR ANSWERING OUR CALL FOR HELP. I AM, THE MINE SUPERINTENDENT FOR THE JENNY MINE NO. 1. YOU ARE LOCATED ON THE

MATERIAL SAFETY DATA SHEET FOR: FULLER TRADE GAP FILLER Replaces: July 2008 Date of issue: January 2009

Gas Accumulation Potential & Leak Detection when Converting to Gas

SUPER KLEEN MULTI-PURPOSE

Galva Fire Department SOP

Safety Data Sheet According to NOHSC:2011(2003)

Health and Safety in Employment (Mining Operations and Quarrying Operations) Regulations 2013 (SR 2013/483)

Label 2.2: Non-flammable, Non-toxic gas 1. IDENTIFICATION OF THE SUBSTANCE/PREPARATION AND OF THE COMPANY/UNDERTAKING

TURTLE WAX F21 WHEEL CLEANER

(ALL HOURS)

What is Part 50? The regulations also require operators and contractors to report employment data.

STORM WATER RETENTION TANKS MAINTENANCE INFORMATION FOR HEALTH AND SAFETY FILE

Safety Data Sheet Creatistics Dough

Apparatus Operator Refresher Training Program

Safety Data Sheet According to NOHSC:2011(2003)

EDUCATION DEPARTMENT ACCU-TEST

LPG SAFETY INFORMATION. Kwik-Gas. Safety Manual. Less talk more energy

NATURAL GAS RESPONSE SOG

Safety Data Sheet Vanilla Fresh

Pressure piling and the impacts of blast relief to protect primary fans in a highwall longwall operation

Transcription:

COAL AND GAS OUTBURST COMMITTEE HALF DAY SEMINAR Wollongong 22 nd June, 2011 Contents Raising the Outburst Threshold at Tahmoor Colliery Peter Wynne Page 1 Virtual Reality Training - Jeff Buchanan, NSW Mines Rescue Page 13 The Pike River NZ Disaster Peter Robbins, NSW Mines Rescue Page 21 Coal 2012 Page 72 Editor s Note: Please refer to the University of Wollongong Mining website at the following address for a better, colour view of the presentations. http://www.uow.edu.au/eng/outburst/ Research and publication Presentations

Jeff Buchanan, Training Officer, Southern Mines Rescue Station Questions and Discussion Bob Gordon, Appin Colliery Area 9 How far away are we from having virtual training available and as a competency assessment tool? Jeff We need a solid platform for training people and to assess their competence. We can do it, but will need participation by the industry. We have ipods we can set up with the Draeger gas detector. They relate to gases as they see it so what you see in the hand is real time. We use Ventsim computer software to judge the distance of smoke and the time smoke came into the panel, we normally ventilate the panel and the rate it would travel up the returns. The technology advances, we have three idome VR simulators at each rescue station to click individuals in, and it may be with the assistance of industry experts who would be your current competent miner drivers to work with us to develop the program and help assess the operators. Peter Robbins, Southern Mines Rescue Station - Mines Rescue have been approached by a mining company and there has been work done towards continuous miner and shearer driver training with the aim of making the consol mimic the actual radio control used by the operator. That work is under way, but is commercially sensitive. Jeff We require assistance from the industry for direction. We are working with the coal miners of the future. Request from Bruce Dowsett VRT, the current VR outburst training module is captured in two scenarios UNSW and VR Space. This is used for new inductees, contractors and refresher training. We are currently modelling our third generation VR outburst training module scenario with QinetQ which needs to capture the last line of defence at the face i.e. signs and indicators. We need to consult with industry to get good photos, information etc that would assist in our development. We now have greater flexibility eg. Change gas levels, etc and will capture an outburst event under remote mining conditions in a gate road development. The second part is to demonstrate the use of Management Plans and preventative measures. We also want to check on currency and updated methodology, contact volunteers who can provide photos and information so we can provide a module that achieves their training needs. At a recent Mines Rescue Competition involving International and Australian teams, the following scenario was put to the captains. What would you do if you encountered smoke and the gas detectors indicated 300 ppm CO? The expectation was the captain would have his team to put on their rescue suits, which they did, then make their way to the crib room to make a telephone call, which they all did. Using the mine plan they had to find the best way to get themselves out of the smoke and onto the intake side of the fire. The expectation was they would then make a phone call and try to ascertain the source of the fire; this was done by

all teams. Then there was a fire hydrant in the corner of the gallery and a small fire depot which could be seen by the men when they walked into the gallery. They then found a transformer on fire and they were expected to attempt to extinguish the fire. They initially applied CO 2 extinguishers, but we wanted them to apply water to the fire because the CO 2 extinguishers were unsuccessful. Only one or two teams out of the 16 failed to make a phone call to have the power disconnected on the surface. That is how we work, we try to put the team into a hazardous situation and assess how it is handled.

Peter Robbins, NSW Mines Rescue Pty Ltd Questions and Discussion Bob Gordon, Appin Colliery Area 9 I was amazed at the amount of flames produced from the shaft when the seam contained around 4-10 m 3 / tonne. I was surprised that the gas supply to the flames seemed continuous. Peter I don t know exactly what was burning. Reports indicate the mine was running approximately 0.5% general body in the up-cast shaft at about 125 m 3 / sec ventilation quantity. A limited goaf had been formed to the rise and the inseam exploration holes were producing some gas which was captured by the gas drainage pipe range. John Coll, West Cliff Colliery Do they normally have mines with only one means of egress in New Zealand? Peter Sorry, I cannot answer that as a general comment. The NZ legislation is different from NSW. They did have a ladder way in the up-cast shaft. The drift was in stone and expected not to have roof falls or stability issues. Greg Knight, Appin Colliery If there were any long-holes in the mine and standpipes, could these have provided a source for the gas supply to the fire? Peter I don t know. The holes were naturally ventilating to a gas drainage range which went back through the pit bottom area. The line may have been broken by the explosion/s and this break could have continued to supply gas to the fire. Remember, it is up to a 10 m thick seam, so there is a lot of coal to produce gas. Greg Knight What are your thoughts now on tube bundle gas monitoring? Peter Tube bundle is good with its advantages and disadvantages and is one option for monitoring mine ventilation systems but not the only one. Pike River mine was in the early development stages and only had a small area of workings within the seam. The farthest workings were some 500 600m from the end of the drift, so it is not a big mine and they did have some real time gas monitoring points around the mine Some people have speculated that the Pike River mine should have had tube bundle installed. Personally I can t comment. However we need to remember the size of the mine. Consider there is around 2.3 km of stone access drift from the portal. A number of South Coast mines had a similar situation when they initially started, ie a drift of around 1.6 1.8 km, a shaft and a small pit bottom area in coal. You could ask the question whether those mines would

have installed a tube bundle at the start and you would have to ask if the size of the initial part of the Pike River mine warranted tube bundle. Bob Myatt, NSW Government Mines Inspector - I would like to ask the mine managers if they could think about sealing their own mines if necessary, to avoid a repeat of the Pike River experience. It would be easy to have the necessary materials available. Considering there is a MDG6002 guideline available, in draft form. It would be good for mines to conduct an exercise to see if they could overcome the issues raised in your presentation? Peter There have been two events recently which have identified that not only do you have to be able to seal a mine, but you also have to be able to check that it is actually sealed. Both events have involved ignitions of gas, here and in New Zealand. Both occurrences have shown relatively rapid success in sealing the big areas, but all the small cracks and gaps require a lot of time to be chased and sealed. When the place is sealed properly the mine atmosphere tends to go inert quickly, especially if additional artificial inertisation is being carried out. But when the seal leaks, it will be a struggle. We need to ask how do you effectively seal around a cage etc. in a shaft? Bob Kininmonth, Chairman Gas & Coal Outburst Committee From the point of view of the Committee, the Pike River explosion is an example of why we have continued these biannual seminars. We should never become complacent. Unless we do things properly and remember to do them properly, we may end up with something similar to Pike River. We have had similar problems in Australia. It is not just a New Zealand problem.