User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

Similar documents
Heavy Duty Dissolved Oxygen Meter

DOscan10 Pocket Dissolved Oxygen Tester Instruction Manual

Bante820 Portable Dissolved Oxygen Meter Instruction Manual

Bante821 Portable Dissolved Oxygen Meter Instruction Manual

Bante810 Benchtop Dissolved Oxygen Meter Instruction Manual

BI-680 Online Dissolved Oxygen Controller Instruction Manual

Instruction Manual HI Portable Waterproof Dissolved Oxygen Meter.

Dissolved Oxygen/Temp Waterproof Tester

HI 9143, HI 9143M HI 9145

Instruction Manual HI Portable Dissolved Oxygen Meter. DO meter HI 8043 STB C OFF O 2 ZERO SLOPE C. ins rum n s

Owner s Manual Humiport 10/20

OxyScan Graphic. Operating Instructions. UMS Micro-oxygen sensor 501. Microprocessor instrument

HI 2314 HI 2315 HI 23151

INSTRUCTION MANUAL. 840 Transmitter. Loop Powered Dissolved Oxygen Transmitter

In Vivo Scientific, LLC INSTRUCTION MANUAL

EC214 EC215 - EC215R Bench Conductivity Meters

SPECIFICATIONS APCEPH1

QUICK START GUIDE TO DRINKING WATER MONITORING

Instruction Manual DO 6. Economy Hand-held Dissolved Oxygen Meter. 68X Rev 2 Apr 08. Technology Made Easy... Part of Thermo Fisher Scientific

PM105 PRESSURE METER USER S MANUAL

AIR FLOW ANEMOMETER INSTRUCTION MANUAL

EM151/EM201. Electronic Manometer - + INSTRUCTION MANUAL EM Washington Street Melrose, MA Phone Toll Free

Calibration Gas Instrument INSTRUCTION MANUAL. Release I. Advanced Calibration Designs, Inc.

GE Measurement & Control

T i m i n g S y s t e m s. RACEAMERICA, Inc. P.O. Box 3469 Santa Clara, CA (408)

TEL/jlRE" Introduction. Display Features and Modes. Startup Procedure. Power-Up Procedure. Adjustment Modes

SS32L Dissolved O 2 Probe

EM151/EM201. Electronic Manometer - + INSTRUCTION MANUAL. EM201 PSI

LogIT Dissolved Oxygen Probe

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

RAM 4021 Operation Manual

A180 DO/BOD/OUR/SOUR Meter Instruction Manual

Psyclone TM. Protimeter Thermo-Hygrometer. GE Sensing. Operating Manual. INS7800, Rev. A (September 2007)

Atlas 6TM. Indoor Air Quality Monitor Instruction Manual. Measures CO 2, Temperature and Humidity DISTRIBUTED BY

Mini-Pro CO2 Sensor User s Manual - ANALOG MODEL -

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter

NEULOG OXYGEN LOGGER SENSOR GUIDE

Oxygen Sensor with Electrode

AUTOMATIC TIRE INFLATOR # MW-60, MW-60-4WAY & MW-64HP

! Warning, refer to accompanying documents.

Bante904 Benchtop Conductivity/Dissolved Oxygen Meter Instruction Manual

42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only)

DISSOLVED OXYGEN SENSOR BT34i

MARTINI. instruments. THANK YOU FOR CHOOSING. Sales and Technical Service Contacts:

YSI Model 52 Dissolved Oxygen Meter

200 PSI HIGH-FLOW AIR SOURCE KIT

200 PSI FAST-FILL AIR SOURCE KIT

MODEL NUMBER: M20005 AIR SOURCE KIT. 30% Duty Compressor on. 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE

Operation Manual. O2 Quickstick. Oxygen Analyzer

AA100 Acoustic Actuator

URC Voltage Sensor SEN-VOLT for use with MRX units containing sensor ports

120 PSI FAST-FILL AIR SOURCE KIT 25% Duty Compressor on 1.5 Gallon Air Tank

The Oxygen Sensor can be connected to all types of einstein Tablets, einstein LabMate, and einstein LabMate +.

444C DUAL PERFORMANCE VALUE PACK

450P- RV AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

MODEL NUMBER: PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank

RAM 4021-DPX Operation Manual

Operation Manual. Pro CO 2 Analyzer. Carbon Dioxide Analyzer. Rev

Optical Dissolved Oxygen Meter

OPERATOR S MANUAL Ar-Gone Weld Gas Analyzer

Advanced Test Equipment Rentals ATEC (2832)

200 PSI COMPRESSORS - MODEL NUMBERS

Operation Manual. O2 Quickstick. Oxygen Analyzer 08.17

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

210 Series Transmitter with External Electrochemical Sensor

100C Air Compressor Kit

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

Instruction Manual HI 9146 Dissolved Oxygen and Temperature Meter

Vinmetrica Dissolved Oxygen System User Manual

RAM Operation Manual

Handi+N2 OPERATING MANUAL & INSTRUCTIONS FOR USE. R218M06 Industrial. R218M06 Rev. E

Columbus Instruments

Optical Dissolved Oxygen Meter

Dissolved Oxygen Meter. ino2. Instruction Manual. Serial No..

Operating manual. TA 197 Oxi. Dissolved Oxygen Depth Armature

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

Pneumatic high-pressure controller Model CPC7000

IMPORTANT SAFETY INSTRUCTIONS

Water Quality Monitoring Using a Handheld Sonde for in situ Measurements Date Prepared: 11/17/2017

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

Digital Vacuum Regulator

Visit us at Code

CSBUOY-DT INSTRUCTION MANUAL

NOVALYNX CORPORATION MODEL WEATHER STATION INSTRUCTION MANUAL

400C & 450C DUAL PERFORMANCE VALUE PACKS

Aqua-DP. Aqua-DP Waterproof Dissolved Oxygen - ph -mv Temperature Meter. TPS Australia - Quality hand-made instruments since 1968.

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)

WTSeries C R Y S T A L. Digital Pressure Gauge. Operation Manual. engineering corporation

KJ4000 Operating Instructions & Parts Manual NSN

Instruction Manual DO 6+ Dissolved Oxygen/Temp

LM6 LEATHER MOISTURE METER

D-Opto Dissolved Oxygen Sensor Operation Manual for the D-Opto 4-20mA

Pneumatic high-pressure controller Model CPC7000

CONSERVATORY DIAGNOSTIC TOOLS TO MEASURE BUILDING PERFORMANCE

MODEL 100 NITROGEN INFLATION CART

CSA Sample Draw Aspirator Adapter Operator s Manual

USER GUIDE 1000, 2000, 2500 & 2500NV, 3000, 3500 & 3500NV, 3500DT.

THE UNIVENTOR 400 ANAESTHESIA UNIT

COMBAT SWIM BOARD. RJE International, Inc. RJE International Feb 1, TAC-300 Revision 6

Transcription:

User's Manual Heavy Duty Dissolved Oxygen Meter Model 407510

Introduction Congratulations on your purchase of Extech's Heavy Duty Dissolved Oxygen / Temperature Meter which simultaneously displays Dissolved Oxygen, Oxygen in air, and Temperature. Units of measure are mg/l for Dissolved Oxygen, % for Oxygen in air, and o C/ o F for temperature. Oxygen is measured with a remote sensor that also contains a thermistor for measuring temperature. Advanced features include RS 232 PC serial interface, data hold, auto shut off, and Min/Max/Avg recording. Specifications General Specifications Circuit Display Custom one-chip LSI microprocessor circuit Dual function 0.5" (13 mm) 1999 count LCD w/ contrast adjust Measurements Dissolved O 2 : mg/l (milligrams per liter); Oxygen in air: %; Temperature: C/ F Data hold Data hold key freezes displayed reading Sensor Structure Remote Polarographic Dissolved Oxygen Sensor Temperature sensor: Precision thermistor Data recording Min/Max/Avg readings stored for later recall Auto power off Meter turns off after 10 minutes Sample rate 0.4 Sec (approx.) Data Output RS 232 PC serial interface Operating conditions Temperature: 32 to 122 F (0 to 50 C); Humidity: < 80% RH Battery power 9V alkaline battery Power Consumption Approx. 6.6 ma DC Weight Dimensions Accessories Optional accessories 0.74 lbs. / 335 g (including batteries & probe) Main instrument: 7.1 x 2.8 x1.3" (180 x 72 x 32mm) Probe: 4.9" x 0.8" length/diameter (125 x 20mm) Carrying case, 9V battery, and 5 membranes Membranes, data acquisition software & RS232 interface cable Electrical Specifications Measurement Range Resolution Accuracy Dissolved Oxygen 0.0-19.9 mg/l 0.1mg/L + 0.4 mg/l Oxygen in air 0-100% O 2 0.1 % O 2 + 0.7% O 2 Temperature (probe only) Compensation adjustments 32 to 122 o F 0 to 50 o C 0.1 o F/C ±1.5 o F + 0.8 o C Temperature (automatic) 32 to 122 o F (0 to 50 o C) Salt 0 to 39% (1% = ppt) Altitude 0 to 3900 meters 2

Meter Description 1 LCD Display 2 POWER ON/OFF key 3 Data HOLD key 4 C/ F selection key 5 LCD Contrast Adjust 6 RECORD key 7 RECALL key 8 Factor adjust key 9 Probe top 10 Sensor body 11 Sensor plug 12 Sensor jack 13 RS-232 output jack 14 Battery cover (rear) 15 Altitude compensation key 16 O 2 Cal key 17 Zero key 18 O 2 calibration key 19 % Salt key Calibration For first time use or after long periods (several days) of non-use, calibrate the instrument using the following steps. The procedure should be performed in an open, well-ventilated area. 1. Ensure that the sensor is DISCONNECTED from the meter. 2. Turn ON the meter. 3. Slide the O 2 /DO selector to the O 2 position. 4. Press the zero key to null the meter (the display should indicate "OO"). 5. Connect the DO sensor to the top of the meter. 6. Allow the meter to stand for at least five minutes until the display stabilizes. 7. Press the O 2 Cal key and the display will indicate approx. 20.9 (typical O 2 in air). 3

Dissolved Oxygen (DO) Measurements Measurement Preparation Before taking measurements, perform the calibration described above if necessary. In addition, perform the % SALT and ALTITUDE compensation adjustments as described below: % SALT Compensation Slide the O 2 /DO switch to the DO position. If the measured liquid is pure water or is known not to have a salt content, set the % Salt factor to 0%. 1. Press the % Salt key. The display will indicate 0% on the middle portion of the LCD display and S on the bottom portion of the LCD. 2. Pressing the Factor Adj. key once will add 1% to the salt factor. 3. Press the Factor Adj. key until the correct factor is displayed. 4. Press the % Salt key to store the factor. NOTE: 1% = 10 ppt (parts per thousand) ALTITUDE Compensation The meter has a default calibration for sea level operation (0 meters). Any significant deviation from sea level requires a compensation adjustment. Perform the following steps to do so: 1. Press the ALTITUDE key and the display will indicate a 0 in the middle of the LCD and an H on the lower portion of the LCD. 2. Press the Factor Adj. key once to add 100 meters, twice to add 200 meters, and so on. Maximum compensation is 3900 meters. 3. Once the desired compensation is displayed, press the ALTITUDE key again to store the value. Taking Measurements 1. Immerse the probe in the solution under test. For best automatic temperature compensation, immerse the probe to a depth of at least 4" (10 cm). 2. Wait until the display stabilizes. 3. The velocity of the liquid coming into contact with the probe must be at least 0.6 to 1 ft/min (0.2 to 0.3 m/s). If the solution is standing, stir the solution with the probe or use an agitator. 4. Rinse the probe with clean water after each use. Oxygen in Air (O2) Measurements Follow the same steps above for DO measurements except for the variations described below: 1. Slide the O 2 /DO switch to the O 2 position. 2. The display will indicate the oxygen air value in %. Temperature Measurements The lower display will indicate the temperature of the measured solution. Press the o C/ o F key to change the temperature units. 4

Advanced Features Data Hold Press the Data Hold key to freeze the displayed value. The LCD will display DH for Data Hold mode along with the held reading. Press the Hold key again to release the data hold function. MIN/MAX/AVG Data Recording When selected, the Data Recording function records the Min, Max, and Average readings. To start a data recording session: 1. Press the RECORD key once. The REC indicator will appear on the display and the meter will begin to record the lowest (min), highest (max), and average (avg) readings. 2. To recall the data, press the RECALL key once. The MAX indicator will appear along with the highest reading recorded since the RECORD key was pressed. 3. Press the RECALL key again to view the MIN value. 4. Press the RECALL key again to view the AVG reading. 5. To exit the Record mode, press the RECORD key again. The display indicators REC, MIN, MAX, and AVG will disappear. Auto Power OFF The meter includes an Auto shut off feature that preserves battery life. The meter will automatically turn off if no function button is pressed in any 10 minute period. To disable this feature press the RECORD key to engage the record function. LCD Contrast Adjust It may be necessary to adjust the display contrast due to a change in viewing angle or voltage drift. Use the LCD Contrast adjustment located on the right side of the meter to set the preferred contrast. CPU Reset Certain improper keystroke sequences can cause the meter to hang and become inoperable. The following procedure will reset the meter. 1. Slide the O 2 /DO switch to the O 2 position. 2. Turn the meter OFF and disconnect the DO probe. 3. Press and HOLD the O 2 CAL key and then press the POWER key. 4. Release the O 2 CAL key and then press the ZERO key. 5. Connect the DO probe. 6. Wait several minutes for the reading to stabilize and then press the O2 CAL key. RS-232 PC Interface The meter includes a RS-232 serial data port. This interface was designed to operate with the Extech Data Acquisition Software/Hardware kit Part No. 407001. This kit enables the user to capture, store and display readings using a PC. 5

Membrane & Electrolyte Replacement The tip of the probe holds a thin Teflon membrane and an electrolyte container. Calibration or reading errors could indicate loss of electrolyte or a dirty/damaged membrane. The membrane is very delicate and can easily be damaged if it comes in contact with solid objects. Replace the electrolyte or the membrane as follows: 1. Unscrew the probe head and electrolyte container from the probe handle and drain the old electrolyte 2. Unscrew the probe head. 3. Remove the white O-ring, remove the old membrane and then carefully install the new membrane and secure with the O ring. 4. Replace the probe head onto the electrolyte container. 5. Fill the electrolyte container with new electrolyte. 6. Screw the tip and well assembly back onto the probe handle. Excess electrolyte may be forced out through the threads. Wipe clean. 7. Lightly tap the probe to remove any air bubbles. 1. Probe handle 2. Temperature sensor 3. Electrode holder 4. Electrolyte container 5. Diaphragm 6. O-ring 7. Probe head 6

Battery Replacement The low battery indication LBT appears on the LCD when the battery runs low. To replace the battery: 1. Remove the meter's rubber protective cover to access the rear battery compartment. 2. Remove the battery compartment cover using a small coin or screwdriver and remove the 9V battery. 3. Replace the 9V battery and reinstall the cover and holster. Calibration and Repair Services Extech offers repair and calibration services for the products we sell. Extech also provides NIST certification for most products. Call the Customer Service Department for information on calibration services available for this product. Extech recommends that annual calibrations be performed to verify meter performance and accuracy. Warranty EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for one year from date of shipment (a six month limited warranty applies to sensors and cables). If it should become necessary to return the instrument for service during or beyond the warranty period, contact the Customer Service Department at (781) 890-7440 ext. 210 for authorization or visit our website www.extech.com for contact information. A Return Authorization (RA) number must be issued before any product is returned to Extech. The sender is responsible for shipping charges, freight, insurance and proper packaging to prevent damage in transit. This warranty does not apply to defects resulting from action of the user such as misuse, improper wiring, operation outside of specification, improper maintenance or repair, or unauthorized modification. Extech specifically disclaims any implied warranties or merchantability or fitness for a specific purpose and will not be liable for any direct, indirect, incidental or consequential damages. Extech's total liability is limited to repair or replacement of the product. The warranty set forth above is inclusive and no other warranty, whether written or oral, is expressed or implied. Support line (781) 890-7440 Technical support: Extension 200; E-mail: support@extech.com Repair & Returns: Extension 210; E-mail: repair@extech.com Product specifications subject to change without notice For the latest version of this User s Guide, Software updates, and other up-to-the-minute product information, visit our website: www.extech.com Extech Instruments Corporation, 285 Bear Hill Rd., Waltham, MA 02451 Copyright 2005 Extech Instruments Corporation. All rights reserved including the right of reproduction in whole or in part in any form. 7