Navigator 500 Dissolved oxygen analyzer. Measurement made easy. Accurate and reliable measurement of dissolved oxygen in high purity water

Similar documents
FICHA TÉCNICA DE PRODUTO

9408 Series Dissolved Oxygen Systems. Dissolved oxygen systems designed for reliable operation with minimal operating costs

ABB MEASUREMENT & ANALYTICS DATA SHEET series Dissolved oxygen systems

ABB MEASUREMENT & ANALYTICS DATA SHEET. AP100 ph/redox (ORP) cartridge sensors with water-wash option

Aztec ADS430 EZCLEAN Compressed air supply unit

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter

AK100 Series ATEX Compliant Gas Analyzer System for Hydrogen-cooled Alternators

ABB MEASUREMENT & ANALYTICS DATA SHEET. Endura AZ40 Oxygen and carbon monoxide equivalent (COe) analyzer

BUBBLER CONTROL SYSTEM

DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES

BUBBLER CONTROL SYSTEM

DF-310E PROCESS ANALYSERS APPLICATIONS FEATURES

ABB MEASUREMENT & ANALYTICS DATA SHEET. AK100 Series ATEX compliant gas analyzer system for hydrogen-cooled alternators

Series 6517 Katharometers. The ideal equipment for Process Monitoring and Control. Robust no moving parts. Designed for continuous industrial use

combustion efficiency monitoring General Purpose Applications Flue gas oxygen analyzers Combustion & Environmental Monitoring An Company

Pneumatic high-pressure controller Model CPC7000

combustion efficiency monitoring Flue gas oxygen analyzers General Purpose Applications Combustion & Environmental Monitoring

ABB MEASUREMENT & ANALYTICS DATA SHEET. WaterMaster FEW530 Electromagnetic water meter

Pneumatic high-pressure controller Model CPC7000

SonoMeter 30 Energy Meters

Autocalibration Systems For In Situ Oxygen Analyzers

Optical Dissolved Oxygen Meter

HumiSys HF High Flow RH Generator

Precision digital pressure gauge Model CPG1000

JUMO dtrans O2 01 Two-wire Transmitter for dissolved oxygen (DO)

Zirconia Oxygen Analyzer Systems

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

Supplementary Operator s Manual 42/24-14 EN Rev. 3

UKAS calibration laboratory 8809 Temperature, pressure and electrical signals calibration guide

Oxygen Measurement Systems High Reliability and Wide Application Coverage

FAS-W. Features. Applications. Automatic condensation hygrometer

Series Environmental Chambers

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

Plasma. Argon Production Helium Liquefaction Truck Loading Pure Gas Bottling

MEGAS 2.0. Gas analysis with direct C-Level Calculation and Bus-Connection. Data sheet

Electronic gas volume corrector model DGVC-04

TransPort PT878GC Panametrics Portable Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features

TransPort PT878GC Panametrics Ultrasonic Portable Gas Flowmeter. GE Infrastructure Sensing. Features. Applications

XMO2. Panametrics Smart Oxygen Analyzer. Applications. Features. bhge.com. An oxygen transmitter for use in:

Expert Hydrostatic Level Transmitters

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

Additel 761 Automated Pressure Calibrators Selection Guide

OxyScan Graphic. Operating Instructions. UMS Micro-oxygen sensor 501. Microprocessor instrument

Additel 780 Series Pressure Controller

Flow and Energy Measurement F-5400 THERMAL MASS FLOW METER

2600T Series Pressure Transmitters Plugged Impulse Line Detection Diagnostic. Pressure Measurement Engineered solutions for all applications

PRODUCT CONFORMITY CERTIFICATE

Oxymax COS61/COS61D. Technical Information

Industrial pressure controller Model CPC4000

Additel 761 Automated Pressure Calibrators Selection Guide

Additel 761 Automated Pressure Calibrators

HUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation

dtrans O2 01 Two-wire Transmitter for dissolved oxygen (DO)

Optical Dissolved Oxygen Meter

Differential Pressure Transmiter

Additel 761 Automated Pressure Calibrators

Model EXAxt AV550G. Averaging Oxygen Analyzer

Model GFC 7000T CO 2 Analyzer (Addendum to GFC 7000TA Manual, PN 07272)

Precision pressure sensor Basic version Model CPT6020

Pressure Automated Calibration Equipment

Service Calibration are you doing it properly?

GasSense NDIR User Manual

CO, NO, NO 2, NO x, SO 2, CH 4, HCl, CO 2 & H ² O. Extractive low cost, low maintenance devices for continuous process and emissions monitoring.

Additel 780 Series Pressure Controller

F&J SPECIALTY PRODUCTS The nucleus of quality air monitoring programs

Benefits. Rev.III_032018_Oxybaby 6.0_engl subject to technical alterations

Sensor for Air Bubble Detection at Liquid Filled Tubes. SONOCHECK Type ABD06.xx. Operating Manual

ATS430 turbidity sensor Retractable insertion assembly

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

Ultrasonic level transmitter and indicator

C-Flow Coriolis Mass Flow Meters

EPP4 Pressure Regulator Basic G 1/4"

The HumiPyc - Model 1 - Gas Pycnometer; Density, Moisture, Permeation Analyzer; RH sensor Calibrator

TEK-THERMAL 1700B. Thermal Mass Flowmeter. FLOW. Technology Solutions

The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions

Navigator 600 Silica analyzers

UBEC 1AT. AUTO TANK Fill System Installation, Operation, & Setup Instructions

Features. Description

Additel 761 Automated Pressure Calibrators

Autocalibration Systems for In Situ Oxygen Analyzers

AMT-Ex Dewpoint Transmitter

Automatic Isokinetic Sampler. ST5 Evo

Level transmitters and indicators Series LU Ultrasonic level transmitter and indicator for liquids and solids

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

TH-1800-T TRX-700-CNG Converter

Integral type Differential pressure flowmeter VNT Series

High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20

The benefits of the extended diagnostics feature. Compact, well-proven, and flexible

GAS ANALYSER OXYBABY 6.0 for O 2. or O 2 /CO 2

ABB measurement & analytics data sheet. JAA, JAF and JAG Pneumatic indicating controllers

Basic Nitriding Sampling System Hydrogen Analyzer with Calculated % DA, % NH 3, and K N Values. Operations Manual

PositionMaster EDP300 Extended Diagnostics. Compact, well-proven, and flexible

ACV-10 Automatic Control Valve

Pressure transmitter PASCAL Ci4

AIR FLOW CALIBRATORS Single Sensor Designs

Endura AZ40 Transmitter Main board spares kit

CoriolisMaster mass flowmeter Diagnostics, verification and proof test

Instruction Manual. Biogas Analyzer InCa Bio 04

High-performance submersible pressure transmitter For level measurement Model LH-20

Transcription:

Data sheet DS/ADS550 EN Rev. C Navigator 500 Dissolved oxygen analyzer Measurement made easy Accurate and reliable measurement of dissolved oxygen in high purity water Monitors both low and high dissolved oxygen concentrations suitable for measurement during two-shifting and baseload operations on power stations Automatic calibration minimizes manual intervention and protects sensor during calibration Fast response reacts quickly to rapid changes in plant conditions Disposable sensor minimizes down time and avoids the need for skilled personnel to carry out sensor refurbishment Comprehensive diagnostics provides sensor condition and analyzer status data Connect multiple wet-sections to a single transmitter reduces footprint and installation costs Thermal protection protects sensor in the event of cooling water failure

Navigator 500 Dissolved oxygen analyzer The Navigator 500 range The Navigator 500 range of analyzers from ABB are designed for high purity water treatment applications and power cycle chemistry monitoring. The analysis and signal conditioning is conducted within the Navigator 550's advanced wet-section that houses the sensing technology. The accurate measurement result is transmitted digitally to the Navigator 540 transmitter. The Navigator 540 universal transmitter enables connection of up to 4 different Navigator 550 wet-sections and is available with optional features such as SD card data retrieval and graphical trending, as well as additional outputs and communication options. The following parameters are available in the Navigator 500 range: Navigator 500 dissolved oxygen analyzer The Navigator 500 dissolved oxygen analyzer provides continuous monitoring and control of power station boiler feed water / steam condensate. The wet-section houses ABB's maintenance-free electrochemical cell that accurately measures the amount of dissolved oxygen in the water. Measurement results are updated digitally to the Navigator 540 transmitter where process trends of up to 4 separate wet-sections can be viewed locally on the color display. Users of this system also benefit from the anayzer's low maintenance requirements, ease-of-use, auto-calibration and proven sensing performance. Process data, together with the content of alarm and audit logs within the transmitter, can be saved to a removable media for record keeping and analysis using ABB's DataManager Pro data analysis software. Navigator 500 Sodium Dissolved Oxygen Hydrazine Navigator 540 transmitter Navigator 550 wet-sections Sodium Hydrazine DIssolved Oxygen Sodium Hydrazine Dissolved Oxygen Fig. 1: Navigator 500 family 2 DS/ADS550 EN Rev. C Navigator 500 Dissolved oxygen analyzer

Applications Typical applications for the Navigator 500 dissolved oxygen analyzer include: Protection against corrosion caused by excessive dissolved oxygen concentrations Deaerator efficiency indication Hydrazine dosing efficiency indication Low level dissolved oxygen on boiler plant The need for accurate monitoring Accurate measurement of dissolved oxygen is essential for efficient, cost-effective operation of boiler plant. In its dissolved form, oxygen is highly corrosive to most metals, especially the mild steel used for boiler tubes. The presence of even small quantities of dissolved oxygen in boiler water can severely impair a boiler's operation, causing corrosion of its vital components and significantly reducing its working life. To minimize damage caused by corrosion, it is therefore necessary to reduce dissolved oxygen to the lowest possible level, typically in the order of seven parts per billion or less. In some applications, particularly those operating once-through boilers, it is preferable to add oxygen to the boiler feedwater, causing a layer of soft haematite to form on the boiler tubes. Hydrazine is then added that reacts with the haematite, converting it to a hard layer of magnetite that protects the tubes from further corrosion. Monitoring should be carried out wherever there is a risk of oxygen ingress into the boiler feedwater. An effective system monitors dissolved oxygen at key points including the extraction pump discharge, the deaerator inlet and outlet and the economizer or boiler inlet. The Navigator 500 solution The significant variations in oxygen levels during the load cycle of a plant, combined with the different levels required for different boiler chemistry regimes, require an analyzer that offers a fast response across both high- and low-level dissolved oxygen concentrations. The Navigator 500 dissolved oxygen analyzer uses a galvanic-type sensor to accurately measure dissolved oxygen levels in process feed water. Accurate and reliable, it requires no maintenance and can measure dissolved oxygen concentrations up to 20 ppm. Featuring a separate wet-section and transmitter, the Navigator 500 dissolved oxygen analyzer gives users the option of adding up to 4 wet-sections to one transmitter, enabling measurement of samples from different points in the boiler feedwater line. This feature also allows users to mix-and-match different sensor types from the Navigator 550 range of hydrazine and sodium wet-sections. Navigator 500 Dissolved oxygen analyzer DS/ADS550 EN Rev. C 3

Navigator 500 Dissolved oxygen analyzer Overview of Navigator 500 dissolved oxygen analyzer Chart View Ch1 0.0 Ch2 3.0 Ch3 3.0 Ch4 3.0 10:42:19 19 11:12:19 12 19 11:42:19 19 2013-01-31 2013-01-31 2013-01-31 2013 01 31 11:42:29 10000 7500 5000 2500 0 CAL 2013 01 31 Audit Log 10:31:27 No. Event Date Time 01 Power Failure 2013-01-31 11:14:18 02 Power Recovery 2013-01-31 09:29:39 03 Power Failure 2013-01-23 12:30:29 04 Power Recovery 2013-01-21 12:29:44 CAL Transmitter Simple navigation and easy-to-use menu system Graphical trending Measurement trends of each connected wet-section can be easily and clearly viewed locally on the graphical color display Full audit trail logs Diagnostic messages, alarm events, calibration details and system activity are stored in the transmitter audit logs for review Smart board Stores sensor calibration data and calculates measurement result Integrated flowmeter and flow regulating valve Simplifies installation and analyzer set-up procedure SD card or USB archiving Data recorded in the transmitter's internal memory can be archived to a removable Secure Digital (SD) card or USB stick Flexible communications A user-configurable range of outputs and communication options are available including Ethernet connectivity Automatic calibration Verifies analyzer performance Continuous dissolved oxygen measurement using ABB electrochemical cell Maintenance free, disposable dissolved oxygen sensor mounted in flow cell with temperature sensor 4 DS/ADS550 EN Rev. C Navigator 500 Dissolved oxygen analyzer

Navigator 540 transmitter Navigator 550 dissolved oxygen wet-section Features and benefits of the Navigator 540 transmitter include: Connect multiple wet-sections to a single transmitter Mix-and-match up to 4 different single-stream wet-sections in the Navigator 500 range The Navigator 550 dissolved oxygen wet-section has been designed to be used in conjunction with the Navigator 540 transmitter either alone or in combination with other Navigator 550 wet-sections. 'Plug-n-play' capability Automatic wet-section recognition and configuration Simple to operate Intuitive navigation through the operator menus with ABB's standardized 6-key layout Password protected security Dual access level security, enabling separate user access levels to basic and advanced settings Navigator 500 Dissolved oxygen analyzer DS/ADS550 EN Rev. C 5

Navigator 500 Dissolved oxygen analyzer Accurate and reliable measurement The Navigator 500 dissolved oxygen analyzer has been designed for ease-of-use and maintenance simplicity, while offering the benefits of flexible communication and advanced data acquisition. Measuring principle The Navigator 500 dissolved oxygen analyzer uses a disposable galvanic cell in a custom-designed flow cell. Sample flow is adjusted easily by a flow regulating needle valve and monitored by an optional flowmeter. A temperature sensor, fitted in the flowcell, measures the temperature of the sample. The signal from the dissolved oxygen sensor and the temperature sensor is passed to the smart board located within the Navigator 550 wet-section. The smart board accurately calculates the dissolved oxygen measurement result and transfers it digitally to the Navigator 540 transmitter. Maintenance-free disposable sensor ABB dissolved oxygen sensors are maintenance-free and long lasting. Their encapsulated design removes the requirement for time-consuming maintenance such as membrane changes or electrolyte replenishment. The easy replacement procedure for the maintenance-free DO sensor just takes seconds, saving further valuable time and cost. Simple automatic calibration The Navigator 500 dissolved oxygen analyzer features automatic calibration that verifies the analyzer's performance and calculates sensor efficiency. During calibration the sample is diverted, exposing the dissolved oxygen sensor to air. Navigator 2.9 Air Calibration Calibrating ppb Once the calibration routine is complete, sensor efficiency is calculated and displayed, providing the user with a valuable indication of sensor life. >85 % Efficiency (green) >70 % Efficiency (green) >60 % Efficiency (green) >50 % Efficiency (green) >40 % Efficiency (green) 2012 08 16 10:52:35 Calibration pass <40 % Efficiency (red) Calibration fail The frequency of automatic calibration can be scheduled by the user to occur from daily to bi-monthly intervals. Calibration can also be initiated manually by the operator. S1 CAL Fig. 2: Easy sensor replacement 6 DS/ADS550 EN Rev. C Navigator 500 Dissolved oxygen analyzer

Optional flowmeter Red Blue Flow regulating needle valve (if applicable Pt1000 temperature compensator sensor Sample in Solenoid operated valve closed Manual override button Solenoid operated valve open Sample in Drain Flow during normal operation Flow during calibration or thermal overload condition Fig. 3: Flow conditions Navigator 500 Dissolved oxygen analyzer DS/ADS550 EN Rev. C 7

Navigator 500 Dissolved oxygen analyzer Specification system Operation Measuring range 0 to 20,000 ppb Units of measure ppb, µg/l, µg/kg Accuracy ±5 % of reading or ±1 ppb, whichever is the greater Repeatability ±3 % of reading or ±1 ppb, whichever is the greater Response time 1 minute for a 90 % step change Resolution 0.1 ppb Temperature compensation 5 to 55 C (41 to 131 F) automatic using a Pt1000 Salinity correction Preset within the range 0 to 80 ppt Barometric pressure correction Preset within the range 500 to 800 mm Hg AutoCal frequency Programmable from 1 to 7 days or 1 to 8 weeks Sample temperature 5 to 55 C (41 to 131 F) Sample pressure 2 bar gauge (29 psi) maximum Sample flow rate 100 to 300 ml/min Sample connections 1 /4 in. or 6 mm OD pipe (stainless steel recommended) Environmental data Ambient operating temperature: 0 to 55 ºC (32 to 131 ºF) Ambient operating humidity: Up to 95 % RH non-condensing Storage temperature: 20 to 70 C ( 4 to 158 F) without sensor 0 to 55 C (41 to 131 F) with sensor Approvals, certification and safety CE mark UL (pending) CSA (pending) General safety EN61010-1 Pollution category 2 Insulation category 2 EMC Emissions & immunity Meets requirements of IEC61326 for an industrial environment and domestic emissions Maintenance Periodic calibration: User-defined Specification wet-section Mechanical data Protection IP54 Dimensions Height: 480 mm (18.90 in) Width: 290 mm (11.41 in) door shut Depth: 185 mm (7.28 in) door closed minimum (excluding fixing brackets) Weight: 4.5 kg (10 lb) Electrical Power supply ranges (supplied by transmitter) 24 V DC max. Power consumption 8 W max. 8 DS/ADS550 EN Rev. C Navigator 500 Dissolved oxygen analyzer

Specification transmitter Operation Display 89 mm (3.5 in) color 1 /4 VGA TFT, liquid crystal display (LCD) with built-in backlight and brightness / contrast adjustment Language English, German, French, Italian, Spanish Keypad 6 tactile membrane keys: Group select / left cursor, view select / right cursor, menu key, up, down, enter key No of inputs Up to 4 single-stream or 1 multi-stream wet-section Mechanical data Protection IP66 / NEMA 4X Dimensions Height: 194 mm (7.64 in) minimum (excluding glands) Width: 214 mm (8.42 in) excluding glands Depth: 98 mm (3.85 in) door closed minimum (excluding fixing brackets) Weight: 1.5 kg (3.3 lb) Materials of construction Glass-filled polycarbonate Security Password protection Calibrate and Advanced user-assigned Service level access factory-set Electrical Power supply ranges 100 to 240 V AC max., 50 / 60 Hz ±10 % (90 to 264 V AC, 45/65 Hz) Power consumption <10W Analog outputs 2 standard 2 optional Galvanically isolated from the rest of the circuitry, 500 V for 1 minute. Range-programmable source and range 0 to 22 ma, maximum load 750 @ 20 ma Relay outputs 4 standard 2 optional Fully-programmable. Contacts rated at 5A @ 110 / 240 V. Standard relays are changeover. Optional relays are normally closed (). Digital inputs / outputs 6 standard, user-programmable as input or output Minimum input pulse duration: 125 ms Input: volt-free or 24 VDC (conforms to IEC 61131-2) Output: open-collector, 30 V, 100 ma max. (conforms to IEC 61131-2 Connectivity / communications Ethernet (optional) TCP/IP, HTTP Data logging Storage Measurement value storage (programmable sample rate) Audit Log*, Alarms Log*, Calibration log, Diagnostics log, Configuration changes Chart view On local display Historical review Of data Data transfer SD card interface / USB stick Windows-compatible FAT file system, data and log files in Excel and DataManager Pro compatible formats Terminal connections rating AWG 26 to 16 (0.14 to 1.5 mm 2 ) *Audit Log and Alarm Log data are stored in the same log file. Navigator 500 Dissolved oxygen analyzer DS/ADS550 EN Rev. C 9

Navigator 500 Dissolved oxygen analyzer Overall dimensions Transmitter Dimensions in mm (in.) 213 (8.38) 214 (8.42) 200 (7.87) fixing centers 98 (3.85) 66 (2.6) 194 (7.64) fixing centers 62 (2.44) 66 (2.40) Ø62 (2.44) Cable gland kit (optional) Cable gland kit (optional) Pipe diameters: max. 62 (2.44) / min. 45 (1.77) Pipe-mount kit (optional) Vertical configuration Horizontal configuration 10 DS/ADS550 EN Rev. C Navigator 500 Dissolved oxygen analyzer

Wet-section Dimensions in mm (in.) Navigator 500 Ø 7 (0.27 in.)* 386 (15.19 in.) 480 (18.90 in.) Ø 7 (0.27 in.)* 210 (8.27 in.) 185 (7.28 in.) 281 (11.06 in.) 37 (1.45 in.) 290 (11.41 in.) 80.2 (3.15 in.) Navigator 500 Dissolved oxygen analyzer DS/ADS550 EN Rev. C 11

SK1 SK2 RS485 SMART SENSOR INTERFACE MODULE CM40/0215 ISS.1 RED INT +24V DIO1 DIO2 DIO3 DIO4 DIO5 DIO6 I/O MODULE 2 I/O MODULE 3 1 2 3 4 5 + + MS OUT 1 OUT 2 RELAY 1 RELAY 2 RELAY 3 RELAY 4 SK4 ANALOGUE OUTPUT BOARD CM40/0235 + + SK5 OUT 3 OUT 4 RELAY RELAY 5 6 N L Navigator 500 Dissolved oxygen analyzer Electrical connections Transmitter I/O module 1 (shown fitted) Optional communications module (PROFIBUS or Ethernet) MUNICATIONS MODULE BLACK SCREEN WHITE GREEN DIO FUSE RATING 3.15A (T) ~100 240V 50/60 Hz I/O module 3 option card (shown fitted) SK1 MUNICATIONS MODULE SK2 RS485 SMART SENSOR INTERFACE MODULE CM40/0215 ISS.1 RED BLACK SCREEN WHITE GREEN SK4 ANALOGUE OUTPUT BOARD CM40/0235 SK5 OUT 3 OUT 4 RELAY 5 + + RELAY 6 I/O MODULE 3 FUSE RATING 3.15A (T) ~100 240V 50/60 Hz Analog outputs 3 and 4 (optional) Relay connections 5 and 6 (optional) 1 2 3 4 5 + + INT +24V DIO1 DIO2 DIO3 DIO4 DIO5 DIO6 DIO MS OUT 1 OUT 2 N/O N/O N/O N/O RELAY 1 RELAY 2 RELAY 3 RELAY 4 N L Comms connections (PROFIBUS or Ethernet) Digital I/O connections Analog output connections 1 and 2 (standard) Relay connections 1 to 4 (standard) Mains supply 100 V to 240 V AC ±10 % (90 V min. to 264 V max.) 50 / 60 Hz Wet-section terminal connections Fuse 3.15 A Type T 100 to 240 V, 50/60 Hz 12 DS/ADS550 EN Rev. C Navigator 500 Dissolved oxygen analyzer

Digital I/O, relays and analog output N/O Relays (1 to 4) Load L N Relays (5 and 6) Load N L INT +24 V (100 ma max.) DIO 1 to 6 Load Load L Analog outputs (1 to 4) Digital input (24 volt) Digital input (voltage-free) + INT +24 V DIO 1 to 6 750 Max. DIO 1 to 6 DIO DIO Chart recorder Wet-section (applicable only to multiple wet-section systems) B R SCR G W Additional serial cable connections to multiple wet-sections Red R (24 V) Black B (0 V) Green G (Data +ve) White W (Data ve) Screen SCR Navigator 500 Dissolved oxygen analyzer DS/ADS550 EN Rev. C 13

Navigator 500 Dissolved oxygen analyzer Ordering Information Wet-section Navigator 500 dissolved oxygen analyzer ADS550/ X X X X XX XX XX XXX XX XX Build revision Reserved A Measurement range Standard (0 to 20,000 ppb) 1 Enclosure type Wall W Number of streams Single stream 1 Sensor type Standard Supplied without sensor S1 Y0 Process connection type 6 mm fitting 1 /4 in. fitting A1 B1 Optional ordering codes Add 1 or more of the following codes after the standard ordering information to select any additional options. Sample measurement options Sample flow measurement S1 Signal cable length and type (supplied without signal cable as standard) 1.5 m (approx. 5 ft) cable, terminal connection SC1 5 m (approx. 15 ft) cable, terminal connection SC2 10 m (approx. 30 ft) cable, terminal connection SC3 20 m (approx. 60 ft) cable, terminal connection SC4 Test certificate Test certificate CD Documentation language * (supplied in English as standard) German Italian Spanish French English * Commissioning instructions are supplied with each transmitter. Comprehensive operating instructions are available as a free download from www.abb.com or printed copies can be ordered as additional items. M1 M2 M3 M4 M5 14 DS/ADS550 EN Rev. C Navigator 500 Dissolved oxygen analyzer

Transmitter Navigator 540 transmitter AWT540/ X X X X XX XX XX XX XX XX XX XX XX Build revision Reserved A Enclosure type Wall mount 1 Display type Color (standard) A Power supply 90 to 260 V AC, 50 to 60 Hz 1 Channel 1 Digital, wired sensor connection Without B1 Y0 Reserved Y0 Reserved Y0 Output signal Without Additional output card (2 current outputs + 2 relays) Ethernet Profibus DPV1 Y0 Y2 E1 D1 Data storage Without SD card function USB function Y0 D1 D8 Optional ordering codes Add 1 or more of the following codes after the standard ordering information to select any additional options. Accessories Panel mount kit A2 Test certificate Test certificate CD Documentation language * (supplied in English as standard) German M1 Italian M2 Spanish M3 French M4 English M5 Cable entry options Metric gland pack (9 glands) * Commissioning instructions are supplied with each transmitter. Comprehensive operating instructions are available as a free download from www.abb.com or printed copies can be ordered as additional items. U1 Navigator 500 Dissolved oxygen analyzer DS/ADS550 EN Rev. C 15

Contact us ABB Limited Process Automation Oldends Lane Stonehouse Gloucestershire GL10 3TA UK Tel: +44 1453 826 661 Fax: +44 1453 829 671 ABB Inc. Process Automation 125 E. County Line Road Warminster PA 18974 USA Tel: +1 215 674 6000 Fax: +1 215 674 7183 Note We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB. Copyright 2014 ABB All rights reserved 3KXA494550R1001 DS/ADS550 EN Rev. C 03.2014 www.abb.com Sales Service Software