Oxygen Meter User Manual

Similar documents
OC508 Programmable mv Calibrator

RM-80 respiration monitor

Technology. In the My Files [My Files] submenu you can store all the programs that you have made on the NXT or downloaded from your computer.

D-Opto Dissolved Oxygen Sensor Operation Manual for the D-Opto 4-20mA

Diver-Office. Getting Started Guide. 2007, Schlumberger Water Services

Technology. Using Bluetooth

Technology. Using Bluetooth

DeeterFlow Automatic Liquid Dispenser

FireHawk M7 Interface Module Software Instructions OPERATION AND INSTRUCTIONS

Bante821 Portable Dissolved Oxygen Meter Instruction Manual

Instruction Manual. BZ7002 Calibration Software BE

Optical Dissolved Oxygen Meter

Quick Start Guide. A. Hardware installation B. Software installation C. Start the software for the first time D. Do your first measurement

D-Opto Dissolved Oxygen Sensor Operation Manual

Electronic gas volume corrector model DGVC-04

D-OptoLogger Dissolved Oxygen Logger Operation Manual

CONSUMER MODEL INSTALLATION GUIDE

Race Screen: Figure 2: Race Screen. Figure 3: Race Screen with Top Bulb Lock

OxyScan Graphic. Operating Instructions. UMS Micro-oxygen sensor 501. Microprocessor instrument

Figure SM1: Front panel of the multipatcher software graphic user interface (GUI) at the beginning of multipatcher operation.

Setting up the Ingenico isc250 Pinpad via USB in Windows 8

Q2: Which instruments are necessary for monitoring the groundwater level?

DST Host User Manual

Version 3.1.0: New Features/Improvements: Improved Bluetooth connection on Windows 10

D-Opto. Dissolved Oxygen Sensor. Operation Manual (Software Version 1.0)

Optical Dissolved Oxygen Meter

AUTO PUMP STATUS CENTER

GA-300 Gas Analyzer. Technical Note. Overview. Front Panel. iworx Systems, Inc. GA-300

Previous Release Notes

EPP4 Pressure Regulator Basic G 1/4"

AIR FLOW ANEMOMETER INSTRUCTION MANUAL

The NXT Generation. A complete learning solution

Quintic Automatic Putting Report

Revision: 23 March 2008 (nk)

KEM Scientific, Inc. Instruments for Science from Scientists

Using the Lego NXT with Labview.

WeatherStation Powerboat Model PB100 Owner s Guide

SCIENTIFIC DATA SYSTEMS, INC. Depth Tension Line Speed Panel. DTLS Manual

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

DDR Dive Data Recorder Manual - Rel /12

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

New product release. Universal Rebreather Monitor (URBM) Three cell / Independent backup

Laboratory 2(a): Interfacing WiiMote. Authors: Jeff C. Jensen (National Instruments) Trung N. Tran (National Instruments)

TEL/jlRE" Introduction. Display Features and Modes. Startup Procedure. Power-Up Procedure. Adjustment Modes

Heavy Duty Dissolved Oxygen Meter

FOOD INTAKE MONITOR. Hardware and Software User s Manual DOC-047 Rev 3.0. Copyright 2009 All Rights Reserved

NEULOG OXYGEN LOGGER SENSOR GUIDE

TR Electronic Pressure Regulator. User s Manual

GAS ANALYSER OXYBABY 6.0 for O 2. or O 2 /CO 2

Operating Manual. SUPREMA Calibration. Software for Fire and Gas Warning Units. Order No.: /01. MSAsafety.com

MASK INTEGRITY TEST ACCESSORY (MITA) MODEL 8120

APPLICATION NOTES DELOMATIC 4, DM-4 GAS

ALGE DIVE! ALGE. ALGE-TIMING GmbH & Co

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter

Experiment AMe-1: Small Animal Respiratory Exchange Ratio (RER)

Pegas 4000 MF Gas Mixer InstructionManual Columbus Instruments

AX5000 Operational Manual

Digi Connect ME 9210 Linux: 2 nd serial over FIM

Operator Quick Guide ORBISPHERE 3654

New product release. Universal Rebreather Monitor (URBM) Single O2 cell and Dual HP package

APA software instruction manual

Gas Analyzer for TC Sensors (CO2, H2, N2) Series 62101, 64101, Operating Manual

Setting Up the Ingenico isc250 Pinpad via USB

Blackwave Dive Table Creator User Guide

1001ICT Introduction To Programming Lecture Notes

A180 DO/BOD/OUR/SOUR Meter Instruction Manual

SHIMADZU LC-10/20 PUMP

PRODUCT MANUAL. Diver Smart Interface Cable AS346

INSTALLATION INSTRUCTIONS AND REFERENCE HANDBOOK

Shearwater GF Computer

WELCOME TO THE REVOLUTION

Callaway upro Golf GPS. User Guide (v1.3) 2009 Callaway Golf Company

Quadruple mass spectrometers (transducer type)

Precision digital pressure gauge Model CPG1000

SonoMeter 30 Energy Meters

Aqua-DP. Aqua-DP Waterproof Dissolved Oxygen - ph -mv Temperature Meter. TPS Australia - Quality hand-made instruments since 1968.

PC Configuration software for Discovery MkVI v 1.03 User guide

TOMI PRO MODEL PERSONAL MODEL

Additel 780 Series Pressure Controller

OPERATION MANUAL DIVE CALIPER NOT SCALE / IF IN DOUBT ASK* *ALL UNITS IN MM/DEGREES UNLESS SPECIF. Dive Caliper General DC-051

Section 1: Overview... 6 Features... 6 Supported Software Part 1: Getting Started 7

Operating instructions for. For visualization of your measurements

ELIMINATOR COMPETITION DRAG RACE Program Manual Firm Ver 4.11

Kestrel HVK Gun Loader Sofware

MoLE Gas Laws Activities

BI-680 Online Dissolved Oxygen Controller Instruction Manual

CCT-7320/ROC-2313 Reverse Osmosis Controller

Getting Started with the LabVIEW Toolkit for LEGO MINDSTORMS NXT

Pneumatic high-pressure controller Model CPC7000

HumiSys HF High Flow RH Generator

GyroTracer. Operating Manual. North Seeking Gyroscope (Wire line mode) Version

CONSOLE-320 ENGLISH. 230A: CONSOLE-320 with cable data output Item 230B: CONSOLE-320 with cable + wireless radio data output

Experiment C-6 Gas Solubility

Please note. Right now, the ongoing version of emax (3.9C) is not already completely compatible with the newest firmware version of Shimano!

PRODUCT MANUAL. Diver-Mobile for Android

Overview. Front Panel: Keypad and Display

ECL Comfort 110, application 131 (valid as of software version 2.00)

MEGAS 2.0. Gas analysis with direct C-Level Calculation and Bus-Connection. Data sheet

SENSUS PRO MANAGER (for SENSUS or SENSUS PRO devices) User s Guide Palm OS. Version 2.0 Published October 17, ReefNet Inc.

JOLLY2. Installation user s manual. 6 different operating modes selectable. version 3.3. DATA TO BE FILLED OUT BY THE INSTALLER (Page 1)

Transcription:

Oxygen Meter User Manual Monday, July 23, 2007 1. Outline...2 2. Program...3 2.1. Environment for program execution...3 2.2. Installation...3 2.3. Un installation...3 2.4. USB driver installation...3 2.5. Text-to-Speech Engine...3 3. Operation...4 3.1. Preparation...4 3.2. Execution...4 3.3. Main window...5 3.4. Zero_Point calibration...7 3.5. Gas calibration...8 3.6. Liq Calibration...9 3.6.1. Liq calibration at the temperature measurement enabled...9 3.6.2. Liq calibration at the temperature measurement disabled...10 3.7. Gas Start... 11 3.8. Liq Start...13 3.9. Data transfer to Excel etc...14 3.10. Changing language...14 4. Restrictions...15 5. Notes for Operation...15 References...16 Appendix-1 DC Voltage Measurement Circuit...17 1/19

1. Outline This is an educational oxygen meter to understand oxygen concentration in gas or liquid. This measures oxygen concentration and temperature, and then displays them in a graph. Following shows the measurement system. The oxygen sensor is a Galvanic battery type sensor. This sensor generates a DC voltage proportional to the oxygen concentration. The temperature sensor is LM35DZ transistor type sensor from the National Semiconductor. This generates a DC voltage proportional to the temperature. The DC voltage measurement circuit amplifies the DC voltages from the both sensors, converts to digital values, and sends them to a Personal computer via USB cable, The personal computer displays measured values and also speaks the values by a speaker.. Features of the Oxygen sensor (1) Low cost. Easy reproducible. (2) Students can easily construct this sensor by themselves (3) Electrode liquid used for sensor is safe for human. (4) Measure both gas oxygen concentration and dissolved oxygen concentration Features of the Temperature sensor (1) It is waterproofed to measure liquid temperature. (2) It is high precise by using semiconductor PN junction voltage. 2/19

Features of this measurement system (1) The DC voltage measurement circuit does not require a DC Power supply, since the DC power is supplied from the USB cable.. (2) Calibration is easy and automatic.. (3) Measured data is displayed in real time. (4) Has an Excel interface (6) Supports bi-language.. (7) Measured values can be spoken from a PC speaker. 2. Program 2.1. Environment for program execution Windows XP, WindowsVista Runtime version of Visual Basic 6.0 Microsoft Text-to-Speech Engine Speaker 2.2. Installation Following are files for installation. setup.exe setup.lst XxxTmpMeterCAB Double click the setup.exe, and follow the procedure guided by the installation program. 2.3. Un installation Uninstall the installed program from the Windows control panel. 2.4. USB driver installation The DC voltage measurement circuit requires a special USB driver. When the USB cable is attached to the PC, the PC requires the USB driver installation. The USB driver is saved in a supplied CD-ROM. Insert the CD-ROM and install the USB driver by setting the searching path to the CD-ROM. When the USB driver is not installed completely, the following message will be displayed. "Can not find USB-COM Port!" 2.5. Text-to-Speech Engine Install the Text-Speech Engine. Those engine files can be downloaded from the next url page. 3/19

Microsoft Agent download page for end-users http://www.microsoft.com/msagent/downloads/user.asp (1)SAPI 4.0 runtime support: Download the Microsoft SAPI 4.0a runtime binaries (824 KB exe) File name: Spchapi.exe (2)Text-to-speech engines: Download selected engine Lernout & Hauspie@TTS 3000 TTS engine Japanese(3MB exe) File name: lhttpsjpj.exe Downloaded files are already saved in the CD-ROM. You can install engines from those files. 3. Operation 3.1. Preparation Connect the DC Voltage measurement circuit to the PC using the USB cable. 3.2. Execution Double click the program file, XxxTmpMeter.exe, or its short cut icon. Main windows will be opened. 4/19

3.3. Main window Main window when the temperature measurement is enabled. 5/19

Main window when the temperature measurement is disabled. Zero_Point calibration: Calibrates offset voltage of the DC Voltage measurement circuit for oxygen concentration measurement. Gas Calibration: Calibrates the oxygen concentration in gas. Liquid calibration: Calibrates the dissolved oxygen concentration in liquid. Setting: Enable or disable the temperature measurement function. Help: Displays version and how to use this software. Japanese: Changes language to Japanese; English: Changes language to English COM Port: Displays assigned com port. The DC Voltage measurement circuit has USB-Serial conversion circuit in which the USB driver automatically assigns a COM port for the USB channel. Excel Out: When checked, the software displays measured data in Excel after measurement completion. Voice Out: When checked, the measured value is spoken by PC speaker Sampling interval and count: sampling interval and count selections from this combo 6/19

boxes. Sensor out (mv): Sensor output voltage from the DC Voltage measurement circuit. Oxygen(%): Oxygen concentration. This is converted value from the above sensor out voltage. Temp( C): Temperature. This is converted value from the temperature sensor our voltage. Lower text boxes: Displays sampling interval, sampled count, measured oxygen concentration and temperature. Graphic window: Displays graphically the measured oxygen concentration and temperature. Gas start: Starts oxygen concentration measurement in gas. Liq start: Starts dissolved oxygen concentration measurement in liquid. Stop: Stops measurement. Exit: Exits from this program. Copy: Copies the measured data to a Window clip board. Excel: Displays the measured data in Excel. File: Files the measured data into a file. 3.4. Zero_Point calibration This calibrates offset voltage from Oxygen sensor. When the Zero_Point calibration menu is clicked, the following window will be opened. Short input terminals from oxygen sensor, and click the start button. Sensor output voltage is measured 10 times and average value is saves as an offset calibration voltage. 7/19

Hereafter sensor output voltage will be compensated by this value. This calibration is required only one time after when DC voltage measurement circuit is connected to the PC. 3.5. Gas calibration Sensor out voltage from pure atmosphere of gas concentration 20.9% is used for gas oxygen concentration calibration. When the Gas calibration menu is clicked, the following window will be opened. Set oxygen sensor in pure atmosphere, click the start button. Sensor output voltage is measured 10 times and average value is automatically saves as a gas calibration voltage. 8/19

3.6. Liq Calibration Saturated dissolved oxygen concentration in pure water depends on water temperature. The relation between the saturated dissolved oxygen concentration and the temperature is measured and booked. The temperature and the sensor out voltage from oxygen saturated dissolved pure water are used for dissolved oxygen concentration calibration. 3.6.1. Liq calibration at the temperature measurement enabled Both the temperature and the oxygen concentration are measured at the same time. When the Liq calibration menu is clicked, the following window will be opened. 9/19

Set oxygen sensor and temperature sensor in pure water, click the start button. Oxygen sensor output voltage and temperature are measured 10 times and average values are calculated. The temperature and the saturated oxygen sensor out voltage for the temperature are automatically saved as dissolved oxygen calibration values. 3.6.2. Liq calibration at the temperature measurement disabled The temperature is measured by another sensor. When the Liq calibration menu is clicked, the following window will be opened. Key in the temperature value and set oxygen sensor in pure water, click the start button. Oxygen sensor output voltage is measured 10 times and average values are calculated. The temperature and the saturated oxygen sensor out voltage for the 10/19

temperature are automatically saved as dissolved oxygen calibration values. 3.7. Gas Start This starts gas oxygen concentration measurement. Select sampling interval and count, and click the Gas start button. Lower text boxes display measured gas oxygen concentration and temperature. Lower picture window displays the measured data graphically. When Excel out flag is checked, the measured data is displayed by Excel after measurement completion. 11/19

12/19

3.8. Liq Start This starts dissolved oxygen concentration measurement. Select sampling interval and count, and click the Liq start button When the measurement is for dissolved oxygen, the back ground colors of data are blue. Lower text boxes display measured dissolved oxygen concentration and temperature. Lower picture window displays the measured data graphically. When Excel out flag is checked, the measured data is displayed by Excel after measurement completion. 13/19

3.9. Data transfer to Excel etc Lower text boxes display measured oxygen concentration and temperature. Excel button displays the measured data in Excel. Copy button copies the measured data into Window clip board. The clip board data can be pasted in Excel. File button files the measured data in a file. 3.10. Changing language Clicking Japanese menu changes language to Japanese. Clicking English menu changes language to English. 14/19

4. Restrictions (1) One PC can use only this one oxygen meter. (2) When Excel is used, Excel license from Microsoft is required. (3) Temperature sensor is LM35DZ from the National Semiconductor. This works from 0 C to 50 C. (4) In this version, the Text-to-Speech engine can not work for English language. 5. Notes for Operation (1) Temperature sensor is water resistant. Use the temperature sensor at the temperature range from -10 C to 60 C.. Usage outside this range will damage the sensor. (2) When you insert or remove the USB cable, handle the USB cable at fixing the USB connector. (3) To work with Text-to-Speech function, the software must be installed completely and a speaker must be attached to the PC. (4) To follow the Text-to-Speech function, the sampling time must be greater than 3 seconds.. 15/19

. References [1] Mitsuo Takahashi Trail and Experiment of Oxygen sensor, Transistor Gijytsu ( Japanese), 12, 2003 16/19

Appendix-1 DC Voltage Measurement Circuit 17/19

Hereafter shows adjustments and cable connections. Most adjustments have been executed before shipment. Usually adjustments are not needed for users. Terminal Block TB1 This has three terminals. This connects temperature sensor. TB1-1: VCC (Red wire) TB1-2: Temperature sensor out (White wire) TB1-3:: GND (Black wire) Terminal Block TB2 This has two terminals. This connects oxygen sensor. TB2-1: Oxygen sensor out (Red wire) TB2-2: GND (Black wire) Jumper J1 This selects temperature sensors. Jumper between J1-1 and J1-2: Internal temperature sensor. (Note: Now internal temperature sensor is not implemented.) Jumper between J1-2 and J1-3: External temperature sensor. Jumper J2 This selects mode of oxygen sensor out. Jumper between J1-1 and J1-2: Oxygen sensor out is current. Jumper between J1-2 and J1-3: Oxygen sensor out is voltage.. Jumper J3 & J4 This selects sensor types Jumper J3: Oxygen sensor Jumper J4: Other sensor. Variable resister VR1 This adjusts amplifier gain of temperature sensor out voltage so that the gain is 10.00. This gain is already adjusted at shipment. <How to adjust VR1> Connect the temperature sensor, measure the voltage [V] between JB1-2 and JB1-3, and adjust VR1 such that the temperature display is 100 times the measured voltage. 18/19

e.g..when the voltage [V] between JB1-2 and JB1-3 is 0.25 [V]. adjust VR1 such that the temperature is 25 C. Variable resister VR2 This adjusts amplifier gain of sensor out voltage. For the oxygen sensor, this gain is already adjusted at shipment. 19/19