The Oxygen Sensor can be connected to all types of einstein Tablets, einstein LabMate, and einstein LabMate +.

Similar documents
Oxygen Sensor with Electrode

Measuring wind speed and direction

Pressure Sensor 150 to 1150 mbar Product Number: ENPRS015

Flow Rate Sensor Product Number: ENFLO-A254A

PRODUCT SHEET. Order probe only as RXPROBE02

DISSOLVED OXYGEN SENSOR BT34i

NEULOG OXYGEN LOGGER SENSOR GUIDE

Dissolved Oxygen/Temp Waterproof Tester

Bante820 Portable Dissolved Oxygen Meter Instruction Manual

DOscan10 Pocket Dissolved Oxygen Tester Instruction Manual

Introduction The Smart Q Oxygen Adaptor enables an Oxygen electrode to be connected to an EasySense unit.

Bante810 Benchtop Dissolved Oxygen Meter Instruction Manual

Vinmetrica Dissolved Oxygen System User Manual

Experiment C-6 Gas Solubility

Aerobic Respiration. Evaluation copy

LogIT Dissolved Oxygen Probe

Bante821 Portable Dissolved Oxygen Meter Instruction Manual

STEAM STERILIZABLE POLAROGRAPHIC OXYGEN ELECTRODE

SS32L Dissolved O 2 Probe

Evaluation copy. Interdependence of Plants and Animals. computer OBJECTIVES MATERIALS

A180 DO/BOD/OUR/SOUR Meter Instruction Manual

ISE-730 Oxygen Electrode and DO2-100 Currentto-Voltage

Instruction Manual HI Portable Waterproof Dissolved Oxygen Meter.

Dissolved Oxygen Probe (Order Code DO-BTA)

Dissolved Oxygen in Water. Evaluation copy. Table 1. Temperature Range ( C) Trout Smallmouth bass Caddisfly larvae

BI-680 Online Dissolved Oxygen Controller Instruction Manual

Dissolved Oxygen Probe (Order Code DO-BTA)

Instruction Manual HI Portable Dissolved Oxygen Meter. DO meter HI 8043 STB C OFF O 2 ZERO SLOPE C. ins rum n s

STERILIZABLE DISSOLVED OXYGEN SENSORS

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

INSTRUCTION MANUAL. 840 Transmitter. Loop Powered Dissolved Oxygen Transmitter

Dissolved Oxygen Meter. ino2. Instruction Manual. Serial No..

OPERATION MANUAL DIVE CALIPER NOT SCALE / IF IN DOUBT ASK* *ALL UNITS IN MM/DEGREES UNLESS SPECIF. Dive Caliper General DC-051

Bante904 Benchtop Conductivity/Dissolved Oxygen Meter Instruction Manual

Optical Dissolved Oxygen Meter

Heavy Duty Dissolved Oxygen Meter

QUICK START GUIDE TO DRINKING WATER MONITORING

OxyProbe II Instruction Manual

Instruction Sheet. Important Note: Information that requires special emphasis. Note: Information that supplements points in the main text.

12mm Dissolved Oxygen Sensor Care and Use Instructions

Instruction Manual DO 6. Economy Hand-held Dissolved Oxygen Meter. 68X Rev 2 Apr 08. Technology Made Easy... Part of Thermo Fisher Scientific

Optical Dissolved Oxygen Meter

Dissolved Oxygen Sensor

D-OptoLogger Dissolved Oxygen Logger Operation Manual

Vernier Optical DO Probe (Order Code ODO-BTA)

Experiments in Biology

Operating manual. TA 197 Oxi. Dissolved Oxygen Depth Armature

HI 9143, HI 9143M HI 9145

D-Opto Dissolved Oxygen Sensor Operation Manual for the D-Opto 4-20mA

OxyScan Graphic. Operating Instructions. UMS Micro-oxygen sensor 501. Microprocessor instrument

Instructions for Assembly, Installation, and Operation of the Gas Addition Kit Accessory with the CEM Discover Systems

Instruction Manual HI 9146 Dissolved Oxygen and Temperature Meter

Read this first. Zetasizer nano series Self installation and Quick start guide MRK825-02

Experiment B-3 Respiration

Refillable ORP/Redox Probe: Model MTC30101 or MTC30103

SOLUBILITY OF A SOLID IN WATER

HI 2314 HI 2315 HI 23151

Instruction Manual. DO 700 Dissolved Oxygen/ºC/ºF Bench Meter. Technology Made Easy...

SOLUBILITY OF A SOLID IN WATER

EC214 EC215 - EC215R Bench Conductivity Meters

TQC Bresle Chloride test 2008

Dextens Thermo Conductivity Sensors. Type 52101, 54101, 55101

YSI-85_maint-cal Lab Version Page 1 of 13

STANDARD OPERATING PROCEDURE MAINTENANCE/CALIBRATION CHECKS OF DISSOLVED OXYGEN PROBES

Water Quality Monitoring Using a Handheld Sonde for in situ Measurements Date Prepared: 11/17/2017

1. Photosynthesis and Light. See real-time evidence that light causes photosynthesis to occur!

MARTINI. instruments. THANK YOU FOR CHOOSING. Sales and Technical Service Contacts:

Oxymax W COS41. Technical Information. Potentiostatic amperometric two-electrode sensor Long-term stable sensor for water and wastewater applications

Visit us at Code

Pool and Spa. Water Testing

Instruction Manual. Multiparameter Benchtop Meter

Biology Unit 2, Structure of Life, Lab Activity 2-3

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP

Instruction Manual DO 6+ Dissolved Oxygen/Temp

Gas Pressure Probe. Information Sheet. Total Dissolved Gas

DO_maint-cal Page 1 of 13

BIL 151 Laboratory Enzymes: Practicing the Protocol

Dissolved Oxygen and measurement possibilities. Berno Lüpkes, 15 th March 2017

Three Lakes Association Hydrolab for Dummies. Table of Contents:

Measuring the Conductivity of Pure Water Using USP<645>

CCS240 and CCS241. Technical Information. Sensors for chlorine dioxide Amperometric, membrane-covered sensors for installation in the CCA250 assembly

Aqua-DP. Aqua-DP Waterproof Dissolved Oxygen - ph -mv Temperature Meter. TPS Australia - Quality hand-made instruments since 1968.

SPECIFICATIONS APCEPH1

What is photosynthesis? Photosynthesis II: Dissolved O2

D-Opto. Dissolved Oxygen Sensor. Operation Manual (Software Version 1.0)

Calibration and Maintenance Procedures: YSI ProDSS rev 8/31/15

D-Opto Dissolved Oxygen Sensor Operation Manual

Using the Akta Prime plus October 22, 2012

YSI Model 550a Dissolved Oxygen (DO) Meter

Oxygen Measurement Systems High Reliability and Wide Application Coverage

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter

INSTRUCTIONS warranty watch care

Portable Gas Monitor GX User Maintenance Manual (H4-0050)

& Dissolved Oxygen Sensor. Instruction Manual

CCPaSEC. Procedure for the Quality Control Yearly Equipment Check. July 2018 CCPaSEC Quality Control Team

PCS 340 Core Saturator : 115 Volt : 230 Volt. Instruction Manual

Micro600DO_ZI INST /1/17 13:16 Page 1. Palintest. Micro 600 DO Meter. Palintest ZI INST 1240

COM280. Technical Information. Oxygen measurement Battery-driven pocket meter for dissolved oxygen measurement

Radnoti Liver Perfusion System

User Manual DOCUMENT # Pro20 Pro20i USER MANUAL. English

Transcription:

The Oxygen sensor is a maintenance- free galvanic oxygen electrode capable of measuring Oxygen in solutions. With built-in temperature compensation, this sensor provides an easy way for students to receive accurate results without having to preform complicated compensation calculations. The Oxygen sensor can be used to perform a wide variety of experiments taking place in a number of different environments such as measuring the amount of oxygen in an aquarium or understanding the effects of germination on oxygen levels. The Oxygen Sensor can be connected to all types of einstein Tablets, einstein LabMate, and einstein LabMate +. Monitoring changes in oxygen levels during photosynthesis and respiration of plants Consumption of oxygen by yeast during the respiration of sugars Fermentation of yogurt

Monitoring dissolved oxygen concentrations resulting from photosynthesis and respiration in an aquarium containing plants and/or fish. Monitoring the pattern between light and dissolved oxygen levels, in an aquarium with pondweed On-site testing in streams and ponds to evaluate the water s capability to support plant and animal life Oxidation of metals Range: 0 to 14 mg/l DO Accuracy: ± 2% over entire range (After calibration) Temperature Compensation: Yes Temperature Compensation range: 0 to 40 C Response Time for 95% of Reading: Up to 2 minutes Note: sensor cables sold separately Before use, let the sensor adjust to the surrounding temp for several minutes. Before use, remove the protective cap and use the dropper to fill it with Galvanic O 2 Fill solution. Make sure it contains no air bubbles. This procedure is necessary only if you have had to replace the electrode membrane or the Galvanic O 2 fill solution. It is important to stir the solution during measurement as oxygen consumption by the probe can momentarily reduce the oxygen concentration at the probe surface. Do not allow any air bubbles to be trapped on the membrane surface, as it will read an air bubble as an oxygen saturated sample. The DO electrode membrane is very sturdy, relative to other electrodes. Its function is more of a physical barrier (permeable to O 2 ) rather than a chemical reaction type membrane. In pond water, its useful life is determined by how well it is cared for e.g. avoiding stretching, scratching, and fouling the membrane. The membrane s only problem areas are: o Scratches or tears - Scratches could change the accuracy of the probe, tears will cause immediate failure o Fouling of the membrane impacts measurement only if it impedes the membranes permeability to DO. This is unlikely in pond water whereas in wastewater this may be a common problem. o Fouling of the Galvanic O 2 Fill solution impacts measurement. If needed, replace the solution or the solution together with the membrane. o Stretching of the membrane impacts measurement as the thickness of the membrane and position of the membrane on the cathode are critical parameters of the measurement.

After the electrode has been used for a period of time the following cleaning method is recommended: 1. Carefully unscrew the cap from the body. 2. Rinse the inside of the membrane cartridge with DI water. 3. Soak the lead anode in 0.1N HCL (8.3 ml concentrated HCl in 1000 ml DI water) for 15 to 20 minutes. Rinse the lead anode with DI water, blot dry with tissue paper. Screw the lead anode back onto the body. 4. Rinse the soaked portions thoroughly with DI water. Blot dry with tissue paper. 5. Fill the cap with electrolyte to a level just above the membrane cartridge using the dropper provided with the sensor. Hold the electrode in an upright position and gently screw the cap back onto the body. 6. Inspect the membrane for tears or leakage. The membrane should be uniformly stretched across the inner body. Replace the membrane if any damage has occurred. Membrane Replacement 1. The membrane should be examined routinely after each fermentation cycle and replaced if any deterioration is evident. See the illustration below. 2. Carefully unscrew the cap from the body. 3. Using the membrane tool provided, pop the membrane cartridge from the cap. 4. Inspect the platinum cathode. Gently wipe it with tissue paper and see if there are any cracks or damage. 5. Take a new membrane out of the plastic package and insert into the cap. Push it down inside until firmly seated inside the outer cap using the membrane tool provided. 6. Fill the cap with electrolyte to a level just above the membrane cartridge, using the dropper provided with the sensor. 7. Do not allow any air bubbles to be trapped on the membrane surface, as it will read an air bubble as an oxygen saturated sample 8. Hold the electrode in an upright position and gently screw the cap back onto the body. Inspect the membrane for tears or leakage. The membrane should be uniformly stretched across the inner body.

In the Current Reading column, click Set cancels this action to set the current value as the zero or base value. Reset Under Current Reading column flip the Set As Zero switch to set the current value as the zero or base value. Two Point Calibration 1. Go to the Full Setup window and in the Calibrate column click Set 2. The Calibration window will appear 3. Saturate water with Oxygen by vigorously stirring the water. Enter the known value for saturated water according to your location in the Point 1, Real Reading field (go to http://water.usgs.gov/software/dotables/ for help in determining saturation levels for your location) 4. Measure the solution and, wait for the readings to stabilize. Enter the measurement as the Point 1 Measured Reading field and click the lock button 5. Prepare a second solution with a known value (we recommend using sodium sulfite or Na 2 SO 3 for zero solution in order to reduce the DO of water to zero). Enter this known value in the Point 2, Real Reading field 6. Measure the solution and, wait for the readings to stabilize. Enter the measured value as the Real Reading on the first line and click the lock button 7. Click Calibrate Note: Graphics in your version of MiLAB may differ

Two Point Calibration 1. Tap the Settings button next to the sensor s name 2. Tap Manual Calibration 3. Saturate water with Oxygen by vigorously stirring the water. Enter the known value for saturated water according to your location in the Point 1, Real Reading field (go to http://water.usgs.gov/software/dotables/ for help in determining saturation levels for your location) 4. Measure the substance and, wait for the readings to stabilize. Enter the value as the Point 1 Measured Reading field and click the lock button 5. Prepare a second solution with a known value (we recommend using sodium sulfite or Na 2 SO 3 for zero solution in order to reduce the DO of water to zero). Enter this known value in the Point 2, Real Reading field 6. Measure the solution and, wait for the readings to stabilize. Enter the known value as the Real Reading on the first line and click the lock button 7. Click Calibrate 1. Take your einstein Tablet OR pair your einstein LabMate with your Android or ios tablet via Bluetooth 2. Insert the sensor cable into one of the sensor ports 3. Launch MiLAB 4. MiLAB will automatically detect the sensor and show it in the Launcher View 5. Check the icon next to the sensor ( ) to enable it for logging 1. Pair your einstein LabMate with your PC, MAC, or Linux machine via Bluetooth, or connect it via the USB cable (found in the einstein LabMate box). 2. Insert the sensor cable into one of the sensor ports 3. Launch MiLAB 4. MiLAB will automatically detect the sensor and show it in the Current Setup Summary window

5. Click Full Setup, located at the bottom of the Current Setup Summary window to program the data logger s sample rate, number of samples, units of measurement, and other options. 6. Click the Run button ( )on the main toolbar of the Launcher View to start logging The Oxygen Sensor comes with: One Oxygen sensor One electrode One bottle Galvanic O 2 Fill Solution One bottle Salt for zero solution One plastic dropper Extra membranes 1. Fill a beaker with water. 2. Insert the electrode into the water and calibrate. 3. Click the Run button ( ) to start logging. 4. Use a stirrer or a simple spoon to increase the oxygen concentration. 5. See expected results on figure-1.

figure-1 If the Oxygen sensor isn't automatically recognized by MiLAB, please contact Fourier Education's technical support. For technical support, you can contact the Fourier Education's technical support team at: Web: www.einsteinworld.com/support Email: support@fourieredu.com Phone (in the US): (877) 266-4066 All standard Fourier Systems sensors carry a one (1) year warranty, which states that for a period of twelve months after the date of delivery to you, it will be substantially free from significant defects in materials and workmanship. This warranty does not cover breakage of the product caused by misuse or abuse. This warranty does not cover Fourier Systems consumables such as electrodes, batteries, EKG stickers, cuvettes and storage solutions or buffers.