D05 Pressure Regulating Valves

Similar documents
D05T Compact Design Pressure Regulating Valves

DS05C,D,G Dial Set Pressure Regulating Valves

DS06D,G Dial Set Pressure Regulating Valve

V43 Pressure Actuated Water Regulating Valve

TECHNICAL DATA. Pressure Regulation 531a. April 24, 2009

TECHNICAL DATA. Page 1 of 12

Bermad Pressure Reducing. Model: 42T

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012

TECHNICAL DATA CAUTION

Model: 720-UL INSTALLATION OPERATION MAINTENANCE. Bermad Pressure Reducing Valve IOM. Model: FP -720-UL Sizes: 2"-12" BERMAD. Application Engineering

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

Operation & Maintenance Manual Place this manual with valve or person responsible for maintenance of the valve

TECHNICAL DATA CAUTION

MEGR-1627 Instruction Manual

Type S301 & S302 Gas Regulators INTRODUCTION INSTALLATION. Scope of Manual. Description. Specifications. Type S301 and S302. Instruction Manual

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

Product Manual. Description. Specifications. CVS Type 1301F and CVS Type 1301G Regulator. Introduction

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

Installation Instructions

Anderson Greenwood Series 93 Positive Pressure POSRV Installation and Maintenance Instructions

Water Pressure Reducing Valves

553 Series.

Model GP PRESSURE REDUCING VALVE Installation & Operation Manual

RELIABLE PROTECTION FOR A WIDE RANGE OF RESIDENTIAL, COMMERCIAL AND INDUSTRIAL APPLICATIONS. water pressure reducing valves

Scald Protection Three-Way Thermostatic Mixing Valve

Model: 43T. Bermad Pressure Relief Valve

Pressure Regulator B-95

V48 Series 3-Way Pressure-Actuated Water-Regulating Valves With Union Fittings

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

RD(H)20/25 Pressure-Reducing Regulator User Manual

Cash Valve TYPE G-4 PILOT OPERATED PRESSURE REDUCING REGULATOR FOR STEAM, AIR AND GASES. ISSUED - MARCH 2001 CAVMC-0512-US-0208 ISO 9001 Certified

C645A-E Pressure Switches

TECHNICAL INSTRUCTIONS

Scald Protection 3-Way Thermostatic Mixing Valve

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.

Cash Valve. Type G-4. Pilot Operated Pressure Reducing Regulator for Steam, Air and Gases. Flow Control

Model 420-HY Pressure Regulating Hydrant Valve

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

Principles of Pressure Regulation. Zurn Wilkins Pressure Reducing Valves

Operating Instructions Model and Hydrostatic Test Pump

Installation Operation Maintenance. Bermad Level Control Valve with Modulating Horizontal Float Pilot valve One Way Flow IOM.

V46 Series 2-Way Pressure-Actuated Water-Regulating Valves With Union Fittings

Operation Manual Piston Sensed Gas Pressure Regulators

Eaton Filtration, LLC

I T T Pressure Reducing Valve WARNING INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

MEGR-1912 Instruction Manual

Eaton Filtration, LLC

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

Speed control assembly model A-1

WATER PRESSURE REDUCING VALVES

Anti-flood device Model B-1

LRS(H)4 Pressure-Reducing Regulator User Manual

WW-730. Pressure Sustaining/Relief Control Valve

Operator: Save these instructions for future use!

1805 Series Relief Valves

V146 Series 2-Way Pressure-Actuated Water-Regulating Valves

Types PT and ETP Dome-Loaded Pressure Regulator Valves

Installation, Operation, and Maintenance Manual

1200B2 Series Service Regulators. Instruction Manual

WW-720. Pressure Reducing Control Valve

WW-720. Pressure Reducing Control Valve

Pre-adjustable pressure reducing valves

2.0 INSTALLATION & SERVICE

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

Types 749B and R130 Changeover Manifolds

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES

1800C and 1800C-HC Series Service Regulators

Aquor House Hydrant V2

Type ACE97. Introduction. Installation. P.E.D. Categories. Specifications. Overpressure Protection. Installation Guide English May 2002

Model GPR Primary Pressure Regulating Valve. Instruction Manual

Models: C62/63/64-A/D

SPECIFICATIONS FRS. 2 1/2 DN (ISO) Flanged. FRS DN (ISO) Flanged

Needle valve. Contents. User s Manual. (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2

WaterSource Heat Pump Hose Kit Performance Specification-Summary

START UP MANUAL MADE IN USA REV US and Foreign patents and patents pending see

Installation Troubleshooting Maintenance Instructions Installation / Start-up

RS(H)20, 25 USER MANUAL

G92 Series BASOTROL Automatic Pilot Gas Valve

THE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv)

Operating Instructions Model and Hydrostatic Test Pump

Filling valves AL, ALM Series Automatic filling units ALOMDIW, ALOMDNW Series

Avenger Model 33M Installation & Operation Instructions

INSTALLATION INSTRUCTIONS

Pressure Dump Valve Service Kit for Series 3000 Units

Commonwealth of Massachusetts Approved Product Approval code G

SUBMITTAL NOTES PROJECT: Ross Model 50RWR-A Pilot Operated Surge Relief Valve with Hydraulic Anticipation. Size: inch / mm

Pressure Dump Valve Service Kit for Series 2300 Units

VB-7213 Series. Application. Features. Applicable Literature. 1/2" to 2" Screwed NPT Stem Up Open, Two-Way Valves General Instructions

Operating Instructions Models and Hydrostatic Test Pumps

SINGER MODEL 106/206-RPS-L&H

Pressure Independent Control Series

Installation Instructions

WHEATLEY WHEATLEY SERIES 500 SWING CHECK VALVE. Installation, Operation and Maintenance Manual

TECHNICAL DATA ANTI-FLOOD DEVICE MODEL B-1 1. DESCRIPTION

BERMAD Waterworks. Level Control Valve with Altitude Pilot. 700 Series. Model X. Features and Benefits. Major Additional Features

1301 Series High-Pressure Regulators

Rate of Flow Valve Series 120

VB-7211 Series. Application. Features. Applicable Literature. 1/2" to 1-1/4" Union End NPT Stem Up Open, Two-Way Valves General Instructions

Bermad Model:

AUTOMATIC PRESSURE REDUCTION THE VALUE OF ECONOMIZING SOLVING OVERPRESSURE PROBLEMS LEADERSHIP IN ENERGY AND ENVIRONMENTAL DESIGN (LEED)

Transcription:

D05 Pressure Regulating Valves FEATURES PRODUCT DATA Noncorroding unitized cartridge contains all working parts and is easily replaceable. Includes built-in strainer and thermal bypass. Balanced seat construction provides superior pressure regulation. Inlet and outlet are internally threaded female NPT, and externally threaded for use with union assemblies. One model can be used in low, standard or high pressure applications; D05 has a 5 to 50 psi outlet pressure adjustment range with up to 400 psi inlet pressure. Available with or without gauge tap. APPLICATION U06P Stand-In Pipe available for temporary installation during construction or system flushing. Two-year warranty. The Honeywell Braukmann D05 Pressure Regulating Valve is a high quality pressure regulating valve that maintains a constant outlet pressure over a wide range of inlet supply pressures. It is ideally suited for new residential and light commercial construction, drip irrigation, and applications requiring highly sensitive and accurate regulation. The wide inlet pressure range of the D05 gives flexibility without compromising reduced outlet pressure accuracy or capacity. The superior balanced single-seat design maintains a constant outlet pressure over a wide range of inlet pressures. The noncorroding unitized cartridge insert contains all the working parts and is easily replaceable. The D05 is used for water or air regulation. It is not suitable for steam. CONTENTS Application... Features... Specifications... 2 Ordering Information... 2 Installation... 3 Operation... 7 Troubleshooting... 7 D05 Parts and Accessories... 8 Copyright 996 Honeywell Inc. All Rights Reserved 62-302-2

SPECIFICATIONS Model: D05 Pressure Regulating Valves Construction Materials: Body: Bronze. Internal Parts: Stainless steel and engineered thermoplastic. Regulator Mechanism: Fabric-reinforced diaphragm. Inlet Pressure: 400 psi maximum. Reduced Pressure Range: 5 to 50 psi (/2 in. to in.). 5 to 30 psi (-/4 in.). Outlet Pressure: Factory set at 60 psi. Differential: 4 psi minimum (inlet to outlet). Temperature (Maximum): Air: 58 F (70 C). Water: 80 F (82 C). Pipe Sizes: /2 in., 3/4 in., in., and -/4 in. available. Connections: Can be configured as female thread-by-thread, single- or double-union, NPT threaded or sweat. Strainer Screen Size: 0.032 in. Gauge Tap: /4 in. NPT (available on all models). Approvals: ASSE (Std. 003) Certified. IAPMO, CSA, and City of L.A. Listed. Dimensions: See Fig.. Reduced Ratio: 0: maximum. SIZE 4 (INCHES) H h l /2 4-9/6 (6) 2-/6 (52) 3-3/6 (8) 3/4 4-9/6 (6) 2-/6 (52) 3-/2 (89) 6 (52) 2-5/8 (66) 3-5/6 (00) -/4 6 (52) 2-5/8 (66) 4-/6 (9) H SWEAT TAILPIECE THREADED TAILPIECE SIZE (INCHES) 2 3 L 2 L' L L' 3 /2 3/4 3-7/8 (98) 4-5/6 (0) 4-5/8 5-3/6 (8) (32) 4-/6 4-5/6 (03) (0) 4-5/6 (26) 5-3/6 (32) h 5-/4 (33) 6-/2 (66) 5 (27) 6-/6 (54) -/4 6-3/6 (57) 7-/6 (95) 6 (52) 7-5/6 (85) NON-UNION MODEL. 2 SINGLE-UNION MODEL. 3 DOUBLE-UNION MODEL. 4 DIMENSIONS WITH GAUGE PLUG. L 2 l L' 3 M764B ORDERING INFORMATION Fig.. D05 installation dimensions in in. (mm). When purchasing replacement and modernization products from your manufacturing representative, specify the complete model number. If you have additional questions, need further information, or would like to comment on our products or services, please contact: Honeywell Sparco/Braukmann Customer Service 65 Access Road Warwick, Rhode Island 02886 www.honeywell.ca/braukmann/ www.sparco-inc.com In Canada Contact your nearest Honeywell Home and Building Control Sales Office. 62-302 2 2

Water Capacities (See Table ) The suitability of a given regulator size is dependent on the pressure requirements of each installation. To determine the pressure regulator valve size required for a specific installation, determine the following:. Pressure differential between inlet and outlet pressure in pounds per square inch (psi), 2. Capacity in gallons per minute (gpm), and 3. Allowable reduced pressure falloff in psi. Given these variables, use Table to determine the proper size pressure regulator valve for your application. Example: An installation has 35 psi inlet pressure, 60 psi outlet pressure (75 psi pressure differential). If 2 gpm capacity is required with only 0 psi falloff allowable, a /2 in. D05 is required. Table. Water Capacities. Pressure Differential Between Inlet and Outlet Pressure Reduced 25 psi 50 psi 75 psi 00 psi or more Regulator Pressure Flow Flow Flow Flow Valve Falloff Capacity Velocity Capacity Velocity Capacity Velocity Capacity Velocity Size (psi) (US gpm) (ft/sec) a (US gpm) (ft/sec) a (US gpm) (ft/sec) a (US gpm) (ft/sec) a /2 inch 6 7.0 7.3 8.0 8.3 9.0 9.4 0.0 0.4 0 0.0 0.4.0.5 2.0 2.5 3.0 3.5 5 3.0 3.5 5.0 5.6 6.0 6.7 7.0 7.7 20 5.5 6.0 8.0 9.5 9.0 2.0 20.0 22.0 3/4 inch 6 9.0 5.4 0.0 6.0.0 6.5 2.0 7. 0 5.0 8.9 6.0 9.5 7.0 0.0 8.0 0.7 5 20.0.9 22.0 3.7 23.0 3.7 24.0 4.3 20 23.0 3.9 26.0 7.6 27.0 6.7 28.0 7.3 inch 6.5 4.2 3.0 4.7 4.5 5.3 6.0 5.8 0 20.0 7.2 2.5 7.8 23.0 8.3 24.5 8.9 5 28.0 0.7 30.0 0.9 33.0 2.0 35.0 2.7 20 32.0 4.0 37.0 3.5 40.0 5.5 4.0 5.0 -/4 inch 6 3.5 2.9 6.0 3.4 20.0 4.3 22.0 4.7 0 22.0 4.7 29.0 6.2 34.0 7.3 38.0 8. 5 37.0 7.9 56.0 2.0 62.5 3.4 73.0 5.6 20 55.0.8 78.0 6.7 87.0 8.6 0.0 2.6 a Velocity in feet per second is based on schedule 40 pipe size. recommended pressure falloff for general use is approximately 04 kpa (5 psi). Recommended velocities for the flow of water: Residential and general use, 5 to 0 feet per second; industrial use, 7 to 5 feet per second; boiler feed, 7 to 5 feet per second. INSTALLATION When Installing this Product... Read these instructions carefully. Failure to follow them could damage the product or cause a hazardous condition. Check the ratings given in these instructions and on the product to make sure the product is suitable for your application. Installer must be a trained, experienced service technician. After installation is complete, check out the product operation as provided in these instructions. Procedure Flush the system clear of sediment or debris. Close the supply valve and downstream isolating valve (if used). Install the D05 with the arrow on the body pointing in the direction of water flow. (The D05 can be mounted in any position.) The D05 can be installed directly onto the pipe by using the female NPT threads on each end. If space limitations restrict turning the D05, install single- or double-unions. NOTE: Heat from soldering can damage internal parts of the D05. Always remove the tailpiece(s) from the D05 during soldering, or disassemble the D05 prior to heating the casting. Open the supply valve. Changing the Outlet Pressure (See Fig. 2) The D05 is factory set to 60 psi. To change the outlet pressure, turn the adjusting bolt counterclockwise to reduce pressure or clockwise to increase pressure. To adjust the outlet pressure to a desired setting: Close the supply shutoff valve and open a downstream faucet to relieve static pressure in the line. Install a pressure gauge to the gauge tap on D05G models, or temporarily with a downstream hose bib on other D05 models. 3 62-302 2

600 800 D05 PRESSURE REGULATING VALVES Loosen the locknut by turning counterclockwise two turns. Turn the adjusting bolt counterclockwise several turns to make sure the setting is below the desired setting. Close all downstream valves and/or faucets and slowly open the supply valve until fully open. Turn the adjusting bolt clockwise to gradually increase the pressure until the gauge indicates the desired outlet pressure (under no flow condition). Reopen a downstream valve. During flow, there will normally be a pressure falloff of 3 to 5 psi depending on the amount of water flow. Tighten the locknut by turning clockwise until tight. Do not overtighten. Replacing the Cartridge (See Fig. 3) The working parts of the D05, including diaphragm, valve seat, and disk are all contained in a replaceable cartridge. To replace the cartridge: Shut off the supply valve and open a downstream faucet to relieve the system pressure. CAUTION To prevent injury and/or equipment damage, loosen locknut and turn adjusting screw counterclockwise to remove spring tension. Loosen locknut and turn adjusting screw counterclockwise to remove spring tension. Remove the bonnet and washer using an adjustable wrench, socket, or box-end wrench. Remove the cartridge using two screwdrivers as levers. Attach new O-rings and screen onto the new cartridge. Make sure O-rings are properly installed above and below the screen. Insert the new cartridge. Do not scratch the sides. Place the washer on top of the cartridge. NOTE: The inner lip must be pointing up to avoid damaging the diaphragm. Replace the spring, spring cup, and bonnet. Readjust the outlet pressure to the desired setting by using the procedure described in Changing the Outlet Pressure section. 400 200 00 000 75 25 50 50 25 75 200 0 200 0 PSI kpa 400 HONEYWELL BRAUKMANN LOOSEN LOCKNUT BY TURNING COUNTERCLOCKWISE 2 TURN ADJUSTING BOLT COUNTERCLOCKWISE TO DECREASE OR CLOCKWISE TO INCREASE OUTLET PRESSURE 3 TIGHTEN LOCKNUT BY TURNING CLOCKWISE THE CLOCKWISE AND COUNTERCLOCKWISE DIRECTIONS ARE DETERMINED BY LOOKING DIRECTLY AT THE ADJUSTING BOLT 50 00 200 water test 50 250 300 PSI M762 Fig. 2. Changing outlet pressure. 62-302 2 4

LOOSEN LOCKNUT AND TURN ADJUSTING SCREW COUNTER CLOCKWISE TO REMOVE SPRING TENSION 2 REMOVE BONNET USING AN ADJUSTABLE WRENCH, SOCKET, OR BOX END WRENCH 3 REMOVE CARTRIDGE USING TWO SCREWDRIVERS AS LEVERS 4 ENSURE O-RINGS AND WASHER ARE PROPERLY INSTALLED WASHER (LIP UP) O-RINGS M76A Fig. 3. Replacing the D05 cartridge. Cleaning the Cartridge Screen To clean the cartridge screen: Shut off the supply valve and open a downstream faucet to relieve the system pressure. CAUTION To prevent injury and/or equipment damage, loosen locknut and turn adjusting screw counterclockwise to remove spring tension. Loosen locknut and turn adjusting screw counterclockwise to remove spring tension. Remove the bonnet and washer using an adjustable wrench, socket, or box-end wrench. Remove the cartridge using two screwdrivers as levers as shown in Fig. 3. Remove and clean the cartridge screen. NOTE: D05G models can be cleaned to some extent by removing the gauge tap plug and using an air hose to blow air into the unit. Replace the cartridge screen and make sure the O-rings are installed properly. Carefully clean the cartridge seat area. Insert the cartridge. Do not scratch the sides. Place the washer on top of the cartridge. NOTE: The inner lip must be pointing up to avoid damaging the diaphragm. Replace the spring, spring cup and bonnet (see Fig. 4). Readjust the outlet pressure to the desired setting by using the procedure described in Changing the Outlet Pressure section. 5 62-302 2

ADJUSTING SCREW LOCKING NUT BONNET SPRING CUP SPRING WASHER CARTRIDGE O-RING SCREEN O-RING GASKET TAILPIECE NUT NUT TAILPIECE BODY GASKET GAUGE TAP PLUG M760A Fig. 4. D05 exploded view. 62-302 2 6

OPERATION The Honeywell Braukmann D05 is a balanced, direct acting pressure regulating valve. The D05 provides constant downstream pressure regardless of varying inlet pressures and downstream flow demands. The spring force holds the valve in the open position until downstream pressure, sensed by a port, is sufficient to press on the underside of the diaphragm and close the valve. As downstream pressure drops due to demand, the force on the diaphragm is reduced and the valve opens. Adjustment is made by manually turning the adjustment screw clockwise to increase the spring force and require a higher downstream pressure to close the valve. Similarly, reducing the spring force lowers the outlet set pressure. Once the outlet pressure is set, the D05 automatically regulates to maintain the downstream pressure. See Fig. 5 for the internal construction of the D05. INLET OUTLET M763 Fig. 5. Internal construction of D05. TROUBLESHOOTING Table 2 provides a troubleshooting guide for the D05 Pressure Regulating Valves. Problem Table 2. Troubleshooting the D05 Pressure Regulating Valves. Solution Whistling noise. Slightly increase or decrease the outlet pressure until the noise disappears. Will not hold pressure. Clean the filter cartridge. Chatters. Replace the screen and O-rings. Replace the cartridge (see replacing the cartridge section). Freezes up. Replace bonnet or cartridge, if damaged. To avoid future freeze-up: Temporarily (slightly) open a downstream faucet if the DS05 is going to be exposed to temperatures below 32 F (0 C). The slight water flow will eliminate freeze-up. Move the DS05 to a location with an ambient temperature above 32 F (0 C) if it is currently exposed to prolonged temperatures below 32 F (0 C). Pressure gauge measures a lower pressure under flow conditions than was originally set during static conditions. DS05 is functioning properly. No action is necessary. The pressure decrease is characteristic of all directacting pressure regulating valves and is referred to as falloff. 7 62-302 2

D05 Parts and Accessories Order Number Description Replacement Parts 203223 Bonnet Assembly for /2 and 3/4 in. Valves. 203224 Bonnet Assembly for and -/4 in. Valves. 272840 Gasket for /2 in. D05/DS05 (quantity 24). 27284 Gasket or 3/4 in. D05/DS05 (quantity 24). 272842 Gasket for in. D05/DS05 (quantity 24). 272843 Gasket for -/4 in. D05/DS05 (quantity 24). K05A009 Replacement Cartridge, Screen and O-ring for /2 and 3/4 in. Valves. K05A07 Replacement Cartridge, Screen and O-ring for and -/4 in. Valves. K05B007 Replacement Screen and O-ring for /2 and 3/4 in. Valves. K05B05 Replacement Screen and O-ring for and -/4 in. Valves. Union Kits K06U069 K06U077 K06U085 Union Kit /2 in., includes nut, female NPT threaded tailpiece and gasket. Union Kit 3/4 in., includes nut, female NPT threaded tailpiece and gasket. Union Kit in., includes nut, female NPT threaded tailpiece and gasket. Order Number K06U35 K06U093 K06U0 K06U9 K06U43 Description Union Kit -/4 in. for D05/D505, includes nut, female NPT threaded tailpiece and gasket. Union Kit /2 in., includes nut, sweat tailpiece and gasket. Union Kit 3/4 in., includes nut, sweat tailpiece and gasket. Union Kit in., includes nut, sweat tailpiece and gasket. Union Kit -/4 in. for D05/D505, includes nut, sweat tailpiece and gasket. Accessories 202868 Filter Washer, 3/4 in., for use with U06P045 Plastic Stand-in Pipe. 202869 Filter Washer, in., for use with U06P052 Plastic Stand-in Pipe. U06P045 Plastic Stand-in Pipe (spacer) for use with D05 Double Union Pressure Regulating Valves, 3/4 in. U06P052 Plastic Stand-in Pipe (spacer) for use with D05 Double Union Pressure Regulating Valves, in. Pressure Gauges M39A032 Pressure Gauge with Bottom Inlet; 0 to 60 psi. MT94A006 Water Pressure Test and Recording Gauge with Hose Bib Connection; 0 to 300 psi. Home and Building Control Honeywell Inc. 985 Douglas Drive North Golden Valley, MN 55422 62-302 2 Rev. 2-96 Printed in U.S.A. Home and Building Control Honeywell Limited-Honeywell Limitée 55 Gordon Baker Road North York, Ontario M2H 2C9 8 Helping You Control Your World www.sparco-inc.com www.honeywell.com/braukmann/