DURON TM ADVANCED 10W-30

Similar documents
ALLISON TES-295 FLUID

Version 3.0 Revision Date 2017/02/07 Print Date 2017/02/07. Product code : KRSTL10DRX, KRSTL10, KRSTL10BLK

DURON TM/MC SHP 10W-30

PURITY TM FG SYNTHETIC EP GEAR FLUID 220

Version 2.0 Revision Date 2018/09/20 Print Date 2018/09/20. Product code : SVF19P20, SVF19DRX, SVF19, SVF19BLK

SAFETY DATA SHEET. Revision Date 2017/07/15 BASE OIL. Direct Line Sales 3325 North Service Road, Unit 104 Burlington, ON, L7N 3G

LUMINOL TM TR (Type I Trace-Inhibited)

PURITY TM 1020 BASE OIL

PURITY TM FG SYNTHETIC 46 FLUID

Version 2.0 Revision Date 2015/01/26 Print Date 2015/01/26

PURITY TM FG EP GEAR FLUID 320

Version 2.0 Revision Date 2015/04/02 Print Date 2015/04/02. Product code : PFGCL2P17, PFGCL2KGL, PFGCL2DRL, PFGCL2, PFGCL2C30

LUMINOL TM TR-i (Type II Inhibited)

Version 3.1 Revision Date 2017/02/17 Print Date 2017/02/17

DEXRON GEAR OIL 75W-90

Version 3.1 Revision Date 2017/02/10 Print Date 2017/02/10. Product code : CPXS46P20, CPXS46DRM, CPXS46DCT, CPXS46, CPXS46BLK

Version 2.0 Revision Date 2015/03/23 Print Date 2015/03/23. Product code : SVF20P20, SVF20DRX, SVF20, SVF20BLK

MO142PC SAFETY DATA SHEET Version 5.1 Revision Date 2017/02/17 SECTION 1. IDENTIFICATION

Version 6.0 Revision Date 2017/11/03 Print Date 2017/11/03

Version 1.0 Revision Date 2017/01/01 Print Date 2017/01/01. : Wainbee VNT 2000 : 3060, 3061, 3062, 3063, 3064

PRECISION TM SYNTHETIC EMB

PURITY TM FG TROLLEY FLUID 46

DURATAC TM CHAIN OIL 100

SUPREME TM SYNTHETIC BLEND 2-STROKE SMALL ENGINE OIL

PURITY TM FG SYNTHETIC EP GEAR FLUID 220

COMPRO TM/MC XL-S 100

Version 2.0 Revision Date 2018/04/12 Print Date 2018/04/12

Wainbee Food Grade Oil

Version 3.1 Revision Date 2017/02/10 Print Date 2017/02/10. Product code : CALHTFDRM, CALHTFDCT, CALHTF, CALHTFBLK

CALFLO TM/MC SYNTHETIC

TRAXON TM E SYNTHETIC 75W-90

PURITY TM FG2 WITH MICROL TM MAX

PURITY TM FG WO WHITE MINERAL OIL 15

Version 4.0 Revision Date 2016/08/05 Print Date 2017/01/13. Product code : SYND68P20, SYND68DRM, SYND68, SYND68DCT

PURITY TM FG2 WITH MICROL TM MAX

HEAVY DUTY SYNTHETIC BLEND ATF

CIVITAS WEEDfree BRAND CONCENTRATE

PURITY TM FG WO WHITE MINERAL OIL 15

SYNDURO TM/MC SHB 220

Version 2.0 Revision Date 2015/01/26 Print Date 2015/03/12. Product code : GMDEX6IBC, GMDEX6DRM, GMDEX6CQT, GMDEX6C4U, GMDEX6BLK

AC DELCO AUTO-TRAK II FLUID

Monarch Oil (Kitchener) Limited

Version 5.1 Revision Date 2017/02/17 Print Date 2017/06/13

Version 4.0 Revision Date 2017/03/09 Print Date 2017/03/13

PURITY TM FG EP GEAR FLUID 220

TRAXON TM/MC E SYNTHETIC CD-50

DEXRON GEAR OIL 75W-90

PURITY TM FG WO WHITE MINERAL OIL 15

PURITY TM FG HEAT TRANSFER FLUID

LUMINOL TM TR-i (Type II Inhibited)

Version 2.0 Revision Date 2018/08/10 Print Date 2018/08/10

Issue Date: 20-Oct-2012 Revision Date: 17-Nov-2014 Version 1 1. IDENTIFICATION. Coastal Dexron VI Automatic Transmission Fluid

HYDREX TM XV ALL SEASON

Version 5.0 Revision Date 2016/09/27 Print Date 2017/01/13

Version 2.1 Revision Date 2018/05/25 Print Date 2018/05/25. Product code : MOSP25DRM, MOSP25DCT, MOSP25C16, MOSP25, MOSP25C12

DURON TM/MC -E 10W-30

PRODURO TM/MC TO

PURITY TM FG2 EXTREME

VULTREX TM DRILL ROD HEAVY

HYDREX TM XV ALL SEASON

FSC-MAX FLUID FSC-8000 COMPRESSOR FLUID

HYDREX TM MV ARCTIC 15

: PURITY TM FG HEAT TRANSFER FLUID

AC DELCO DEXRON LS 75W-90

Version 2.1 Revision Date 2018/08/15 Print Date 2018/08/15

: PURITY TM FG HEAT TRANSFER FLUID

Version 3.0 Revision Date 2015/08/18 Print Date 2015/08/18. Product code : CALLTDCT, CALLTIBC, CALLTDRM, CALLT, CALLTBLK

Version 5.1 Revision Date 2017/02/13 Print Date 2017/06/15

DURON TM/MC UHP 5W-30

Issue Date: 20-Oct-2012 Revision Date: 17-Nov-2014 Version 1 1. IDENTIFICATION 2. HAZARDS IDENTIFICATION

CIVITAS WEEDfree BRAND TM/MC CONCENTRATE

Version 2.0 Revision Date 2014/09/26 Print Date 2014/09/26. Product code : CPXS46P20, CPXS46DRM, CPXS46DCT, CPXS46, CPXS46BLK

: PURITY TM FG HEAT TRANSFER FLUID

SAFETY DATA SHEET according to Regulation (EC) No. 1907/2006 PURITY TM FG COMPRESSOR FLUID 68

: : No hazards which require special first aid measures.

SikaTack ELITE :

SAFETY DATA SHEET according to Regulation (EC) No. 1907/2006 SUPREME TM/MC 5W-20

Sikaflex MS Patiki Road Avondale Auckland AKL 1026 :

Sikaflex -527 AT : Hazardous components Chemical Name CAS-No. Concentration (%) N-[3-

PETRO-CANADA BRAKE FLUID

: Sika BlackSeal Plus (NZ)

SikaWrap -430G. Hazardous components Chemical name CAS-No. Concentration (%) glass, oxide, chemicals >= 90 - <= 100

: Sikaflex AT-Façade SAFETY DATA SHEET. Sikaflex AT-Façade. Version 1.0 SDS Number: Revision Date: 2017/12/07

: SikaGrout Fluidifier

CIVITAS WEEDfree BRAND TM/MC CONCENTRATE

85-91 Patiki Road Avondale Auckland AKL 1026 :

: PETRO-CANADA ATF D3M

: Sika CarboDur (all types)

Sigunit -L53 AF Patiki Road Avondale Auckland AKL 1026 : : No hazards which require special first aid measures.

MATERIAL SAFETY DATA SHEET WAUKEE FLO-METER OIL

Intraplast Z :

: COMPRO TM SYNTHETIC COMPRESSOR FLUID

: : No hazards which require special first aid measures.

PURITY TM/MC FG SILICONE SPRAY

Version 1.4 Revision Date 10/19/2015 Print Date 12/01/2015. QIAGEN Str. 1 D Hilden

SAFETY DATA SHEET. Section 1. IDENTIFICATION

: SikaSet Accelerator

6800 W. 73 rd Street Bedford Park, IL Ph#: (708) Emergency Contact: Chemtrec (800)

Version 1.1 SDS Number: Revision Date: SECTION 1: Identification of the hazardous chemical and of the supplier

Recommended use of the chemical and restrictions on use Product use : Concrete and mortar admixture. :

Transcription:

DURON ADVANCED 10W-30 SECTION 1. IDENTIFICATION Product name : DURON ADVANCED 10W-30 Synonyms : FA410W30 Product code : DFA13BLK, DFA13C12, DFA13DCT, DFA13P5R, DFA13DRR, DFA13ICT, DFA13C16, DFA13P20, DFA13DRM, DFA13IBC, DFA13 Manufacturer or supplier's details Petro-Canada Lubricants Inc. 2310 Lakeshore Road West Mississauga ON L5J 1K2 Canada Emergency telephone number Petro-Canada Lubricants Inc.: +1 905-403-5770; CHEMTREC Transport Emergency: 1-800-424-9300; Poison Control Centre: Consult local telephone directory for emergency number(s). Recommended use of the chemical and restrictions on use Recommended use : DURON ADVANCED 10W-30 is a superior quality heavy duty diesel engine oil specifically designed for enabling improved fuel economy in 2017 MY engines (and beyond) that specify API Service FA-4. Duron Advanced 10W-30 may be back serviceable in some applications, but only as recommended by the OEM. Prepared by : Product Safety: +1 905-491-0565 SECTION 2. HAZARDS IDENTIFICATION Emergency Overview Appearance Colour Odour viscous liquid GHS Classification Not a hazardous substance or mixture. GHS label elements Not a hazardous substance or mixture. Internet: lubricants.petro-canada.com/sds Page: 1 / 10

DURON ADVANCED 10W-30 Potential Health Effects Primary Routes of Entry Aggravated Medical Condition : Skin contact Eye contact Inhalation None known. : None known. Other hazards None known. IARC ACGIH No component of this product present at levels greater than or equal to 0.1% is identified as probable, possible or confirmed human carcinogen by IARC. No component of this product present at levels greater than or equal to 0.1% is identified as a carcinogen or potential carcinogen by ACGIH. SECTION 3. COMPOSITION/INFORMATION ON INGREDIENTS Hazardous components Chemical name CAS-No. Concentration lubricating oils (petroleum), C15-30, hydrotreated 72623-86-0 50-70 % neutral oil-based lubricating oils (petroleum), C20-50, hydrotreated 72623-87-1 20-30 % neutral oil-based lubricating oils (petroleum), C20-50, hydrotreated 72623-85-9 20-30 % neutral oil-based, high viscosity Zinc alkyldithiophosphate 1-3 % SECTION 4. FIRST AID MEASURES If inhaled In case of skin contact : Move to fresh air. Artificial respiration and/or oxygen may be necessary. Seek medical advice. : In case of contact, immediately flush skin with plenty of water for at least 15 minutes while removing contaminated clothing and shoes. Wash skin thoroughly with soap and water or use recognized skin cleanser. Wash clothing before reuse. Seek medical advice. In case of eye contact : Remove contact lenses. Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Internet: lubricants.petro-canada.com/sds Page: 2 / 10

DURON ADVANCED 10W-30 Obtain medical attention. If swallowed Most important symptoms and effects, both acute and delayed : Rinse mouth with water. DO NOT induce vomiting unless directed to do so by a physician or poison control center. Never give anything by mouth to an unconscious person. Seek medical advice. : First aider needs to protect himself. SECTION 5. FIREFIGHTING MEASURES Suitable extinguishing media Unsuitable extinguishing media Specific hazards during firefighting Hazardous combustion products Further information : Use extinguishing measures that are appropriate to local circumstances and the surrounding environment. : No information available. : Cool closed containers exposed to fire with water spray. : Carbon oxides (CO, CO2), nitrogen oxides (NOx), sulphur oxides (SOx), phosphorus oxides (POx), sulphur compounds (H2S), zinc oxides (ZnOx), metal oxides, hydrocarbons, smoke and irritating vapours as products of incomplete combustion. : Prevent fire extinguishing water from contaminating surface water or the ground water system. SECTION 6. ACCIDENTAL RELEASE MEASURES Personal precautions, protective equipment and emergency procedures Environmental precautions Methods and materials for containment and cleaning up : Use personal protective equipment. Ensure adequate ventilation. Evacuate personnel to safe areas. Material can create slippery conditions. : If the product contaminates rivers and lakes or drains inform respective authorities. : Prevent further leakage or spillage if safe to do so. Remove all sources of ignition. Soak up with inert absorbent material. Non-sparking tools should be used. Ensure adequate ventilation. Contact the proper local authorities. SECTION 7. HANDLING AND STORAGE Internet: lubricants.petro-canada.com/sds Page: 3 / 10

DURON ADVANCED 10W-30 Advice on safe handling : For personal protection see section 8. Smoking, eating and drinking should be prohibited in the application area. In case of insufficient ventilation, wear suitable respiratory equipment. Avoid contact with skin, eyes and clothing. Do not ingest. Keep away from heat and sources of ignition. Keep container closed when not in use. Conditions for safe storage : Store in original container. Containers which are opened must be carefully resealed and kept upright to prevent leakage. Keep in a dry, cool and well-ventilated place. Keep in properly labelled containers. To maintain product quality, do not store in heat or direct sunlight. SECTION 8. EXPOSURE CONTROLS/PERSONAL PROTECTION Components with workplace control parameters Components CAS-No. Value type (Form of exposure) lubricating oils (petroleum), C15-30, hydrotreated neutral oil-based lubricating oils (petroleum), C20-50, hydrotreated neutral oil-based lubricating oils (petroleum), C20-50, hydrotreated neutral oil-based, high viscosity Control parameters / Permissible concentration Basis 72623-86-0 TWA (Mist) 5 mg/m3 CA AB OEL STEL (Mist) 10 mg/m3 CA AB OEL TWAEV 5 mg/m3 CA QC OEL (Mist) STEV (Mist) 10 mg/m3 CA QC OEL TWA (Inhalable fraction) 5 mg/m3 ACGIH 72623-87-1 TWA (Mist) 5 mg/m3 CA AB OEL STEL (Mist) 10 mg/m3 CA AB OEL TWAEV 5 mg/m3 CA QC OEL (Mist) STEV (Mist) 10 mg/m3 CA QC OEL TWA (Inhalable fraction) 5 mg/m3 ACGIH 72623-85-9 TWA (Mist) 5 mg/m3 CA AB OEL STEL (Mist) 10 mg/m3 CA AB OEL TWAEV 5 mg/m3 CA QC OEL (Mist) STEV (Mist) 10 mg/m3 CA QC OEL TWA (Inhalable fraction) 5 mg/m3 ACGIH Internet: lubricants.petro-canada.com/sds Page: 4 / 10

DURON ADVANCED 10W-30 Engineering measures : No special ventilation requirements. Good general ventilation should be sufficient to control worker exposure to airborne contaminants. Personal protective equipment Respiratory protection : Use respiratory protection unless adequate local exhaust ventilation is provided or exposure assessment demonstrates that exposures are within recommended exposure guidelines. Respirator selection must be based on known or anticipated exposure levels, the hazards of the product and the safe working limits of the selected respirator. Filter type Hand protection Material : organic vapour filter : neoprene, nitrile, polyvinyl alcohol (PVA), Viton(R). Remarks Eye protection Skin and body protection Protective measures Hygiene measures : Chemical-resistant, impervious gloves complying with an approved standard should be worn at all times when handling chemical products if a risk assessment indicates this is necessary. : Wear face-shield and protective suit for abnormal processing problems. : Choose body protection in relation to its type, to the concentration and amount of dangerous substances, and to the specific work-place. : Wash contaminated clothing before re-use. : Remove and wash contaminated clothing and gloves, including the inside, before re-use. Wash face, hands and any exposed skin thoroughly after handling. SECTION 9. PHYSICAL AND CHEMICAL PROPERTIES Appearance Colour Odour Odour Threshold ph Pour point Boiling point/boiling range : viscous liquid : -42 C (-44 F) Internet: lubricants.petro-canada.com/sds Page: 5 / 10

DURON ADVANCED 10W-30 Flash point Fire Point Auto-Ignition Temperature Evaporation rate Flammability Upper explosion limit Lower explosion limit Vapour pressure Relative vapour density Relative density Density Solubility(ies) Water solubility Partition coefficient: n- octanol/water Viscosity Viscosity, kinematic : 227 C (441 F) Method: Cleveland open cup : 241 C (466 F) : Low fire hazard. This material must be heated before ignition will occur. : 0.8617 kg/l : insoluble : 66.2 cst (40 C / 104 F) 10.30 cst (100 C / 212 F) Explosive properties : Do not pressurise, cut, weld, braze, solder, drill, grind or expose containers to heat or sources of ignition. SECTION 10. STABILITY AND REACTIVITY Possibility of hazardous reactions Conditions to avoid Incompatible materials Hazardous decomposition products : Hazardous polymerisation does not occur. Stable under normal conditions. : Reactive with oxidizing agents and water. : May release COx, H2S, smoke and irritating vapours when heated to decomposition. Internet: lubricants.petro-canada.com/sds Page: 6 / 10

DURON ADVANCED 10W-30 SECTION 11. TOXICOLOGICAL INFORMATION Information on likely routes of exposure Skin contact Eye contact Inhalation None known. Acute toxicity Product: Acute oral toxicity : Remarks Acute inhalation toxicity : Assessment: The substance or mixture has no acute inhalation toxicity Remarks Acute dermal toxicity : Remarks Components: lubricating oils (petroleum), C15-30, hydrotreated neutral oil-based: Acute oral toxicity : LD50 (Rat): > 5,000 mg/kg, Acute inhalation toxicity Acute dermal toxicity : LC50 (Rat): > 5.2 mg/l Exposure time: 4 h Test atmosphere: dust/mist : LD50 (Rabbit): > 2,000 mg/kg, lubricating oils (petroleum), C20-50, hydrotreated neutral oil-based: Acute oral toxicity : LD50 (Rat): > 5,000 mg/kg, Acute inhalation toxicity Acute dermal toxicity : LC50 (Rat): > 5.2 mg/l Exposure time: 4 h Test atmosphere: dust/mist : LD50 (Rabbit): > 2,000 mg/kg, lubricating oils (petroleum), C20-50, hydrotreated neutral oil-based, high viscosity: Acute oral toxicity : LD50 (Rat): > 5,000 mg/kg, Acute inhalation toxicity Acute dermal toxicity : LC50 (Rat): > 5.2 mg/l Exposure time: 4 h Test atmosphere: dust/mist : LD50 (Rabbit): > 2,000 mg/kg, Internet: lubricants.petro-canada.com/sds Page: 7 / 10

DURON ADVANCED 10W-30 Skin corrosion/irritation Product: Remarks Serious eye damage/eye irritation Product: Remarks Respiratory or skin sensitisation Germ cell mutagenicity Carcinogenicity Reproductive toxicity STOT - single exposure STOT - repeated exposure SECTION 12. ECOLOGICAL INFORMATION Ecotoxicity Product: Toxicity to fish : Remarks Toxicity to daphnia and other aquatic invertebrates : Remarks Toxicity to algae : Remarks Toxicity to bacteria : Remarks Persistence and degradability Product: Internet: lubricants.petro-canada.com/sds Page: 8 / 10

DURON ADVANCED 10W-30 Biodegradability : Remarks Bioaccumulative potential Mobility in soil Other adverse effects SECTION 13. DISPOSAL CONSIDERATIONS Disposal methods Waste from residues : The product should not be allowed to enter drains, water courses or the soil. Offer surplus and non-recyclable solutions to a licensed disposal company. Waste must be classified and labelled prior to recycling or disposal. Send to a licensed waste management company. Dispose of product residue in accordance with the instructions of the person responsible for waste disposal. SECTION 14. TRANSPORT INFORMATION International Regulations IATA-DGR Not regulated as a dangerous good IMDG-Code Not regulated as a dangerous good Transport in bulk according to Annex II of MARPOL 73/78 and the IBC Code Not applicable for product as supplied. National Regulations TDG Not regulated as a dangerous good Not applicable for product as supplied. SECTION 15. REGULATORY INFORMATION This product has been classified according to the hazard criteria of the CPR and the MSDS contains all of the information required by the CPR. The components of this product are reported in the following inventories: Internet: lubricants.petro-canada.com/sds Page: 9 / 10

DURON ADVANCED 10W-30 DSL TSCA ELINCS On the inventory, or in compliance with the inventory All chemical substances in this product are either listed on the TSCA Inventory or are in compliance with a TSCA Inventory exemption. At least one component is not listed in EINECS but all such components are listed in ELINCS. SECTION 16. OTHER INFORMATION For Copy of SDS : Internet: lubricants.petro-canada.com/sds Western Canada, telephone: 1-800-661-1199; fax: 1-800-378-4518 Ontario & Central Canada, telephone: 1-800-268-5850; fax: 1-800-201-6285 Quebec & Eastern Canada, telephone: 1-800-576-1686; fax: 1-800-201-6285 For Product Safety Information: 1 905-491-0565 Prepared by : Product Safety: +1 905-491-0565 Revision Date : 2018/04/10 The information provided in this Safety Data Sheet is correct to the best of our knowledge, information and belief at the date of its publication. The information given is designed only as a guidance for safe handling, use, processing, storage, transportation, disposal and release and is not to be considered a warranty or quality specification. The information relates only to the specific material designated and may not be valid for such material used in combination with any other materials or in any process, unless specified in the text. Internet: lubricants.petro-canada.com/sds Page: 10 / 10