SEISMIC SHUTOFF CHARACTERISTICS OF INTELLIGENT GAS METERS FOR INDIVIDUAL CUSTOMERS IN JAPAN

Similar documents
Yasuyuki Hirose 1. Abstract

DAMAGE TO OIL STORAGE TANKS DUE TO TSUNAMI OF THE MW OFF THE PACIFIC COAST OF TOHOKU, JAPAN

STUDY ON TSUNAMI PROPAGATION INTO RIVERS

NT10-18 NATSUSHIMA / HYPER-DOLPHIN

DEVELOPMENT OF TSUNAMI REFUGE PETRI-NET SIMULATION SYSTEM UTILIZABLE IN INDEPENDENCE DISASTER PREVENTION ORGANIZATION

LABORATORY EXPERIMENTS ON WAVE OVERTOPPING OVER SMOOTH AND STEPPED GENTLE SLOPE SEAWALLS

WATER HYDRAULIC HIGH SPEED SOLENOID VALVE AND ITS APPLICATION

Study on fatal accidents in Toyota city aimed at zero traffic fatality

SIMULATION ON RESCUE IN CASE OF EARTHQUAKE DISASTER BY MULTI-AGENT SYSTEM

PROPAGATION OF LONG-PERIOD WAVES INTO AN ESTUARY THROUGH A NARROW INLET

Clarification of Behavior of Huge Tsunami Action on Bridges - Hydraulic Model Experiment and Simulation Technology -

EXAMINATION OF AE WAVE PROPAGATION ROUTES IN A SMALL MODEL TANK

LOCALLY CONCENTRATED SEVERE BEACH EROSION ON SEISHO COAST CAUSED BY TYPHOON T0709

A Study of the Normal Turbulence Model in IEC

Prologue. TSUNAMI - To Survive from Tsunami World Scientific Publishing Co. Pte. Ltd.

Application of pushover analysis in estimating seismic demands for large-span spatial structure

KY10-15 KAIYO / HYPER-DOLPHIN

A Study on Roll Damping of Bilge Keels for New Non-Ballast Ship with Rounder Cross Section

PROPOSAL OF NEW PROCEDURES FOR IMPROVED TSUNAMI FORECAST BY APPLYING COASTAL AND OFFSHORE TSUNAMI HEIGHT RATIO

Special edition paper

7 JAXA Special Publication JAXA-SP--8E the internal wall surface of the tower at the three different levels shown in Figure. Strain (in the vertical d

Evaluation of shared use of bicycles and pedestrians in Japan

THREE DIMENSIONAL STRUCTURES OF FLOW BEHIND A

EFFECTS OF IMPORT AND INVENTORY AMOUNTS ON CHANGES IN WHOLESALE PRICES OF SALMON IN JAPAN

Development of Fish type Robot based on the Analysis of Swimming Motion of Bluefin Tuna Comparison between Tuna-type Fin and Rectangular Fin -

EXPERIMENTAL STUDY ON THE HYDRODYNAMIC BEHAVIORS OF TWO CONCENTRIC CYLINDERS

PHYSICAL REQUIREMENTS FOR A TAKEOFF IN SURFING. Akihiko Kimura 1 and Taro Kakinuma 2

PRESSURE FLUCTUATIONS ACTING ON A TAPERED TALL BUILDING

Analysis of the Interrelationship Among Traffic Flow Conditions, Driving Behavior, and Degree of Driver s Satisfaction on Rural Motorways

Impact Points and Their Effect on Trajectory in Soccer

Effect of channel slope on flow characteristics of undular hydraulic jumps

SYSTEM IDENTIFICATION AND RESPONSE ANALYSIS OF RC HIGH-RISE BUILDINGS UNDER SUCCESSIVE EARTHQUAKES

ANALYSIS OF ACCIDENT SURVEY ON PEDESTRIANS ON NATIONAL HIGHWAY 16 USING STATISTICAL METHODS

M. Takezawa & Y. Maeno Department of Civil Engineering, College of Science & Technology Nihon University, 1-8 Kandasurugadai Chiyodaku, Tokyo, Japan

An analysis on feasibility of park & cycle ride system in a Japanese local city

Osaka University Graduate School of Engineering Division of Global Architecture Dept. of Naval Architecture and Ocean Engineering Takuya Okubayashi,

MODEL EXPERIMENT AND FIELD TEST OF PW-OWC TYPE WAVE POWER EXTRACTING BREAKWATER

Effect of Fluid Density and Temperature on Discharge Coefficient of Ogee Spillways Using Physical Models

FRAGILITY CURVES FOR GRAVITY-TYPE QUAY WALLS BASED ON EFFECTIVE STRESS ANALYSES

Traffic Accident Analysis System Using GIS. No.1

A New Generator for Tsunami Wave Generation

SCIENCE OF TSUNAMI HAZARDS

GROUND VIBRATION DURING GRAVEL PILE CONSTRUCTION

A numerical simulation of oil spill in Istanbul strait

Wave Setup at River and Inlet Entrances Due to an Extreme Event

SCIENTIFIC COMMITTEE TENTH REGULAR SESSION. Majuro, Republic of the Marshall Islands 6-14 August 2014

MODEL SHAKE TABLE TEST ON THE SEISMIC PERFORMANCE OF GRAVITY TYPE QUAY WALL WITH DIFFERENT FOUNDATION GROUND PROPERTIES

Modelling Pedestrian Route Choice Behaviour and Its Application to the Planning of Underground Shopping Streets

A Study on Weekend Travel Patterns by Individual Characteristics in the Seoul Metropolitan Area

SCREENING OF TOPOGRAPHIC FACTOR ON WIND SPEED ESTIMATION WITH NEURAL NETWORK ANALYSIS

The OWEZ Meteorological Mast

Comparison on Wind Load Prediction of Transmission Line between Chinese New Code and Other Standards

Bicycle Collision Analysis Using a Vehicle Driving Simulator MOVIC-T4

SIMULATION OF THE FLOW FIELD CHARACTERISTICS OF TRANSIENT FLOW

A computational study on structural barrier to vertical spread of window spill plume along building exterior façade under external wind

SEASONDE DETECTION OF TSUNAMI WAVES

Chapter 11 Waves. Waves transport energy without transporting matter. The intensity is the average power per unit area. It is measured in W/m 2.

A STUDY ON GAP-ACCEPTANCE OF UNSIGNALIZED INTERSECTION UNDER MIXED TRAFFIC CONDITIONS

Shoe-shaped Interface for Inducing a Walking Cycle

WATERWAYS AND HARBORS DIVISION Proceedings of the American Society of Civil Engineers. EQUILIBRIUM FLOW AREAS OF INLETS ON SANDY COASTS a

WAVE LOAD ACTING ON HORIZONTAL PLATE DUE TO BORE

Assessing the Traffic and Energy Impacts of Connected and Automated Vehicles (CAVs)

Noise Characteristics Of A Check Valve Installed In R22 And R410A Scroll Compressors

The OTSS System for Drift and Response Prediction of Damaged Ships

Open Research Online The Open University s repository of research publications and other research outputs

Utilization of the spare capacity of exclusive bus lanes based on a dynamic allocation strategy

Gender Differences in Competition: Evidence from Swimming Data Shoko Yamane 1 Ryohei Hayashi 2

DAMAGE TO STORAGE TANKS CAUSED BY THE 2011 TOHOKU EARTHQUAKE AND TSUNAMI AND PROPOSAL FOR STRUCTURAL ASSESSMENT METHOD FOR CYLINDRICAL STORAGE TANKS

A User Survey of Introducing Social Networking Sites into Enterprises. Received: April 10, 2013, Accepted: July 3, 2013

Inter-comparison of wave measurement by accelerometer and GPS wave buoy in shallow water off Cuddalore, east coast of India

Test Method of Trap Performance for Induced Siphonage

Stock Abundance and Size Compositions of the Neon Flying Squid in the Central North Pacific Ocean during

A STUDY ON LIQUEFIED GROUND DISRUPTION EFFECTS ON LIQUID STORAGE TANK BEHAVIOR

Hazard-Specific Annex Tsunami Annex Horry County, South Carolina

Performance of SSTH-70 after Delivery and Future of SSTH Masahiro Itabashi, Ryoji Michida Ishikawajima-Harima Heavy Industries Co.,Ltd.

1. On site calibration of a pressure gage using a mobile. 2. Temporal variation of Rn emanation at faults

Emergent walking stop using 3-D ZMP modification criteria map for humanoid robot

Wave Energy Atlas in Vietnam

Available online at ScienceDirect International Symposium of Transport Simulation (ISTS 16 Conference), July 7~8, 2016

Evaluation of bus lanes in central urban areas through the use of modelling techniques

Pedestrian Dead Reckoning Based on Human Activity Sensing Knowledge

Cover Sheet-Block 6 Wave Properties

Special edition paper

APPLICATION OF PUSHOVER ANALYSIS ON EARTHQUAKE RESPONSE PREDICATION OF COMPLEX LARGE-SPAN STEEL STRUCTURES

ABNORMALLY HIGH STORM WAVES OBSERVED ON THE EAST COAST OF KOREA

GEA FOR ADVANCED STRUCTURAL DYNAMIC ANALYSIS

SCIENTIFIC COMMITTEE SEVENTH REGULAR SESSION August 2011 Pohnpei, Federated States of Micronesia

A CASE STUDY CONSIDERING A 3-D PUSHOVER ANALYSIS PROCEDURE

Proposal for a System of Mutual Support Among Passengers Trapped Inside a Train

[Barve, 4(7): July, 2015] ISSN: (I2OR), Publication Impact Factor: 3.785

Planning Daily Work Trip under Congested Abuja Keffi Road Corridor

Toshihide Kashima Building Research Institute, Japan

Urban Environmental Climate Maps for Urban Planning Considering Urban Heat Island Mitigation in Hiroshima

MAR 110 LECTURE #14 Ocean Waves

ValidatingWindProfileEquationsduringTropicalStormDebbyin2012

ANALYSIS OF THE POSITIVE FORCES EXHIBITING ON THE MOORING LINE OF COMPOSITE-TYPE SEA CAGE

Modeling and simulation of multiple personal mobility. vehicles in pedestrian flows using personal space

Scales of Atmospheric Motion Scale Length Scale (m) Time Scale (sec) Systems/Importance Molecular (neglected)

EVALUATION OF TSUNAMI FLUID FORCE ACTING ON THE BRIDGE DECK

Analysis of Curling Team Strategy and Tactics using Curling Informatics

Transcription:

The Tenth East Asia-Pacific Conference on Structural Engineering and Construction August 3-5, 26, Bangkok, Thailand SEISMIC SHUTOFF CHARACTERISTICS OF INTELLIGENT GAS METERS FOR INDIVIDUAL CUSTOMERS IN JAPAN Fumio YAMAZAKI 1, Yoshihisa MARUYAMA 2, Akiko YAMAUCHI 3, Kenichi NABANA 3 and Hiroyuki NAKANE 3 ABSTRACT: After the 1995 Kobe earthquake, countermeasures against earthquakes got higher priority than before. As one of such earthquake countermeasures, Tokyo Gas Co., Ltd. introduced an earthquake monitoring and rapid damage assessment system called SUPREME. This system has been under operation since 21. The intelligent gas meters have been deployed for 9.8 million customers in the area where Tokyo Gas Co., Ltd. provides the service. The gas meter stops gas supply if earthquake motion exceeds a certain level. SUPREME has a subsystem to estimate the number of gas meters which stop gas supply because of an earthquake. However, the accuracy of estimation by this subsystem is not good because the characteristics of gas supply shutoff by intelligent gas meter are not very clear. In this study, to improve the accuracy of estimation, the characteristics of gas supply shutoff by intelligent gas meter are investigated based on shaking table tests and the questionnaire survey among employees of Tokyo Gas Co., Ltd. KEYWORDS: intelligent gas meter, seismic shutoff, shaking table test, SUPREME 1 INTRODUCTION The 1995 Kobe earthquake caused serious damages to various infrastructures and buildings in the highly populated area of central-western Japan. The gas system in this area was also seriously affected [1]. After this earthquake, countermeasures against earthquakes got higher priority than before. As one of such countermeasures, Tokyo Gas Co., Ltd. introduced an earthquake monitoring and rapid damage assessment system, SIGNAL (Seismic Information Gathering and Network Alert), with 331 SI-sensors in 1994. Expanding SIGNAL into a much denser seismic monitoring network with about 38 SIsensors, SUPREME (Super-Dense Real-time Monitoring of Earthquakes) has been under operation since 21 [2]. The SI sensors measure the peak ground acceleration (PGA) and spectrum intensity (SI) at district regulator stations. The data from the network will be used for an early damage assessment of the city gas network of Tokyo Gas Co., Ltd. and the results will serve as important information for the decision making of the gas supply suspension. The intelligent gas meters have been deployed for 9.8 million customers. The gas meter stops gas supply if earthquake motion exceeds a certain level (Fig. 1). It is designed to shut off gas supply if the peak acceleration is in the range of 2-25 cm/s 2. SUPREME has a subsystem to estimate the number of gas meters that shut off gas supply because of an earthquake. However, the accuracy of estimation by this subsystem is not good because the characteristics of gas supply shutoff by the intelligent gas 1 Professor, Department of Urban Environment Systems, Chiba University, Japan. 2 Research Associate, Department of Urban Environment Systems, Chiba University, Japan. 3 Center for Disaster Management and Supply Control, Tokyo Gas Co., Ltd., Japan

Head Office Automatic Shut-Off DISTRICT REGULATOR VENT STUCK GS Vent VENT STUCK Supply Suspension WORKS INTELLGENT GAS METER LP MP Shut-Off HP Figure 1. Outline of emergency control of natural gas supply system in Japan ShutoffAcceleration (cm /s/s) 2 15 1 5 Period:.3 s Old Model(LateralDirection) Old Model(Cross Direction) New Model(LateralDirection) New Model(Cross Direction) NB-1NB-3NB-5NB-1NI-1 NI-3 NI-5 NS-1 Type ofgas Meter 1 2 3 4 5 6 7 8 9 ShutoffAcceleration (cm /s/s) 2 15 1 5 Period:.7 s Old Model(LateralDirection) Old Model(Cross Direction) New Model(LateralDirection) New Model(C ross Direction) NB-1 NB-3 NB-5NB-1 NI-1 NI-3 NI-5NS-1 Type ofgas Meter 1 2 3 4 5 6 7 8 9 Figure 2. Shutoff acceleration of various types of intelligent gas meters conducted by producteers (Old model: until February 23, New model: from February 23) meter are not very clear. Therefore, the subsystem sometimes overestimates the number of gas meters that shut off gas supply, and sometimes underestimates it. In this study, to improve the accuracy of estimation, the characteristics of gas supply shutoff by the intelligent gas meter are investigated based on shaking table tests and questionnaire survey among employees of Tokyo Gas Co., Ltd. 2 INVESTIGATION OF SEISMIC SHUTOFF CHARACTERISTICS OF INTELLIGENT GAS METER BASED ON SHAKING TABLE TESTS 2.1 SHUTOFF CHARACTERISTICS UNDER SINUSOIDAL WAVE Intelligent gas meters are designed to shut off gas supply if the acceleration in the range of 2-25 cm/s 2 is detected. The producteers of gas meter are conducting product tests. In the tests, gas meters are subjected to sinusoidal waves with the period of.3 s and.7 s. Figure 2 shows the average shutoff accelerations among various types of intelligent gas meters. This figure suggests that the shutoff acceleration does not depend on the type of gas meters. The shutoff acceleration under sinusoidal wave with the period of.3 s is almost equal to that under sinusoidal wave with the period of.7 s. However, in the product testing, only two periods are adopted as the period of the applied sinusoidal waves. Therefore, for a further investigation of seismic shutoff characteristics of intelligent gas meter, it is necessary to consider the shutoff acceleration of gas meters subjected to sinusoidal waves with various periods.

1 2 3 Z X Y ShutoffA cceleration (cm /s 2 ) 3 2 1 Figure 3. Shaking table test of intelligent gas meters X Direction N B 3-1 N B 3-2 N B 3-3 Average (NB3).2.4.6.8 1 2 NB4-1 NB4-2 NB4-3 Average (NB4) Figure 4. Shutoff accelerations with respect to the periods of sinusoidal waves applied to the X direction In this study, a series of shaking table tests of intelligent gas meters was conducted. The shaking table possessed by Pipeline Technology Center, Tokyo Gas Co., Ltd. was employed in the experiment. The sinusoidal waves with the period of.2-1.8 s were applied to the gas meters fixed on the wall (Fig. 3). The amplitudes of sinusoidal waves increase with the interval of 5 cm/s 2. The change of power voltage associated with the shutoff by gas meter was detected, so that the time when the gas meter shut off gas supply could be identified exactly. Two types of gas meters, which are NB-3 and NB-4, were used in the experiment. Three gas meters of each type were subjected to excitation. Figure 4 shows the relationship between the period of applied sinusoidal waves and shutoff accelerations of intelligent gas meters. According to the figure, the shutoff accelerations with the periods of.2 s and 1.8 s are a little smaller. However, the shutoff accelerations with the periods of.3-1.5 s are almost constant, and the shutoff acceleration is about 19 cm/s 2. The difference between the shutoff acceleration of NB-3 type gas meter and that of NB-4 type was not observed in the period range, but the shutoff acceleration of NB-3 type is smaller than that of NB-4 type when the period of sinusoidal wave is equal to 1.8 s. 2.2 SHAKING TABLE TESTS USING ACTUAL SEISMIC MOTIONS To evaluate the characteristics of seismic shutoff of intelligent gas meters revealed in the previous section, four sets of actual seismic motion records were used as input motions in the shaking table tests: 1) the Kobe Marine Observatory record of Japan Meteorological Agency (JMA) in the 1995 Kobe earthquake, 2) the K-NET Tomakomai record in the 23 Tokachi-Oki earthquake, 3) the K-

Table 1. The number of intelligent gas meters which shut off gas supply during the shaking table test JMA Kobe Miyako-cho, Tokyo Gas K-NET Yokaichiba PGA (cm/s 2 ) NB-3 NB-4 NB-3 NB-4 NB-3 NB-4 13 - - - - 15 3 - - - 17 3 19-3 3 2 1 21 - - - 3 3 1 23 - - - - - 1 25 - - - - - 3 ShutoffA cceleration (cm /s 2 ) 3 2 1 Two directionalshaking Average (NB3) Average (NB4) NB3 Cut-Off NB4 Cut-Off Yokaichiba JM A Kobe Miyako-cho.2.4.6.8 1 2 (a) Shutoff acceleration ShutoffVelocity (cm /s) 6 4 2 Average (NB3) Average (NB4) NB3 Cut-Off NB4 Cut-Off Two directionalshaking Yokaichiba JM A Kobe Miyako-cho.2.4.6.8 1 2 (b) Shutoff velocity Figure 5. Comparisons of the shutoff accelerations and the shutoff velocities between under seismic motions and sinusoidal waves NET Yokaichiba record in the North-eastern Chiba Prefecture earthquake (April 11, 25), and 4) the Miyako-cho Tokyo Gas seismic observation station record in the North-western Chiba Prefecture earthquake (July 23, 25). The Tomakomai record was selected as the typical long-period record. On the contrary, the K-NET Yokaichiba record was employed as the short-period seismic motion. The applied peak ground acceleration (PGA) of the record, which is obtained as the resultant of two horizontal components, was scaled to be 13-25 cm/s 2. Table 1 shows the number of gas meters which shut off gas supply because of ground shaking. It should be noted that the K-NET Tomakomai record whose PGA is equal to 13 cm/s 2 could not be applied to the shaking table because of the limitation of actuators. Therefore, the result under the K- NET Tomakomai record is not listed in Table 1. The gas meters did not shut off gas supply under the

ShutoffVelocity (cm /s) 6 5 4 3 2 1 Non Shutoff(a ldata) n = 1271.2.4.6.8 1 2 (a) Non-shutoff ShutoffVelocity (cm /s) 6 5 4 3 2 1 Rate ofshutoff(alldata) n = 144 1..8.6.4.2.2.4.6.8 1 2 ShutoffVelocity (cm /s) 6 5 4 3 2 1 Rate ofshutoff(1st Floor) n = 71 1..8.6.4.2.2.4.6.8 1 2 (b) Rate of shutoff (all data) (c) Rate of shutoff (1st floor) Figure 6. Relationship between the period of seismic motion and the PGV allocated to the responders of the questionnaire survey non-scaled K-NET Tomakomai record (PGA = 87.2 cm/s 2 ). According to the result, the NB-3 gas meters shut off gas supply under smaller seismic motion than NB-4 gas meters especially under the JMA Kobe record. Figure 5 compares the results of shaking table tests under sinusoidal waves and those under actual ground motion records. The period of seismic motion was determined by Eq. (1). T = 2πPGV * PGA* (1) where T is the period of seismic motion. PGA* and PGV* are the peak ground acceleration and the peak ground velocity by the resultant of two horizontal components, respectively. Figure 5 illustrates the shutoff accelerations and shutoff velocities when all the three gas meters shut off gas supply under seismic motion. According to the figure, the shutoff acceleration under the K-NET Yokaichiba record is larger than that obtained under sinusoidal waves. As is mentioned before, the K-NET Yokaichiba record was selected as an example of short-period record. The peak ground acceleration is dependent on the short-period components of ground excitation. This indicates that the intelligent gas meters may not be sensitive to the short-period ground motions. With respect to the shutoff velocities of gas meters (Fig. 5(b)), the results obtained from the seismic motions coincide with those obtained from sinusoidal waves. The PGV does not depend on the short-period components of ground motion, so the results under the K-NET Yokaichiba record show good agreement with those under sinusoidal waves. 3 QUESTIONNAIRE SURVEY ON SEISMIC SHUTOFF OF INTELLIGENT GAS METERS On July 23, 25, the North-western Chiba Prefecture earthquake occurred (M JMA = 6.). The Tokyo Metropolitan area suffered from this earthquake, and the lifelines, especially, train services and road

traffic networks ceased their functions. The intelligent gas meters perceived the seismic motion, and some of them shut off gas supply. In order to reveal the effects of seismic motion to the shutoff behavior of intelligent gas meters, the questionnaire survey was conducted for employees of Tokyo Gas Co., Ltd. In the questionnaire, the responders were asked to answer the address of residence, what floor they live on, and whether the gas meter stopped due to the earthquake or not. From the addresses of responders, the seismic intensity was allocated using the nearest record of SIsensors deployed by Tokyo Gas Co., Ltd. In SUPREME, the spectrum intensity (SI) and the PGA recorded by SI-sensors can be monitored and gathered at an early stage of the earthquake. Therefore, these two seismic indices were adopted in the analysis. The SI was converted to the PGV using the relationship by Tong et al. [3] shown in Eq. (2). SI = 1. 18PGV (2) The period of seismic motion was determined by Eq. (1). Figure 6(a) shows the relationship between the period of seismic motion and the PGV for the gas meters that did not shut off gas supply. Figure 6 (b) and (c) show the relationships between the period and the shutoff velocities of the gas meters. The size of the symbol means the rate of shutoff by gas meters in Fig. 6(b) and (c). The rate of shutoff was calculated based on the all data (located within 5 m from the nearest seismic observation station) of the questionnaire survey in Fig. 6(b). Figure 6(c) shows the rate of shutoff calculated from the results of the responders who live on the 1st floor of an apartment building or in two or one storied house. In Fig. 5, the results of the shaking table test using the sinusoidal waves are also illustrated. According to the figure, the symbols that show the non-shutoff gas meters are mainly concentrated in the lower part of the line drawn from the results of the experiments. The symbols in Fig. 6(b) spread out comparing with those in Fig. 6(c). This is because the seismic responses of the buildings affect the behavior of shutoff characteristics of intelligent gas meters. This suggests that the effects of the structural response to seismic motion should be considered to predict the number of shutoff gas meters. 4 CONCLUSIONS In this study, to investigate the characteristics of seismic shutoff of intelligent gas meters, a series of shaking table tests were conducted. According to the results, the characteristics of seismic shutoff of gas meters estimated by applying sinusoidal waves coincided with the results of experiments under actual seismic records. The questionnaire survey to reveal the characteristics of seismic shutoff during the 25 North-western Chiba Prefecture earthquake was also conducted among the employees of Tokyo Gas Co., Ltd. The results of the questionnaire survey were compared with those of the shaking table tests. To predict the number of intelligent gas meters that shut off gas supply, the seismic response of structures should be considered in a proper manner. 5 REFERENCES 1. Oka, S., Damages of gas facilities by great Hanshin earthquake and restoration process. Proc. of the 6th U.S.-Japan Workshop on Earthquake Disaster Prevention for Lifeline Systems; 1995, pp. 253-269. 2. Shimizu, Y., Yamazaki, F., Yasuda, S., Towhata, I., Suzuki, T., Isoyama, R., Ishida, E., Suetomi, I., Koganemaru, K., and Nakayama, W., Development of real-time control system for urban gas supply network. Journal of Geotechnical and Geoenvironmental Engineering; ASCE, 26, Vol. 132, No. 2, pp. 237-249. 3. Tong, H., Yamazaki, F., Sasaki, H. and Matsumoto, S., A relationship between seismic ground motion severity and house damage ratio, Proceedings of the Ninth Japan Earthquake Engineering Symposium; 1994, 2299-234 (in Japanese).